Omron FINS Ethernet Driver for JMobile

Similar documents
CODESYS V3 Ethernet Driver for JMobile

ABB Modbus RTU Driver for JMobile

CODESYS V2.3 Ethernet Driver for JMobile

Panasonic FP Serial Driver for JMobile

Mitsubishi FX Ethernet Driver for JMobile

Profibus DP Driver for JMobile

Mitsubishi FX Driver for JMobile

Modbus TCP Server Driver for JMobile

Modbus TCP Driver for JMobile

ROC Plus Communication Driver for JMobile

Control Techniques Unidrive - Modbus CMP Ethernet Driver for JMobile

Simatic S7 Ethernet driver for JMobile

CANopen HMI Communication Driver for JMobile

KNX TP/IP Communication Driver for JMobile

JMobile V2.6 SP1 Release Notes

NMEA 0183 driver for JMobile

JMobile V2.0 HF1 Release Notes

Connecting UniOP to Beckhoff ADS Ethernet

Connecting UniOP to Moeller Easy800

Connecting UniOP to CoDeSys Controllers via Ethernet

Getting started with JMobile Suite

Connecting UniOP to Fatek Controllers with Facon Protocol

Updating Systems Components in UniOP Series 400 Products

Configuring an Omron PLC with Omron FINS Ethernet Driver

UniOP Command Summary

Connecting UniOP as a Modbus Slave

Connecting UniOP to Unidrive SP with Modbus CMP Protocol

Connecting UniOP to Omron PLCs with the FINS Protocol

DomiOP ebis504. Tech-note. Highlights

JMobile V2.0 SP1 Release Notes

Getting started with UniOP and CoDeSys integrated controller

HP JETADVANTAGE SECURITY MANAGER. Adding and Tracking Devices

Configuring PNSPO InduSoft Web Studio to communicate by Tag Name to Omron CJ2 PLCs and NJ MACs

Access Omron PLCs through an existing Talk2M connection

G9SP Ethernet IP Communication to Omron s CJ2 PLC s Rev1.0 Micheal Paradiso

Connecting UniOP as Modbus/TCP Server

Application Note EXOR UniOP etop HMI and Jmobile Studio

JMobile V2.0 Exor_template_v1.01

GP-PRO/PBIII for Windows Device/PLC CONNECTION MANUAL ADDITIONAL MANUAL. Hioki E.E. Corporation Controller Smart Site

Connecting UniOP Using Generic Modbus RTU

JMobile Suite User Manual

1. By adding [MODBUS Server] with [Ethernet] interface, the [MODBUS TCP/IP. Gateway] feature can be enabled by selecting the [Enable] checkbox.

H3 MOBILE HANDHELDS WITH INTEGRATED JMOBILE HMI SOFTWARE

EasyBuilder Pro V Added [Scrolling control address] setting in Event Display object and Alarm

Connecting UniOP to Galil/Yaskawa controllers

HMI Application for Omron PLC

G9SP Ethernet IP Communication to Omron s NJ5 PLC s Rev1.0 Mike Wash

Device/PLC Connection Manuals

New in Secomea Release 7.0. Nice to know information about the release: - Secomea Release 7.0 build public Version: 0.

CONTROLLER INFORMATION SHEET

NE1A Ethernet IP Communications with Omron CJ2 PLC Micheal Paradiso

EasyBuilder Pro V Build

DomiOP ebis400 Series A new generation of Building HMI s. embedded building information system

Internal PLC (CODESYS) User Manual

Device/PLC Connection Manuals

EasyBuilder Pro V screen and editing the project with the Work Space window open.

CODESYS v. 2.3, Ethernet driver for AGI 3xx Use the CODESYS Ethernet driver in the AGI Creator Set up the CODESYS for use with the AGI Creator

Allen-Bradley Micro800 Series

User Guide. ewon500 The Configurable Gateway PURPOSE. You have just received your brand new ewon500!

Wonderware DAServer 1.0 for Omron FINS Ethernet User s Guide

Import SIMATIC variables

Device/PLC Connection Manuals

Ethernet Connectivity for UniOP

Wonderware DAServer for Omron FINS Ethernet User s Guide

Connecting the TOPServer to Wonderware InSQL

1. Introduction. Be sure to read the release notes in section 10 before operating the Unit.

Compact HMI devices with 9 function keys, numerical keypad and 20 characters display.

