SED2 Variable Frequency Drives

Similar documents
SED2 Variable Frequency Drives

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

HVAC Products. Introducing the SED2 Variable Frequency Drives

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

SED2 Variable Frequency Drives

5 MICROMASTER 420 specifications

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013

Variable Frequency Drives

5 MICROMASTER 440 specifications

Easy To Use OEMS Take Note

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

It s fun to save. micromaster

SED2 Variable Frequency Drives Startup, Operation, and Maintenance Manual

Q9 ASD LOW VOLTAGE DRIVE

VLT 2800 DRIVE SPECIFICATIONS

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

Master the elements in building automation siemens.com/sinamics-g120x

PowerFlex 400 AC Drive Guide Specification

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

SENSORLESS VECTOR CONTROL

PowerFlex 40 Sample Specification

Built-in features Built-in simplicity Built for fans & pumps

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

SSW06. Soft Starters.

Q-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES

CATALOG SELECTION / PRODUCT SELECTION

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

Master the elements in water and wastewater applications siemens.com/sinamics-g120x

SD250 VARIABLE SPEED DRIVE

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

A drive dedicated to variable speed control for HVAC applications

VARIABLE FREQUENCY DRIVES

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

ATV61HU55M3 ATV61 5,5 kw 7,5HP 240V single phase EMC IP20

Motor Controllers AC Variable Frequency Drives Type Variflex 3 RVLF Advance

Motor Controllers AC Variable Frequency Drives Type Variflex 3 RVLF Advance

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVLF

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

ABB Component Drives ACS55, 0.25 to 3 Hp

Variable Speed Drive for pumps and fans

ATV1200A kv kva

ATV1200A kv kva

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

TR200 DRIVE STANDARD FEATURES

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

Technical Data and Specifications. Table 1. LCX9000 Specifications. Drive Efficiency > 95% Power Factor (Displacement).96

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter

Low Voltage Drives. ABB component drives ACS55, 0.25 to 3 hp (0.18 to 2.2 kw) Catalog

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

MICROMASTER 4 th. Generation. A&D SD Thailand MM4 Next.Generation /50

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

VARIABLE SPEED DRIVES

Affinity. Dedicated HVAC/R Drive for Building Automation. 1.1kW to 132kW (1.5hp to 200hp) 200V / 400V / 575V / 690V IP20 (NEMA 1) and IP54 (NEMA 12)

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

Operating comfort redefined Frequency Inverters M-MAX

ADJUSTABLE SPEED DRIVES. Q9 Series

For additional PowerFlex 4M data and general drive information, refer to the following publications:

VARIABLE SPEED DRIVES

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

VFD 4x STAINLESS STEEL ENCLOSURE WITH AC. engineering data and specifications

TR200 DRIVE WITH ELECTRONICALLY CONTROLLED BYPASS SYSTEM

VARIABLE SPEED DRIVES

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF

MOTOR STARTERS & VARIABLE SPEED DRIVES Variable speed drives

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF

TR150 DRIVE STANDARD FEATURES

MP7. Uninterruptible Power Supply

C. New or replacement products installed in existing facilities shall be consistent with existing equipment.

vacon 100 hvac for indoor climate control

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

ACH550 Product Overview

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

Overview This document is giving a brief introduction how to choose correct BFI in a specific application. Things marked with red is a must condition.

ADJUSTABLE SPEED DRIVES. QX7 Series. HVAC 18-Pulse. Phone: Fax: Web:

Submittal Data Information SmartDRIVE HVAC Variable Speed Drives

Neon pr. ph/ ORP measurement. Applications. Description

Section 16. Drives AF-650GP General Purpose Drive. Standard Specifications. Environmental Conditions. Logic Controller (LC) Sequencer

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

The SV9000. The Comprehensive Drive Solution.

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

SX90 Process Controller

Global Field Devices COMMERCIAL HVAC COMPONENTS ENGINEERED FOR SUCCESS. Application And Selection Guide

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

ATV212WU55N4 variable speed drive ATV kW - 7.5hp - 480V - 3ph - EMC class C2 - IP55

ATV32H055N4 variable speed drive ATV kw V - 3 phase - with heat sink

ABB component drive ACS50, 0.18 to 2.2 kw Technical catalogue PRODUCTS

Transcription:

