for M-Bus, Modbus and 1-Wire devices

Similar documents
IntesisBox BACnet IP Server - M-Bus

Description (common to all MPC controllers)* Connection and communication functions 2 / 5

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.

SB2WEB24. SB2WEB BACnet Controller. Benefits. Description

MatrixBBC. Protocol Implementation Conformance Statement (PICS) Product Description: BACnet Standardized Device Profile:

MODULAR CIRCUIT MONITORING SYSTEM

VMU-C/Y, Em 2 CARLO GAVAZZI. The evolution in Energy Management. Monitoring system for Energy Management. A u t o m a t i o n C o m p o n e n t s

Version 1.0c May 6, 2010 ATK3

NS Series CO 2 Network Zone Sensors Protocol Implementation Conformance Statement

Gateway for integration of Modbus RTU slave devices into BACnet IP based systems.

Delta Control Unit (DCU) 3.30 BACNET PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT

PG AC Modbus TCP to LonWorks Protocol Converter

Vision570 TM /560 TM. Color OPLC TM. Color Vision570 TM /560 TM Series Featuring:

BACnet Protocol Implementation Conformance Statement Automated Logic G5RE

Delta ORCAview Date: August 5, 2009 Vendor Name: Delta Controls Inc. Product Name:

LGATE-950: Universal Gateway

BACnet Protocol Implementation Conformance Statement

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

CAS & CAS UL. Modbus RTU Data Client. (Hardware and Software Solutions) Manual

Com X 210, Com X 510 Technical Datasheet

PG AB Notifier NFS 3030 to Modbus RTU Protocol Converter

WT-BAC-IP Gateway Protocol Implementation Conformance Statement

Efficient. Innovative. Sustainable.

BACnet Protocol Implementation Conformance Statement Unitary Protocol Converter (UPC)

SH2WEB24. Central unit module. Benefits. Description

IntesisBox Modbus Server - BACnet/IP Client

S4 Open: BACnet N2 Router

Procon BAC-A/50. Installation Instructions MITSUBISHI ELECTRIC

Communication Interface

ESAC ebacgw SNMP. Date: Mar 08,2009. Product Model Number: Product Version: 1.0 BACnet Protocol Revision: 3. Product Description:

BrightCore BACnet Lookout V2.2 Product Family

BAS Web Server Datasheet

PG AB Omron FINS to Modbus RTU Protocol Converter

1210 TM /1040 TM. Features: V1210 Flat Panel. V1040 Classic Panel HMI PLC. Communication

BACnet MS/TP-module. Data sheet. for MULTICAL 403 and 603

BUILDING MANAGEMENT. OpenBAS-HV-NX10 SERIES CATALOG NUMBER. Description. Features

Delta Controller Engine (DCE) Firmware

0.1 Slow Monitoring and Recording System

ETC Reference Guide BACnet PICS for P-CCS

IntesisBox KNX - BACnet/IP Client

IntesisBox KNX - BACnet/IP Client

Mapping Modbus Registers to BACnet Objects

The Simply Smart Way to Optimize Building Control and Performance

SA2WEB24. Central unit module. Benefits. Description

entelibus CPU Engine (eb-eng) Firmware

For more information Contact with details of the application.

PG AB Fike Cheetah to Modbus TCP Protocol Converter

S u p p l e m e n t TQS3 MODBUS. Description of product modification with MODBUS RTU. 31. March 2008 w w w. p a p o u c h.

BACnet Protocol Implementation Conformance Statement OEMPrtl Pro

BACnet Protocol Implementation Conformance Statement Automated Logic Corporation LGR25, LGR250, LGR1000

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

Advanced Real-Time Energy Metering

IntesisBox BACnet/IP Server DALI

Zoning System TEC2647Z-2 and TEC2647Z-2+PIR Zone Controllers Protocol Implementation Conformance Statement

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

Compact data logger offering best-in-class noise resistance and communication function

PXC Compact Series on BACnet/IP

Installation Manual. DZK BACnet

PG AA BACnet IP to Modbus RTU Protocol Converter

GS828. GPRS Data Logger

WattmonMEGA Remote Monitoring & Control Platform

Trend Log/BACnet Trend Log

Send documentation comments to For more information on the configtool interface, see Chapter 4, Mediator configtool.

