Perle 10G Media Converter Modules

Similar documents
Perle 10G Media Converter Modules

Perle 10GT Media Converter Modules

Perle Cx-10GR-STS Media Converter Modules

Perle Protocol Transparent Media Converter Modules

Perle 10GT Media Converters

Perle Gigabit Media Converter Module. Installation Guide P/N

Perle S-10GRT-SFP Media Converter Installation Guide

Perle MCR200 Installation Guide

Perle 10/100 Ethernet Media Converter Module. Installation Guide. P/N (Rev C)

Perle Gigabit Media Converters

Perle SMI Media Converter Installation Guide

Perle PoE/PoE+ 10/100/1000 Ethernet Media Converters

Perle PoE/PoE+ 10/100 Ethernet Media Converters

Perle 10/100/1000 Ethernet Extender Modules. 10/100 10/100/1000 (Gigabit)

Perle SMI Media Converter Installation Guide

Perle SMI Media Converter Installation Guide

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

Perle Advanced Powered Ethernet Extenders Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Product names mentioned in this manual may be trademarks or registered trademarks of those products and are hereby acknowledged.

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Signamax Connectivity Systems Dual Rate SFP Converter Series U S E R S

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

USER S MANUAL. 10/100/1000Base-T 1000Base-SX/LX Gigabit Ethernet Converter GEP-5300TF-C GEP-5400TF-C

IFS MC201-1P/1FS User Manual

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

Copyright PLANET Technology Corp Contents subject to revision without prior notice.

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

100Base-FX to 10/100Base-TX. PoE. Media Converter. FCU-1802Px. User s Manual

MF BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

Gigabit Ethernet Media Converter

LNX-0702G-SFP Series

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

FCC Statement. Trademarks. Preface. Gigabit Ethernet Media Converter

CONVERTEON Family. One-Slot Chassis AT-CV1000. Installation Guide Rev. A

Converts any fiber optics type interface to any other fiber optics type interface.

These tiny media converters are perfect for bringing fiber to the desktop.

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

Bridge Module. Installation Guide and Users Reference Manual

IFS MCR-R15 Media Converter Rack User Manual

H3C SecPath M9000-S NSQM2MPUD0 main processing unit

LNX-1002C-SFP Series

Rugged Industrial Media Converter

Signamax Connectivity Systems Gigabit Ethernet SFP Media Converter

Preface. Media Converter

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

HDMI Optical Extender USER MANUAL VE882 / VE892

Add 10/100 copper ports to a High Density Media Converter Chassis.

Contents INTRODUCTION...1 CARD SETUP...2 INSTALLATION TECHNICAL DESCRIPTION SPECIFICATIONS... 14

Gigabit Fiber to Gigabit Fiber (100/1000) Media Converter. User Guide MS400230

TE100-DX16R/DX24R/DX32R 16/24/32 Ports Ethernet/Fast Ethernet Dual-Speed Stackable Hubs User s Guide

OPERATOR MANUAL OSD2153 SERIES GIGABIT ETHERNET MEDIA CONVERTER

The Gigabit Ethernet Media Converter fully complies with IEEE802.3ab 1000Base- T and IEEE802.3z 1000Base-SX/LX Gigabit Ethernet standards.

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

4170 POS System Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

16-SLOT IN-BAND MANAGEMENT CHASSIS

PCI Express Gigabit Ethernet Adapter. User's Guide

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

Connects 1000BASE-T twisted-pair to 1000BASE-SX/LX fiber.

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

Preface. Manual Revisions. Trademarks

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

Raven Series Standalone Media Converters

HES-3106-PLUS SERIES

AT-GS950/16 AT-GS950/24

Quick Start Guide. Cisco Compatible 10Gbase-LR SFP+ Transceiver with DDM, SMF, 1310 nm, 10 km, LC. Model: N286-10GLR-SLC PROTECT YOUR INVESTMENT!

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

16-Port Chassis Media Converter System Manual

Gigabit Miniature Media Converters. Connect Gigabit Ethernet copper ports to fiber optic cable.

