Leased-Line Extenders over IP

Similar documents
T1/E1 Channelized Gigabit Router

Enterprise Session Border Router

Multi-Port T1/E1/PRI VoIP Enterprise Gateway Router

SIP 3CX Based Private Branch Exchange

VPN Routers. OnSite 2800 Series. Quick Start Guide

SmartNode 4830 DSL Series Analog VoIP Integrated Access Device Quick Start Guide

Enterprise Session Border Router, IAD

Metro-Optical Transport Access Nodes

Optical Multiplexer. Quick Start Guide

G.SHDSL IAD. iprocketlink Model Quick Start Guide

NanoServ. Setup Guide. Thin System/Ultra-Thin System. 1.0 What s included with the NanoServ. 2.0 Steps for setting up the NanoServ

Single/Dual-Port ISDN BRI VoIP Terminal Adapter

G.SHDSL NTU DECEMBER 2006 LB510A

Ethernet Extender. EnviroNET 2100 Series. Quick Start Guide

Multiport Analog VoIP Router

G.SHDSL NTU with Fixed Serial Interfaces

SmartNode 2290 Series Leased-Line Extenders over IP

Multi-Port T1/E1/PRI VoIP Enterprise Session Border Router

OpenScape Business Appliance

Multi-Port T1/E1/PRI Enterprise VoIP Media Gateway

ADSL2+ Multiport ISDN VoIP IAD

EFM Router. OnSite Model Quick Start Guide

SmartNode 4900 IpChannel Bank

Serial G.SHDSL Bridge/Router

USER MANUAL MODEL CopperLINK Ethernet Extender. This is a Class A device and is not intended for use in a residential environment.

SmartNode 4830 DSL Series Analog VoIP Integrated Access Device

USER MANUAL MODEL CopperLINK High Speed Ethernet Extenders

SmartNode 1000 and 2000 Series

Installing the Cisco ATA

Ethernet Extender. Quick Start Guide

SmartNode 1000 and 2000 Series

SmartNode 4980 & 4990 Series

SmartNode 5480 & 5490 Series Enterprise Session Border Router, IAD

Internet Telephony PBX System. (30/100/500 SIP Users Registrations) IPX-330 / IPX-2100 / IPX Quick Installation Guide

TA Series Analog VoIP Gateway Installation Guide

24-Port Gigabit Ethernet Switches

Installing and Managing the Switch

InnoMedia Business VoIP ATA Models

Installing the Cisco 2524 and Cisco 2525 Routers

Diamond Edge Model 3224 G.SHDSL IpDSLAM

SmartNode 4960 Series

USER MANUAL MODELS 2156 & CopperLink Ethernet Extenders SALES OFFICE (301) TECHNICAL SUPPORT (301)

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.

Internet Telephony Gateway VGW-402 / VGW-400FS / VGW-400FO. Quick Installation Guide

MODEL 805 USER MANUAL

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

Installing the Cisco AS5400XM Universal Gateway

OnSite Model 3088A/I G.SHDSL.bis EFM CPE

High Power over Ethernet Midspans PD Port Model PD Port Model

Internet Telephony PBX System. (30/100/200/500 SIP Users Registrations) IPX-330/IPX-2100/IPX-2200/IPX Quick Installation Guide

OnSite 3210 Series G.SHDSL VPN Router

4170 POS System Installation Guide

User Guide TL-SG1024D 24-Port Gigabit Desktop/Rackmount Switch

MediaPack 1xx Analog VoIP Gateway

AX3000 Platine Terminal Ethernet TCP/IP

Codian IP VCR IP VCR 2200 Series

Installation. Package Contents CHAPTER

Micro-Switch/ port 10/100Mbps. Desktop Fast Ethernet Switch. (Auto MDI/MDIX) FEP T- 3 USER S MANUAL

AX3000 Platine Terminal Ethernet TCP/IP

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

Installation Manual for D1800 Series High Power PoE Midspan Power Supply

Aruba 3000 Multi-Service Mobility Controller Series. Installation Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide

10/100/1000Mbps. Gigabit Ethernet Switch GSW-2401/GSW User's Manual

GSW-1657 GSW User's Guide. 16/24-port Gigabit Ethernet Switch. Ver

TIME SERVER NETSILON. Quick start.

Rack Mount Power Supplies

Preparing to Install the Cisco AS5350XM Universal Gateway

Installing the Cisco Unified Videoconferencing 3545 MCU

APC100. User Manual.

