Fluke Ti40FT and Ti45FT IR FlexCam Thermal Imagers with IR-Fusion Technology

Similar documents
Ti Series Thermal Imagers

Fluke Thermal Imaging Find it, fix it, fast. IR-Fusion Technology Not all fusion is created equal

Fluke Ti Series Thermal Imagers. Predict impending failures faster by seeing more

Fluke TiR Thermal Imager

Fluke TiR Series Thermal Imagers

Ti480 PRO and Ti450 PRO Infrared Cameras The Fluke Professional Series

Fluke Ti30 Thermal Imager. Provided by Everything needed for everyday imaging. Complete imaging solution. Lowest cost of ownership

PRODUCT ANNOUNCEMENT May 3, 2011

Ti480 PRO, Ti450 PRO, Ti400 PRO and Ti300 PRO Infrared Cameras The Fluke Professional Series

Ti480 PRO, Ti450 PRO, Ti400 PRO and Ti300 PRO Infrared Cameras The Fluke Professional Series

testo 875 and testo 881 for professional building thermography

Ti401 PRO, Ti480 PRO, TiX501 and TiX580 Infrared Cameras

Technical Data FLIR E40 (incl. Wi-Fi)

FLIR T Imaging and optical data. Minimum focus distance. Minimum focus distance with MSX. Spatial resolution (IFOV)

Thermal Imaging Camera TI120

Ti480, Ti450, Ti400 and Ti300 Infrared Cameras The Fluke Professional Series

Ti480, Ti450, Ti400 and Ti300 Infrared Cameras The Fluke Professional Series

Ti480 PRO and Ti450 PRO Infrared Cameras The Fluke Professional Series

Ti480, Ti450, Ti400 and Ti300 Infrared Cameras The Fluke Professional Series

Technical Data. FLIR T640bx 45 (incl. Wi-Fi)

Datasheet Thermal imager

Technical Data FLIR E60 (incl. Wi-Fi)

Thermal cameras. Detect hot spots before they cause you trouble

TiX580, TiX560, TiX520 and TiX500 Infrared Cameras The Fluke Expert Series

Committing to the future. See more with our thermal imagers testo 875 and testo 881 NEW. For industrial thermography applications

Fluke-Direct.com. TiX580, TiX560, TiX520 and TiX500 Infrared Cameras The Fluke Expert Series. Fluke Connect. compatible TECHNICAL DATA

350 Series AC/DC Clamp Meters

TiR Thermal Imager. Users Manual

ANNEXURE III PRINCIPAL TECHNICAL PARAMETERS OF INFRARED THERMOVISION CAMERA

It s time to SEE WHAT YOU RE MISSING THE EXPERT SERIES

Datasheet Thermal imager

TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Thermal Imagers

Model R2050. Thermal Imager, 80 x 80 Pixels. Instruction Manual.

The Thermal Imager for the Highest Demands

Technical Data. FLIR T (incl. Wi-Fi) Imaging and optical data

Thermal imagers for industrial thermography

INTELLIGENT SERIES THERMAL IMAGING CAMERA

Precise temperature distribution measurement and visualization with our IR-TCM HD Infrared Cameras. SHARING EXCELLENCE

D Series Intelligent Thermographic IR Camera. Copyright. Specifications. Document identity. Website. Customer support. Disclaimer

See more with the NEW testo 880 thermal imager

Infrared Thermography Camera InfReC Model R500 Series Debut

INTRODUCTION. ThermaCAM P640

INFRARED CAMERAS THT

IR-Thermal image analysis Fault detection made easy!

Technical Data FLIR E5

Datasheet. Revision number: 2.1

Infrared camera and visual IR thermometer selection guide

FLIR T Imaging and optical data. UltraMax (super-resolution) 1 NETD. Minimum focus distance. Minimum focus distance with MSX

Test Equipment Solutions Datasheet

FLIR E Imaging and optical data NETD. <30 mk, +30 C (+86 F) <40 mk, +30 C (+86 F) <50 mk, +30 C (+86 F) Field of view

Fluke Ti30 Thermal Imager

Dräger UCF 9000 NFPA Certified Thermal Imaging Camera

FLIR E Imaging and optical data. f number 1.3 Image frequency. Field of view match. Image presentation. Surface brightness (cd/m 2 ) 400

FLIR E Imaging and optical data NETD. <50 mk, +30 C (+86 F) Field of view. Minimum focus distance m (0.49 ft.

