SURGELOGIC TM. Surge Protective Device Transient Voltage Surge Suppressor (TVSS) XGA, XT, XF, XP Series. Class Schneider Electric Brands

Similar documents
Surgelogic Surge Protective Device I-Line Plug-On Unit Series

Surgelogic Surge Protective Devices LC, XR, and XW Series

BSPD Surge Protective Devices

Eaton s SPD Series for integration into electrical distribution equipment

Internal Modular SPDs

Clipper Power System Visor Series

ZoneMaster Series Surge Protection Devices

15-80 ka surge protection Hz line frequency <.5 ns response time Available in units noted from 15-1,200 Amps

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

Protect your facility from the destructive effects of power surges with a fully

I-Line SPDs Square D TM Internally Mounted Surge Protective Devices

THE SURGE PROTECTION SOLUTION

Powerware TVSS (Transient Voltage Surge Suppression) ZoneMaster, ZoneSentinel, ZoneDefender

Section 6. Surge Protective Devices (SPDs) Table of Contents. Externally Mounted Surge Protective Devices

OVRH catalog Surge protective devices

Liebert TVSS: The First Line of Defense - Product Overview. Jim Tiesi

B. System Design and Performance Requirements

2.1. SPD, Power Conditioning, PF Capacitors and Harmonic Filters. Contents Description. Introduction. Surge Protection and Power Conditioning

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

SECTION SURGE PROTECTIVE DEVICES

Surgelogic. Surge Protective Devices (SPDs) Residential. Catalog 6671CT9701R08/

PHOENIX CONTACT Features

MDSP-Series 90kA, 150kA, 300kA Modular Distribution Surge Protector Type 2 Class II Surge Arrester

Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protective Devices. STV100K Series. Instruction Manual

1. This section describes the materials and installation requirements for surge protective devices (SPD) for the protection of all AC electrical

File E Project 08NK October 2, 2009 REPORT SURGE PROTECTIVE DEVICES (VZCA) GE Zenith Controls Bonham, TX

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

File E Project 08NK November 24,2009 REPORT TRANSIENT VOLTAGE SURGE SUPPRESSORS (VZCA/VZCA7)

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

Section 9 TVSS. Contents

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

GENERAL UL th EDITION DESIGN-BUILD SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

TransGuard. Electrical Transient Suppression Filter Systems. Installation, Operation and Maintenance Manual PN ,

Surge Protection Devices OVR series

R-LB R-LX Series Installation, Operation & Maintenance Manual

MasterMind. MasterMind. Diagnostic Monitoring System For Select and TransGuard Suppression Filter Systems

Always "On" UPS Systems Inc. USER MANUAL

NEMA 1 / IP40 metal housing. Compact design

Surge Protective Devices (SPD)

Surge Protection Devices (SPD)

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

GE TR7000 Series Wall Mounted Surge Protective Device (SPD)

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

ASCO SERIES 300 Manual Transfer Switch Solutions

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-3: SURGE PROTECTOR PERFORMANCE AND EVALUATION CRITERIA

GE Digital Energy. Power Quality

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty

PowerPak 2 Power Distribution Unit. Flexible. Configurable. Intelligent. Safe.

Specifications, Installation, and Operating Instructions

Installation and Operation Manual

Liebert LM Series Surge Protective Device Continuous Protection For Your Business. Surge Protection For Business-Critical Continuity

Eaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289

Eaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289

Instruction Bulletin Boletín de instrucciones Directives d'utilisation , Rev. 02, 03/2016

Installation Instructions & User Manual

Instruction Manual IM E Table of Contents

Liebert LM Series. Continuous Protection For Your Business. Surge Protection For Business-Critical Continuity

Protecting the electronic world from surges

Wireless Digital Compass

TDX Series. Transient Discriminating TM TVSS

DTK-WH8PLUS. Premium Whole House Surge Protection General Product Specifications

Surg Sur e P ot r ection

SURGE PROTECTION USER MANUAL. Surge Protection Device PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) B

