Pressure switch, Differential pressure switch RT

Similar documents
Pressure switch, Differential pressure switch RT

Pressure switch KP. Data sheet

Pressure switch Type KP

Pressure controls, Type KP

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.

for for Industrial Refrigeration

Pressure switch KP. Data sheet

Pressure switch KP. Data sheet

Pressure switches and thermostats, types KP and KPI

21D Allfluid pressure switch, electromechanically actuated

INSTRUCTIONS. KP R9748 KP 61, 62, 63, 68, 69 vapor charge KP 71, 73, 75, 77, 79, 81 adsorption charge (cross ambient)

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

RT2Y Compact temperature switch intrinsic safety

Safety switches with separate actuator

26360, NAMUR. Technical data

Material pressure (bar) (Cv (US) kv x 1,2 Seat

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

Safety switches for hinged doors

Technical Data Measuring principle Bellow Repeatability ± 0.5 % FS typ.

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Electromechanical pressure switches

Classification Enclosure rating Input voltage Type of

series Subminiature snap-action switches

For hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T

Temperature Switches

Operating pressure (bar)

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

PSR DC/ESP4/2X1/1X2

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:

Fieldbus Independent I/O Modules 4 DO DC 24 V 0.5 A, High-Side Switching (/xxx-xxx)

Limit switches for Dial Thermometers and Pressure gauges

XB4BS542 red Ø40 Emergency switching off pushbutton Ø22 latching turn release 1NC

SERIES SUBMINIATURE SNAP-ACTION SWITCHES

11 PROFIBUS Fieldbus Connector

Fieldbus Independent I/O Modules 2 DI DC 24 V 3.0 ms, High-Side Switching (/xxx-xxx) Manual

Devices raised mounting

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

OsiSwitch Limit Switches Innovation through modularity

Safety switches with separate actuator

series Miniature snap-action switches

ETD-BL-1T-OFF-CC- 10S

PHOENIX CONTACT Features

XCKS131 limit switch XCKS - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

Surface-mounting Thermostats AM Series with 1 or 2 single-pole snap-action switches IP40 protection

Safety switches with separate actuator

InReg Volume flow controller Pa

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

Disconnect Switches. Safe Switching and Disconnecting

Safety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

XCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

XCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

Safety switches with manual mechanical delay and separate actuator

InCos-P Pressure sensor 20 Pa Pa

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

Safety relay emergency stop/protective door, 230VAC, 3 enabling paths

Safety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths

XCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11

RT2E Compact temperature switch Explosion proof

Solid State Remote Power Controller E /627

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

KINAX WT720 absolute, programmable angular postion transmitter

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

XCKM102 limit switch XCKM - steel roller plunger - 1NC +1NO - snap action - Pg11

InBin-P Pressure switches from 5 Pa Pa

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

XCKD3918P16EX limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

Ultra Slim Relays 24

SUBMINIATURE MICROSWITCHES - SEALED

52 x 72 x 30 (2.05 x 2.83 x 1.18) N/C + N/O; N/C + N/C N/C + N/O N/C + N/O; N/C + N/C

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description.

Electromechanical pressure switches

Microswitches MS Series

Contact Dial Thermometers

Electrical actuator AME 855

Product type designation. Control elements. Installation type/mounting

QUINT-PS/ 1AC/24DC/20/CO

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface

ZB5FG09 flush mounted selector switch head key pos stay put

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

Operator panels Advanced HMI Panel-based Mobile Panels

Fieldbus Independent I/O Modules 24 V DC Power Supply/Fuse/Diagn Manual

Threaded resistance thermometer Miniature design Model TR10-D

Pressure reducing valve. Pressure reducing valve in straightway form NPS 1-6 ARI-PREDU - ANSI

Linear Luminaire with LED Series 6012/5

LS 5000 series Vibration Level Switch for liquids

Technical data sheets

Position Switches Series 8070

Transcription:

Data sheet switch, Differential switch RT An RT switch contains a operated single-pole changeover contact, the position of which depends on the in the inlet connection and the set scale value. The RT series includes switches for general applications within industrial and marine refrigeration. The RT series also includes differential switches, switches for neutral zone regulation, and special switches with gold-plated contact surfaces for PLC applications. Features Versions with enclosure IP66 Wide regulating range Wide range of units for industrial and marine applications Suitable for alternating and direct current (AC and DC) Interchangeable contact system Special versions for PLC applications Safety Integrity Level: SIL 2 according to IEC 6508 DKRCC.PD.CB0.G5.02 520H2284