1. Added [Scroll bar] feature in [System Parameter Settings]» [Model] tab. This

EasyBuilder Pro V [LB-12053: Failed to send an [Event Log] (when ON)]: When . sending fails, this register will be set ON.

etop Series 500 Operating Instructions

B Programmable Terminal NB Series. Practice Guide. Sysmac Studio Variable Table Import NB3Q-TW01B NB5Q-TW01B NB7W-TW01B NB10W-TW01B

Grid Connect EtherNet/IP Adapter CP1W-EIP61. Application and Setup Guide

Compact HMI devices with 5 function keys, numerical keypad and 20 characters display.

Industrial Networking

CONTROLLER INFORMATION SHEET

Understanding TOP Server Scan Rate Settings as They Affect Wonderware InTouch Applications

Connecting UniOP to Datalogic Barcode Readers

SCADA. Features and Benefits for Small to Medium Sized Communities. Presented by: Rick Alvarez

WebAccess AB LOGIX PLC Ethernet Driver Guide. Advantech WebAccess. - AB LOGIX PLC Ethernet Driver Guide Version: 1.02

EasyBuilder Pro V Added Combo Button object to HMI models: ie, emt, and XE.

KAS Network Interface Overview. March 30, 2017

EZTouch Protocol Conversion Feature

Copyright Information. Copyright ThePlcCorner.com

Quick user guide to Sevio and B&R. Document ID: sv_b&r_en_v17_05

SYSMAC Gateway Runtime Installation Guide

Omron FINS Ethernet Driver PTC Inc. All Rights Reserved.

2.6 Configuring the Ethernet Communication Module as an EtherNet/IP Adapter

Machine Automation Controller NJ-series. EtherNet/IP TM. Connection Guide. OMRON Corporation. CJ2-series Controller P568-E1-01

OMRON Rockwell CompactLogix or ControlLogix

C O N T R O L L E R I N F O R M A T I O N S H E E T. Siemens S7-300 Series (Ethernet)

User Manual GALILEO Communication Beckhoff TCP/IP. Software

B-1122(7) Tutorial Guide

Honeywell HC900 Ethernet Driver Help Kepware Technologies

Cyberlogic Knowledge Base

Connecting Motion Control in the Factory Implementing Communication Protocols

GE Ethernet Driver PTC Inc. All Rights Reserved.

EasyBuilder Pro V This model is a gateway device; therefore, it is not possible to generate a

The UniDataExchanger is a tool that allows an easier handling of the file transfer to and from UniOP operator panels. Contents

(GCCS-2) Global Common Controls Software Design Online Course (Version 6.0)

Ping Driver PTC Inc. All Rights Reserved.

Transcription:

Omron FINS Ethernet Driver for JMobile This Technical Note contains the information needed to connect the HMI to Omron controllers over an Ethernet network using the FINS command set. Exor International S.p.A. Ptn0366

Ver. 1.1 Omron FINS Ethernet Driver for JMobile 2

Copyright 2014 Exor International S.p.A. Verona, Italy Subject to change without notice The information contained in this document is provided for informational purposes only. While efforts were made to verify the accuracy of the information contained in this documentation, it is provided as is without warranty of any kind. Third-party brands and names are the property of their respective owners. Omron FINS Ethernet Driver for JMobile 3

Contents Omron FINS Ethernet Driver... 5 Settings... 5 Controller Settings... 7 Tag Import... 9 Import Files in the Tag Editor... 9 Aliasing Tag Names in Network Configurations... 10 Communication Status... 11 Omron FINS Ethernet Driver for JMobile 4

Omron FINS Ethernet Driver The chapter describes settings for the driver to be applied in Studio and on the PLC programming software in case anything is required to ensure proper connection between HMI and target device(s). Document code ptn0366 Version 1.01 Settings Figure 1 Alias IP address Port Name to be used to identify nodes in network configurations. The name will be added as a prefix to each tag name imported for each network node The Ethernet IP address of the controller connected to the operator panel Defines the port number used in the communication with the PLC. The Omron FINS Ethernet Driver for JMobile 5