SECTION TRANSIENT VOLTAGE SURGE SUPPRESSION

Tel: Web: Lightning and surge protection help pages

Installation and Operation Manual

Hubbell Surge Protective DeviceS

4-Pole Relay. 2 Coil. [V] Hz A1 A2 60 Hz A24 A1 A20 A2

TVSS Series STABILINE Transient Voltage Surge Suppressors

SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA

INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs)

A New, Standalone 24 Vdc Field Power Supply Reduces Costs, Simplifies Connectivity for Distributed I/O Devices on Industrial Machinery

ICS Entrance Management Sign Installation Guide. Version 1.0

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

Fail-safe performance Modular flexibility SURGEBANTM. Transient suppression systems

Plugstrip and Wallmount Surge Protectors

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

Surge Protective Devices. STV25K Series. Instruction Manual

Wireless Accelerometer - Impact Detect Sensor General Description Features of Monnit ALTA Sensors Principle of Operation Example Applications

Table of Contents. Safety. Attention. Warnings

Equipment level protection for AC/DC network cable, data and low voltage applications. Available in din-rail and direct inline installation.

Surge Protection Solutions. Industrial Market Automation Market OEM Market

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

DAW 8/28/09. TITLE Specification I2R 120/240 RR 120V AC Split Phase Surge Protector PAGE 1 of 9 REVISIONS

Jockey Pump Controllers

CPS block & CPS nano UL rd Ed. Surge protective devices (SPD)

Power Xpert Branch Circuit Monitor

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

The following standards are the basis of design, manufacture, and test of SPD equipment: Guide for Surge Voltages in Low-Voltage AC Power Circuits

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

Bulletin 871C Plastic Face/Plastic Barrel or Nickel-Plated Brass Barrel

5000 SERIES UNINTERRUPTIBLE POWER SYSTEMS

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

SECTION SWITCHBOARDS

Total Home Surge Protection for Point-of-Entry. FirstSurge TM. User Manual - Canada (English)

KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE

Transcription:

SURGELOGI TM Surge Protective Device Transient Voltage Surge Suppressor () XG, XT, XF, XP Series lass 1310 OTETS Description Page Product Descriptions.................................................. 2 pplication Information................................................ 6 Selection and Specifications............................................ 7 Wiring Diagrams..................................................... 9 Dimensions and Weights............................................. 13 Schneider Electric rands

XG Series Description The XG series is a modular parallel transient voltage surge suppressor () designed for service entrance or downstream applications. The XG device is a multi-stage suppression circuit consisting of field-proven, fast-acting 40 mm metal oxide varistors (MOVs). surge suppression path is provided for each mode, line-to-neutral (L ), line-to-line (L L), line-to-ground (L G), and neutral-to-ground ( G). Each surge suppression mode is individually fused and uses circuitry with thermal cutouts to provide normal operation during severe overvoltages and high fault current conditions. The suppression elements are encapsulated in UL Listed and patented eramgard, providing additional protection. filter network is added to provide wave shape smoothing and a high level of EMI/RFI noise attenuation. On-line diagnostics continuously monitor the unit status and have redundant LEDs to signal a reduction in surge capacity or loss of a suppression circuit. n audible alarm with test and silence features is included in the standard diagnostic package. Design Features Individually fused suppression modes Thermal cutout opper bus bar connection Solid state bi-directional Front panel alarm with test/silence switch LED indicators indicate loss of protection, or fully operational circuit High-energy parallel design for category,, and 3 applications External mounting next to panelboards, switchboards, switchgear, or motor control centers (Ms) tracking filter with EMI/RFI filtering up to -50 d from 100 khz to 100 MHz Performance Features Surge apacity L L G G 160 k / phase 80 k 80 k 120 k 240 k / phase 120 k 120 k 120 k XG Series Voltage Specifications UL Suppression Voltage Rating (SVR) atalog umber Service Voltage L L G G L L MOV TVS1XG... 120/240 V, 1-phase 330 330 330 700 150 TVS2XG... TVS3XG... TVS4XG... TVS8XG... 208Y/120 V, 3-phase, 4-wire 240/120 V, 3-phase, high-leg delta 480Y/277 V, 3-phase, 4-wire 600Y/347 V, 3-phase, 4-wire MOV = maximum continuous operating voltage 330 330 330 700 150 700/330 330 330 1200/700 275/150 600 600 600 1200 320 1000 1000 900 1800 420 2 1999 Square D ll Rights Reserved 11/99

