FLEX Ex Spring Clamp Terminal Base

Similar documents
Installation Instructions

Installation Instructions

FLEX Ex Bus Isolator and Flexbus Connector

Installation Instructions. FLEX I/O D-Shell Terminal Base Units and Distribution Boards

About the FLEX I/O and FLEX Ex I/O Systems

Allen-Bradley. User Manual. FLEX I/O Isolated Analog Modules. (Cat. No IF4I, -OF4I, and -IF2XOF2I)

FLEX Ex I/O 24V DC 4 Non-Isolated Source Output Module

User Manual Allen-Bradley

You cannot install the module unless the connector is fully extended. ATTENTION: Allen-Bradley HMIs

PHOENIX CONTACT - 01/2008

Installation Instructions

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

PHOENIX CONTACT - 12/2007

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-120VAC

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

F101, F102, F104. Relcom Installation Instructions. Fieldbus Power Supply F101-PS

About the FLEX Ex I/O Systems

CompactBlock Guard I/O EtherNet/IP Safety Modules

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

PanelView Plus/VersaView CE Terminals and Display Modules

ArmorPoint I/O Field Potential Distributor, Series A

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

FLEX I/O EtherNet/IP Adapter Module

Operating Instructions

General Specifications

PHOENIX CONTACT - 05/2007

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

General Specifications

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

DeltaV Bulk Power Supplies

MANUAL Surge Protectors

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

ETD-BL-1T-OFF-CC- 10S

Digital ac/dc (24V) Input Module

1756 ControlLogix Chassis Specifications

FP-PS-4. Features. Installation

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Redundancy Module QUINT-DIODE/40

User Manual (Cat. No IRT8)

Installation Instructions

CompactLogix Power Supplies Specifications

5 Fieldbus Technology

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

QuickPanel View & QuickPanel Control

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2

ControlLogix Redundant Power Supply Chassis Adapter Module

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Installation Instructions

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

MobileView Junction Box

TCNM-ACBB1 Installation Manual

1756 ControlLogix Chassis Specifications

Inductive sensor NI3-EG08K-Y1-H1341

POINT I/O Family. Chapter. Overview

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

Inductive sensor BI1.5-EG08-Y1-H1341

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

SUBCON-PLUS-PROFIB...

FLEX Integra 2 Input/2 Protected Output Module

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

PCI 2 Axis Servo Card

POINT I/O Family. Chapter. Overview

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

Inductive sensor BI5-EM18-Y1X-H1141

PCI 2 Axis Servo Card

Installation Instructions

POINT I/O PROFIBUS Adapter

NGC-40-BRIDGE. Control and Monitoring Modules for use with the nvent Raychem NGC-40 System Installation Instructions

Barriers. EB3N Discrete Input Barrier with Redundant Output

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

Velomitor* CT Velocity Transducer

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

You need the following to set up and use your terminal block:

Installing Your 1394 Drive Interface Module

FLEX Integra 4 Input Module

Allen-Bradley. User Manual. Remote I/O Adapter Module. (Cat. No ASB Series C and D)

Operating instructions

WARNING! ATTENTION! IMPORTANT

Installation & Operation Manual

DeltaV Bulk Power Supplies

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Industrial Power Supplies

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

Level-Lance Model 5400A

Inductive sensor BI1.5-EG08-Y1-H1341

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

Installation Instructions

S-series Horizontal Carriers

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Transcription:

Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification 1 Female flexbus connector 2 Terminal base unit 3 Male flexbus connector 4 Keyswitch - Set to the position required for the installed module 5 Mounting holes for panel mounting 6, 7, 8 Input/output terminal strips for connecting input/output wiring, -V, +V connections, chassis grounds 9 Locking tab 10 Module locking latch 11 Cover plug for male flexbus connector 12 96 pin female I/O connector You will need to rotate the keyswitch (4) to the correct position depending on the module. Refer to the module s installation instructions for more information. Do not change the position of the keyswitch after wiring the terminal base unit. FLEX Ex is a trademark of Rockwell Automation1

2 FLEX Ex Spring Clamp Terminal Base Make certain that you only connect terminal base units to other intrinsically safe system modules or adapters to maintain the integrity of the intrinsically-safe backplane. 41307 Installation in Zone 1 This terminal base unit must not be exposed to the environment. Provide a suitable metal enclosure. This terminal base unit has a protection factor of IP20. Do not remove the flexbus cover on the right-most terminal base unit. ATTENTION! This terminal base unit cannot be used in an intrinsically safe environment after it has been exposed to non-intrinsically safe signals. Do not remove the flexbus cover (11) on the right-most terminal base unit. Electrostatic Charge Protect the system against electrostatic charge. Post a sign near this module: Attention! Avoid electrostatic charge. For your convenience, a sign which can be cut out and posted is included in this installation instruction. European Community Directive Compliance If this product has the CE mark it is approved for installation within the European Community or EEA regions. It has been designed and tested to meet the following directives.