Gigabit Ethernet Media Converter

Quick Start Guide. Physical Description. Gigabit Ethernet Media Converter. User s Manual 1. Product Overview. DIP Switch

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

Table of Contents... 1 Packing List... 2 FCC Statement... 2 Introduction Product Features... 3 Front Panel... 3 LEDs Installation...

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

OPERATOR MANUAL. OSD2053P SERIES MICRO 10/100Base-T to 100Base-X MEDIA CONVERTER. WITH PoE SOURCE

10/100/1000Base-T to 1000Base-FX Switch Converter User Guide

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

VE8012A/VE8012AR DUAL NETWORKED STATION PORT

Owner s Manual. Media Converters Models: N SC & N ST

32/64-bit PCI Bus 1000BASE-SX Gigabit Fiber Ethernet Adapter. User s Guide

IMC-21GA Quick Installation Guide

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

PCI-E Dual / Single Port 10 Gigabit Ethernet Adapter

EDG Port Industrial 10/100 Mbps Ethernet Switch. User Manual

6 / 8 Port Gigabit Ethernet Switch with PoE+ optional with 2x SFP Slots

FWRIII-2105 SERIES. 4 ports 10/100Mbps RJ-45; built-in IEEE802.11n WiFi and 1 port 100Mbps SFP slot uplink Residential Gateway. Residential Gateway

M727xSP. PoE Powered. Ethernet Media Converter 10/100BASE-TX TO 100BASE-SX/LX. Installation Guide

Industrial SFP/SFP Multi-Power Mode Converter

Transcription:

Perle 10G Media Converter Modules Installation Guide CM-10G-STS C-10G-STS CM-10G-XTS C-10G-XTS CM-10G-XTX C-10G-XTX CM-10G-XTSH C-10G-XTSH CM-10G-XTXH C-10G-XTXH P/N 5500326-10 (Rev C)

Overview This document contains instructions necessary for the installation and operation of the Perle 10G Media Converter modules that are used in conjunction with a Perle Media Converter chassis. Each module contains two pluggable transceiver ports that permit connections of SFP+ fiber, XFP fiber and copper modules. The C model modules are the unmanaged modules and the CM models are the managed modules. For information on the management options of the CM modules refer to the Perle MCR-MGT User s Guide that came with your Perle Management Module. The C/CM- 10G modules support low power transceivers, whereas the C/CM- 10G-XTSH and C/CM-10G-XTXH support high power (power level 4) transceivers. The high power modules take two slots within a Perle Media Converter chassis. All combination of modules within the chassis cannot exceed the chassis power input consumption. The full power consumption for Perle Media Converter chassis can be found on the Perle website. Models Port 1 Port 2 CM-10G-STS SFP+ SFP+ C-10G-STS SFP+ SFP+ CM-10G-XTS XFP SFP+ C-10G-XTS XFP SFP+ CM-10G-XTX XFP XFP C-10G-XTX XFP XFP High Power Models Port 1 Port 2 CM-10G-XTSH XFP SFP+ C-10G-XTSH XFP SFP+ CM-10G-XTXH XFP XFP C-10G-XTXH XFP XFP Note: The C/CM-10G media converter modules can be populated with two 1G fiber/copper modules to operate at 1G. However with 1G modules the C/CM-10G does not support the Loopback Auto Detect feature. Perle 10G Media Converter module Installation Guide 2

Getting to know your C/CM-10G Media Converter Module Your C/CM-10G Media Converter module package includes: A C/CM-10G Media Converter module with two pluggable transceiver ports This guide C/CM-10G Front View Perle 10G Media Converter module Installation Guide 3

Installation The default switch settings (all switches in the UP position) will work for most installations. The default Auto-Jumper is set to Auto. These are the steps required to configure the Perle 10G Media Converter module: 1. Set the Auto-Jumper switch. (optional) 2. Set the DIP switch settings. (optional) 3. Install the module into the chassis. (See Installing Modules) 4. Insert appropriate modules into the pluggable transceiver ports. 5. Connect fiber or copper cables to the installed modules. 6. The Media Converter module is automatically powered up. C/CM-10G-STS C/CM-10G-XTS, C/CM-10G-XTSH Perle 10G Media Converter module Installation Guide 4