XT Series Description The XT series is a non-modular parallel transient voltage surge suppressor () designed for service entrance or downstream applications. The XT device is a multi-stage suppression circuit consisting of field-proven, fast-acting 40 mm metal oxide varistors (MOVs). surge suppression path is provided for each mode, line-to neutral (L ), line-to-line (L L), line-to-ground (L G), and neutral-to-ground ( G). Each surge suppression mode is individually fused and uses circuitry with thermal cutouts to provide normal operation during severe overvoltages and high fault current conditions. The suppression elements are encapsulated in UL Listed and patented eramgard, providing additional protection. filter network is added to provide wave shape smoothing and a high level of EMI/RFI noise attenuation. On-line diagnostics continuously monitor the unit status and have redundant LEDs to signal a reduction in surge capacity or loss of a suppression circuit. n audible alarm with test and silence features is included in the standard diagnostic package. Design Features Individually fused suppression modes Thermal cutout Solid state bi-directional Front panel alarm with test/silence switch LED indicators indicate loss of protection, or fully operational circuit High-energy parallel design for category,, and 3 applications External mounting next to panelboards, switchboards, switchgear, or motor control centers (Ms) tracking filter with EMI/RFI filtering up to -50 d from 100 khz to 100 MHz Performance Features Surge apacity L L G G 120 k / phase 80 k 40 k 120 k 160 k / phase 80 k 80 k 120 k 240 k / phase 120 k 120 k 120 k XT Series Voltage Specifications UL Suppression Voltage Rating (SVR) atalog umber Service Voltage L L G G L L MOV TVS1XT... 120/240 V, 1-phase 330 330 330 700 150 TVS2XT... TVS3XT... TVS4XT... TVS8XT... 208Y/120 V, 3-phase, 4-wire 240/120 V, 3-phase, high-leg delta 480Y/277 V, 3-phase, 4-wire 600Y/347 V, 3-phase, 4-wire MOV = maximum continuous operating voltage 330 330 330 700 150 700/330 330 330 1000/700 275/150 600 600 600 1200 320 1000 1000 900 1800 420 11/99 1999 Square D ll Rights Reserved 3

XF Series Description The XF series is a non-modular parallel transient voltage surge suppressor () designed for service entrance or downstream applications. The XF device is a multi-stage suppression circuit consisting of field-proven, fast-acting metal oxide varistors (MOVs). surge suppression path is provided for each mode, line-to-neutral (L ), line-to-line (L L), line-to-ground (L G), and neutral-to-ground ( G). Each surge suppression mode is individually fused and uses circuitry with thermal cutouts to provide normal operation during severe overvoltages and high fault current conditions. The suppression elements are encapsulated in UL Listed and patented eramgard, providing additional protection. filter network is added to provide wave shape smoothing and a high level of EMI/RFI noise attenuation. On-line diagnostics continuously monitor the unit status and have LEDs to signal a reduction in surge capacity or loss of a suppression circuit. Optional diagnostic packages include an audible alarm and dry contacts. Design Features Individually fused suppression modes Thermal cutout Solid state bi-directional LED indicators indicate loss of protection, or fully operational circuit High-energy parallel design for category,, and 3 applications External mounting next to panelboards tracking filter with EMI/RFI filtering up to -50 d from 100 khz to 100 MHz Performance Features Surge apacity L L G G 80 k / phase 40 k 40 k 30 k XF Series Voltage Specifications UL Suppression Voltage Rating (SVR) atalog umber Service Voltage L L G G L L MOV TVS1XF80... 120/240 V, 1-phase 330 330 330 700 150 TVS2XF80... TVS3XF80... TVS4XF80... TVS8XF80... 208Y/120 V, 3-phase, 4-wire 240/120 V, 3-phase, high-leg delta 480Y/277 V, 3-phase, 4-wire 600Y/347 V, 3-phase, 4-wire MOV = maximum continuous operating voltage 330 330 330 700 150 700/330 330 330 1000/700 275/150 600 600 600 1200 320 1000 1000 900 1800 420 4 1999 Square D ll Rights Reserved 11/99

