Power Supply HARTING pcon

Similar documents
Power Supply HARTING pcon

PHOENIX CONTACT - 07/2006

MINI-PS AC/10-15DC/8

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Power supply CP-C 24/5.0

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

STEP-PS/1AC/24DC/1.75

TRIO-DIODE/12-24DC/2X10/1X20

RTU500 series Data Sheet Power Supply CP-E 24/2.5

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

PHOENIX CONTACT - 01/2007

QUINT-PS/ 1AC/24DC/ 5

Power supply CP-D 12/2.1 Primary switch mode power supply

Power supply CP-E 24/0.75 Primary switch mode power supply

Power supply CP-E 48/1.25 Primary switch mode power supply

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Power supply CP-E 24/10.0 Primary switch mode power supply

QUINT-PS AC/24DC/10

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Redundancy unit CP-A RU

STEP-PS/1AC/24DC/2.5. Extract from the online catalog. Order No.: DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase.

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

QUINT-PS-3x AC/24DC/10

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

Electronic timer CT-ERD.12

QUINT-BUFFER/24DC/24DC/40

ASI QUINT /2.4 EFD

QUINT-PS/ 1AC/24DC/20/CO

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

Electronic timer CT-AHD.22

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:

Extract from the online catalog

Output Voltage* (nom.)(adjustable)

QUINT-PS/24DC/48DC/ 5

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Switched-Mode Power Supplies. 5, 12, 18, 48 VDC Output

Electronic timer CT-ERS.21

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas QUINT-PS AC/24DC/5/EX

DC561, digital input/output module,

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

AI561 Analog Input Module

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

DC562, digital input/output module,

Electronic timer CT-ARS.11

Voltage Current Front-mounting bracket

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Power supply CP-C 24/5.0

DX561 Digital Input/Output Module

AO561 Analog Output Module

Output Voltage* (nom.)(adjustable)

Redundancy Module QUINT-DIODE/40

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

FL MC 2000E (SM40) LC

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

CD522 Encoder, Counter and PWM Module

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

DC541 Digital Input/Output Module

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

Contact protection relay

Uninterruptible power supply - TRIO-UPS/1AC/24DC/

DI572 Digital Input Module

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

AO523 Analog Input Module

ABL8WPS24400 regulated SMPS - 3-phase V - 24 V - 40 A

ABL8MEM12020 regulated SMPS - 1 or 2-phase V AC - 12 V - 2 A

20A DRR Module / 40A DRR Module

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

CI542 PROFIBUS Communication Interface Module

DI561 Digital Input Module

TU531, TU532 Terminal Unit

DeltaV Bulk Power Supplies

DC522 Digital Input/Output Module

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Industrial Power Supplies

onlinecomponents.com

Features. Applications and Benefits TRC ELECTRONICS, INC

Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1A

Installation Instructions

DC532-XC, digital input/output module,

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

Transcription:

HARTING pcon 2120 Advantages Compact design and high power density Easy installation and tool-less connection Wide input range for world-wide use Wide operating temperature range (up to 70 C without derating) Can be used directly in industrial environments Protection class II (no earth connection necessary) Proof against sustained short-circuits, overloads and no-load operation Proof against dynamic overload (150 % rated current for up to 3.0 seconds) International approvals General The power supplies of the HARTING pcon 2000 product family are designed as power supply solutions for control units, Ethernet and other automation components. With their wide range of input voltage, theunits are suitable for world-wide use. The quick connection technology and the 2 terminals per connection point guarantees easy and quick installation. Identification Part number HARTING pcon 2120-24 20 80 000 3124 All data given are in line with the actual state of art and therefore not binding. HARTING reserves the right to modify designs without giving the relevant reasons. Han Data sheet 1208

Identification Part number Drawing Dimensions in mm HARTING pcon 2120-24 20 80 000 3124 For mounting onto top-hat mounting rail according to DIN EN 60 715 Input Nominal input voltage 100 V AC / 230 V AC (wide range input) Input voltage tolerances according to IEC 61 131-2 and DIN 19 240 Input voltage range Input frequency Input Current I in Inrush current 85 to 264 V AC (100 to 375 V DC) 47... 63 Hz < 1.0 A at 230 V AC and < 2.0 A at 100 V AC < 40 A (active limitation) Leakage current < 0.7 ma (at 47... 63 Hz mains frequency and max. input voltage) Internal fuse T 4 AH / 250 V (not accessibly) Recommended back-up fuse 6 A, 10 A or 16 A characteristic B (EN 60 898) Transient surge protection according to VDE 0160 (varistor) Block Diagram: Page 2

