RC315/316-FE (Rev. A) 10/100M Auto-negotiation Copper-to-Fiber Media Converter. User Manual. Raisecom Technology Co., Ltd.

Similar documents
User Manual. RC511/RC512 Series SNMP Manageable, Bandwidth Control, 10/100 Mbps Auto-Sensing Ethernet Copper to Fiber Media Converter

Fast Ethernet Converter. User Guide MICROSENS

RC414 Universal Optical Converter/Repeater User Manual

RCMS Modular Optical Multiplexer Manual

RC702-FX Ethernet over SDH User Manual

RC701/RC702-FE series Ethernet over SDH devices User Manual

10/100/1000Base-T to 1000Base-FX Switch Converter User Guide

TRP-C41 User s Manual

Preface. Media Converter

RC552-FE (A) User Manual

10/100BASE-TX to 100BASE-FX Media Converter. User s Guide. Rev. 01 (JUN. 2002) 1907M110MM16003 RECYCLABLE

CWGE2SFP. Commercial Grade 10/100/1000BASE-T(X) to 1000BASE-FX Gigabit Ethernet Media Converter INSTALLATION AND OPERATION MANUAL

Gigabit Fiber to Gigabit Fiber (100/1000) Media Converter. User Guide MS400230

10/100Base-TX to 100Base-FX Media Converter

Manual. Preface. XSNet 3100MC

Gigabit Ethernet Media Converter. User Manual

Gigabit Ethernet Media Converter

Read me first User's Manual Release Note

Media Converters & Chassis

1000M Gigabit Ethernet Media Converter with SFP Slot

Preface. Managed Media Converter Chassis System

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide

Switch manual Models &

Industrial Ethernet Optical Fiber Link Adapter FIB-IE-S User Manual

Signamax Connectivity Systems Dual Rate SFP Converter Series U S E R S

Signamax Connectivity Systems Industrial Ethernet Extender. User s Guide

RC905-EE1. Ethernet to E1 Interface Converter (REV.B) User Manual

M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide

Industrial PoE Media Converter

USER S MANUAL. 10/100/1000Base-T 1000Base-SX/LX Gigabit Ethernet Converter GEP-5300TF-C GEP-5400TF-C

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

KIS-MC M Media Converter

User Guide. MC100CM MC110CS Fast Ethernet Media Converter. MC111CS MC112CS WDM Fast Ethernet Media Converter

FB-10/100MMC Series Managed/Unmanaged. 10/100Mbps Fiber Media Converter User Manual

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

Signamax Connectivity Systems Gigabit Ethernet SFP Media Converter

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS. KC-300DM Series. Installation Guide

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

10/100M Ethernet Media Converter.

10/100Base-TX Industrial Ethernet Extender

Installation Guide. 100BASE-TX/100BASE-FX Fast Ethernet Media Converter NC-200FT/FC. -1-iIiNC-200FT/FC P/N:

Copyright PLANET Technology Corp Contents subject to revision without prior notice.

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

10/100Base-TX to 100Base-FX Media Converter

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

SWITCH, 8 GIGABIT PORTS ART. IPSWC080A. Please read this manual thoroughly before use and keep it for future reference

DynaGST/2402G. 24 Port 10/100/1000Base-T Gigabit Ethernet Switch with two SFP (mini) GBIC Slots PN: GEP-33224T USER S MANUAL

ETHERNET FIBER OPTIC CONVERTERS

PHB-200M PHB x 100/1000Base-T to 20x 100/1000Base-X

10/100/1000M Gigabit Ethernet Media Converter

Industrial 3-Port Fast Ethernet Media Converter Switches

Datasheet RCMS2802 FE Series Multiservice PDH Optical Multiplexer

Instruction Manual MX2-MM-LX-SC MXR2-MM-LX-SC MX2-SM-LX-SC MXR2-SM-LX-SC Media Converter

Chassis-based Media Converters

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS

10/100/1000Base-T to 1000Base-SX/LX Gigabit Media Converter

Hardened Media Converter

Gigabit Ethernet Media Converter

Product names mentioned in this manual may be trademarks or registered trademarks of those products and are hereby acknowledged.