Approvals RT RT A RT AL RT 5A RT 6W, RT 6B, RT 6S RT 6AW, RT 6AB, RT 6AS RT 30AW, RT 30AB, RT 30AS RT 36B, RT 36S RT 7 RT 7L RT 200 RT 200L RT 260A RT 262A Germanischer Lloyd, GL Det Norske Veritas, DNV Bureau Veritas, BV Registro Italiano Navale, RINA Russian Maritime Register of Shipping, RMRS Nippon Kaiji Kyokai, NKK Korean Register of Shipping, KRS CE marked according to 60947-4, -5 CE marked acc. to PED 97/23/EC category IV, safety equipment and EN 2263 China Compulsory Certificate, CCC Technical data Cable connection Enclosure Ambient temperature Switches 2 Pg 3.5 Cable diameter 6 4 mm IP66 to EN 60529 / IEC 529, except for versions with ext. reset which are IP54-50 70 C for control housing See Ordering, switches (below) Solid / stranded 0.2 2.5 mm 2 Flexible, without ferrules 0.2 2.5 mm 2 Flexible, with ferrules 0.2.5 mm 2 Tightening torque Rated impulse voltage max..5 Nm 4 kv Pollution degree 3 Short circuit protection, fuse Insulation 0 Amp 400 V DKRCC.PD.CB0.G5.02 520H2284 2

Materials in contact with the medium Bellows Material W. no. To EN Comments RT 260AL, RT 262AL, RT 263AL, RT 265A, RT 5A, RT 5AL, RT 260A RT RT 200, RT 200L RT 6B, RT 6S, RT 6W, RT 6AB, RT 6AS, RT 6AW RT A, RT AL RT 262A RT 7, RT 7L RT 36B, RT 36S, RT 30AW, RT 30AB, RT 30AS 07-7253 Steel.0338 039 Nickel-plated 07-7254 Steel.040 0277-2 Nickel-plated 07-7258 Stainless Steel.4306 0088-2 07-7260 07-7252 07-7274 07-7253 07-7258 07-7269 07-7270 Aluminium ) 3.0255 573-3 Steel ).0402 0250-2 Zn-plated 07-7256 Steel.0338 039 Nickel-plated, Tin-plated Steel.078 0227-3 Nickel-plated Stainless Steel.4306 0088-2 Steel Spring wire type DH 0270- Zn-plated 07-7275 Stainless Steel.4306 0088-2 Stainless Steel.4568 0270-3 Brass 2.032 652 Brass 2.0402 265 07-728 Steel.0332 0 Nickel-plated 07-7282 Steel.0338 039 Nickel-plated 07-7283 Steel.078 0227-3 Nickel-plated Stainless Steel.4306 0088-2 Aluminium ) 3.0255 573-3 Steel ).0402 0250-2 Zn-plated 07-7255 Steel.0338 039 Nickel-plated, Tin-plated 07-7259 Steel.040 0277-2 Nickel-plated Stainless Steel.4306 0088-2 Steel Spring wire type DH 0270- Zn-plated Aluminium ) 3.0255 573-3 Steel ).0402 0250-2 Zn-plated 07-7254 Steel.0338 039 Nickel-plated 07-7268 Steel.040 0277-2 Nickel-plated 07-7288 Stainless Steel.4305 0088-3 Stainless Steel.4306 0088-2 Aluminium ) 3.0255 573-3 Steel ).0402 0250-2 Zn-plated 07-7279 Stainless Steel.4306 0088-2 Stainless Steel.4568 0270-3 Brass 2.032 652 Brass 2.040 264 Brass 2.0402 265 07-7284 Steel.0332 0 Nickel-plated 07-7286 Steel.0338 039 Nickel-plated 07-7283 Steel.078 0227-3 Nickel-plated 07-7286 Stainless Steel.4305 0088-3 Stainless Steel.4306 0088-2 Stainless Steel.4568 0270-3 ) Only in types with connection G 3/8 A + weld nipple ø 6.5/0 mm DKRCC.PD.CB0.G5.02 520H2284 3