SED2 Variable requency Drives Description The SED2 variable frequency drives are designed specifically for HVA applications. The SED2 supports a wide variety of digital and analog I/O for diverse control capability. Built-in PID features control pumps and fans, and an integral system protocol can interface P1/N2 networks. Using the SED2 multi-level parameter access, operators can quickly pinpoint relevant data. eatures Built-in SBT P1 and JI N2 (Metasys ) building automation system protocols for easy network integration LON Interface and Modbus Interface optional Low harmonics design reduces noises and interference eliminates need for filters/reactors in most installations Built-in PID for fast and accurate pressure control Pump staging for open loop, constant pressure, and constant flow-type applications Multi-level program access Belt failure detection with or without an external sensor Service mode for applications requiring continuous, uninterruptible operation Accepts a wide variety of digital and analog I/O types, including direct Ni 1000 RTD sensor level inputs One common interface throughout all power ranges Optional Advanced Operator Panel for uploading/downloading parameters ull form relay contacts for digital outputs s SED2 IP20 and NEMA Type 1 frame sizes and power ranges are as follows: HP.5.7 1 1.5 2 3 4 5 7.5 10 15 20 25 30 40 50 60 75 100 125 kw.37.5.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 19 22 30 37 45 55 75 90 240V 575V A B D E A B SED2 IP54/NEMA Type 12 frame sizes and power ranges are as follows: D E HP.5.7 1 1.5 2 3 4 5 7.5 10 15 20 25 30 40 50 60 75 100 125 kw.37.5.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 19 22 30 37 45 55 75 90 575V B D E Siemens Building Technologies, Inc. http://www.sbt.siemens.com/hvp/drives Page 1 of 7

SED2 Variable requency Drives Product Numbers Your Product Number: Example Product Number: S E D 2-0. 7 5 / 2 2 X Model SED2- VD only kw rating 0.37, 0.55, [See Note 1 for these selections] 0.75, 1.1, 1.5, 2.2, (Uses 2 to 4 3, 4, 5.5, 7.5, 11, 15, spaces plus 18.5, 22, 30, 37, 45, a divider "/") 55, 75, 90 [See Note 2 for these selections] Voltage 2 200 to 240V 3 380 to 4 500 to 600V NEMA rating 2 (IP 20) 1 NEMA Type 1 5 NEMA Type 12 (IP 54) [See Note 2] ilter X actory Required Designator *** leave blank *** Notes: 1. Available only with Voltage odes 2 and 3. 2. Available only with Voltage odes 3 and 4. Example Shown: SED2-0.75/22X SED2 VD only, 0.75 kw (1 hp), 200 to 240V, open type IP20. Typical Specifications SED2 shall provide control of fan and pump HVA applications. A wide range of I/O allows for simple control solutions, with integral P1 and N2 protocols embedded for full control capabilities. Page 2 of 7 http://www.sbt.siemens.com/hvp/drives Siemens Building Technologies, Inc.

SED2 Variable requency Drives Submittal Sheet Technical Data Table 1. Drive Specifications. Drive Specifications Description Input voltage and power ranges 208V and 230V to 240V, 3 ac±10%. 1/2 hp to 60 hp (3-phase) 380V to, 3 ac ±10% 1/2 hp to 125 hp 500V to 600V, 3 ac ±10% 1 hp to 125 hp Input frequency 47 Hz to 63 Hz Output frequency 0 Hz to 150 Hz Power factor 0.9 VD degree of efficiency 96% to 97% Switch-on current Less than nominal input current Auxiliary supply 24V Glavanically separated, unregulated auxiliary supply (18V to 32V) 100 ma Overload capacity 110% for 60 seconds ontrol method Linear, parabolic and programmable V/f; and flux current control low-power mode PWM frequency 2k Hz to 16k Hz (adjustable in 2k Hz increments) ixed frequencies 15 programmable Skip frequency bands 4 programmable Setpoint resolution 0.01 Hz digital 0.01 Hz serial 10 bit analog Digital inputs (sink/source) 6: fully programmable and scalable isolated digital inputs, switchable Analog inputs 2: 0 to 10 Vdc, 0/4 to 20 ma, can also be configured as digital inputs or Ni 1000 input Relay outputs 2: configurable 30 Vdc/5A (resistive), 250 Vac/2A (inductive) Analog outputs 2: programmable (0/4 ma to 20 ma, or 0 Vdc to 10 Vdc) Serial interface RS-485 transmission rate: Up to 38.4k Baud Protocols: USS, P1 and N2 Protection level IP20 NEMA Type 1 with protective shield and gland plate installed IP54/NEMA Type 12 Temperature ranges Operating: 14 to 104 ( 10 to 40 ) Storage: 40 to 158 ( 40 to 70 ) Humidity 95% rh, non-condensing Operational altitudes Up to 3280 ft (1000m) above sea level without derating Protection features Under-voltage, Over-voltage, Overload, Ground fault, Short circuit, Stall prevention, Locked motor, Motor overtemperature l 2 t PT, Over-temperature, Parameter PIN protection. Standards UL, cul, E, -tick E conformity onformity with E Low Voltage Directive 73/23/EE NOTE: SED2 ompliance with EN61000-3-12: rom September 1st, 2005 all electrical apparatus covered by the EM directive will have to comply with EN61000-3-12 Limits for harmonic currents produced by equipment connected to public low voltage systems with input currents > 16A and =< 75 A per phase. Siemens variable speed drives of the product range SED2 (Micromaster 436) fulfill the requirements of the EN 61000-3-12 (without the need for external line reactors) regarding the THD values of Table 3 under the pre condition of Rsce > 190. The required PWHD values will not be achieved. Due to this fact it is recommended to apply for connection approval at the local electricity board. The local electricity board will evaluate among many other data the content of the 5th harmonic current and the Line Power actor "Lambda, which is the ratio of active power and apparent power. Siemens frequency inverters are optimized in design and operation characteristics regarding energy efficiency and less interference with line supplies. Siemens Building Technologies, Inc. http://www.sbt.siemens.com/hvp/drives Page 3 of 7