Output Output voltage 24 V DC (setting range 23... 29 V) Accuracy ± 1 % over the total load and input voltage range Output current 5.0 A static 6.25 A (25 % over nominal load) dynamic for max. 7 seconds 7.5 A (50 % over nominal load) dynamic for max. 3.0 seconds Max. output power 120 W Ripple/Noise < 40 mvss (at = 264 V) Steady-state control accuracy < 2 % Overload behavior current limitation > 5.3 A static; > 10.0 A dynamic The device is electronically protected against short-circuit and no load operation. In the event of a malfunction, the output voltage is limited to 67 V DC. During overload the output voltage is reduced to approx. 34 V, a low-resistance connections induces hiccup mode to protect against the danger of fire. Uaus / VDC 25,0 20,0 15,0 10,0 U-I-Characteristic static and dynamic U-I-Kennlinie statisch und dynamisch t / s 12,0 10,0 8,0 6,0 4,0 5,0 2,0 0,0 0,0 0 2 4 6 8 10 12 l / A Mains buffering at nominal load (typical) Efficiency (typical at nominal load) Output voltage indication Turn-on time Resistance to reverse feed 100 ms at 230 V AC; 15 ms at 115 V AC = 230 V: 90.0 % / power dissipation (typ.) 14.7 W = 115 V: 89.6 % / power dissipation (typ.) 14.0 W = 100 V: 88.0% / power dissipation (typ.) 13.12 W LED green 600 ms after applying the mains voltage 35 V < 8 mf and Nennlast Page 3

General Data MTBF > 250.000 hours (according to IEC 1709, SN 29 500) Insulation co-ordination Isolation voltage Input / Output Type-/ routine test 3 kv AC Connectable in parallel yes, with redundancy module (decoupling diodes) Connection Primary: 2 x L1 / 2 x N (below) Secondary: 2 x U1 / 2 x GND (above) Conductor cross-sections Stranded conductor: 0.3... 2.5 mm² (AWG 28... 12) Solid conductor: 0.3...4.0 mm² (AWG 28... 12) The connection can be made with or without screw driver (3 mm width), as shown in the following pictures 3-5 : make contacts 6-8 : break contacts Installation / Removal The power supply can be snapped onto a 35 mm mounting rail acc. to EN 60 715. The unit should be mounted at a slight angle from above onto the rail. Push down until the slide at the back of the unit snaps in (see diagram). The device must be mounted in such a way that the ventilation slots are not covered and air convection is unimpeded. Leave a space of at least 3 cm above and below the unit. The air temperature at the bottom of the unit must be not higher than the max. operating temperature (T u = 70 C)! Disconnect all cables before starting removal. To remove, first unlock the slide with a screwdriver and then take the unit away from the rail. Page 4

Design features Housing plastic enclosure anthracite-grey RAL 7016 Dimensions (W x H x D) 70 x 85 x 105 mm Mounting 35 mm DIN rail according to DIN EN 60 715 Weight approx. 500 g Degree of protection acc. to DIN 60 529 IP 20 Class of protection II (no earth connection necessary) Environmental conditions Operating temperature -25 C to 70 C (without forced ventilation) Storage temperature -30 C to +85 C Relative humidity 30 % to 95 % (non-condensing) Mechanical stability Shock IEC 60 068-2-27 Vibration IEC 60 068-2-6 Product standards EN 50 178 (VDE 0160) EN 60 950 (SELV) EN 60 204 (PELV) EMC standards Interference immunity ESD IEC 61 000-4-2 Interference immunity HF, radiated IEC 61 000-4-3 Interference immunity Burst IEC 61 000-4-4 Interference immunity Surge IEC 61 000-4-5 Interference immunity IEC 61 000-4-6 Emitted radiation EN 55 011, (EN 55 022) Class B System perturbation IEC 61 000-3-3 Rail standard EN 50 121-3-2 Approvals Conforms to EMC guideline 89/336/EEC and low voltage directive 2006/95/EG Electrical safety of information IEC/EN 60 950, UL 60 950, CSA 22.2-60 950 technology equipment CCSA-NRTL/C HARTING Electric GmbH & Co. KG 2008-12-08 Wilhelm-Harting-Straße 1 D-32339 Espelkamp Postfach 14 73 D-32328 Espelkamp Phone: +49 5772 47-97100 Fax: +49 5772 47-688 HARTING.Electric@HARTING.com www.harting.com