XP Series Description The XP series is a non-modular parallel transient voltage surge suppressor () designed for service entrance or downstream applications. The XF device is a multi-stage suppression circuit consisting of field-proven, fast-acting metal oxide varistors (MOVs). surge suppression path is provided for each mode, line-to-neutral (L ), line-to-line (L L), line-to-ground (L G), and neutral-to-ground ( G). Each surge suppression mode is individually fused and uses circuitry with thermal cutouts to provide normal operation during severe overvoltages and high fault current conditions. The suppression elements are encapsulated in UL Listed and patented eramgard, providing additional protection. filter network is added to provide wave shape smoothing and a high level of EMI/RFI noise attenuation. On-line diagnostics continuously monitor the unit status and have LEDs to signal a reduction in surge capacity or loss of a suppression circuit. Optional diagnostic packages include an audible alarm and dry contacts. Design Features Individually fused suppression modes Solid state bi-directional LED indicators indicate loss of protection, or fully operational circuit High-energy parallel design for category,, and 3 applications External mounting next to panelboards tracking filter with EMI/RFI filtering up to -50 d from 100 khz to 100 MHz Performance Features Surge apacity L L G G 50 k / phase 25 k 25 k 19.5 k XP Series Voltage Specifications UL Suppression Voltage Rating (SVR) atalog umber Service Voltage L L G G L L MOV TVS1XP50... 120/240 V, 1-phase 330 330 330 700 150 TVS2XP50... TVS3XP50... 208Y/120 V, 3-phase, 4-wire 240/120 V, 3-phase, high-leg delta MOV = maximum continuous operating voltage 330 330 330 600 150 700/330 330 330 1000/700 275/150 11/99 1999 Square D ll Rights Reserved 5

pplication Information The effects of lightning and the damage caused by lightning-generated transients are well known. The failure of sensitive electronic equipment in a facility located in a high lightning area can easily be attributed directly to lightning-generated transients. Transient protection can be installed on the power distribution system to protect this equipment from these externally generated transients. Lower magnitude transients generated within a facility and their effect on microprocessor-based equipment are less obvious than the transients induced by lightning. Transient voltages generated from inductive motors, pumps, electric welders, etc., may not be large enough to cause immediate damage, but they can cause sensitive equipment to malfunction. damaging transient voltage can enter a facility from several locations. The highest level of protection should be provided at the service entrance. second level of protection should be provided at distribution points serving critical areas, for example, computer rooms, accounting areas, and laboratories. Other facility entry points that should be protected include panels serving outdoor lights or outdoor equipment, such as motors. Protection should also be provided for critical areas with sensitive equipment essential to the company. products offered by Square D ompany provide protection at every level of the electrical distribution system. Typical applications include: anking Transportation Retail Education Wastewater/Sanitation Utility Government Medical Insurance Petrochemical Financial Data Processing Military Telecommunications Publishing utomated Manufacturing OTE: Refer to the product-specific catalog for information about internally mounted devices. 6 1999 Square D ll Rights Reserved 11/99

