USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Similar documents
An ISO-9001 Certified Company

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem

USER MANUAL. MODEL 2014 Interface Powered RS-530 to V.35 Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL Bidirectional (IEEE-1284) Line Driver/Converter

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODELS 1205 and 1205/34. Synchronous V.35 Modem Eliminators

USER MANUAL MODEL 222N9. Ultra-miniature RS-232 (EIA-574) to RS-422 Interface Converter

USER MANUAL MODEL 505M-CHC. Surge Protected DB-25 to RJ-45 Modular Adapter

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

USER MANUAL. TS Series (Model 52X) Terminal Strip Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 515 DB-15 Surge Protector

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 503P & 503PC. Parallel Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 536S Token Ring (STP) Surge Protector. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 56X Series 564, 566, 568, 562. Hub Surge Protectors

USER MANUAL. MODEL 552 Series. High Speed Telco Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 570-R8/570-R R8/580-R Base-T (CAT-5) Surge Protectors

USER MANUAL MODEL 570/ Base-T (CAT-5) Surge Protectors SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODELS 2156 & CopperLink Ethernet Extenders SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL KiloModem II AC Powered, High-Speed X.21 Short-Range Modem

USER MANUAL MODEL CopperLink Ethernet Extender SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL User Network Access Bridge. SALES OFFICE (301) TECHNICAL SUPPORT (301)

DB9 Microdriver CUSTOMER SUPPORT INFORMATION JULY 1994 ME792A ME793A ME794A

USER MANUAL MODEL 571/ Base-T (CAT-5) Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1082 and 1082/144 idsl Modem with V.35 or X.21 Interface. An ISO-9001 Certified Company

USER MANUAL MODEL IM 1/I. Ethernet Bridge Module. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 1010RC. Miniature Short Range Modem with Transformer Isolation: Rack Mount Card

USER MANUAL MODEL CopperLINK High Speed Ethernet Extenders

USER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Instruction Guide. Two Port ISA Serial Card ISA2S550. The Professionals Source For Hard-to-Find Computer Parts

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

XC300 VDSL Network Extender Owners Manual

Ethernet Extender. EnviroNET 2100 Series. Quick Start Guide

USER MANUAL. MODEL 1090 High Speed Synchronous Short Range Modem. Dear Valued Customer,

SC532A 9-PIN PERIPHERAL TO RS232 INTERFACE INSTRUCTION MANUAL

e-ask electronic Access Security Keyless-entry RF Keyless-entry entry System TM-Multi Multi Installation Manual FCC ID: TV2EFOB1 (UM21 ~ )

Enclosure TS-530 User Manual

NanoServ. Setup Guide. Thin System/Ultra-Thin System. 1.0 What s included with the NanoServ. 2.0 Steps for setting up the NanoServ

COBALT C INSTALLATION GUIDE RFID CONTROLLER ESCORT MEMORY SYSTEMS. High Frequency Passive Radio Frequency Identification Controller

USB 2.0 Ranger High Speed Extender System. User Guide

Messager USB w/ Night Answer

1206P (CTS ME-X.21) MODEM ELIMINATOR, X.21 INSTALLATION AND OPERATIONS MANUAL. Doc #: UA Part #: 07M1206P-A

Interface Converter. Installation Manual IC485S IC485SGB IC485SEU. RS-232 to RS-485/422 Serial Interface Converter

Multi-Messager USB by Nel-Tech Labs, Inc. Installation & User Manual

MODEL 710. Ground Support Intercom INSTALLATION/OPERATION MANUAL

SIP 3CX Based Private Branch Exchange

CAT5-1600A Extender. EXT-CAT5-1600A User Manual.

and Network Interface Modules Installation Instructions

BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual

BTU 4 & Sensors. Installation and Operation Manual

USER MANUAL MODEL 1018RC. Powered High Speed Short Range Modem: Rack Mount Card

USER MANUAL MODEL CopperLINK Ethernet Extender. This is a Class A device and is not intended for use in a residential environment.

USB 2.0 Ranger Port USB m CAT 5e/6/7 Extender System. User Guide

Messager USB by Nel-Tech Labs, Inc. Installation & User Manual

Instruction Manual. Balanced Audio Upgrade Installation. iport IW-21/IW-22 Upgrade Kits. Balanced Audio Upgrade Kit. (iport IW-21)

USER MANUAL MODEL PeNet TM Miniature 10Base2 to Parallel Print Server SALES OFFICE (301) TECHNICAL SUPPORT (301)

Instruction Guide. 2 Channel Ultra ATA/100 PCI Card PCI2IDE100. The Professionals Source For Hard-to-Find Computer Parts. Revised: December 5, 2002

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

EXT-DVI-CAT5-4X User Manual

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack

USB 2.0 Ranger High Speed Extender System. User Guide

VGA RS-232 Extender USER MANUAL.