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

The Gigabit Ethernet Media Converter fully complies with IEEE802.3ab 1000Base- T and IEEE802.3z 1000Base-SX/LX Gigabit Ethernet standards.

10/100Base-TX Industrial Ethernet Extender

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

PHB-200M PHB x 100/1000Base-T to 20x 100/1000Base-X FE/GbE Media Converter Concentrator

User Guide. FSW-1641TX/2441TX 16/24 10/100Base-TX Web Smart Switch. FSW-1641TX 16 port 10/100Base-TX Web Smart Switch

KFC-200. Installation Guide

F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Quick Start Guide. Physical Description. The Port Status LEDs

Quick Start Guide. Physical Description. Gigabit Ethernet Media Converter. User s Manual 1. Product Overview. DIP Switch

MIL-S24002TGxx. 24-port 10/100/1000 TX 2 Combo SFP Slots Unmanaged Switch. User Guide

PHB-200M/PHB x 100/1000Base-T to 20x100/1000Base-X SFP Patching Hub

OPCOM STM-1 High Capacity Terminal Multiplexer USER MANUAL. Raisecom Technology Co., Ltd (4/2005)

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

Industrial Ethernet Switch

USER S MANUAL. 5 and 8 Port 10/100/1000Base-T Gigabit Ethernet Switches

100Base-FX to 10/100Base-TX. PoE. Media Converter. FCU-1802Px. User s Manual

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Perle 10GT Media Converters

EIS-EXTEND-C-EU. Ethernet Coaxial Extender for 10/100 Networks. Extend Ethernet Coaxial Connections Up to 8530 Feet

Signamax Connectivity Systems FO Series 12-Port Media Converter

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

Gigabit Switch 8-Port 10/100/1000Mbit

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

EDG Port Industrial 10/100 Mbps Ethernet Switch. User Manual

Owner s Manual. Media Converters Models: N SC & N ST

Perle 10/100 Ethernet Media Converter Module. Installation Guide. P/N (Rev C)

SWITCH, 24 POE PORTS ART. IPSWP240A

FCC Statement. Trademarks. Preface. Gigabit Ethernet Media Converter

Hardened PoE Ethernet Switch

Perle S-10GRT-SFP Media Converter Installation Guide

S7055xM / S7075xM Web Smart Managed 5-Port / 7-Port 10/100 Fast Ethernet Switch w/vlan Support Installation Guide

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

BTS IP Media Converter. User Manual BTS BIT-RAYON GROUP

The configuration of the features can be done by the network management or the integrated configuration switches.

COMOSS FECON Series Media Converter Data Sheet. Overview

GSW-2453 Gigabit Chassis switch. User Guide

Transcription:

RC315/316-FE (Rev. A) 10/100M Auto-negotiation Copper-to-Fiber Media Converter User Manual Raisecom Technology Co., Ltd. Dec, 2005

CONTENT 1. SAFETY NOTICE...2 2. OVERVIEW...3 2.1. MODEL DESCRIPTION...3 3. TECHNICAL SPECIFICATION...4 3.1. OPTICAL PARAMETERS...4 4. CONSTRUCTION & INDICATOR...5 4.1. FRONT VIEW AND INDICATORS...5 5. FUNCTION & APPLICATION...7 5.1. INTERCONNECTING MEDIA CONVERTERS...7 5.2. CONNECTING MC WITH OTHER DEVICES (AT RJ45 PORT)...7 5.3. FULL DUPLEX CONFIGURATION (RJ45 PORT)...8 5.3.1. RC315/RC316-FE Series RJ45 Interface Auto-negotiation...8 5.3.2. RC315/RC316-FE Series RJ45 in Forced Status...8 5.4. CONNECTION WITH OTHER EQUIPMENT (AT OPTICAL PORT)...8 6. INSTALLATION & INSPECTION...9 6.1. MATCHING FIBER-OPTIC CABLE WITH MEDIA CONVERTER...9 6.2. TYPES OF FIBER-OPTIC CABLE...9 6.3. RJ45 INTERFACE...9 6.4. INSTALLATION OF CHASSIS (FOR RC316)...9 6.5. INSTALLATION OF DC POWER SUPPLY (FOR RC316)...10 6.6. AMBIENCE...10 6.7. POWER SUPPLY...10 6.8. DIMENSIONS...10 7. DIP-SWITCH CONFIGURATION... 11 7.1. EXPLANATION FOR SW4 SETUP:... 11 7.2. FACTORY DEFAULT SETUP FOR SW4... 11 8. NETWORK MANAGEMENT...12 8.1. CARD/MODULE INFORMATION REVIEW...12 8.2. MODULE CONFIGURATION...12 8.3. CARD RESET...12 1