FLEX Ex Spring Clamp Terminal Base 3 EMC Directive This product is tested to meet the Council Directive 89/336/EC Electromagnetic Compatibility (EMC) by applying the following standards, in whole or in part, documented in a technical construction file: EN 50081-2 EMC - Generic Emission Standard, Part 2 - Industrial Environment EN 50082-2 EMC - Generic Immunity Standard, Part 2 - Industrial Environment This product is intended for use in an industrial environment. Ex Directive This product is tested to meet the Council Directive 94/9/EC (ATEX 100a) Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres by applying the following standards: EN50014:1992, Electrical Apparatus for Potentially Explosive Atmospheres EN50020:1994, Electrical Apparatus for Potentially Explosive Atmospheres - Intrinsic Safety i

4 FLEX Ex Spring Clamp Terminal Base UL, C-UL Certification If this product has the UL/C-UL mark, it has been designed, evaluated, tested, and certified to meet the following standards: UL 913, 1988, Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II, and III Division 1, Hazardous (Classified) Locations UL 1203, Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations UL 2279, Electrical Equipment for Use in Class I, Zone 0, 1, and 2 Hazardous (Classified) Locations UL 508, Industrial Control Equipment CSA C22.2 No. 157-92, Intrinsically Safe and Non-Incendive Equipment for Use in Hazardous Locations CSA C22.2 No. 30-M1986, Explosion-Proof Enclosures for Use in Class I Hazardous Locations CSA-E79-0-95, Electrical Apparatus for Explosive Gas Atmospheres, Part 0: General Requirements CSA-E79-11-95, Electrical Apparatus for Explosive Gas Atmospheres, Part 11: Intrinsic Safety i CSA C22.2 No. 14-95, Industrial Control Equipment FM Certification If this product has the FM mark, it has been designed, evaluated, tested, and certified to meet the following standards: FM C1. No.3600:1998, Electrical Equipment for Use in Hazardous (Classified) Locations General Requirements FM C1. No.3610:1999, Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II, III Division 1 Hazardous (Classified) Locations FM C1. No.3615:1989, Explosionproof Electrical Equipment General Requirements FM C1. No.3810:1989, 1995, Electrical and Electronic Test, Measuring and Process Control Equipment ANSI/NEMA 250, 1991, Enclosures for Electrical Equipment

Inputs/Outputs FLEX Ex Spring Clamp Terminal Base 5 Do not apply any non-instrinsically safe signals to this terminal base. When using as an intrinsically safe electrical apparatus according to EN50020, the European directives and regulations must be followed. The terminals in this terminal base unit may be electrically connected to each other by the insertion of FLEX Ex I/O modules. See the module installation instructions to determine this. IMPORTANT When interconnecting several lines, you must consider the total accumulated power and check for intrinsic safety requirements. Description The 1797-TB3S terminal base has 36 wiring connections to/from a plug-in module. The use of each terminal depends on the module mounted in this base. The 1797-TB3S terminal base also has connections for cold junction compensation and terminals designated for shield termination to chassis ground. The terminal base is equipped with a factory-installed tab cover for the backplane bus connection. The tab cover may be removed only when the terminal base unit is connected to other terminal base units. Wiring Connections for Terminal Base 1797-TB3S 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 36 37 38 39 40 41 51 42 43 44 45 46 35 47 48 49 50 34 Label placed at top of wiring area Row A Row B Row C Row A Row B Row C +V -V -V +V No connections allowed to terminals 36 and 49 41254

6 FLEX Ex Spring Clamp Terminal Base To connect wiring, insert a blade-type screwdriver with a blade width of 0.100-0.120in. (2.54-3.05mm) into the slot above the selected wiring port and lift up. Insert the wire while holding the screwdriver up. Release the upward screwdriver pressure to secure the wire. ATTENTION! Make certain that you power this terminal base unit with an intrinsically safe power supply. Do not exceed the values listed in the specifications for this terminal base unit. Do not use the unused terminals on this terminal base unit. Using these terminals as supporting terminals can result in damage to modules and/or unintended operation of your system. Mounting on a DIN Rail ATTENTION! Do not remove or replace a terminal base unit when power is applied. Interruption of the flexbus can result in unintended operation or machine motion. 1. Remove the cover plug in the male connector of the unit to which you are connecting this terminal base unit. 2. Check to make sure that the 16 pins in the male connector on the adjacent device are straight and in line so that the mating female connector on this terminal base unit will mate correctly. 3. Make certain that the female flexbus connector is fully retracted into the base unit.

FLEX Ex Spring Clamp Terminal Base 7 4. Position the terminal base over the 35 x 7.5mm DIN rail A (A-B pt. no. 199-DR1). A A Position terminal base at a slight angle and hooked over the top of the DIN rail A. 41114 41115 Slide the terminal base over tight against the adapter (or proceeding terminal base). Make sure the hook on the terminal base slides under the edge of the adapter and the flexbus connector is fully retracted. ATTENTION! Do not force the terminal base into the adjacent modules. Forcing the units together can bend or break the hook and allow the units to separate and break communication over the backplane.