3.5 External IDE Drive Case

HDKVM ELR extension for HDMI and USB Over One CAT5

G.SHDSL NTU with Fixed Serial Interfaces

USB Ranger User Guide. Cat 5 USB 2.0 Extender with Remote Power. Powered by

ilink Installation & User Manual Internet Downloadable MP3 Music & Message Series

Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide

Ground Isolated RS422/RS485 Serial PCI Card DB9

PV3500. Fuel Site Controller. Service Manual OPW Fuel Management Systems Manual M Rev. 1

MPP200 User s Manual

EP/2 Installation Instructions

Residential/Light Commercial Remote Control System

CAT5-1600A Extender. EXT-CAT5-1600A. User Manual

PCI Serial Card 2 Port RS-422/RS-485 PCI Serial Card with Terminal Block Connectors PCI2S422TB Instruction Manual Actual product may vary from photo

Sonorous v2.0. Installation & User Manual

Instruction Guide. PCI 1-2 Port Serial Card PCI1S550 PCI2S550 PCI2S550_LP. The Professionals Source For Hard-to-Find Computer Parts

Installation Guide for Flex Tap

G.SHDSL IAD. iprocketlink Model Quick Start Guide

MODEL 210 RADIO COMMUNICATION SYSTEM INSTALLATION & OPERATION MANUAL

Infosystem Remote Touchscreen Installation Instructions

DVI Extra Long Range Extender

Gefen. Extender for HDMI 3DTV GTB-HDMI-3DTV GTB-HDMI-3DTV-BLK. User Manual

Net-Ritef Continuity and Wiremap Tester Trace-Ritef Tone Generator and Amplified Tone Tracer User's Guide.

USB 2.0 CAT5E/6/7 EXTENDER

FA-2448 SIX POSITION Filter Wheel

Instruction Guide. Removable Drive Drawer for 3.5 SCSI 320 Hard Drives DRW150SCSI DRW150SCSIBK DRW150SCA DRW150SCABK

Instruction Guide. External 3.5" IEEE-1394b FireWire 800 and USB 2.0 Combination IDE Hard Drive Enclosure IDECASEU2FB

USER MANUAL. Model 2070 Series. V.24/X.21/V.35 to G.703 Interface Converter

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A

Instruction Guide. 4-Port IEEE 1394 FireWire Card With Digital Video Editing Kit PCI1394_4. The Professionals Source For Hard-to-Find Computer Parts

Miniature Asynchronous 4-Wire High Speed Modems

DVI Extra Long Range Extender

User Guide. USB/Ethernet Charging Cradle. Mobility Electronics, Inc Via Pasar, San Diego, CA 92126, USA

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

Boca s Family of Ethernet Products

Rev. A. ANC Series RS-485/RS-422 Synchronous Clock Display. Antona Corporation (818) URL:

NT1B-300 Rack Installation Instructions

ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved

Transcription:

USER MANUAL MODEL 1225 ParaLink TM Parallel Short Range Modem C E R T I F I E D An ISO-9001 Certified Company Part #07M1225-B Doc. #104011UB Revised 9/12/97 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com

1.0 WARRANTY INFORMATION Patton Electronics warrants all Model 1225 components to be free from defects, and will at our option repair or replace the product should it fail within one year from the first date of shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user. 1.1 RADIO AND TV INTERFERENCE 1.3 SERVICE All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Service at (301) 975-1007; http://www.patton.com: or, support@patton.com. NOTE: Packages received without an RMA number will not be accepted. Patton Electronics' technical staff is also available to answer any questions that might arise concerning the installation or use of your Model 1225. Technical Service hours: 8AM to 5PM EST, Monday through Friday. The Model 1225 generates and uses radio frequency energy, and if not installed and used properly that is, in strict accordance with the manufacturer's instructions may cause interference to radio and television reception. The Model 1225 is designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the Model 1225 does cause interference to radio or television reception, which can be determined by disconnecting the Model 1225 from both parallel interfaces, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches). 1.2 CE NOTICE The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). A Certificate of Compliance is available by contacting Patton Technical Support. 1 2

