DALI Gateway 5502DAL. Installation Instructions

Similar documents
C-Bus Network Bridge 5500NB. Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

DALI Gateway 5502DAL. Programming Guide

C-Bus Ceiling Sweep Fan Controller L5501RFCP. Installation Instructions

2 Channel DALI Power Supply and Interface Installation Instructions. This page was intentionally left blank

C-Bus 4 Channel Voltage Free Changeover Relay L5504RVFC. Series. Installation Instructions

C-Bus Four Channel Voltage Free Relay Installation Instructions

C-Bus Pascal Automation Controller

C-Bus Eight and Twelve Channel Voltage Free Relay Installation Instructions

Line Controller 16-input, 8-output 2 DALI line, 1 DALI line DCBM DCBM Installation Instructions

C-Bus Two Channel Infrared Transmitter Unit Installation Instructions

CLIPSAL CLIPSAL POWER MUTE < SOURCE > < VOLUME > Multi Room Audio Amplifier D/ R/ R User s Guide

USB ZB Interface Unit Ethernet ZB Interface Unit 5200UZI WHC2_ EZI WHC2_5922. User s Manual

Translink Controller Installation Manual V1.0

Ethernet/DALI Interface 2 DALI Lines

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

C-Touch Spectrum Colour Touchscreen

C-Touch Colour Touch Screen. 50x0CTC3 Series. Installation Instructions

* * ARM MONITOR EXCLUDE MEMORY. HomeSafe Security Panel 5400/16CB. Programming Manual C-Bus Supplement

Architectural Dimmer. L51xxDxxUA Series. Installation Instructions

MLHG6. Iso-Gard Line Isolation & Overload Monitor (LIOM) Setup Guide ! WARNING. Components

Square D Clipsal Pascal Automation Controller

One Channel and Two Channel DALI Relay Device

Installation Instructions

LEDsmart+ Slave Relay Device

StarServe Harmonicas. Wiring Instructions. Shallow. Deep. Angled. Telephone Modules 8052/4RJ 8052/4RJDMB 8052/4RJSMB Angled 3105ATPP2X4

RAPIX Lighting Control System - ehub

C-Touch Colour Touch Screen. Installation Instructions 50xxCTC2 Series

MLHG6-AU. Iso-Gard Line Isolation Monitor (LIM) Setup Guide DANGER. Components

C-Bus Network Analyser Operating Instructions 5100NA

Local Stereo Input Module 3105LSIM. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

SoundwebTM. Installation Guide

Extension module for lighting control

2C138. Sensitive Earth Fault Relay. Features. Application. Operation

Piccola Smart Box Member of Modul MAS family

DEEP SEA ELECTRONICS PLC

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

USB 2.0 Ranger Port USB m CAT 5e/6/7 Extender System. User Guide

DSE2548 LED expansion module INTRODUCTION

Digital input modules

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

TM3DI16G module TM3-16 inputs spring

Multifunctional time delay relay MFT U31S, MFT U41SE

2T105. Multi Range Digital Setting Time Delay Relay. Features. Application. Operation

RE9RA21MW7 off-delay timing relay s V AC -

Operating instructions. Switching amplifier DN0210 DN / / 2015

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

C-Bus Interface Devices for wider control of a home or building.

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input

FLEX Ex Spring Clamp Terminal Base

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

TM3TI4 module TM3-4 inputs temperature

USB 2.0 CAT5E/6/7 EXTENDER

Operating instructions. Speed monitor D / / 2014

OPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

SP x4 DVI over Single CAT5 Distribution Amplifier. User Manual. Made in Taiwan

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

Installation Instructions

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

TF501, TF521 Terminal Bases

CompactBlock Guard I/O EtherNet/IP Safety Modules

TM241CE24T controller M IO transistor PNP Ethernet

Installation instructions Inclination sensor EC2019 EC / / 2013

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

RMCN22BD Analog Converter ma - for Zelio Analog

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

Tina 1A Blanking plug

RM4TR31 three-phase network control relay RM4-T - range V

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

Redundancy unit CP-A RU

TM241CE40R controller M IO relay Ethernet

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A)

CertaDrive. LED indoor drivers. May, Design-in guide - Philips CertaDrive Indoor LED drivers

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

Changes or modifications not expressly approved by InFocus Corporation may void authority to operate the equipment.