Selection and Specifications XG Series Service Voltage 120/240 V, 1-phase, 3-wire 208Y/120 V, 3-phase, 4-wire 240/120 V, 3-phase, 4-wire (high-leg delta) 480Y/277 V, 3-phase, 4-wire 600Y/347 V, 3-phase, 4-wire * = enclosure option, _ = any other options Peak Surge urrent Rating Per Phase atalog umber 160 k TVS1XG16*_ 240 k TVS1XG24*_ 160 k TVS2XG16*_ 240 k TVS2XG24*_ 160 k TVS3XG16*_ 240 k TVS3XG24*_ 160 k TVS4XG16*_ 240 k TVS4XG24*_ 160 k TVS8XG16*_ 240 k TVS8XG24*_ XT Series Service Voltage 120/240 V, 1-phase, 3-wire 208Y/120 V, 3-phase, 4-wire 240/120 V, 3-phase, 4-wire (high-leg delta) 480Y/277 V, 3-phase, 4-wire 600Y/347 V, 3-phase, 4-wire * = enclosure option, _ = any other options Peak Surge urrent Rating Per Phase atalog umber 120 k TVS1XT12*_ 160 k TVS1XT16*_ 240 k TVS1XT24*_ 120 k TVS2XT12*_ 160 k TVS2XT16*_ 240 k TVS2XT24*_ 120 k TVS3XT12*_ 160 k TVS3XT16*_ 240 k TVS3XT24*_ 120 k TVS4XT12*_ 160 k TVS4XT16*_ 240 k TVS4XT24*_ 120 k TVS8XT12*_ 160 k TVS8XT16*_ 240 k TVS8XT24*_ XF Series Service Voltage Peak Surge urrent Rating Per Phase atalog umber 120/240 V, 1-phase, 3-wire 80 k TVS1XF80*_ 208Y/120 V, 3-phase, 4-wire 80 k TVS2XF80*_ 240/120 V, 3-phase, 4-wire (high-leg delta) 80 k TVS3XF80*_ 480Y/277 V, 3-phase, 4-wire 80 k TVS4XF80*_ 600Y/347 V, 3-phase, 4-wire 80 k TVS8XF80*_ * = enclosure option, _ = any other options XP Series Service Voltage Peak Surge urrent Rating Per Phase atalog umber 120/240 V, 1-phase, 3-wire 50 k TVS1XP50*_ 208Y/120 V, 3-phase, 4-wire 50 k TVS2XP50*_ 240/120 V, 3-phase, 4-wire (high-leg delta) 50 k TVS3XP50*_ * = enclosure option, _ = any other options 11/99 1999 Square D ll Rights Reserved 7

Selection and Specifications Specifications Relative Humidity Operating Frequency Storage Temperature Operating Temperature Standards Fusing 0 to 95% non-condensing 47 63 Hz -20 to +65 (-4 to +149 F) 0 to +50 (+32 to +122 F) SI/IEEE 62.41 and 62.45 -UL, UL 1449 Second Edition UL ategory Section 37.3 (25 k test) Individually fused suppression modes Enclosure Options Enclosure Type Environment Provides Protection gainst vailable on Series atalog Option umber EM Type 1 Indoor ontact with the enclosed equipment. ll, F EM Type 12 Indoor irculating dust, falling dirt, dripping liquids. ll R EM Type 3R Outdoor Falling rain, sleet. Undamaged by ice. ll R EM Type 4 Indoor/Outdoor Windblown dust and rain, splashing water, hose-directed water. EM Type 4X EM Type 4X Stainless Indoor/Outdoor Indoor/Outdoor = surface mount; F = flush mount Windblown dust and rain, splashing water, hose-directed water. Resists corrosion. Windblown dust and rain, splashing water, hose-directed water. Resists corrosion. XG 4 XT, XF, XP R XG only XG only X S Other Options Option Description vailable on Series atalog Option umber Remote Monitor and Dry ontacts Displays the alarm status of the surge protective device up to 1,000 ft (305 m) away from the unit. This option comes with and uses the dry contacts option. ll M Internal ircuit Isolator Provides a mechanical means to electrically isolate the entire surge suppressor after opening the enclosure door to facilitate the servicing of the unit s components. XG I udible larm The audible alarm provides sound if an inoperative condition occurs. XG, XT XF, XP one (standard) Dry ontacts Provides an available 9-pin D-Sub style connector to monitor power O/OFF and alarm status. ll D Surge ounter Displays the combined total number of transient voltage surges detected from L G, L L, L, and G since the counter was last reset. XG, XT M Module Replacements System Voltage Peak Surge urrent Rating 120/240 V, 1-phase, 3-wire 208Y/120 V, 3-phase, 4-wire 120/240 V, 3-phase, 4-wire, high-leg delta 480Y/277 V, 3-phase, 4-wire 600Y/347 V, 3-phase, 4-wire atalog umber Phase Phase Phase 160 k M1XG16 empty M1XG16 240 k M1XG24 empty M1XG24 160 k M1XG16 M1XG16 M1XG16 240 k M1XG24 M1XG24 M1XG24 160 k M1XG16 M3XG16 M1XG16 240 k M1XG24 M3XG24 M1XG24 160 k M4XG16 M4XG16 M4XG16 240 k M4XG24 M4XG24 M4XG24 160 k M8XG16 M8XG16 M8XG16 240 k M8XG24 M8XG24 M8XG24 With all system voltages, devices must be grounded in accordance with all applicable standards. Phase modules are different than Phase and Phase modules. 8 1999 Square D ll Rights Reserved 11/99