2.0 GENERAL INFORMATION Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to contact Patton Electronics Technical Support at (301) 975-1007. 2.1 FEATURES Extends parallel communication to 2000 feet Requires no AC power or batteries Operates over a single twisted pair Allows devices to communicate in real time Can be configured for BUSY or ACKNOWLEDGE flow control methods Compatible with most printer sharing devices Transmits DC power over the line to compensate for low power parallel printer interfaces DB-25 or Centronics parallel connections RJ-11, RJ-45 or terminal block line connections 3.0 CONFIGURATION The Model 1225 is designed to be easy to use. There are no internal jumpers or DIP switches to set, so there is no need to open the case to configure the unit (you may need to open the case for wire connection refer to Section 4.0). The only configuration necessary for operation is proper setting of the external BUSY / ACKNOWLEDGE switch. The diagram below shows the location of the BUSY / ACKNOWLEDGE switch on the PC board, as well as the location of the terminal block. BUSY/ ACKNOWLEDGE Switch Ack Busy G S Terminal Block 2.2 DESCRIPTION The Patton Electronics Model 1225 ParaLink TM parallel short range modem allows a PC and a parallel output device (printer, sharing switch, etc.) to communicate at distances to 2000 feet over a single unconditioned twisted pair. Supporting parallel data rates to 5 Kbytes per second (serial rates to 40 Kbps), the Model 1225 derives all necessary operating power from the parallel interface no AC power or batteries are required. The Model 1225 always works in pairs: A transmitter unit is plugged into the PC parallel port and a receiver unit is plugged into the output device parallel port. The connection between them is serial, and functions at speeds high enough to allow real time parallel communication between the two parallel devices. The Model 1225 has two unique features that allow it to operate in a wide variety of parallel applications: First, the Model 1225 transmitter is able to send DC power down the line to the receiver in order to compensate for low power parallel printer interfaces. Second, the Model 1225 can be configured for either BUSY or ACKNOWLEDGE flow control methods. The Model 1225 receiver is available with either a DB-25 or Centronics parallel interface (transmitter has DB-25 only). Line connection options are RJ-11, RJ-45 or terminal block with strain relief. 3 3.1 SETTING THE BUSY / ACKNOWLEDGE SWITCH For your convenience, the Model 1225 has an externally accessible BUSY / ACKNOWLEDGE switch (see diagram below). Set the switch on both transmitter and receiver as follows: Ack 1. The switch must be set the same way on both transmitter and receiver. 2. Set the switch to ACKNOWLEDGE on both the transmitter and reeiver. This should achieve good results in most applications. 3. If you experience loss of information or other problems with both switches set to ACKNOWLEDGE, set both switches to BUSY. 4 Busy

4.0 INSTALLATION Once you have configured the Model 1225 transmitter and receiver, you must connect the system. This section will tell you how to connect the transmitter and receiver via twisted pair wire and how to connect the two devices to your system hardware. 2. Strip the outer insulation from the twisted pairs about one inch from the end. 4.1 CONNECTING THE LINE SIDE Depending upon the type of units you have ordered, you can connect twisted pair wire to the Model 1225 using internal terminal blocks (with strain relief) or modular jacks. The following pages describe both kinds of twisted pair connection. 3. Strip back the insulation on each of the 2 wires about.25. 4.1.1 TERMINAL BLOCK CONNECTION Terminal blocks are used to connect a single pair of bare wires to the Model 1225. The following instructions will tell you how to open the case, connect the bare wires and fasten the strain relief collar in place. 4. Insert the two-wire data line to the center (signal) and shield (ground) terminal posts, then tighten the screws. 1. Open the unit by gently inserting a screwdriver between the DB-25 connector and the lip of the plastic case (see below). You don't have to worry about breaking the plastic, but be careful not to bend the D-sub connector. G S NOTE: Make sure the twisted pair cable between the transmitter and receiver is wired straight through as shown below: After you have opened the unit's case, you will find the terminal block mounted at the rear of the PC board. The terminals are labeled S for signal and G for ground. 5 SIGNAL (S)--------------------- (S) SIGNAL GROUND (G)--------------------- (G) GROUND 6

4. Place the 2 halves of the strain relief assembly on either side of the telephone wire and press together very lightly. Slide the assembly so that it is about 2 inches from the terminal posts and press together firmly. 6. BEND the top half of the case as necessary to place it over the strain relief assembly. Do not snap the case together yet. G S 7. Insert one captive screw through a saddle washer and then insert the entire piece through the hole in the DB-25 end of the case. Snap that side of the case closed. Repeat the process for the other side. This completes the installation process. 5. Insert the strain relief assembly and the wire into the slot in the bottom half of the modem case. Set it into the recess in the case. (If the telephone wire does not fit into the strain relief assembly, call Patton Electronics Technical Support at 301-975-1007. We have strain relief collars to suit a variety of cable diameters.) 4.1.2 RJ-11 & RJ-45 LINE CONNECTION When using the RJ-11 or RJ-45 modular jacks, install straight through cabling between the transmitter and receiver as shown below: RJ-11 JACKS SIGNAL PIN# COLOR COLOR PIN# SIGNAL DATA 3 Green --------------Green 3 DATA GND 4 Red------------------Red 4 GND RJ-45 JACKS SIGNAL PIN# COLOR COLOR PIN# SIGNAL G S DATA 4 Red -----------------Red 4 DATA GND 5 Green ---------------Green 5 GND 1 - Blue 2 - Yellow 3 - Green 4 - Red 5 - Black 6 - White 1 - Blue 2 - Orange 3 - Black 4 - Red 5 - Green 6 - Yellow 7 - Brown 8 - Slate Standard AT&T color codes yours may be different 7 8