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

SmartNode 4630 Series

SmartNode 4950-NCE Series Multi-Port T1/E1/PRI VoIP Enterprise Gateway Router

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

IpLink 2888 T1/E1 Multi-Megabit Inverse Mux

OnSite 2888 T1/E1 Multi-Megabit Inverse Mux

MC 11 EB-2 Power supply cabinet with external bus, AC version

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Tilgin Home Gateway HG321/HG322 HG320 Series Quick Guide

BiPAC 7404V Series. VoIP/ (802.11g) ADSL2+ (VPN) Firewall Router. Quick Start Guide

Yeastar S300 VoIP PBX. Installation Guide

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

24-Port 10/100Mbps + 2-Port. Gigabit Ethernet Switch FGSW User s Manual

NETWORKS S2800 & S3900 SERIES SWITCHES USER MANUAL

VoIP Gateway Routers. SmartNode 452X and 411X Series. Quick Start Guide

Start Here. Features. Model DS108 Dual Speed Hub Installation Giude

Rubber Foot Pads. Rackmount Kit VAC 50/60Hz Power Adapter

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Cisco SRP500 Series Services Ready Platforms (SRP540 Models)

SmartNode 5400 Series Enterprise Session Border Router

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

C2000 and C4000 Hardware Quick Start Guide

Fast Ethernet Switch AT-FS705L. Installation Guide Rev. A

Preparing to Install the VG248

VAC 50/60Hz Power Adapter

Yeastar S100 VoIP PBX

Catalyst 2360 Switch Getting Started Guide

USER MANUAL MODEL Bidirectional (IEEE-1284) Line Driver/Converter

Transcription:

SmartNode 2290 Series Leased-Line Extenders over IP Quick Start Guide Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved for use in an industrial or residential environment. Part Number: 07M2292-QS, Rev. B Revised: February 9, 2012 Sales Office: +1 (301) 975-1000 Technical Support: +1 (301) 975-1007 E-mail: support@patton.com WWW: www.patton.com

WARNING This device contains no user serviceable parts. The equipment shall be returned to Patton Electronics for repairs, or repaired by qualified service personnel. Mains Voltage: Do not open the case when the power cord is connected. For systems without a power switch, line voltages are present within the power supply when the power cord is connected. The external power adapter shall be a listed Limited Power Source. Ensure that the power cable used meets all applicable standards for the country in which it is to be installed, and that it is connected to a wall outlet which has earth ground. The mains outlet that is utilized to power the devise shall be within 10 feet (3 meters) of the device, shall be easily accessible, and protected by a circuit breaker. Hazardous network voltages are present in WAN ports regardless of whether power to the SmartNode is ON or OFF. To avoid electric shock, use caution when near WAN ports. When detaching cables, detach the end away from the SmartNode first. Do not work on the system or connect or disconnect cables during periods of lightning activity. Before opening the chassis, disconnect the telephone network cables to avoid contact with telephone line voltages. 1.0 Installing the SmartNode extender 1.1 Mounting the SmartNode extender Place the extender on a desktop or similar sturdy, flat surface that offers easy access to the cables. The extender should be installed in a dry environment with sufficient space to allow air circulation for cooling. For proper ventilation, leave at least 2 inches (5 cm) to the left, right, front, and rear of the SmartNode extender. 1.2 Connecting cables WARNING Do not work on the system or connect or disconnect cables during periods of lightning activity. The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and mechanical serviceability. Install the cables in the following order: 1. Installing the RJ-11 voice port cable or cables (see 1.3 Installing an interface cable on the extender s voice ports on page 3) 2 SmartNode 2290 Series Quick Start Guide

ETH 0/1 ETH 0/0 Ethernet connectors Voice ports, 1.25A Reset ETH 0/1 ETH 0/0 2. Installing the 10/100 Ethernet port cable or cables (see 1.4 Installing the Ethernet cable on page 5) 3. Installing the power input (see 1.5 Connecting to external power source on page 6) 1.3 Installing an interface cable on the extender s voice ports The SmartNode extender comes with at least two voice ports (see figure 1) located on the back of the extender. The voice ports are connected to analog devices via cables (see figure 2 and figure 3) terminated with RJ-11 connectors (see figure 4 and Table 1 on page 4 for pin-out information). Figure 1. Rear view showing location of Ethernet connectors and voice ports (SmartNode 2294 shown), 1.25A Reset RJ-11, male RJ-11, male Figure 2. FXS connection SmartNode 2290 Series Quick Start Guide 3