Transient Voltage Surge Suppressor () XG Series Wiring Diagrams PHSE EU EUTRL PHSE PHSE "" PHSE EUTRL EUTRL PHSE "" ustomer onnections 1-Phase, 3-Wire, Grounded Installation PHSE PHSE EU EUTRL PHSE EUTRL PHSE PHSE "" PHSE "" EUTRL PHSE "" ustomer onnections 3-Phase, 4-Wire, Grounded Wye Installation PHSE (HIGH-LEG) EU PHSE PHSE EUTRL PHSE EUTRL ote: The high-leg of the power system must connect to phase of the. PHSE "" PHSE "" EUTRL PHSE "" ustomer onnections 3-Phase, 4-Wire, High-Leg Delta Installation 11/99 1999 Square D ll Rights Reserved 9

EU Transient Voltage Surge Suppressor () XG Series Wiring Diagrams PHSE EU EUTRL PHSE "" PHSE EUTRL EUTRL PHSE "" PHSE ustomer onnections 1-Phase, 3-Wire, Grounded Installation with ircuit Isolator PHSE PHSE EUTRL PHSE EUTRL PHSE "" PHSE "" EUTRL PHSE "" PHSE ustomer onnections 3-Phase, 4-Wire, Grounded Wye Installation with ircuit Isolator PHSE (HIGH-LEG) EU PHSE PHSE EUTRL PHSE "" PHSE PHSE "" EUTRL EUTRL PHSE "" ote: The high-leg of the power system must connect to phase of the. ustomer onnections 3-Phase, 4-Wire, High-Leg Delta Installation with ircuit Isolator 10 1999 Square D ll Rights Reserved 11/99

XT Series Wiring Diagrams Dry contact cable PHSE G EUTRL PHSE J1 J2 J3 1-Phase, 3-Wire, Grounded Installation Dry contact cable PHSE G PHSE EUTRL PHSE J1 J2 J3 3-Phase, 4-Wire, Grounded Wye Installation Dry contact cable High-leg PHSE (HIGH-LEG) G PHSE PHSE EUTRL ote: The high-leg of the power system must connect to phase of the. J1 J2 J3 3-Phase, 4-Wire, High-Leg Delta Installation 11/99 1999 Square D ll Rights Reserved 11

XF/XP Series Wiring Diagrams PHSE φ φ φ EUTRL PHSE 1-Phase, 3-Wire, Grounded Installation PHSE PHSE φ φ φ EUTRL PHSE 3-Phase, 4-Wire, Grounded Wye Installation PHSE (HIGH-LEG) φ φ φ PHSE High-Leg PHSE EUTRL ote: The high-leg of the power system must connect to phase of the. 3-Phase, 4-Wire, High-Leg Delta Installation 12 1999 Square D ll Rights Reserved 11/99