4.2 CONNECTING TO PARALLEL HARDWARE After connecting the twisted pair line to the Model 1225 transmitter and receiver, you are ready to connect the units to your parallel hardware. The following steps explain this process: 1. Plug the DB-25 male connector on the Model 1225 transmitter directly into the parallel port of the sending device (which is normally a PC, terminal, host or similar DTE). Note: If you cannot plug the transmitter directly into the parallel port, use a straight through DB-25 parallel cable of the shortest possible length. We recommend 6 feet or less. 2. The Model 1225 receiver is available with either a DB-25 (male or female) or 36-pin Centronics (male only) connector. The DB-25 version is designed for direct connection to various print servers and switches. The Centronics version is designed for direct connection to the Centronics port of a parallel printer. Note: If you cannot plug the receiver directly into the port, use a straight through cable of the shortest possible length. We recommend 6 feet or less. 4.3 OPERATING THE MODEL 1225 Once the transmitter and receiver have been connected to each other and to their corresponding parallel input and output devices, you are ready to operate the units. Make sure that the BUSY/ACK switch on both units are placed on the same setting. Otherwise, the units should function transparently, just like a cable. There is no ON / OFF switch. Parallel Interface: Power: Range: Transmission: Line Interface: Data Rate: Interface Signals: APPENDIX A PATTON MODEL 1225 SPECIFICATIONS Transmitter, DB-25 male; Receiver, DB-25 male or female, 36-pin Centronics male Interface powered, no AC power or batteries needed 2,000 feet Half duplex over a single shielded or unshielded twisted pair (19-26 AWG) RJ-11, RJ-45 or terminal block with strain relief 5 Kbytes per second on parallel interface (40 Kbps on serial line) Dimensions: 2.67 x 2.10 x 0.74 Data bits 0-7, ground, Busy or Acknowledge (externally switch selectable) If your Model 1225 s are not operating properly, double-check all of your connections and try again. If you still experience problems, change the BUSY / ACKNOWLEDGE setting on both units and try again. If you still do not obtain satisfactory results, call Patton Technical Support at (301) 975-1007. 9 10

APPENDIX B PATTON MODEL 1225 PARALLEL PIN CONFIGURATIONS APPENDIX C PATTON MODEL 1225 BLOCK DIAGRAM (Transmitter) SOURCE TRANSMITTER / RECEIVER (DB-25) SOURCE Common Return / Ground -25 Common Return / Ground -24 Common Return / Ground -23 Common Return / Ground -22 Common Return / Ground -21 Common Return / Ground -20 Common Return / Ground -19 Common Return / Ground -18 Printer Error (Fault - Active LOW) 13- Select (Active HIGH) Printer 12- Paper End (Active HIGH) Printer 11- Busy (Active HIGH) Printer 10- Acknowledge (Active LOW) Printer 9- Data Bit 8 (MSB) Computer 8- Data Bit 7 Computer 7- Data Bit 6 Computer 6- Data Bit 5 Computer 5- Data Bit 4 Computer 4- Data Bit 3 Computer 3- Data Bit 2 Computer 2- Data Bit 1 (LSB) Computer 1- Data Strobe (Active LOW) Computer DIRECTION RECEIVER (CENTRONICS) DIRECTION -36-35 -34-33 Printer Fault (Active Low) -32-31 -30-29 -28-27 -26-25 -24-23 -22-21 -20-19 18- (+) 5 Volts Printer 17- Chassis Ground Common 16- Logic Ground Common 15-14- 13- Select (Active HIGH) Printer 12- Paper End (Active HIGH) Printer 11- Busy (Active HIGH) Printer 10- Acknowledge (Active High) Printer 9- Data Bit 8 (MSB) Computer 8- Data Bit 7 Computer 7- Data Bit 6 Computer 6- Data Bit 5 Computer 5- Data Bit 4 Computer 4- Data Bit 3 Computer 3- Data Bit 2 Computer 2- Data Bit 1 (LSB) Computer 1- Data Strobe (Active LOW) Computer 11 12

APPENDIX C (continued) PATTON MODEL 1225 BLOCK DIAGRAM (Centronics Receiver) APPENDIX C (continued) PATTON MODEL 1225 BLOCK DIAGRAM (DB25 Receiver) Copyright 1997 Patton Electronics Company All Rights Reserved 13 14