SED2 Variable requency Drives Voltage Table 2. Output Ratings. Product Number Output Rating (±10%) IP20 NEMA Type 1 IP54/NEMA Type 12 HP kw 208V and 230V to 240V 380V to 500V to 600V Output urrent Max (amps) SED2-0.37/22X SED2-0.37/21X 0.5 0.37 2.3 A SED2-0.55/22X SED2-0.55/21X 0.75 0.55 3.0 A SED2-0.75/22X SED2-0.75/21X 1.0 0.75 3.9 A SED2-1.1/22X SED2-1.1/21X 1.5 1.1 5.5 B SED2-1.5/22X SED2-1.5/21X 2.0 1.5 7.4 B SED2-2.2/22X SED2-2.2/21X 3.0 2.2 10.4 B SED2-3/22X SED2-3/21X 4.0 3.0 13.6 SED2-4/22X SED2-4/21X 5.0 4.0 17.5 SED2-5.5/22X SED2-5.5/21X 7.5 5.5 22.0 SED2-7.5/22X SED2-7.5/21X 10.0 7.5 28.0 SED2-11/22X SED2-11/21X 15.0 11.0 42.0 D SED2-15/22X SED2-15/21X 20.0 15.0 54.0 D SED2-18.5/22X SED2-18.5/21X 25.0 18.5 68.0 D SED2-22/22X SED2-22/21X 30.0 22.0 80.0 E SED2-30/22X SED2-30/21X 40.0 30.0 104.0 E SED2-37/22X SED2-37/21X 50.0 37.0 130.0 SED2-45/22X SED2-45/21X 60.0 45.0 154.0 SED2-0.37/32X SED2-0.37/31X 0.5 0.37 1.2 A SED2-0.55/32X SED2-0.55/31X 0.75 0.55 1.6 A SED2-0.75/32X SED2-0.75/31X 1.0 0.75 2.1 A SED2-1.1/32X SED2-1.1/31X SED2-1.1/35X 1.5 1.1 3.0 A * SED2-1.5/32X SED2-1.5/31X SED2-1.5/35X 2.0 1.5 4.0 A * SED2-2.2/32X SED2-2.2/31X SED2-2.2/35X 3.0 2.2 5.9 B SED2-3/32X SED2-3/31X SED2-3/35X 4.0 3.0 7.7 B SED2-4/32X SED2-4/31X SED2-4/35X 5.0 4.0 10.2 B SED2-5.5/32X SED2-5.5/31X SED2-5.5/35X 7.5 5.5 13.2 SED2-7.5/32X SED2-7.5/31X SED2-7.5/35X 10.0 7.5 18.4 SED2-11/32X SED2-11/31X SED2-11/35X 15.0 11.0 26.0 SED2-15/32X SED2-15/31X SED2-15/35X 20.0 15.0 32.0 SED2-18.5/32X SED2-18.5/31X SED2-18.5/35X 25.0 18.5 38.0 D SED2-22/32X SED2-22/31X SED2-22/35X 30.0 22.0 45.0 D SED2-30/32X SED2-30/31X SED2-30/35X 40.0 30.0 62.0 D SED2-37/32X SED2-37/31X SED2-37/35X 50.0 37.0 75.0 E SED2-45/32X SED2-45/31X SED2-45/35X 60.0 45.0 90.0 E SED2-55/32X SED2-55/31X SED2-55/35X 75.0 55.0 110.0 SED2-75/32X SED2-75/31X SED2-75/35X 100.0 75.0 145.0 SED2-90/32X SED2-90/31X SED2-90/35X 125.0 90.0 178.0 SED2-0.75/42X SED2-0.75/41X 1.0 0.75 1.4 SED2-1.1/42X SED2-1.1/41X SED2-1.1/45X 1.5 1.1 2.1 SED2-1.5/42X SED2-1.5/41X SED2-1.5/45X 2.0 1.5 2.7 SED2-2.2/42X SED2-2.2/41X SED2-2.2/45X 3.0 2.2 3.9 SED2-3/42X SED2-3/41X SED2-3/45X 4.0 3.0 5.4 SED2-4/42X SED2-4/41X SED2-4/45X 5.0 4.0 6.1 SED2-5.5/42X SED2-5.5/41X SED2-5.5/45X 7.5 5.5 9.0 SED2-7.5/42X SED2-7.5/41X SED2-7.5/45X 10.0 7.5 11.0 SED2-11/42X SED2-11/41X SED2-11/45X 15.0 11.0 17.0 SED2-15/42X SED2-15/41X SED2-15/45X 20.0 15.0 22.0 SED2-18.5/42X SED2-18.5/41X SED2-18.5/45X 25.0 18.5 27.0 D SED2-22/42X SED2-22/41X SED2-22/45X 30.0 22.0 32.0 D SED2-30/42X SED2-30/41X SED2-30/45X 40.0 30.0 41.0 D SED2-37/42X SED2-37/41X SED2-37/45X 50.0 37.0 52.0 E SED2-45/42X SED2-45/41X SED2-45/45X 60.0 45.0 62.0 E SED2-55/42X SED2-55/41X SED2-55/45X 75.0 55.0 77.0 SED2-75/42X SED2-75/41X SED2-75/45X 100.0 75.0 99.0 SED2-90/42X SED2-90/41X SED2-90/45X 125.0 90.0 125.0 * IP54/NEMA Type 12 drives start at B. Page 4 of 7 http://www.sbt.siemens.com/hvp/drives Siemens Building Technologies, Inc.