REASONS. to choose a Fluke Infrared Camera

GD_MD_GJ C C SERIES. High Performance Thermographic IR Camera

Dräger UCF 6000 Thermal Imaging Camera

Technical Data FLIR i7

FLIR E Imaging and optical data NETD. <50 mk, +30 C (+86 F) Field of view. Minimum focus distance m (0.49 ft.

VT04 and VT02 Visual IR Thermometers

Reasons. to choose a Fluke Infrared Camera

I N F R A R E D C A M E R A S 70 60

Dräger UCF 8000 NFPA Certified Thermal Imaging Camera

Hand-Held More Convenient I Longer Time Online More Professional Analysis I Faster Sharing

Infrared Cameras. The most portable infrared online camera. Innovative Infrared Technology

Capture what you couldn t see testo thermal PRO

THE GLOBAL LEADER IN INFRARED CAMERAS BEYOND COMPARE. FLIR B-Series. Smart, compact and powerful

Infrared Cameras. The most portable infrared online camera. NEW: High resolution of 382 x 288 pixels

Ti32, TiR32 Thermal Imagers

Technical Data FLIR i7

FLIR T400-Series 3,5. Excellent ergonomics and extensive communication possibilities ABC WIFI

Thermal Imaging. Made Easy.

T1K HD THERMAL IMAGING CAMERA THE ULTIMATE IN INFRARED PERFORMANCE

Ti10, Ti25, TiR and TiR1

REASONS. to choose a Fluke Thermal Imager

Infrared thermometers with visible laser for measuring surface temperature without contact

T-SERIES UNLEASH THE ULTIMATE POWER OF FLIR. thermal IMAGING CAMERAS FoR PREDICtIVE MAINtENANCE

Thermal Imaging Thermometer Omegascope

See more with the thermal imager testo 880

FC Series Traffic Camera. Architect & Engineering Specifications

The ultimate in thermographic evolution

VT04 and VT02 Visual IR Thermometers

FLIR GF-Series. Ergonomically designed and full featured GPS

More Precision. thermoimager TIM // Compact thermal imaging cameras

VarioCAM high resolution

T-SERIES THERMAL IMAGING CAMERAS FOR PREDICTIVE MAINTENANCE UNLEASH THE ULTIMATE POWER OF FLIR

Industrial thermography

THERMAL IMAGING CAMERAS

UMTI [UMTI USER MANUAL] User s Manual. Handheld Surveillance Thermal Camera

E-Series bx. FLIR E-Series bx Thermal Imaging Cameras. Revolutionary Performance. Superior Point & Shoot Thermal Imagery

TiR2, TiR3, TiR4. Getting Started Guide. IR FlexCam Thermal Imager

ЗАО «БЕРГ АБ», (495) , Thermal cameras. Detect hot spots before they cause trouble

Thermal Imaging Camera 220 x Instruction Manual

E-Series bx. FLIR E-Series bx Thermal Imaging Cameras. Revolutionary Performance. Superior Point & Shoot Thermal Imagery

T-SERIES THERMAL IMAGING CAMERAS FOR PREDICTIVE MAINTENANCE UNLEASH THE ULTIMATE POWER OF FLIR

FLIR T (incl. Wi-Fi)

FLIR T (incl. Wi-Fi)

T-SERIES UNLEASH THE ULTIMATE POWER OF FLIR THERMAL IMAGING CAMERAS FOR PREDICTIVE MAINTENANCE

USER MANUAL TOUGHPIX DIGITHERM. RUGGED AUTHORITY

FLIR T (incl. Wi-Fi)

Transcription:

