Safety Instructions Micropilot FMR56/57

Similar documents
Safety Instructions Micropilot FMR50/51/52/53/54/56/57

Safety Instructions Cerabar S PMP71, PMP75

Safety Instructions Levelflex FMP50/51/52/53/54/55/56/57

Safety Instructions Cerabar M PMC51, PMP51, PMP55

Cerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus

Safety Instructions Proservo NMS80, NMS81, NMS83

Safety Instructions Omnigrad TRxx, TCxx, TxCxxx

PI-EX-ME-2NAM/COC-24VDC

DR7100 SERIES Supplementary instructions

PHOENIX CONTACT - 12/2007

PI-EX-ME-2NAM/COC-120VAC

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

SMARTLINE RM76 Supplementary instructions

BA01236F/00/EN/ Products Solutions Services. ToF Adapter FXA291

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Inductive sensor NI3-EG08K-Y1-H1341

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Functional safety manual Liquiphant M/S with FEL58 and Nivotester FTL325N

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI5-EM18-Y1X-H1141

Safety instructions Overvoltage protection B81-35

Safety instructions VEGATOR 121, 122

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

EX- Documentation VA 450 / VA 452. thermal mass flow sensor

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Refer to attachment for more details. Andreas Meyer

Technical Data. General specifications. Output type Rated operating distance s n 8 mm

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

5 Fieldbus Technology

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Special Documentation Liquicap M FMI51, FMI52

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Interface and Supply module. IPC 3x0i / PSC 3x0i

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

Continuous level measurement Radar transmitters

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

Micropilot S FMR530/532/533, FMR540

Technical Information RIA16

MINI MCR-SL-PT100-UI(-SP)(-NC)

Technical Data. Dimensions

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

MANUAL Surge Protectors

PHOENIX CONTACT - 01/2008

IECEx Certificate of Conformity

Operating Instructions

Operating Instructions Soliswitch FTE20

MINI MCR-SL-PT100-UI-200

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

GRP Flameproof Visual Signal Xenon or Steady LED

Emergency power supply NV2.1-12iaE

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Resistance thermometer With spring-loaded tip Model TR55

Intrinsically safe batch controller Batching Master 110i

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

MINI MCR-SL-MUX-V8-FLK 16

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Technical Information RIA16

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Replacing Spare Parts

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

M E M O R A N D U M I.S.

Technical Information Promonitor NRF560

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

MACX MCR-EX-SD LP(-SP)

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

PHOENIX CONTACT - 05/2007

Power supply unit NG3-16ib

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Manual Mouse Module CHALLENGER Mi-PS2 / Mi-PS2-B

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

Zener Barriers Bulletin 937Z

Level switch for tank installation. NT 61-Z0-Atex. Installation and Operation Instructions. Original instructions. Fluidcontrol BE /2017

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

PHOENIX CONTACT - 02/2008

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Operating Instructions Micropilot FMR56, FMR57

LS 6600 Technical Datasheet

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

Rosemount 248 Wireless Temperature Transmitter

Transcription:

XA01299F-A/00/EN/01.14 71252565 Products Solutions Services Safety Instructions FMR56/57 PROFIBUS PA, FOUNDATION Fieldbus Ex ta IIIC T 500 xx C Da Segurança TÜV INMETRO OCP 0004 Document: XA01299F-A Safety instructions for electrical apparatus for explosion-hazardous areas

XA01299F-A 2 Endress+Hauser

XA01299F-A FMR56/57 PROFIBUS PA, FOUNDATION Fieldbus Table of Contents Associated documentation................................................... 4 Supplementary documentation............................................... 4 Manufacturer's certificates................................................... 4 Extended order code........................................................ 4 Safety instructions: General.................................................. 5 Safety instructions: Special conditions......................................... 6 Safety instructions: Installation............................................... 6 Temperature tables......................................................... 6 Connection data............................................................ 7 Endress+Hauser 3