XG Series Dimensions and Weights EM Type 1 and EM Type 4 Enclosures EM Type 4X Stainless Steel Enclosure 12.36 (314) 10.00 (254) 12.75 (324) 13.55 (344) Front View Inside View 14.36 (365) 12.00 (305) EM Type 1 and EM Type 4 Enclosures with ircuit Isolator EM Type 4X Stainless Steel Enclosure with ircuit Isolator 16.75 (425) 17.77 (451) Front View Inside View Dimensions Weight Depth Inches (millimeters) 35 lb (16 kg) maximum The maximum depth of the outer face of the door to the mounting plane is 6.5 in. (165 mm). 11/99 1999 Square D ll Rights Reserved 13

XG Series Dimensions and Weights EM Type 1 Flush Mount Enclosure 14.00 (356) 12.00 (305) 10.98 (279) 13.99 (355) 9.00 (229) 12.00 (305) Front View Inside View EM Type 1 Flush Mount Enclosure with ircuit Isolator 14.00 (356) 11.88 (302) 11.00 (279) 20.00 (508) 15.00 (381) 18.00 (457) Front View Inside View Dimensions Weight Depth Inches (millimeters) 35 lb (16 kg) maximum The maximum depth of the outer face of the door to the mounting plane is 6.25 in. (159 mm). 14 1999 Square D ll Rights Reserved 11/99

XG Series Dimensions and Weights EM Type 12/3R Enclosure 12.50 (318) 3.00 (76) 13.00 (330) 14.00 (356) Front View Inside View EM Type 12/3R Enclosure with ircuit Isolator 16.50 (419) 13.00 (330) 22.00 (559) 21.00 (533) Front View Inside View Dimensions Weight Depth Inches (millimeters) 35 lb (16 kg) maximum The maximum depth of the outer face of the door to the mounting plane is 6.5 in. (165 mm). 11/99 1999 Square D ll Rights Reserved 15

XG Series Dimensions and Weights EM Type 4 Enclosure without ircuit Isolator EM Type 4X Enclosure with ircuit Isolator 14.52 (369) 12.26 (311) 17.76 (451) 16.52 (420) Front View, lear over Removed Dimensions Weight Depth Inches (millimeters) 35 lb (16 kg) maximum The maximum depth of the outer face of the door to the mounting plane is 8 in. (203 mm). 16 1999 Square D ll Rights Reserved 11/99

XT Series Dimensions and Weights EM Type 1, EM Type 12/3R, and EM Type 4 over onfiguration with Window and Tamper Proof Option 8.30 (211) 6.00 (152) 8.00 (203) 9.55 (243) 8.75 (222) 8.30 (211) 8.00 (203) over Removed Dimensions Weight Depth Inches (millimeters) 17 lb (8 kg) maximum The maximum depth of the outer face of the door to the mounting plane for the EM Type 1 enclosure is 6.0 in. (152 mm). For the EM Type 12/3R and EM Type 4 enclosures it is 5.5 in. (140 mm). EM Type 1 over onfiguration for Flush Mount 9.50 (241) 9.50 (241) Dimensions Weight Depth Inches (millimeters) 17 lb (8 kg) maximum The maximum depth of the outer face of the door to the mounting plane is 5.7 in. (145 mm). 11/99 1999 Square D ll Rights Reserved 17

XF/XP Series Dimensions and Weights EM Type 1, EM Type 12/3R, and EM Type 4 Enclosures 7.55 (192) 6.00 (152) 6.80 (173) 5.36 (136) 6.00 (152) φ φ φ Dimensions Weight Depth Inches (millimeters) 6 lb (3 kg) maximum The maximum depth of the outer face of the door to the mounting plane is 4.0 in. (100 mm). 18 1999 Square D ll Rights Reserved 11/99

11/99 1999 Square D ll Rights Reserved 19

Square D ompany 8001 Highway 64 East Knightdale, 27545 1-888-Square D (1-888-778-2733) www.squared.com Schneider anada Inc. 19 Waterman venue, M4 1 Y2 Toronto, Ontario (416) 752-8020 www.schneider.ca Square D and are registered trademarks and SURGELOGI is a trademark of Square D ompany or related companies. ll other trademarks are the intellectual property of their respective companies. atalog o. 1310T9901 ovember 1999