, 1.25A Reset ETH 0/1 ETH 0/0 PSTN wall plate RJ-11, male RJ-11, male Figure 3. FXO connection SmartNode 2294 Leased-Line Extender Over IP Console Power Run VoIP Enet 0 Enet 1 0/0 0/1 0/2 0/3 1 2 3 4 5 6 6 5 4 3 2 1 Socket Plug Figure 4. RJ-11 pinout diagram Table 1. RJ-11 socket Pin Signal 3 Ring (-) 4 Tip (+) Note Unit must not connect directly to telecom network voltage (TNV). 4 SmartNode 2290 Series Quick Start Guide

ETH 0/1 ETH 0/0 1.4 Installing the Ethernet cable The SmartNode 2292 Series has automatic MDX (auto-cross-over) detection and configuration on the Ethernet ports. Any of the two ports can be connected to a host or hub/switch with a straight-through wired cable (see figure 5). Ethernet devices (10Base-T or 100Base-T) are connected to the SmartNode s Ethernet ports (see table 2 for port pin-out listing) via a cable terminated with RJ-45 plugs. Because the SmartNode 2294 Series does not have the MDX feature, a cross-over cable is required when connecting SmartNode 2294 Series devices to a host (see figure 6). Table 2. Ethernet 10/100Base-T (RJ-45) port pin-outs (SmartNode 2294 Series) Note Pins not listed are not used., 1.25A Reset Hub Straight-through cable Pin Signal 1 TX+ 2 TX- 3 RX+ 6 RX- RJ-45, male Tx+ 1 Tx- 2 Rx+ 3 Rx- 6 RJ-45, male 1 Rx+ 2 Rx- 3 Tx+ 6 Tx- Figure 5. Connecting a SmartNode 2294 Series device to a hub SmartNode 2290 Series Quick Start Guide 5

, 1.25A Reset ETH 0/1 ETH 0/0 Host Twisted pair 1 Twisted pair 2 RJ-45, male Tx+ 1 Tx- 2 Rx+ 3 Rx- 6 Cross-over cable Figure 6. Connecting to a host RJ-45, male 1 TX+ 2 TX- 3 RX+ 6 RX- 1.5 Connecting to external power source The extender comes with an external power supply. This section describes installing the power cord into the extender. Do the following: Note Do not connect the power cord to the power outlet at this time. 1. Insert the barrel type connector end of the AC power cord into the external power supply connector. CAUTION The extender power supply automatically adjusts to accept an input voltage from 100 to 240 VAC (50/60 Hz). Verify that the proper voltage is present before plugging the power cord into the receptacle. Failure to do so could result in equipment damage. 2. Verify that the AC power cord included with your extender is compatible with local standards. If it is not, contact Patton to find out how to replace it with a compatible power cord. 3. Connect the male end of the power cord to an appropriate power outlet. 4. Verify that the green Power LED is lit. 2.0 Configuring the SmartNode extender Patton SmartNodes can be used for a wide variety of IP-based network applications. To support and ease the configuration of the SmartNodes configuration, templates for the most important applications are available on the Patton server at www.patton.com/voip. The main steps for setting up a new SmartNode are shown in figure 7. 6 SmartNode 2290 Series Quick Start Guide

Run 0/0 0/1 0/2 0/3 Run 0/0 0/1 0/2 0/3 Run 0/0 0/1 0/2 0/3 1 Configure IP address Power VoIP Enet 0 Enet 1 SmartNode 2294 Leased-Line Extender Over IP Console Console port Serial interface PC or workstation with VT-100 emulation terminal 2 Connect the SmartNode to the network Power VoIP Enet 0 Enet 1 SmartNode 2294 Leased-Line Extender Over IP Console Ethernet interface ETH0 PC or workstation or VT-100 emulation terminal 3 Load configuration 3. Load configuration 2. Modify configuration SmartNode 2294 Leased-Line Extender Over IP Console 1. Download configuration example Power VoIP Enet 0 Enet 1 Note You can manually configure the SmartNode. You do not have to load a configuration file. Figure 7. Steps for setting up a new SmartNode Internet Patton Web server with configuration examples 2.1 Configure the IP address Power connection and default configuration First the SmartNode must be connected to the mains power supply with the power cable. Wait until the 'Run' LED stops blinking and lights constantly. Now the SmartNode is ready. The factory default configuration for the Ethernet interface IP addresses and network masks are listed in table 3. Table 3. Factory default IP address and network mask configuration IP Address Network Mask Interface Ethernet 0 (ETH0) DHCP DHCP Interface Ethernet 1 (ETH1) 192.168.1.1 255.255.255.0 Both Ethernet interfaces are activated upon power-up. SmartNode 2290 Series Quick Start Guide 7