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

PRODUCT SPECIFICATION. PC Board Relays. Series.

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

SR2B121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - display

Rugged MediaConverter

Transcription:

DALI Gateway 5502DAL Installation Instructions

Contents 1.0 Product Range...3 2.0 Description...3 3.0 Features...3 4.0 C-Bus Indicators...4 4.1 Unit/Comms Indicator...4 4.2 C-Bus Indicator...4 5.0 Wiring Instructions...5 6.0 Connection to the C-Bus Network...6 7.0 Network Burden...7 8.0 C-Bus Side Programming Requirements...7 9.0 Power Surges and Short Circuit Conditions...7 10.0 Megger Testing...7 11.0 Important Warning...7 12.0 Standards Complied...8 13.0 Product Specifications...9 14.0 Mechanical Specifications...10 15.0 Two Year Warranty...11 16.0 Technical Support and Troubleshooting...12

1.0 Product Range 5502DAL 2.0 Description C-Bus DALI Gateway The 5502DAL C-Bus DALI Gateway unit is a C-Bus system support device, designed to provide an isolated communications path between a C-Bus network and two DALI networks. For ease of installation the unit is DIN rail mounted, measuring 4m wide (1m = 17.5 +0.5/-0.0mm). 3.0 Features The DALI Gateway provides two C-Bus connections through the use of RJ45 connectors, allowing similar units to be quickly looped together. In normal operation, the unit draws 32mA from the C-Bus network. The DALI Gateway is capable of generating C-Bus clock signals. Each DALI network can have up to 64 addressable DALI devices, such as fluorescent ballasts and low voltage transformers. The DALI Gateway does not have its own DALI addresses. It is transparent and is not visible to other DALI devices. The DALI Gateway provides two-way communication. Selected C-Bus messages are routed to an appropriate DALI network, and DALI lighting messages are routed to the C-Bus network. The DALI Gateway constantly monitors both DALI networks. It is capable of detecting and reporting C-Bus faulty lamps in fluorescent ballasts or failed DALI units. DALI networks are insulated from C-Bus and from each other by optocouplers. The insulation is capable of withstanding mains voltage. 3 of 12

4.0 C-Bus Indicators 4.1 Unit/Comms Indicator If the unit is powered and functional, the unit/comms indicator will be illuminated and steady. During data transfer on the RS232 port the unit/comms indicator will flash. C-Bus Group Address ON Flashing DALI Address Power on and functional Data exchange in progress 4.2 C-Bus Indicator This indicator shows the status of the C-Bus network at this unit. If sufficient network voltage and a valid C-Bus clock signal are present then the OK signal will be displayed (steady on). If a network is connected, which has more current load than the power supplies can support, this indicator will flash to show a marginal network voltage. If there is no C-Bus network clock present this indicator will not light. C-Bus Group Address ON Flashing OFF DALI Address C-Bus network operational Insufficient power to support network No C-Bus clock present or insufficient power to support network or C-Bus not connected (check terminations) 4 of 12

5.0 Wiring Instructions WARNING: DO NOT tie the outputs of the DALI power supplies together. Damage to the supplies and Gateway unit will occur. C-Bus RJ45 Connections NOTE: There is a mutual twist of solid and dotted conductors of opposing coloured conductors. This ensures a good electrical termination with favourable common mode noise characteristics. 64 DALI devices (max.) can be connected on a single DALI output channel. 50 DALI Gateway devices (max.) can be connected on a single C-Bus network. A maximum torque of 1.4Nm should be applied to the mains rated screw terminals. Each DALI network must be interconnected with a maximum total wiring of 300m. The wire used should be mains rated with double insulation and a minimum 1.5mm 2 cross section. Three rubber bungs are supplied (3 of) for unused RJ45 connectors, to stop foreign bodies from entering the unit. Always ensure these bungs are installed when the unit is to be mounted inside a mains rated enclosure. DO NOT connect the DALI Gateway to mains power. The unit is powered from the C-Bus network. The Gateway unit does not supply power to the C-Bus network or to the DALI networks. 5 of 12