Thermal Imaging Fluke Ti40FT and Ti45FT IR FlexCam Thermal Imagers with IR-Fusion Technology The versatile choice for maintenance and production engineers and technicians The Fluke Ti4x models feature everything needed for virtually every thermography task. With a 160 x 120 detector and a temperature sensitivity down to 0.08 C (80mK) (NETD) they deliver high resolution images where even the smallest temperature differences can be seen. The units are extremely easy to use through the Windows CE menu structure and offer an extended troubleshooting feature set to allow on the spot analysis in the field. The FT models feature the innovative IR- Fusion technology. IR-Fusion captures a visible light image in addition to the infrared image and takes the mystery out of IR image analysis. It helps to better identify and report suspect components and enable the repair to be done right the first time. To find out more select IR-Fusion on the side navigation of this page. Typical applications: Predictive maintenance Identify electrical and mechanical problems before they cause failure Industrial maintenance Check whether repairs have been performed successfully Quality control Examine prototypes and refine thermal management designs Process monitoring Real-time observation to ensure efficient and safe operation

Thermal Imaging Fluke Ti40FT and Ti45FT IR FlexCam Thermal Imagers with IR-Fusion Technology See exactly what you are viewing Fluke IR-Fusion technology links a real world visual image with a thermal image. It merges the two images into one, with the possibility to blend between the two images or create picture-in-picture combinations. Alarm limits can be superimposed over the visible light image to exactly pinpoint the components exceeding a specified temperature limit. Both the visual images and thermal images are available for use in reports. This speeds up documentation by reducing the need to look for individual images taken with a separate digital camera. IR Fusion helps to better identify and report suspect components and enable the repair to be done right the first time. Large, sharp thermal images Thanks to the largest display (five-inch) available on this type of thermal imager in combination with low-noise VOx sensors, the Fluke IR FlexCam units produce exceptionally high-quality images making even the smallest temperature differences visible. This is comparable with images normally only obtained on far more expensive instruments. A sharp image in every situation The innovative 180 articulating lens makes it possible to view and capture images in areas with poor accessibility. The display remains clearly visible while viewing over high objects, under a machine or around immoveable obstructions. The SmartFocus wheel simplifies getting a stable and sharp image. No need to take your hand off the instrument to turn a focus ring. Make anomalies visible Thanks to built-in functions like AutoCapture, the IR FlexCam Thermal Imagers help to troubleshoot difficult problems. The instrument is easily set up to automatically capture only those images where a temperature limit is exceeded. This way, difficult to find intermittent problems can be captured and analyzed quicker by concentrating only on the images containing the anomalies. Analysis and reporting comes standard The SmartView software (supplied with the unit) includes a complete range of infrared image viewing, analysis, annotation and reporting tools. It even allows for customized reports to accommodate specific company work processes or requirements like multiple image reporting and comparisons. To find out more select SmartView on the side navigation of this page. Radiometric measurement the data behind the picture Fully radiometric thermal imagers capture and store calibrated temperature data for the matrix of thousands of points that make up a thermal image. This makes it possible to perform detailed analysis and change key parameters like emissivity or temperature range either in the field on the camera or in the office using the PC software. Ti45FT Ti40FT High resolution, low noise VOx detector for high quality images 160 x 120 Temperature range to cover broad industrial applications -20 to + 600 C (-4 to 1112 F) High temperature option High thermal sensitivity for viewing even the smallest temperature differences 1200 ºC (2192 ºF) 0.08 ºC (80 mk) 0.09 ºC (90 MK) 180º articulating flexible lens to view images in every situation Choice of 3 interchangeable lenses to cover every application Large 5" high contrast color LCD for a clear picture independent of lighting conditions

Fully radiometric for detailed temperature analysis and tracking SmartFocus for best image quality and accurate temperature measurements Windows CE based menu structure for ease of use Personalized instrument set-up for multiple use CompactFlash memory cards to store over 1000 IR images plus fully radiometric temperature data SmartView reporting and analysis software included AutoCapture for making intermittent problems visible On-board analysis functions User defined text annotations for simplified reporting Built-in visible light (digital) camera IR/Visible Alarm function Laser pointer for easy targeting Flash and torch light for high quality images in dark environments