PG AA Modbus RTU to SNMP Protocol Converter

NB-GPC Family Protocol Implementation Conformance Statement (PICS)

All it takes to measure, collect and analyze energy consumption in heating and cooling applications

Web-enabled DAQ System

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

How to monitor M-Bus and wireless M-Bus systems

BACnet Protocol Implementation Conformance Statement (PICS) MULTICAL 62/601/602/6L2/6M2/801

TB7300 Series Fan Coil Unit Communicating Thermostats BACnet Protocol Implementation Conformance Statement (PICS)

NB-ASC Family Protocol Implementation Conformance Statement (PICS)

IntesisBox Modbus Server M-Bus

LDALI ME204-U, LDALI ME201 U

Energy consumption optimization for a wireless sensor for the IOT

CAS IKS Gateway (Modbus RTU/TCP and HTML) Manual

User guide. SonoMeter 30. Ultrasonic energy meter for heating and cooling applications. Danfoss VUIGI102 1

ASCII Server - BACnet/IP Client. Gateway for integration of BACnet IP devices into ASCII enabled control systems.

NS Series Temperature and Humidity Network Zone and Discharge Air Sensors Protocol Implementation Conformance Statement

DIRIS Digiware D and C Communication and control power interfaces

IntesisBox BACnet/IP Server M-Bus meters

PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT (NORMATIVE) (This annex is part of this Standard and is required for its use.)

BACnet Protocol Implementation Conformance Statement

SHEET. BASgatewayLX Modbus to BACnet Gateway. BASgatewayLX

MULTICAL 403 MULTICAL 603

N2 Analog Input/ BACnet Analog Input

Communication Interface

Visi.Plus Protocol Implementation Conformance Statement (PICS)

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

Key Features and Benefits

IntesisBox Modbus Server BACnet MSTP and BACnet/IP client

Electronics Single wire communication

Specification for Smart Panels : Energy management system to monitor, control and maintain building installations

Webdom Datalogger 1.5

QC BAC-BOX PIC STATEMENT

GS828-H. GPRS Data Logger

Honeywell ComfortPoint TM Open Plant Controller Protocol Implementation Conformance Statement (PICS)

Revise Quick Start Guide

Transcription:

Kara Systems Kara BACnet Gateway V2.2 for M-Bus, Modbus and 1-Wire devices The Kara BACnet Gateway integrates M-Bus(EN-1434-3) Modbus and 1-Wire devices to a BACnet Infrastructure Network. It is a three in one gateway and you can connect all three different buses at same time. The Gateway has a small robust case and can be directly plunged into the power plug. It has no movable parts, needs no maintenance and consume less than 5 Watts. The intuitive configuration is done over the integrated web server. M-Bus The M-Bus gateway detects all kinds of meters such as electric, gas, heat, water and others. It supports M-Bus meters types, Mode1, Mode 2, Fixed Data Response and Variable Data Response types. Every single M-Bus meter record can be explicit configured to be converted to a BACnet Analog Object. It converts the meters readings, media and units to BACnet Analog Inputs properties respectively. Meter hourly readings are stored for 7 days in memory and daily readings are stored on flash memory. Meter readings and consumption can be display on an web interface or exported to Excel. BACnet clients connected to the BACnet/IP or BACnet/Ethernet network can read the M-Bus readings by polling or by making a subscription request (COV). Modbus Modbus devices are converted to BACnet Binary and Analog Objects respectively. The Gateway support Modbus over EIA-232, EIA-485(optionally) and over TCP/IP. The gateway polls the modbus objects at a configurable rate. Values can be read or written by BACnet clients and by the Web Interface using the browser. BACnet clients can requests COV. 1-Wire 1-Wire is a device communications bus system designed by Dallas Semiconductor Corp. that provides low-speed data, signaling, and power over a single signal. 1-Wire is similar in concept to I²C, but with lower data rates and longer range. It is used to communicate with small inexpensive devices such as