XA01299F-A Associated documentation This document is an integral part of the following Operating Instructions: PROFIBUS PA: BA01127F/00 (FMR56/57) FOUNDATION Fieldbus: BA01123F/00 (FMR56/57) The Operating Instructions pertaining to the device apply. Supplementary documentation Explosion-protection brochure: CP00021Z/11 The Explosion-protection brochure is available: In the download area of the Endress+Hauser website: www.endress.com Download Advanced Documentation Code: CP00021Z On the CD for devices with CD-based documentation Manufacturer's certificates Certificate of Conformity Certificate number: TÜV 13.2010 X Affixing the certificate number certifies conformity with the standards under www.abnt.org.br (depending on the device version). ABNT NBR IEC 60079-0 : 2008 ABNT NBR IEC 60079-11 : 2009 ABNT NBR IEC 60079-31 : 2011 Extended order code The extended order code is indicated on the nameplate, which is affixed to the device in such a way that it is clearly visible. Additional information about the nameplate is provided in the associated Operating Instructions. Structure of the extended order code FMR5x - ************* + A*B*C*D*E*F*G*.. ---------------- ----------------------- --------------------------- Device type Basic specifications Optional specifications * = Placeholder At this position, an option (number or letter) selected from the specification is displayed instead of the placeholders. Basic specifications The features that are absolutely essential for the device (mandatory features) are specified in the basic specifications. The number of positions depends on the number of features available. The selected option of a feature can consist of several positions. Optional specifications The optional specifications describe additional features for the device (optional features). The number of positions depends on the number of features available. The features have a 2-digit structure to aid identification (e.g. JA). The first digit (ID) stands for the feature group and consists of a number or a letter (e.g. J = test, certificate). The second digit constitutes the value that stands for the feature within the group (e.g. A = 3.1 material (wetted parts), inspection certificate). More detailed information about the device is provided in the following tables. These tables describe the individual positions and IDs in the extended order code which are relevant to hazardous locations. 4 Endress+Hauser

XA01299F-A Device type: FMR56, FMR57 Basic specifications Position Selected option Description 1, 2 Approval FMR5x ME * 1 Ex ta IIIC T 500 xx C Da 3 Power Supply; Output FMR5x E G 2-wire, FOUNDATION Fieldbus, switch output (PFS) 2-wire, PROFIBUS PA, switch output (PFS) 4 Display; Operation FMR5x A C E L M Without, via communication SD02 4-line, push buttons + data backup function SD03 4-line, illum., touch control + data backup function Prepared for display FHX50 + M12 connection Prepared for display FHX50 + custom connection 5 Housing FMR5x C Dual compartment, Alu coated (GT20) FMR57 B Dual compartment, 316L (GT18) 7, 8 Antenna FMR56 BN BR Horn 80 mm/3", PP cladded, 40...80 C Horn 100 mm/4", PP cladded, 40...80 C FMR57 Bx Fx Horn (different sizes) Parabolic (different sizes) 9, 10 Seal FMR57 A6 D4 Viton GLT, 40...200 C Graphite, 40...400 C (HT) 11-13 Process Connection FMR56 UAE XR0 XxG Mounting bracket Connection, without flange/mounting bracket Slip on flange (different sizes) FMR57 Axx, Cxx, Kxx RxJ XxJ Flange (different sizes) Thread, 316L Align. device (different sizes) * 1 The designation changes in connection with "Display; Operation" = "L" or "M": Ex ta [ia] IIIC T 500 xx C Da Optional specifications ID Selected option Description Ox Accessory Mounted FMR57 OW Horn protection, PTFE, no airpurge possible Safety instructions: General Staff must meet the following conditions for mounting, electrical installation, commissioning and maintenance of the device: Be suitably qualified for their role and the tasks they perform Be trained in explosion protection Be familiar with national regulations Install the device according to the manufacturer's instructions and national regulations. Do not operate the device outside the specified electrical, thermal and mechanical parameters. Only use the device in media to which the wetted materials have sufficient durability. Avoid electrostatic charging: Of plastic surfaces (e.g. housing, sensor element, special varnishing, attached additional plates,..) Of isolated capacities (e.g. isolated metallic plates) Refer to the temperature tables for the relationship between the permitted ambient temperature for the sensor and/or transmitter, depending on the range of application, and the temperature class. Modifications to the device can affect the explosion protection and must be carried out by staff authorized to perform such work by Endress+Hauser. After mounting and connecting the antenna, ingress protection of the housing must be at least IP65. Perform the following to achieve the degree of protection: Screw the cover tight. Mount the cable entry correctly. Endress+Hauser 5