Fluke Ti5xFT and Ti4xFT FlexCam Thermal Imagers Technical Data The experts choice for problem solving and preventive/predictive maintenance Features Ti55FT High resolution, low noise VOx detector for high quality images Temperature range to cover broad industrial applications Ti50FT Ti45FT 320 x 240 +600 C (-4 F to 1112 F) High temperature option Ti40FT 160 x 120 +350 C (-4 F to 662 F) +600 C (-4 F to 1112 F) +350 C (-4 F to 662 F) 1200 C (2192 F) 0.05 C at 30 C (50 mk) 0.07 C at 30 C (70 mk) 0.08 C at 30 C (80 mk) 0.09 C at 30 C (90 mk) 180 articulating flexible lens to view images in every situation Choice of 3 interchangeable lenses to cover every application* Large 5 inch high contrast color LCD for a clear picture independent of lighting conditions Fully radiometric for detailed temperature analysis and tracking SmartFocus for best image quality and accurate temperature measurements Windows CE based menu structure for ease of use Personalized instrument set-up for multiple person use CompactFlash memory cards to store over 1000 IR images plus fully radiometric temperature data SmartView reporting and analysis software included AutoCapture for making intermittent problems visible High thermal sensitivity for viewing even the smallest temperature differences On-board analysis functions User defined text annotations for simplified reporting Built-in visible (visual) light camera IR-Fusion blending thermal and visible light images IR/Visible Alarm function Laser pointer for easy targeting Flash and torch light for high quality images in dark environments *10 mm and 54 mm lenses are optional and are only available at time of initial order. The Fluke Ti5xFT and Ti4xFT models feature everything needed for virtually any thermography task. All Fluke FlexCam Thermal Imagers come standard with the patent-pending Fluke IR-Fusion Technology fusing visual (visible light) images with infrared images. SmartView IR analysis and reporting software is included with each purchase along with free software upgrades for the life of your product. The Ti4xFT models feature 160 x 120 detectors and temperature sensitivity (NETD) down to 0.08 C (80 mk) in the higher end model. The Ti5xFT models feature 320 x 240 detectors and temperature sensitivity (NETD) down to 0.05 C (50 mk) in the higher end model. Choose Fluke FlexCam Thermal Imagers when you need industry leading thermal sensitivity for high resolution, ultra high-quality images. Typical applications: Troubleshooting Pinpointing the location of specific problems in equipment and systems. Preventive/predictive maintenance Identify electrical and mechanical problems before they cause failure. Industrial maintenance Check whether repairs have been performed correctly. Process monitoring Real-time observation to ensure efficient and safe operations. Quality control Examine prototypes and refine thermal management designs. Research and development Quantify heat patterns to improve product designs (Ti5XFT models). Electronic design Circuit board analysis (Ti5XFT models).