C/CM-10G-XTX, C/CM-10G-XTXH Installing Modules 1. Set any jumpers and/or DIP switches on the module to the desired operating mode. 2. Gently slide the module into the slot until it becomes flush with the front of the chassis. Light pressure may be needed to seat the module. Do not force the module as you might damage the module. If there is resistance, remove the module and check the module s backplane connector for damage to the pins. If the module s backplane connector is not damaged, try to reinsert the module again 3. Tighten the Captive retainer screw to ensure the module is locked in place. Caution: Observe electrostatic discharge precautions when installing or removing the module(s) from the Chassis. Failure to observe this caution could result in damage to the module(s) and/or chassis. Perle 10G Media Converter module Installation Guide 5

Auto-Config Jumper (CM models only) The Auto-Config jumper (J5) is located on the upper edge, at the midpoint of the module. Strapping pins 1 and 2 of the jumper will set the module in SW mode and strapping pins 2 and 3 will set it in Auto-Config mode. Auto: When set to Auto the module will, at power-up, check its internal flash memory to see if configuration information has been downloaded to it from a management module. If so it will use this configuration as its running configuration. If there is no configuration in flash it will read the settings of the DIP switches and use those as its running configuration. SW: When set to SW (Switch), the module will, at power-up, read the settings of the DIP Switches and use those as its running configuration. It will ignore any configuration information in its flash memory. NOTE: The default jumper setting is Auto Perle 10G Media Converter module Installation Guide 6

DIP Switch Settings The DIP switches are located on the side of the module. The function of the DIP switches vary by model, so please refer to the appropriate model. Note: Switch changes made when the product is powered up take effect immediately and will result in a link reset on both ports. Operating Mode (Switch 1) Switch Position Up (default) Down Mode Data Test Data: In Data mode, data will flow between the two fiber connections. Test: Test Mode is used to run diagnostics, enable loopback and for running the Built In Link Tests. Note: The Operation Mode (Switch 1) affects the function of DIP Switches 2 and 3. Link Mode (Switch 2 Data Mode) Switch Position Up (default) Down Mode Smart Link Pass-Through Mode Standard Mode Smart Link Pass-Through: In this mode, the link state on one connection is directly reflected through the Media Converter module to the other connection. If fiber link is lost on one of the connections, then the other fiber link will be brought down by the Media Converter module Standard Mode: In this mode, the links can be brought up and down independently of each other. A loss of link on either fiber connection can occur without affecting the other fiber connection Perle 10G Media Converter module Installation Guide 7

Test Function (Switch 2 Test Mode) Switch Position Type Up (default) Down Built In Link Test Loopback Built In Link Test: Switch 2 causes the C/CM-10G media converter module to initiate the Built In Link Tests on the specified port. Switch 3 determines the specified port for the Built In Link Tests. If Switch 3 is Up, the tests will be run on Port 1. If the Switch is Down the tests will be run on Port 2. The other port will be disabled during these tests. These tests consist of the media converter module generating test patterns to be sent out the selected port to the remote media converter module. If the remote media converter module is a supported Perle media converter/module, the port will automatically be put into loopback mode. Loopback: If Switch 2 is down, the specified port will be put into loopback mode. In this mode, the port will be ready to receive the test patterns generated by another Perle media converter/module running the Built In Link Test. Switch 3 determines which port with be put into loopback mode. If the remote device is a supported Perle media converter/module, this unit does not need to be put into test mode and there is no need to set the loopback switch. This will be taken care of by the Auto Loopback Detect feature. Illustration of the Built In Link Test / Loopback Perle 10G Media Converter module Installation Guide 8