Connect with the serial interface The Console port is wired as an EIA-561, RS-232 port. Use the included Model 16F-561 adapter and cable (see figure 8) between the SmartNode s Console port and a PC or workstation s RS-232 serial interface. Activate the terminal emulation program on the PC or workstation that supports the serial interface (e.g. HyperTerm). SmartNode 2294 Leased-Line Extender Over IP Console Serial Terminal Power Run VoIP 0/0 0/1 0/2 Enet 0 Enet 1 0/3 Note A Patton Model 16F-561 RJ45 to DB-9 adapter is included with each SmartNode Series device Figure 8. Connecting to the terminal Terminal emulation program settings: 9600 baud no parity 8 bit 1 stop bit 1 start bit No flow control 8 SmartNode 2290 Series Quick Start Guide

2.2 Login 1. Accessing your SmartNode via the local console port (or via a Telnet session) causes the login screen to display. Type the factory default login: administrator and leave the password empty. Press the Enter key after the password prompt. login:administrator password: <Enter> 172.16.40.1> 2. After you have successfully logged in you are in the operator execution mode, indicated by > as command line prompt. With the commands enable and configure you enter the configuration mode. 172.16.40.1>enable 172.16.40.1#configure 172.16.40.1(cfg)# 3. Enter the following commands for the first SmartNode 229x device in the pair: Copy nvram:a-side-config startup-config Copy running-config startup-config 4. Follow the same procedure for the other SmartNode 229x device in the pair: Copy nvram:b-side-config startup-config Copy running-config startup-config Note The configuration above is only a sample configuration that you may use as an example. You should specify your own parameters such as your IP address and other related information as required. For detailed information on all configuration parameters, refer to the SmartWare Software Configuration Guide available online at www.patton.com/smartnode. 5. Reboot both units and connect them back-to-back through their Ethernet 0/1 ports. Voice connections will automatically be set up between the units. The steps above will configure the IP addresses as well as the required configurations for voice connections. SmartNode 2290 Series Quick Start Guide 9

3.0 Additional Information For detailed information about configuring and operating guidance, set up procedures, and troubleshooting, refer to the SmartNode 2290 Series User Manual available online at www.patton.com/manuals/ SN2290.pdf and the SmartWare Software Configuration Guide available online at www.patton.com/ smartnode. A.0 Customer and Technical Support Toll-Free VoIP support: call sip:support@patton.com with a VoIP SIP client Online support: www.patton.com E-mail support: support@patton.com answered within 1 business day Telephone support: Standard: +1 (301) 975-1007 (USA), Monday Friday: 8:00 am to 5:00 pm EST (1300 to 2200 UTC/GMT) Alternate: +41 (0)31 985 25 55 (Switzerland), Monday Friday: 8:00 am to 5:00 pm CET (0900 to 1800 UTC/GMT) Fax: +1 (253) 663-5693 (USA) or +41 (0)31 985 25 26 (Switzerland) 10 SmartNode 2290 Series Quick Start Guide

B.0 Compliance Information B.1 Compliance EMC Compliance: EN55022, Class A EN55024 Safety Compliance: EN60950 B.2 CE Declaration of Conformity This equipment conforms to the requirements of Council Directive 1999/5/EC on the approximation of the laws of the member states relating to Radio and Telecommunication Terminal Equipment and the mutual recognition of their conformity. The safety advice in the documentation accompanying this product shall be obeyed. The conformity to the above directive is indicated by CE sign on the device. The signed Declaration of Conformity can be downloaded at www.patton.com/certifications. SmartNode 2290 Series Quick Start Guide 11

Copyright statement Copyright 2012, Patton Electronics Company. All rights reserved. The information in this document is subject to change without notice. Patton Electronics assumes no liability for errors that may appear in this document. Trademarks statement The term SmartNode is a trademark of Patton Electronics Company. All other trademarks presented in this document are the property of their respective owners. Warranty For warranty, trademark and compliance information, refer to the SmartNode 2290 Series User Manual located online at www.patton.com/manuals. In accordance with the requirements of council directive 2002/96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling. 12 SmartNode 2290 Series Quick Start Guide