6.0 Connection to the C-Bus Network Installation requires connection to the unshielded twisted pair C-Bus network cable. It is required that Category 5 data cable is used, Clipsal cat. number 5005C305B. Two RJ45 connectors are provided for upstream and downstream network attachment. The C-Bus network uses pink Cat.5e, polarised 15-36 Volt, twisted-pair cable, catalogue number 5005C305B (solid) and 5005C305BST (stranded). RJ Pin C-Bus Connection Colour 1 Remote ON Green/White 2 Remote ON Green 3 C-Bus Neg (-) Orange/White 4 C-Bus Pos (+) Blue 5 C-Bus Neg (-) Blue/White 6 C-Bus Pos (+) Orange 7 Remote OFF Brown/White 8 Remote OFF Brown Table 1. C-Bus network wiring colour codes Figure 1. RJ45 pin assignments for plugs and sockets 6 of 12

7.0 Network Burden The DALI Gateway product incorporates a software selectable network burden. The network burden can be enabled using the C-Bus Installation Software. A network burden may or may not be required to ensure correct operation of the C-Bus network. If in doubt, consult the C-Bus calculator (Network Design Verification Software Utility) before proceeding with the hardware installation. The graphical user interface (GUI) software is designed to prevent the burden from accidental selection. 8.0 C-Bus Side Programming Requirements The DALI Gateway product incorporates a C-Bus PC interface module for communications to the C-Bus network. Programming of the C-Bus side of the network interface can be done in the same manner as programming a standard PC interface. The DALI Gateway must be programmed to set a unique identification (unit address) and mode of operation on the C-Bus network. The C-Bus Installation Software can be used to configure all operational parameters. The DALI Gateway is programmed using C-Bus Toolkit Software. The C-Bus Toolkit is available for download from the Clipsal website (www.clipsal.com/cis). 9.0 Power Surges and Short Circuit Conditions The 5502DAL C-Bus DALI Gateway is not directly connected to the mains. Each unit incorporates transient protection circuitry, but additional external power surge protection devices should be used to enhance system immunity to power surges. It is strongly recommended that over-voltage equipment, such as the Clipsal 970, be installed at the switchboard. 10.0 Megger Testing Megger testing must never be performed on the C-Bus data cabling or terminals as it may degrade the performance of the network. Megger testing the mains wiring of an electrical installation that has C-Bus units connected will not cause any damage to C-Bus units. Since C-Bus units contain electronic components, the installer should interpret megger readings with due regard to the nature of the circuit connection. 11.0 Important Warning The use of any non C-Bus software in conjunction with the hardware installation, without the consent of Clipsal, may void any warranties applicable to the hardware. 7 of 12

12.0 Standards Complied The 5502DAL C-Bus DALI Gateway meets the following standards. Australian/New Zealand EMC and Electrical Safety Frameworks and Standards Regulation Standard Title EMC AS/NZS CISPR 22 Information technology equipment Radio disturbance characteristics (EMC) Safety AS/NZS 61347-2-11 Particular requirements - miscellaneous electronic circuits used with luminaires European Directives and Standards European Council Directive EMC Directive 2004/108/EC Standard Title EN 55022 Information technology equipment Radio disturbance characteristics EN 55024 Information technology equipment Immunity characteristics Safety EN 61347-2-11 Particular requirements miscellaneous electronic circuits used with luminaires Low voltage Directive 2006/95/ EC RoHS 2002/95/EC Lighting equipment Electrical, mechanical, chemical and all other risks Reduction of hazardous substances European Directives and Standards European Standard Title Council Directive EMC CISPR 22 Information technology equipment Radio disturbance characteristics Immunity CISPR 24 Information technology equipment Immunity characteristics Safety IEC 61347-2-11 Particular requirements miscellaneous electronic circuits used with luminaires 8 of 12