1. Safety Notice Please read the following notice carefully before installing and using the device, Raisecom shall not be responsible for any loss that caused by violating safety notice. RC315/316-FE (Rev. A) has high sensitivity optical interface, so the power of optical transceiver output interface must be checked before connecting. To avoid damaging, it is not allowed that the optical power of transceiver s output interface is higher than that of RC315/316-FE. RC315/316-FE (Rev. A) is an integrated device which has precise elements, please avoid violent shake and impact, and do not disassemble or maintain the device yourself. If it is required, please do it under the guide of our technical staff following anti static steps. Please contact us if there is any need. There must be grounding protection for the sake of safety; do not disassemble the device yourself, we regard this as you waiver your rights of repair guarantee. 2

2. Overview 2.1. Model Description RC315/RC316-FE series media converters include the following product articles: RC315-FE-S1, RC315-FE-S2, RC316-FE-S1, and RC316-FE-S2. Part Number RC315-FE-S1 RC315-FE-S2 RC316-FE-S1 RC316-FE-S2 Description Stand-alone, 10/100Mbps auto-sensing, single strand, single mode, 0-25km, RJ45/SC-PC Stand-alone, 10/100Mbps auto-sensing, single strand, single Mode, 10-50km, RJ45/SC-PC Host site/remote site module, 10/100Mbps auto-sensing, single strand, single mode, 0-25km, RJ45/SC-PC Host site/remote site module, 10/100Mbps auto-sensing, single strand, single mode, 10-50km, RJ45/SC-PC 3

3. Technical Specification 3.1. Optical Parameters PART NUMBER Interface Wavelength (nm) Launch Power (dbmw) Receiving Sensitivity (dbmw) Typical Range (Km) Attenuation (db/km) RC315-FE-S1 SC/PC-RJ45 1310-12 ~ -3 < -30 0 ~ 25 0.5 RC315-FE-S2 SC/PC-RJ45 1310-12 ~ -3 < -30 0 ~ 25 0.5 RC316-FE-S1 SC/PC-RJ45 1550-5 ~ 0 < -32 10 ~ 50 0.5 RC316-FE-S2 SC/PC-RJ45 1550-5 ~ 0 < -32 10 ~ 50 0.5 4

4. Construction & Indicator 4.1. Front view and indicators 1. Front view of RC315/316-FE: Optical Receive Link Optical Data Active RJ45 Link RJ45 Data Active RLK TX RX ACT LINK ACT TLK Optical Transmit Link PWR 100M Power Rate FDX/COL Full Duplex/Collision Explanation of RC315/316-FE indicators: Interface Indicator Name Indicator The Status Explanation Optical Link Receive RLK ON: Optical receive link works in good condition; OFF: Optical receive link fails. Optical Interface Optical Transmit Link TLK ON: Optical transmit link works in good condition; OFF and RLK ON: Optical transmit link fails. Optical Data Active ACT Flashing: Transmitting data in Optical interface. RJ45 Link LINK ON: Rj45 link works in good condition; OFF: RJ45 link down. RJ45 Interface Duplex Mode /Collision FDX/COL ON: RJ45 works at full duplex mode; OFF: RJ45 works at half duplex mode; Flashing: Half duplex and collision occurs. RJ45 Data Active ACT Flashing: Transmitting data in RJ45 interface. Bit Rate 100M ON: Rate is 100M; OFF: Rate is 10M. Power Supply Power PWR ON: Power supply works in good condition; OFF: Power supply disconnected. 5