Local C/CM-10G Configuration Test Mode (Switch 1 Down) Test Function (Switch 2 Up) Remote-C/CM-10G Configuration All switches in the Up position Note: If the remote Media Converter module is not a supported Perle media converter/ module then the remote Media Converter /module will need to be put into loopback mode. See the documentation that came with that Media Converter module. Sequence of Events 1. The Local C/CM-10G Media Converter module sends the remote media converter/ module a signal to go into loopback mode. 2. The remote media converter/module turns on loopback mode. 3. Built In Test Data is sent from the Local C/CM-10G media converter module to the Remote media converter/ module 4. The Remote media converter module loops the received data back to the Local C/CM-10G Media Converter module. 5. Any test errors detected are displayed with the LEDs on the front of the Local C/CM-10G Media Converter module 6. The Built in Link Tests continue to run until Switch 1 on the Local C/CM-10G Media Converter module is set to Data mode Port Selection (Switch 3 Test Mode) Switch Position Port Up (default) 1 Down 2 When in Test Operating mode (Switch 1- down), this switch determines the port number. Fiber Fault Alert (Switch 3 Data Mode) Switch Position Mode Perle 10G Media Converter module Installation Guide 9

Up (default) Down Enabled Disabled Enabled: If the media converter module detects a loss of fiber, the media converter module will immediately notify the fiber link partner that an error condition exists. If the remote Media Converter module is set up for Fiber Fault Alert (FFA) Enabled and the local media converter is set up with Smart Link Pass-Through, a loss of fiber link on either the transmit or receive line will be passed through to the other fiber connection. Disabled: The Media Converter will not monitor for fiber fault. Illustration of the FFA feature Media Converter A Configuration Link Mode Standard Mode Fiber Fault Alert Media Converter B Configuration Link Mode Smart Link Pass through Mode Fiber Fault Alert Sequence of Events 1. Media Converter A loses fiber connection (RX). 2. Media Converter A notifies the remote Media Converter that there is a fault on the Link. 3. Media Converter B detects loss of fiber link on receiver RX. 4. Media Converter B turns off transmitter (TX). Perle 10G Media Converter module Installation Guide 10

EDC AutoDetect Mode (Switch 4 and Switch 5) SFP+ Models only Switch Position Up (default) Down Mode On Off On: When AutoDetect Mode is turned On, the C/CM-10G media converter module will establish the linear or limiting settings based on the contents of the EPROM on the module and module type. Off: When AutoDetect Mode is turned OFF, the C/CM-10G media converter module will select the alternative setting from that established by the determination above. Perle 10G Media Converter module Installation Guide 11

Operation Status LED The Perle 10G Media converters modules have three status LEDs located on the front panel of the module. PWR - Power/Test Green On: Power is on and the unit is in normal operation mode. Green blinking slowly: The unit is in test or loopback mode. Red blinking slowly while in Test mode: Indicates an error within the last second. Red Solid: During Power up: Hardware Error detected. (See PWR Red LED Errors) Red Blinking quickly: Error detected. See LK1 LK2 Error codes. Red (Solid or Blinking): A module has been inserted that is requesting more than the specified maximum power for that port. LK1- Port 1 Activity On: Fiber link present. Blinking quickly: Fiber link present and receiving data. Blinking slowly: The fiber link has been taken down as a result of Smart Link Pass-Through. Off: No fiber link present. LK2 Port 2 Activity On: Fiber link present. Blinking quickly: Fiber link present and receiving data. Blinking slowly: The fiber link has been taken down as a result of Smart Link Pass-Through. Perle 10G Media Converter module Installation Guide 12

Off: No fiber link present. LK1 LK2 Error Codes LK1 LK2 Meaning Off Off Incompatible SFP+ or XFP or speed mismatch on SFP+ Off On Power Budget exceeded XFP s requesting more power than specified port rating. On Off SFP+ or XFP communication error unable to communicate with module On On Internal Error PWR-Red LED Errors LK1 LK2 Meaning Blinking Blinking Blinking one second on, 3 seconds off: the maximum specified operating temperature within the inserted module has been exceeded Off Off Internal Hardware. Troubleshooting General Ensure power is supplied to the media converter use of the Perle supplied power adapter is highly recommended. Ensure that SFP+ or XFP modules are of the same speed and are operating properly. Ensure both devices on either end of each fiber are compatible. Ensure all cabling is of the correct type and is in good operating condition. For fiber connections, ensure the RX and TX has been reversed between the 2 media converters. No connectivity If unable to get full connectivity with all DIP switches in the UP position, this procedure is recommended for troubleshooting. If the remote device is not a Perle media converter/module the remote device needs to be put into loopback mode. Perle 10G Media Converter module Installation Guide 13