13.0 Product Specifications Parameter Catalogue No. C-Bus Input Voltage C-Bus Current Drawn C-Bus AC input impedance Electrical isolation C-Bus Side Terminal DALI Side Terminals Maximum Devices Connected to C-Bus Network Mounting type Max number of DALI addressable units System clock and burden Operating Temperature Range Operating Humidity Range Weight Dimensions (mm) Value 5502DAL 15 36V d.c. 32mA from the C-Bus network. The Gateway does not provide power to the network. 50 kω at 1 khz 3.75 kv RMS for 1 minute between C-Bus and the DALI networks RJ45 connectors (2 of) Screw terminals 50 units DIN rail 64 per DALI network Software selectable 0-45 O C 10-95% RH 130g 72 (L) x 85 (W) x 65 (D) 9 of 12

14.0 Mechanical Specifications All dimensions are in millimetres. No user serviceable parts inside. 10 of 12

15.0 Two Year Warranty The 5502DAL C-Bus Dali Gateway carries a two year warranty against manufacturing defects. Warranty Statement The benefits conferred herein are in addition to, and in no way shall be deemed to derogate; either expressly or by implication, any or all another rights and remedies in respect to the Clipsal by Schneider Electric product, which the consumer has in the location where the product is sold. The warrantor is Schneider Electric (Australia) Pty Ltd with offices worldwide. This Clipsal by Schneider Electric product is guaranteed against faulty workmanship and materials for a period of two (2) years from the date of installation. Schneider Electric reserves the right, at its discretion, to either repair free of parts and labour charges, replace or offer refund in respect to any article found to be faulty due to materials, parts or workmanship. This warranty is expressly subject to the Clipsal by Schneider Electric product being installed, wired, tested, operated and used in accordance with the manufacturer s instructions. Any alterations or modifications made to the product without permission of Schneider Electric (Australia) Pty Ltd may void the warranty. Schneider Electric (Australia) Pty Ltd shall meet all costs of a claim. However, should the product that is the subject of the claim be found to be in good working order, all such costs shall be met by the claimant. When making a claim, the consumer shall forward the Clipsal by Schneider Electric product to the nearest Clipsal by Schneider Electric office. Provide adequate particulars of the defect withing 28 days of the fault occurring. The product should be returned securely packed, complete with details of the date and place of purchase, description of load, and circumstances of malfunction. For all warranty enquiries, contact your local Clipsal or Schneider Electric sales representative. The address and contact number of you nears sales office can be found at www.clipsal.com/locations or by calling CIS Technical support on 1300 722 247. 11 of 12

16.0 Technical Support and Troubleshooting For further assistance in using this product, consult your nearest Clipsal Sales Representative or Technical Support Officer. Technical Support Contact Numbers Australia New Zealand Northern Asia South Africa Southern Asia United Kingdom 1300 722 247 (CIS Technical Support Hotline) 0800 888 219 (CIS Technical Support Hotline) 852 2484 4157 (Schneider Electric Hong Kong) (011) 314 5200 (C-Bus Technical Support) 603 7665 3555 Ext. 236 or 242 (CIS Malaysia) 0870 608 8 608 (Schneider Electric Support) Technical Support Email: cis.support@clipsal.com.au Sales Support Email: sales.cis@clipsal.com.au Information and resources are provided at http://www.clipsal.com/cis/ Schneider Electric (Australia) Pty Ltd Contact us: clipsal.com/feedback National Customer Care Enquiries: Tel 1300 2025 25 Fax 1300 2025 56 Schneider Electric (Australia) Pty Ltd reserves the right to change specifications, modify designs and discontinue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein. Trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. F1942/02 1036459 CLIPCOM 23308