Communication Wiring Color Codes

Similar documents
RS-232 Connector Pin Assignments

CNE301 Network I Lab 04 Building a cross-over cable and configuring back2back network.

USB 2.0 RG port USB m Cat 5e Extender System. User Guide

A+ Guide to Managing & Maintaining Your PC, 8th Edition. Chapter 16 Networking Types, Devices, and Cabling

Student Lab Manual. Networks and Communications (COMP277L) SYSTEM PROPERTIES. Dr. Mohamed Ben Laroussi Aissa Room 11 A- 2.

Low Profile Hub. User Manual

USB 2.0 RG2304GE-LAN. 4-Port USB 2.0 Gigabit Ethernet LAN Extender System. User Guide

Lab - Building an Ethernet Crossover Cable

VMI. Technical Documentation. 600 Industrial Drive, New Bern, N.C (tel / fax /

Cat.6/5e UTP Patch Panels with 45 Jack

Contents. One Introduction 2. Two Installation 3 Front Panel 10base-T Ports 10/100base-TX Ports LEDs

LP-4CEUSXX Cat 5e Unshielded U/UTP Patch Cords

Prepared By: Eng. Wasan Fraihat

10 How to Setup a Home or Small Network

Getting Started with Modbus TCP/IP for AC Tech Drives

USB SuperBooster Transmitter Wall Plate

NM-541-MUX TECHNICAL APENDIX V1.00

USB. USB Operator Panel Installation - Mach3

Industrial IP67-rated. 4-Port 10/100/1000T 802.3at PoE. + 2-Port 10/100/1000T. Managed Ethernet Switch (-40~75 degrees C, 24V) IGS MP2MT

Ethernet UART System Administrator Setup Guide

8.0.1 Chapter 8 Introduction

DATA/TELECOMMUNICATIONS COURSE REFERENCE MANUAL. 1. Cabling Jargon

Contents. One Introduction 2. Two Installation 3 Front Panel Connecting Ports LEDs

USB 2.0 CAT5E/6/7 EXTENDER

Mini USB Extender USER MANUAL.

Modern Ethernet. Chapter 6

Industrial IP67-rated 4-Port 10/100/1000T at PoE + 2-Port 10/100/1000T. M12 Managed Ethernet Switch. (-40~75 degrees C) IGS-604HPT-M12

Mike Meyers CompTIA A+ Guide to Managing and Troubleshooting PCs Fourth Edition Visible Networks Chapter 5

USB-C5 USB-C5-CE USB EXTENDER Installation and User Guide

Changes or modifications not expressly approved by InFocus Corporation may void authority to operate the equipment.

USB 2.0 RG2304 Network Series

USB 2.0 Ranger High Speed Extender System. User Guide

CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.

COMPUTER ENGINEERING AND INFORMATION TECHNOLOGY DEPARTMENT NETWORK LABORATORY. Ethernet Cabling

Installation and Operation Manual

Contents 9-1. Network Media

ST-C5VRS-600 VIDEO AND RS232 EXTENDER Installation and Operation Manual

GigaSwitch 8. User Guide

USB 2.0 Ranger Port USB m Cat 5e Extender System. User Guide

Industrial IP67-rated 4-Port 10/100/1000T at PoE + 2-Port 10/100/1000T. Managed Ethernet Switch. (-40~75 degrees C) IGS-604HPT-RJ

with its cables, connectors, Switches, Hubs and topologies

USB 2.0 Ranger Port USB m CAT 5e/6/7 Extender System. User Guide

Uncle Ted's Guide To VDV Cabling (voice/data/video)

StarServe Harmonicas. Wiring Instructions. Shallow. Deep. Angled. Telephone Modules 8052/4RJ 8052/4RJDMB 8052/4RJSMB Angled 3105ATPP2X4

USB 2.0 Ranger High Speed Extender System. User Guide

FastHub Ports and Cabling Information

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Networking Instructions Transform Motorized Acoustical Banner

USB 400 USER MANUAL.