UDP Port number must match the value specified in the PLC configuration; the default value is 9600. Most applications will use the default value. Network Node Unit Panel Network Panel Node Panel Unit Parameters that define the FINS address of the device. There is a conversion rule to determine the IP address of a device starting from the FINS address in the Omron network. When using the FINS communication service, it is necessary to specify the node addressing according to the FINS addressing scheme. Even in this case, data must be sent and received on the Ethernet network using IP addresses. Therefore, IP addresses are converted from FINS addresses. There are three ways to convert the FINS addresses into the corresponding IP address; they are: Automatic generation (default) IP address table Combined method (uses Automatic and IP address table) The Omron documentation contains all the details related to determine the IP address of the controller depending on the FINS address assigned to it. The next chapter shows an example of controller configuration based on IP address table. The Panel Network/Node/Unit parameters assigned to HMI should be compatible with the ones assigned in the Omron network to the PLC: Network Number must match the one specified for the PLC Node Number should match the last number of the IP address of the HMI; in the figure above the panel has been configured with IP address 192.168.2.15. Unit represent the possible different network cards over the same node; for the HMI should be always set to zero since there is always only one communication unit. The protocol supports the connections to multiple controllers. To enable this, check the "PLC Network" check box and provide the configuration per each node. Omron FINS Ethernet Driver for JMobile 6

Figure 2 Controller Settings The controller must be properly configured to handle the communication with the panel. The next figure shows the screen of the Omron CX programming software from where you can define the network parameters. Omron FINS Ethernet Driver for JMobile 7

Figure 3 The figure below shows an example of configuration based on the IP address table conversion. The IP addresses used are matching the HMI project settings screens as shown above. Figure 4 Omron FINS Ethernet Driver for JMobile 8

Tag Import The Omron FINS Ethernet driver can import tag information from CX-Programmer PLC programming software. The tag import filter accepts symbol files with extension.cxr created by the Omron programming tool. The.cxr files can be exported from the symbol table utility. See in figure how to access the Symbol Table (if configured) from the Omron programming software. Figure 5 Import Files in the Tag Editor Select the driver in the Tag Editor and click on the Import tag button to start the importer. Omron FINS Ethernet Driver for JMobile 9

Figure 6 Locate the.cxr file and confirm. The tags present in the exported document are listed in the tag dictionary from where they can be directly added to the project using the add tags button as shown in the following figure Figure 7 Aliasing Tag Names in Network Configurations Tag names must be unique at project level; it often happens that the same tag names are to be used for different controller nodes (for example when the HMI is connected to two devices that are running the same application). Since tags include also the identification of the node and Tag Editor does not support duplicate tag names, the import facility in Tag Editor has an aliasing feature that can automatically add a prefix to imported tags. With this feature tag names can be done unique at project level. The feature works when importing tags for a specific protocol. Each tag name will be prefixed with the string specified by the Alias. As shown in the figure below, the connection to a certain controller is assigned the name Node1. When tags are imported for this node, all tag names will have the prefix Node1 making each of them unique at the network/project level. Omron FINS Ethernet Driver for JMobile 10

Figure 8 Note: Aliasing tag names is only available when tags can be imported. Tags which are added manually in the Tag Editor do not need to have the Alias prefix in the tag name. The Alias string is attached to the tag name only at the moment the tags are imported using Tag Editor. If you modify the Alias string after the tag import has been completed, there will be no effect on the names already present in the dictionary. When the Alias string is changed and tags are imported again, all tags will be imported again with the new prefix string. Communication Status The current communication status can be displayed using the dedicated system variables. Please refer to the User Manual for further information about available system variables and their use. The codes supported for this communication driver are: Error NAK Notes Returned in case the controller replies with a not acknowledge; can be returned also in case the network/node/unit parameters contained in the PLC response are not matching with panel configuration Omron FINS Ethernet Driver for JMobile 11

Timeout Invalid response Cnt error General Error Returned when a request is not replied within the specified timeout period; ensure the controller is connected and properly configured to get network access The panel did receive from the controller a response, but its format or its contents is not as expected; ensure the data programmed in the project are consistent with the controller resources. The same error can be returned also in case the PLC could not complete the processing of the panel request and sent back to the panel and invalid/not completed response. Returned when a specific control character in the protocol frame received does not match with the corresponding one in the request; verify the proper settings of the controller network configuration Error cannot be identified; should never be reported; contact technical support Omron FINS Ethernet Driver for JMobile 12