+ XA01299F-A Safety instructions: Special conditions Permitted ambient temperature range at the electronics housing: 40 C T a +80 C. Observe the information in the temperature tables. Device type FMR57 and Optional specification, ID Ox (Accessory Mounted) = OW An antenna coated with non-conductive material can be used if avoiding electrostatic charging (e.g. through friction, cleaning, maintenance, strong medium flow). In the case of process connections made of polymeric material or with polymeric coatings, avoid electrostatic charging of the plastic surfaces. In the event of additional or alternative special varnishing on the housing or other metal parts: Observe the danger of electrostatic charging and discharge. Do not rub surfaces with a dry cloth. Safety instructions: Installation A 3 2 4 5 1 5 6 å 1 A Zone 20, Zone 21 1 Tank; Zone 20, Zone 21 2 Electronics compartment Ex iad; Electronic insert 3 Connection compartment Ex t 4 Power supply 5 Potential equalization line 6 Potential equalization FMP5x_02 After aligning (rotating) the housing, retighten the fixing screw (see Operating Instructions). When mounting the device: Exclude any mechanical damage or friction during the application. Pay particular attention to flow conditions and tank fittings. Continuous service temperature of the connecting cable: 40 to +85 C; in accordance with the range of service temperature taking into account additional influences of the process conditions (T a,min ), (T a,max +20 K). Only use certified cable entries or sealing plugs. The metal sealing plugs supplied meet this requirement. Before operation: Screw in the cover all the way. Tighten the securing clamp on the cover. Intrinsic safety The device can be connected to the Endress+Hauser FXA291 service tool: refer to the Operating Instructions. Temperature tables 9 6 Endress+Hauser

XA01299F-A Connection data Basic specification, Position 1, 2 (Approval) = ME Connection compartment Ex t The power consumption of I/O modules with passive PFS output can be limited for certain applications. Recommended: Power consumption = 1 W. This is obtained for a supply voltage at the terminals of 27 V DC. For higher supply voltages (U max ): Insert a serial resistance (R V ) in order to limit the power consumption table below. Table for the PFS serial resitance (R V ): Power consumption Total power consumption Internal resistance R I 1.0 W 1.88 W 760 U max [V] R V min 35 205 34 177 33 150 32 122 31 95 30 67 29 39 28 12 27 0! Note! For values associated with a higher or lower internal power consumption please contact Endress+Hauser. Basic specification, Position 3 (Power Supply; Output) = E, G (TRC [27]) Terminal 1 (+), 2 ( ) Terminal 3 (+), 4 ( ) Power supply: U N = 32 V DC U m = 250 V Switch output (PFS): U N = 35 V DC U m = 250 V Electronics compartment Ex i Service interface (CDI) Taking the following values into consideration, the device can be connected to the certified Endress+Hauser FXA291 service tool or a similar interface: Service interface U i = 7.3 V effective inner inductance L i = negligible effective inner capacitance C i = negligible U o = 7.3 V I o = 100 ma P o = 160 mw L o (mh) = C o (μf) = 5.00 0.73 2.00 1.20 1.00 1.60 0.50 2.00 0.20 2.60 0.10 3.20 0.05 4.00 0.02 5.50 0.01 7.30 0.005 10.00 0.002 12.70 0.001 12.70 Endress+Hauser 7

XA01299F-A 8 Endress+Hauser

XA01299F-A Temperature tables Table of Contents General notes...................................................................... 10 Tables Antenna and electronics housing: Zone 20, Zone 21 FMR5x......................................................................... 11 Endress+Hauser 9

XA01299F-A General notes Unless otherwise indicated, the positions always refer to the basic specification. T a = Ambient temperature T 500 = Deposited material with a layer of 500 mm Selection table Position 1, 2 (Approval) Position 5 (Housing) ME Ex ta IIIC T 500 xx C Da B C GT18 dual compartment, 316L GT20 dual compartment, Alu coated Position 3 (Power Supply; Output) Transmission code of the terminal module Channels E G 2-wire, FOUNDATION Fieldbus, switch output (PFS) 2-wire, PROFIBUS PA, switch output (PFS) TRC [27] 1 or 2 channels used 10 Endress+Hauser

XA01299F-A Tables Antenna and electronics housing: Zone 20, Zone 21 FMR5x Position 3 (Power Supply; Output) = E, G (TRC [27]) Position 5 (Housing) = B, C 1 channel used 2 channels used T = T a +5 K T 500 = T a +19 K T = T a +20 K T 500 = T a +40 K Endress+Hauser 11

71252565 www.addresses.endress.com