Appendix B Networks, Routing, and Firewall Basics

INFORMATION AND COMMUNICATION TECHNOLOGY

Ethernet Series. Etherplug Etherlink V Etherlink V Specifications Ethernet Series

ETH-4X1-G / 2X1-G / 2X1

Ethernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 12

Cables and Connectors

Ethernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 10

Network Fundamentals and Cabling TELECOMMUNICATION AND NETWORKING

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

USB Ranger User Guide. Cat 5 USB 2.0 Extender with Remote Power. Powered by

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

USB Raven Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide

SP x4 DVI over Single CAT5 Distribution Amplifier. User Manual. Made in Taiwan

Cabling Infrastructure

Lecture (07) Media & Switching III Ethernet Protocol & Network Hardware Components

Ethernet Media. Introduction Quick Selection Ethernet Media. Systems. PannelConnect Connection. Connection. Safety.

EL5353 DVI + USB 2.0 Extender DVI and USB m CAT 5e/6/7 KVM Extender System. User Guide

9/27/04 cci Cablecom Inc. 1

KVM - DVI, Audio, USB 2.0, Cat 5 Extender

12382 South Gateway Park Place, 700 Draper, UT

Kalo Attraction in simplicity

April 2017 Rev 1

EL5200 HDMI + USB 2.0 Extender HDMI and USB m Cat 5e KVM Extender System. User Guide

INSTALLATION INSTRUCTIONS. DCC and DCE Installation Instructions. Table of Contents

USB 3.1 CAT6A/7 EXTENDER

Transceiver Hub with Integral Camera Power

Troubleshoot Direct PC Connections to the Cisco ONS TCC, TCC+ or TCC2 Card

EXTENDER ELE8082. INSTALLATION Manual. Made in Taiwan

Connector and Cable Specifications

Termination for 568A and 568B pin configurations.

Quick Installation Guide

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Job Aid: Connector and Cable Diagrams (Pinout Charts)

EXTENDERS Installation and Operation Manual

ANSI/TIA/EIA-568-B Cabling Standard

PoE vs. Splitters, Y Cables, Non IEEE Power Injectors, and Misconnections

ANSI/TIA/EIA-568-B Cabling Standard

Installing the Cisco ATA

Chapter 3 Certifying Twisted Pair Cabling

VGA RS-232 Extender USER MANUAL.

2015 ECA TELECOM OPTIONS REVIEW

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Clarity 6 and 5e. Clarity 6 and Clarity 5E Modular to 110 Patch Panels. Clarity 6 and Clarity 5E Modular to 110 Mini Patch Panels

Wireless Area Controller (WAC50) i. Installation Instructions

EXTENDER ELE8081. INSTALLATION Manual. Made in Taiwan

FE8171V. 3MP 360 Panoramic View Vandal-proof

Twisted-Pair Cabling; Crossover Cables. Wiring standards for Ethernet cables using twisted-pair wires; Making and testing cables

Ethernet Test Access Panel (ETAP) User Manual

Active UTP Transceiver Hub with Integral Isolated Camera Power

Wireless Area Controller (WAC60)

VOPEX Series VOPEX-C5VA-xC1000 Video/Audio Splitter/Extender Installation and Operation Manual

Transcription:

Communication Wiring Color Codes Cat 5 & 5e Network Color Codes for RJ-45 Ethernet Plug Eight-conductor data cable (Cat 3 or Cat 5) contains 4 pairs of wires. Each pair consists of a solid color wire and a white and color striped wire. Each of the pairs are twisted together. To maintain reliability on Ethernet, you should not untwist them any more than necessary (about 1/4 inch). The pairs designated for 10BaseT Ethernet are orange and green. The other two pairs, brown and blue, are unused. The connections shown are specifically for an RJ45 plug. The wall jack may be wired in a different sequence because the wires may be crossed inside the jack. The jack should either come with a wiring diagram or at least designate pin numbers that you can match up to the color code below. There are two wiring standards for these cables, called T-568A and T-568B. They differ only in pin assignments, not in uses of the various colors. The illustration above shows both standards. With the T-568B specification the orange and green pairs are located on pins 1, 2 and 3, 6 respectively. The T-568A specification reverses the orange and green connections, so that the blue and orange pairs are on the center 4 pins, which makes it more compatible with the telco voice connections. T-568A is supposed to be the standard for new installations, and T-568B is the alternative. However, most off-the-shelf data equipment and cables seem to be wired to T568B. Pin Number Designations Here are the pin number designations for both standards:

T-568B Pin Color Pair Descrtipion 1 white/orange 2 TxData + 2 orange 2 TxData - 3 white/green 3 RecvData + 4 blue 1 Unused 5 white/blue 1 Unused 6 green 3 RecvData - 7 white/brown 4 Unused 8 brown 4 Unused T-568A Pin Color Pair Description 1 white/green 3 RecvData + 2 green 3 RecvData - 3 white/orange 2 TxData + 4 blue 1 Unused 5 white/blue 1 Unused 6 orange 2 TxData - 7 white/brown 4 Unused 8 brown 4 Unused Note: Odd pin numbers are always the striped wires..

Straight-Through vs Cross-Over In general, the patch cords that you use with your Ethernet connections are "straightthrough", which means that pin 1 of the plug on one end is connected to pin 1 of the plug on the other end (for either standard). The only time you cross connections in 10BaseT is when you connect two Ethernet devices directly together without a hub or connect two hubs together. Then you need a "cross-over" patch cable, which crosses the transmit and receive pairs. An easy way remember how to make a cross-over cable is to wire one end with the T-568A standard and the other with the T-568B standard. Termination UTP cables are terminated with standard connectors, jacks and punchdowns. The jack/plug is often referred to as a "RJ-45", but that's a telco designation for the "modular 8 pin connector" terminated with a USOC pinout used for telephones. The male connector on the end of a patchcord is called a "plug" and the receptacle on the wall outlet is a "jack." In LANs, as spec'ed by 568, there are two possible pinouts, called T568A and T568B, that differ only in which color coded pairs are connected - pair 2 and 3 are reversed. Either work equally well, as long as you don't mix them! If you always use only one version, you're OK, but if you mix A and B in a cable run, you will get crossed pairs! The cable pairs are color coded as Pair 1 is white-blue/blue, Pair 2 white-orange/orange, Pair 3 is white-green/green Pair 4 is white-brown/brown.

Jacks usually have punchdowns on the back or can be terminated without punchdowns using special manufacturer's tools or even a cover for the connector. Again, you MUST keep the twists as close to the receptacle as possible to minimize crosstalk. Note that Cat 3 jacks and all plugs are going to use these color codes. However, Cat 5 jacks have internal connections that continue the twists as close to the pins in the jacks as possible. Thus the pinout on the back of the jacks will not usually follow these layouts! Always follow the color codes on the back of the jacks to insure proper connections! Crossover Cables: Normal cables that connect a PC/NIC card to a hub are wired straight through. That is pin 1 is connected to pin 1, pin 2 to pin 2, etc. However, if you are simply connecting two PCs together without a hub, you need to use a crossover cable made by reversing pair 2 and 3 in the cable, the two pairs used for transmisson by Ethernet. The easy way to make a crossover cable is to make one end to T568A color coding and the other end to T568B. Then the pairs will be reversed. Punchdowns:

Punchdowns come in 4 varieties: 110, 66, Bix and Krone. Most popular for LANs is the 110 (on the left), for telcos it's the 66 (on the right), and the Bix and Krone are rare (price, proprietary designs, etc.) 110 block 66 block Color Codes For Punchdowns: Punchdowns of all types are always made with the pairs in order with the white/stripe wire first, then the colored wire, Pair 1(w/blue-blue), Pair 2 (w/orange-orange), Pair 3 (w/green-green), Pair 4 (w/brown-brown). (This color code is remembered by BLOG - BLueOrangeGreen and brown) Back to Design