8 FLEX Ex Spring Clamp Terminal Base 5. Rotate the terminal base onto the DIN rail with the top of the rail hooked under the lip on the rear of the terminal base. Use caution to make sure that the female flexbus connector does not strike any of the pins in the mating male connector. 41116 Press down on the terminal base unit to lock the terminal base on the DIN rail. If the terminal base does not lock into place, use a screwdriver or similar device to open the locking tab, press down on the terminal base until flush with the DIN rail and release the locking tab to lock the base in place. Gently push the flexbus connector into the side of the adapter to complete the backplane connection. 41117 6. For specific wiring information, refer to the installation instructions for the module you are installing in this terminal base unit. 7. Repeat the above steps to install the next terminal base. 8. Be sure the flexbus connector cover on the last terminal base is in place.

FLEX Ex Spring Clamp Terminal Base 9 Wiring 1. Make wiring connections as described in the installation instructions included with the specific module that mounts on your terminal base unit. 2. Connect +V and -V from this terminal base unit to the next using jumpers or individual external wiring, if appropriate due to total module power consumption. Daisy-chaining You can use the daisy chain configuration if the total module power draw is <8.5W. +V, -V Otherwise, power is connected to individual modules. Combination Wiring when total module current power is less than 8.5W 41110 +V, -V <8.5W +V, -V <8.5W Wiring when total module current power is greater than 8.5W 41111 Other variations are possible depending upon individual module power. ATTENTION! Do not use any unused terminals on this terminal base unit. Using these terminals as supporting terminals can result in damage to the module and/or unintended operation of your system.

10 FLEX Ex Spring Clamp Terminal Base Mounting Dimensions 3.7 (94) 3.7 (94) 2.7 (69) Inches (Millimeters) 41342 Repair This terminal base unit is not field-repairable. Any attempt to open this terminal base unit will void the warranty and IS certification. If repair is necessary, return this module to the manufacturer. About the Mounting Kit Use the optional 1794-NM1 mounting kit to mount your system on a panel or wall without a DIN rail. 1794-NM1 Mounting Kit with 18 screws (2 screws for the adapter and 2 screws for each module) 30238

FLEX Ex Spring Clamp Terminal Base 11 1797-TB3S Specifications Number of Terminals 1 row of 16, 2 rows of 18 Terminal Type Spring-clamp - To open, insert bladed screwdriver (0.100-0.120in/2.54-3.05mm) and lift up. Terminals Assignments 1 Only for intrinsically safe circuits +34, -35, +50, -51, and 96 U i <10V dc pin female I/O connector I i <2.5A pins i 30-32, 62-64, 94-96 i C i <1nF L i Negligible 36, 49 Must not be used for any connection All Other Terminals U i <30V dc I i <100mA C i <1nF L i Negligible Flexbus Connection U i <10V dc Intrinsically Safe I i <400mA C i <1nF L i Negligible Isolation Voltage Channel-to-channel isolation determined by inserted module Weight 200g (approximately) Dimensions (with module installed in base) Inches (Millimeters) 3.7H x 3.7W x 2.7D (94H x 94W x 69D) Environmental Conditions Operational Temperature -20 to 70 o C (-4 to 158 o F) Storage Temperature -40 to 85 o C (-40 to 185 o F) Relative Humidity 5 to 95% noncondensing Shock Operating Tested 15g peak acceleration, 11 (±1)ms pulse width Non-Operating Tested 15g peak acceleration, 11 (±1)ms pulse width Vibration Tested 2g @ 10-500Hz per IEC 68-2-6 Conductors Wire Size 12 gauge (4mm 2 ) stranded maximum 1.2mm (3/64in) insulation maximum Agency Certification CENELEC II 2G EEx ia IIC T4 UL, C-UL Class I Division 1 & 2 Groups A-D T4 Class I Zone 1 & 2 AEx ia IIC T4 FM Class I Division 1 & 2 Groups A-D T4 Class I Zone 1 & 2 AEx ia IIC T4

12 FLEX Ex Spring Clamp Terminal Base 1797-TB3S Specifications Continued Certificates CENELEC DMT 98 ATEX E012 U UL, C-UL UL Certificate Number 99.19699 C US Class I Division 1 Hazardous FM FM Certificate Number 3009806 FM 1 Termination connections are unique with each I/O module. Refer to the appropriate I/O module s installation instructions.

1 +V 2 -V 3 +V 4 -V FLEX Ex Spring Clamp Terminal Base 13 2.0 (50).83 (21) Inches (Millimeters)! 1.4 (35.5) 2.3 (58.5) 1.4 (35.5) Be careful of metal chips when drilling cable mounting holes. Do not drill holes above a system that has any modules installed. 2.3 (58.5) 1.4 (35.5) Cable length approximately 11.5 (292.1) or 35.5 (901.0) from upper connector [length depends upon cable -1ft (0.3m) or 3ft (0.091m)] 1.6 (40.5).61 (15.6).3 (8) 40871

14 FLEX Ex Spring Clamp Terminal Base IMPORTANT For detailed certification information, refer to the FLEX Ex System Certification Reference Manual, publication 1797-6.5.6. Attention: Avoid electrostatic charge.

FLEX Ex Spring Clamp Terminal Base 15 Notes:

Notes: PN 957395-61 Supersedes Publication 1797-5.2 - September 1999 2001 Rockwell International Corporation. Printed in USA