Initiate test mode on the local device (SW1 Down). If the PWR LED turns red or blinks red on a repeated basis, the fiber connection may require further testing. If the PWR LED stays green after several seconds of testing, then the link is passing the Built In Link Test. Proceed to testing the other link. Module Temperature Protection All C/CM-10G modules come equipped with module temperature protection. Should an inserted SFP+ or XFP module operate above its specified maximum operating temperature, the C/CM- 10G will reduce the power to that module/s. The C/CM-10G will continue to monitor the modules temperature until the temperature is below the maximum operating temperature and then the C/CM-10G will return the module/s to normal operating mode. Loopback Auto Detect Perle C/CM-10G media converter modules have the ability to automatically put remote supported Perle media converter/ modules into loopback mode. This allows the remote Perle media converter/module to be located in distant or inaccessible locations. The remote Perle media converter/module will remain in loopback mode as long as the tests are in progress. Note: Depending on the manufacturer some copper cabling may not support our Loopback Auto Detect feature, however Loopback Mode can always be obtained by setting switch 2 to the down position on your Perle Media converter module. Perle 10G Media Converter module Installation Guide 14

Technical Specifications The following applies to all Perle 10G Media Converter modules. Input Supply Voltage 9-30vDC Maximum power consumption (watts) Total Transceiver power supports (watts) Dual SFP 6.7* 3.0 Dual XFP XTX: 12.0* XTXH: 16.3* XTX: 7.0 XTXH: 11.0 Dual XFP to SFP XTX: 9.1* XTSH: 16.3* XTS:5.0 XTSH:7.0 Operating Temperature: 0 C -50 C (32 F - 122 F) Storage Temperature: -25 C -70 C (-13 F -158 F) Operating Humidity: 5% to 90% non-condensing Storage Humidity: 5% to 95% non-condensing Operating Altitude: Up to 3,048 m (10,000 ft) Weight: 0.15 kgs (0.3 lbs) *Maximum rating for both media converter and modules inserted. Actual rating is dependent on the power consumption of the SFP+/XPF modules inserted. Module Support MSA compliant SFP+ MSA complaint Class 1, 2 and 3 XFP modules for the C/CM- 10G-XTX models and C/CM-10G-XTS models. MSA complaint Class 1, 2, 3 and 4 XFP for the C/CM-10G- XTSH and C/CM-10G-XTSH models. 1G copper modules 1G fiber modules SFP+ supports C/CM1 (direct attach) interfaces XFP supports C/CM4 modules Fiber Cabling Requirements MM: SM: 50/125 microns 62.5/125 microns 9/125 microns Note: Please refer the product page on the Perle website for the most up to date specifications.http://www.perle.com/ Perle 10G Media Converter module Installation Guide 15

Compliance Information FCC This product has been found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions in this Guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his/her own expense. EN 55022 Class A WARNING This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. EN 55024 Class A Contacting Technical Support Contact information for the Perle Technical Assistance Center (PTAC) can be found at the link below. A Technical Support Query may be made via this web page. www.perle.com/support_services/support_request.shtml Warranty / Registration Perle s standard Lifetime Warranty provides customers with return to factory repairs for Perle products that fail under the conditions of the warranty coverage. Details can be found at: http://www.perle.com/support_services/warranty.shtml Copyright 2017 Perle Systems Limited All rights reserved. No part of this document may be reproduced or used in any form without written permission from Perle Systems Limited. Perle 10G Media Converter module Installation Guide 16