2. Front view of 16-slot chassis PWR PS1 PS2 5V 12V 5V 12V RAISECOM Explanation of the indicators on 16-slot chassis is as follows: PWR indicator: ON, chassis power supply works normal. PS1-5V indicator: OFF, power supply PS1 for modules works normal, otherwise abnormal. PS1-12V indicator: OFF, power supply PS1 for fans works normal, otherwise abnormal. PS2-5V indicator: OFF, power supply PS2 for modules works normal, otherwise abnormal. PS2-12V indicator: OFF, power supply PS2 for fans works normal, otherwise abnormal. 6

5. Function & Application 5.1. Interconnecting Media Converters When connecting with other media converters, it is required to comply with the specific connecting requirements according to the following table. Otherwise, link faults or abnormal data transmission will occur. Host Site RC316-FE-S1 RC316-FE-S2 Remote Site RC315-FE-S1 RC315-FE-S2 5.2. Connecting MC with Other Devices (at RJ45 Port) 1. RC315/RC316-FE series copper-to-fiber media converters have the function of MDI /MDIX auto-negotiation, so both straight-through and crossover cables can be used to connect with other equipment. 2. When RJ45 interfaces of RC315/RC316 series media converters work in the forced status, the MDI/MDIX auto-negotiation function may fail. So it is suggested that the following connection types on the forced status adopted. Media Converter Other Equipment RJ45 Cable Type Media Converter Switch Straight-through Media Converter HUB Straight-through Media Converter Router Crossover Media Converter Network Interface Card Crossover 7

5.3. Full Duplex Configuration (RJ45 Port) 5.3.1. RC315/RC316-FE Series RJ45 Interface Auto-negotiation When the RJ45 interface of RC315/RC316 media converter is configured to auto-negotiation, the copper port/rj45 of other network equipment must also be configured to auto-negotiation to ensure normal data transmission. If other equipment is working in forced status of full duplex mode, the media converters shall be fixed to Full Duplex Mode. 5.3.2. RC315/RC316-FE Series RJ45 in Forced Status When RC315/RC316 series media converter is working in forced status, the RJ45 duplex mode configuration of other network equipment must complies with the following table, to ensure proper data transmission. Media Converter RJ45 Mode 100M/Full Duplex 100M/Half Duplex 10M/Full Duplex 10M/Half Duplex Other Equipment RJ45 Mode 100M/Full Duplex 100M/Half Duplex 10M/Full Duplex 10M/Half Duplex 5.4. Connection with Other Equipment (at Optical Port) Several mandatory conditions are required: 1. The same bit rate 2. Matched optical power 3. Fast Ethernet protocol (IEEE 802.3u Fast Ethernet) 8

6. Installation & Inspection 6.1. Matching Fiber-Optic Cable with Media Converter RC315/316-FE-S1/2 series shall adopt single-mode single-strand fiber, and the connector shall be SC/PC. 6.2. Types of Fiber-Optic Cable Fiber-optic cable for multi-mode fiber port: 62.5/125um multi-mode fiber or 50/125um multi-mode fiber. Fiber-optic cable for single mode fiber port: 9/125um single mode fiber. 6.3. RJ45 Interface Cat.5 of twisted-pair shall be used. Please note that twisted-pair cables shall not be longer than 100 meters. For connection configuration, please see Chapter 2, Connection with Other Equipment (at RJ45 Port). 6.4. Installation of Chassis (for RC316) The chassis can be fixed onto 19 rack. The fixing accessories of chassis are in the accessory box. If fixing the chassis with the rear hole, there ll be 3cm space between the front edge of chassis and the front edge of the rack; if fixing with the front hole, the front edges will be in the same vertical level. 19" Standard Chassis Frame 9