SED2 Variable requency Drives Submittal Sheet Accessories Gland Plates (included with NEMA Type 1): SED2-GL-A Gland Plate, A SED2-GL-B Gland Plate, B SED2-GL- Gland Plate, Protection Shield (included with NEMA Type 1): SED2-PS-A Protection Shield, A SED2-PS-B Protection Shield, B SED2-PS- Protection Shield, SED2-PS-DE Protection Shield, D, E Operator Panel: SED2-BOP1 SED2-AOP1 Basic Operator Panel (included with all SED2s) Advanced Operator Panel BOP/AOP Door Mounting Kits: SED2-DOOR-KIT1 BOP/AOP Single Inverter Door Mounting Kit SED2-DOOR-KIT2 AOP Multi-Inverter Door Mounting Kit Dimensions Table 3. Overall Dimensions for IP20 SED2 VDs in Inches (Millimeters). A 6.8 (173) 2.9 (73) 5.9 (149) 2.9 (1.3) B 8.0 (202) 5.9 (149) 6.8 (172) 7.5 (3.4) 9.6 (245) 7.3 (185) 7.7 (195) 12 (5.5) D 20.5 (520) 10.8 (275) 9.6 (245) 35 (16) E 25.6 (650) 10.8 (275) 9.6 (245) 44 (20) 33.5 (850) 13. (350) 12.6 (320) 116 (53) Table 4. Overall Dimensions for NEMA Type 1 SED2 VDs Assembled with Protective Shield and Gland Plate in Inches (Millimeters). A 9.1 (231) 2.9 (73) 5.9 (149) 3.2 (1.5) B 11.8 (300) 5.9 (149) 6.8 (172) 8.3 (3.8) 13.8 (351) 7.3 (185) 7.7 (195) 13.6 (6.2) D 24.6 (625) 10.8 (275) 9.6 (245) 37.5 (17) E 29.7 (754) 10.8 (275) 9.6 (245) 46.4 (21) 54.5 (1384) 16.0 (406) 14.0 (356) 200 (91) LON Interface Option SED2-LONI/ Modbus Interface able SED2-MODBUS1 onverts VD's USS bus to Modbus RTU Table 5. Overall Dimensions for IP54/NEMA Type 12 SED2 VDs in Inches (Millimeters). B 15.2 (385) 10.6 (270) 10.6 (268) 10 (22) 23.9 (606) 13.8 (350) 11.2 (284) 42 (19) D 27.0 (685) 14.2 (360) 13.9 (353) 77 (35) E 34.8 (885) 14.2 (360) 17.8 (453) 105 (48) 45.3 (1150) 17.7 (450) 18.6 (473) 178 (81) Siemens Building Technologies, Inc. http://www.sbt.siemens.com/hvp/drives Page 5 of 7