digital thermometers, humidity Sensors, Channel I/O etc. You can connect the 1-Wire bus either using direct the USB Interface DS2490 or the serial DS2480B Interface. BACnet The Kara BACnet Gateway simulates a BACnet server device over BACnet/IP or BACnet/Ethernet. It Supports Analog, Binary and Notification Objects. BACnet Broadcast Management Device support included. Proprietary BACnet properties are defined to include M-Bus and Modbus special properties. See BACnet Characteristics.

Gateway Scenario: Hardware Characteristic Support for RS-232, optional RS-485 BACnet/IP and BACnet/Ethernet 10/100Mbps Ethernet port Extremely compact design, 68 x 108x 48mm Ultra low consumption, less than 5 Watts with integrated power supply No moving parts WLAN optionally, by simple plugging an USB Wi-Fi dongle. Regulations: CE Class A, FCC Class A, UL Operation Temperature: 0 to 70C(32 to 158F)

M-Bus Characteristic: Support for all kind of Meters types, Mode 1, Mode 2 and fixed and variable data types. 253 meters on RS232 interface Primary addressing up to 250 Meters Secondary addressing meter scanning Baudrates 300, 600, 1200, 2400, 9600, 19200, 38400 List of all meters records Every M-Bus meter record can be converted to a BACnet Analog Input Multiplier Variable for MBus Value. You can set a multiplier float value for each Mbus record. For exaplme you can convert cubic meter/hour Gas to KWH just set the multiplier to 10.7 Unit conversion. The device converts automatically the Mbus unit to BACnet unit, but you cal also set the BACnet unit for every Mbus record. Web Interface Configuration for M-Bus, meter name, reading Interval. Daily meter readings are saved in flash memory Hourly, daily, montly and yearly Meter Consumption reports The consumption data is written on an external SD-Card Export meter readings and consumption information to Excel XML format or trend charts.

Modbus Characteristic: Support Modbus EIA-232, EIA-485 and TCP/IP Interfaces Baudrates 300, 600, 1200, 2400, 9600, 19200, 38400 Web Interface for list all Object readings Write to Objects via BACnet or Web Interfaces. Configurable Interval readings and multiplier. Modbus Objects Coils, discrete Inputs, Holding Registers, Input Registers 1-Wire Characteristic Bus Interface with either USB Interface DS2490 or USB-Serial DS2480B connect as much devices as the 1-Wire Physical Bus permits. Supported devices: DS18B20, DS 18S20 Temperature sensor DS2438 Smart Battery Monitor, Humidity sensor DS2423 Counters DS2408 8 Channel Bidirectional Port DS2450 Quad ADC Other devices on request

BACnet Characteristics BACnet Connection BACnet/IP and BACnet/Ethernet BACnet Broadcast Management Device support included Broadcast I am command button converts M-Bus Units to BACnet Units BACnet Services supported: Read Property Service, Read Property Multiple Service, Write Property Service (support for priorities), TimeSynchronization Service, UTCTimeSynchronization Service, Subscribe- COV Service, ConfirmedEventNotification Service, Subscribe-COV-Property Service, Who-Is and I-Am Services, Who-Has and I-Have Services, Create Object (for Notification Class Object), Delete Object, Get EventInformation, Get Alarm Summary Additional BACnet Properties Property ID Property Type Name 1002 unsigned Meter Primary address 1003 unsigned Meter Identification 1004 Unsigned Meter Baud rate 1005 Enumerated Meter Manufacture 1006 Unsigened Meter Version 1007 Enumerated Medium 1008 Bit_String M-Bus meter Status 1010 Enumerated Meter Error 1011 Unsigned Meter's record number 1101 Enumerated Modbus connection type 1102 Unsigned Modbus Slave Address 1103 Octed String Modbus TCP/IP Address 1104 Unsigned Object Address info@karasystems.eu http://www.karasystems.eu