6.5. Installation of DC Power Supply (for RC316) DC power supply provides three connectors: 48V, ground and 0V. These three connectors are connected respectively with 48V power cable, ground protection and 0V power cable. -48V 地 0V 6.6. Ambience Working temperature: -20-60 Humidity: 5%~90% non-condensing 6.7. Power Supply RC315 series: Stand-alone: 115/230V AC or 48V DC RC316 series: Single Slot Chassis: 115/230V AC or 48V DC 16-Slots Chassis: 115/230V AC or 48V DC Power consumption: 5W 6.8. Dimensions RC315 series: Standalone: 157(width)*32(height)*120(depth) mm RC316 series: Modular: 91(width)*25(height)*155(depth) mm 10

7. DIP-switch Configuration RC315/316-FE series media converter has an 8-bit dip-switch SW4. The functions for each bit are as follows in sequence: auto-sensing enable/disable, bit-rate 100M/10M, full duplex/half duplex, vacant (reserved), fault-pass-through disable/enable, frame length 1916 bytes/1536 bytes, and module type configuration. 7.1. Explanation for SW4 Setup: Switch Contents Status Configuration Details 1 RJ45 auto-sensing or manual setup 2 RJ45 manual 100M/10M setup ON OFF ON OFF RJ45 is configured as manual setup RJ45 is configured as auto sensing RJ45 manual setup: bit rate is 10M RJ45 manual setup: bit rate is 100M 3 RJ45 manual setup: Full Duplex/Half Duplex ON OFF If RJ45 manual setup: Half duplex If RJ45 auto-sensing: Auto-negotiation fails, working on half duplex mode If RJ45 manual setup: full duplex If RJ45 auto-sensing: Auto-negotiation fails, working on full duplex mode 4 Vacant (Reserved) 5 Fault-pass-through disable/enable ON OFF Enabled: If the optical link is disconnected, the RJ45 interface will be disabled Disabled: host RJ45 will always work ON Over-sized frame up to 1536 bytes 6 Over-sized frame configuration OFF Over-sized frame up to 1916 bytes Note: When SW4-1 is OFF (auto-sensing status), SW4-2 and SW4-3 will be disabled. SW4-7, SW4-8 are used to set up module types (it is prohibited for end-users to alter configuration). See the following table: SW4-7 SW4-8 Module Types OFF ON RC315/316-FE-S1 7.2. Factory Default Setup for SW4 On 1 2 3 4 5 6 7 8 Off 11

8. Network Management 8.1. Card/Module Information Review With network management software, the status of RC315/316 series can be reviewed at the host site, and controlled/configured. The status information on Show Module Info is as follows: No. Status Name/Control & Configure Items Options Control & Configure Features 1 Module type M, S1, S2, S3 Uncontrollable 2 Failure transfer Enable/disable Configurable 3 Frame length 1916Byte/1536Byte Configurable 4 Receive rate N * 32kb/s N is Configurable 5 Transmit rate N * 32kb/s N is Configurable 6 RJ45 interface Link status Up, Down Uncontrollable 7 RJ45 interface auto-negotiation Enable/manual Configurable 8 RJ45 interface control Open/close Configurable 9 RJ45 interface duplex status Full/half duplex Configurable 10 RJ45 interface rate 10M, 100M Configurable 11 Optical Interface: transmit Link Up, Down Uncontrollable 12 Optical Interface: receive Link Up, Down Uncontrollable 13 Optical Interface: signal Normal/abnormal Uncontrollable 8.2. Module Configuration Options such as receiving rate, transmitting rate and RJ45 interface, etc. can be configured through Configure Card. 8.3. Card Reset The host or remote-end modules can be reset through Host Card Reset. The frame length after the reset is 1,916Bytes, and the working mode of port RJ45 is auto-sensing. 12

@2005 Raisecom Technology Co., Ltd. All trademarks are the property of their respective owners. Technical information may be subject to change without prior notification. -V36 13