Detailed Detailed specifications Specifications Fluke Ti55FT Fluke Ti50FT Fluke Ti45FT Fluke Ti40FT Imaging performance Field of view (FOV)* 23 horizontal x 17 vertical Spatial resolution (IFOV)* 1.30 mrad 2.60 mrad Min focus distance* 0.15 m (5.9 in) Thermal sensitivity (NETD) 0.05 C at 30 C (50 mk) 0.07 C at 30 C (70 mk) 0.08 C at 30 C (80mK) 0.09 C at 30 C (90mK) Detector data acquisition/ image frequency 60 Hz/60 Hz 30 Hz/30 Hz Focus SmartFocus; one finger continuous focus (manual) IR digital zoom 2x, 4x, 8x 2x 2x Detector type 320 x 240 Focal Plane Array, Vanadium Oxide (VOx) Uncooled Microbolometer 160 x 120 Focal Plane Array, Vanadium Oxide (VOx) Uncooled Microbolometer Spectral band 8 µm to 14 µm Digital image enhancement Automatic full time enhanced On camera operating modes Full thermal, full visual light or merged thermal-visual images. Picture-in-Picture Full thermal, full visual light or merged thermal-visual images. Picture-in-Picture Visible light camera 1280 x 1024 pixels, full color Visible light digital zoom 2x, 4x 2x 2x Temperature measurement Calibrated temperature range 600 C (-4 F to 1112 F) in three ranges Range one = Range two = Range three = 250 C to 600 C (482 F to 1112 F) 350 C (-4 F to 662 F) in two ranges Range one = Range two = 600 C (-4 F to 1112 F) in three ranges Range one = Range two = Range three = 250 C to 600 C (482 F to 1112 F) 350 C (-4 F to 662 F) in two ranges Range one = Range two = Optional High temperature Up to 1200 C (2192 F) Range 4 = 500 C to 1200 C (932 F to 2192 F) Accuracy ± 2 C or 2 % (whichever is greater) Measurement modes Centerpoint, center box (area min/max, average), moveable spots/boxes, user defined field/text annotations, automatic hot and cold point detection, visible color alarm above and below Centerpoint, center box (area min/max, average) Centerpoint, center box (area min/max, average), moveable spots/boxes, user defined field/text annotations, automatic hot and cold point detection, visible color alarm above and below Centerpoint, center box (area min/max, average) Emissivity correction 0.1 to 1.0 (0.01 increments) Image presentation Digital display 13 cm (5 in) diagonal large high-resolution digital display LCD backlight Sunlight readable color LCD Video output RS170 EIA/NTSC or CCIR/PAL composite video Palettes Grayscale, grayscale inverted, blue red, high contrast, hot metal, ironbow, amber, amber inverted Optical lenses 54 mm telephoto lens High precision Germanium lens Field of view (FOV): 9 horizontal x 6 vertical Spatial resolution (IFOV): 0.47 mrad Spatial resolution (IFOV): 0.94 mrad Min focus distance: 0.6 m (1.97 ft) 2 Fluke Corporation Ti5XFT and Ti4XFT Thermal Imagers with IR-Fusion

General specifications Fluke Ti55FT Fluke Ti50FT Fluke Ti45FT Fluke Ti40FT Optical lenses (continued) 10.5 mm wide angle lens High precision Germanium lens Field of view (FOV): 42 horizontal x 32 vertical Spatial resolution (IFOV): 2.45 mrad Spatial resolution (IFOV): 4.9 mrad Min focus distance: 0.3 m (0.98 ft) Image and data storage Storage medium Compact flash card stores over 1000 IR images (512 MB card standard) File formats supported 14 bit measurement data included. Exportable Images: bmp, gif, jpg, png, tiff; Data formats: comma separated (csv), tab separated (txt). Interface and software Interface Compact flash card reader included Software SmartView; Full analysis and reporting software included Laser Classification Class II Laser targeting Laser dot visible on screen when blending thermal and visible image Controls and adjustments Set-up controls Date/time, temperature units C/F, language, scale, LCD intensity (high/normal/low) Image controls Level, span, auto adjust (continuous/manual) On-screen indicators Battery status, target emissivity, background temperature and realtime clock Power Battery type Li-Ion smart battery, rechargeable, field-replaceable (two included) Battery operating time Two hours continuous operation (per battery) Battery charging Two bay intelligent charger powered via ac outlet Continuous ac operation AC adapter 110/220 V ac, 50/60 Hz AC adapter 110/220 V ac, 50/60 Hz Power saving Automatic shutdown and sleep modes (user specified) Environmental and mechanical design Operating temperature -10 C to +50 C (14 F to 122 F) Storage temperature -40 C to +70 C (-40 F to 158 F) Relative humidity Operating and storage 10 % to 95 %, non-condensing Water and dust resistant IP54 Weight (including batteries) 1.95 kg (4.3 lb) Camera size (H x W x D) 162 mm x 262 mm x 101 mm (6.5 in x 10.5 in x 4.0 in) Other Warranty Two-years *Standard 20 mm Germanium lens Ordering information Fluke. Keeping your world up and running. FLK-Ti40FT-20 FLK-Ti45FT-20 FLK-Ti50FT-20 FLK-Ti55FT-20 Included with product Heavy duty carrying case, 2 rechargeable battery packs, battery charger, ac adapter (for Ti45FT and Ti55FT only), video cable, 512 MB compact flash card, compact flash card reader and USB cable, PCMCIA compact flash card reader, neck strap, printed getting started guide, SmartView reporting and analysis, software on CD, complete user manual on CD 3 Fluke Corporation Ti5XFT and Ti4XFT Thermal Imagers with IR-Fusion