Ordering For R22, R34a, R404A, R407A, R407C, R407F, R422B, R422D For complete list of approved refrigerants, visit www.products.danfoss.com and search for individual code numbers, where refrigerants are listed as part of technical data. Regulation range Differential p Reset working test [bar] [bar] [bar] [bar] Pe ¼ in flare Code no. G 3/8 A ) -0.8 5 0.5.6 Auto. 22 25 07-524566 RT Low -0.8 5 0.5 Man. (Min.) 22 25 07-524666 RT 200 0.2 6 0.25.2 Auto 22 25 07-523766 High RT 7 0 30 4 Auto 42 47 07-529566 ) BSP ext. thread, ISO 228-. Safety switches for R22, R34a, R404A, R407A, R407C, R407F, R422B, R422D, R507A, R77 *) For complete list of approved refrigerants, visit www.products.danfoss.com and search for individual code numbers, where refrigerants are listed as part of technical data. Low High RT A RT 5A ) BSP ext. thread, ISO 228-. *) Only for RT A, RT 5A. Regulation range Differential p Reset working test P e [bar] [bar] [bar] [bar] Cutting ring ø6 mm Code no. G 3/8 A ) + weld nipple ø6.5/0 mm -0.8 5 0.5.6 Auto 22 25 07-50966 07-50066 -0.8 5 0.5 Man. (Min.) 22 25 07-502766 07-500266 -0.8 5.3 2.4 Auto 22 25 07-500766 4 7.2 4 Auto 22 25 07-505266 07-504666 4 7.3 Man. () 22 25 07-50666 07-504766 Safety switches with EN 2263 approval and CE marked acc. PED ( Equipment Directive) *) R22, R34a, R404A, R407A, R407C, R407F, R422B, R422D, R507A, R77 **) For complete list of approved refrigerants, visit www.products.danfoss.com and search for individual code numbers, where refrigerants are listed as part of technical data. High High High Regulation range Differential (fixed) Δp Reset working test P e [bar] [bar] [bar] [bar] [bar] ¼ in flare Cutting ring ø6 mm Code no. G 3/8 A ) + weld nipple ø6.5/0 mm G ½ A ) RT 6W 5 25 3.0 Auto 34 3 ) 38 07-50366 RT 6B 0 28.0 4 ) Man. () 34 3 ) 38 07-503466 RT 6S 0 28.0 4 ) Man. () 34 3 ) 38 07-507566 RT 30AW 2 ) 0 0.8 Auto 22 25 07-58766 RT 30AB 2 ) 0 0.6 4 ) Man. () 22 25 07-58866 RT 30AS 2 ) 0 0.4 4 ) Man. () 22 25 07-58966 RT 6AW 5 25 3.0 Auto 34 3 ) 38 07-5366 07-503266 RT 6AB 0 28.5 4 ) Man. () 34 3 ) 38 07-53366 07-503566 RT 6AS 0 28. 5 4 ) Man. () 34 3 ) 38 07-54666 07-507666 *) Meets the requirements in VBG 20 on safety equipment and excess s. W=Wächter ( control). B= Begrenzer ( control with external reset). S= Sicherheitsdruckbegrenzer ( control with internal reset). A rupture in the bellows system of the unit will cause the compressor to stop. **) Only for RT 6AW, RT 6AB, RT 6AS, RT 30AW, RT 30AB, RT 30AS. ) BSP ext. thread, ISO 228-. 2 ) Approved for PED also acc. to EN2953-9 and EN2922-. 3 ) working acc. to PED is limited to 28 bar. 4 ) DKRCC.PD.CB0.G5.02 520H2284 4

Ordering (continued) switches with adjustable neutral zone for R22, R34a, R404A, R407A, R407C, R407F, R507A, R77 *) For complete list of approved refrigerants, visit www.products.danfoss.com and search for individual code numbers, where refrigerants are listed as part of technical data. Low High ) BSP ext. thread, ISO 228-. *) Only for RT AL, RT 5AL. Regulation range Differential p Adjustable neutral zone NZ p working 2 ) Without nipple. test P e [bar] [bar] [bar] [bar] [bar] Cutting ring ø6 mm Code no. G 3/8 A ) + weld nipple ø6.5/0 mm RT AL -0.8 5 0.2 0.2 0.9 22 25 07L00666 07L003366 RT 200L 0.2 6 0.25 0.25 0.7 22 25 07L003266 2 ) RT 5AL 4 7 0.35 0.35.4 22 25 07L00766 2 ) 07L004066 RT 7L 0 30.0 3.0 42 47 07L004266 2 ) Differential switches for R22, R34a, R404A, R407A, R407C, R407F, R422B, R422D, R507A, R77 For complete list of approved refrigerants, visit www.products.danfoss.com and search for individual code numbers, where refrigerants are listed as part of technical data. ) BSP ext thread, ISO 228-. 2 ) Man. () reset. Regulation range Differential p Operating range for LP bellows working test P e [bar] [bar] [bar] [bar] [bar] Cutting ring ø6 mm Code no. 3 ) Filter monitor: Alarm p = 0.8 bar, cut-out p = bar (factory setting). 4 ) With 3 m capillary tube. G 3/8 A ) + weld nipple ø6.5/0 mm 0.5 4 0.3-8 22 25 07D00466 07D00266 RT 260A 0.5 4 0.3-8 22 25 07D002266 2 ) 0.5 6 0.5-36 42 47 07D00566 4 ) 07D002366.5 0.5-3 42 47 07D00666 07D002466 RT 262A 0..5 0. - 9 3 07D00366 07D002566 RT 265A 3) 6 0.5-36 42 47 07D007266 Differential switches with adjustable neutral zone for R22, R34a, R404A, R407A, R407C, R407F, R422B, R422D, R507A, R77 For complete list of approved refrigerants, visit www.products.danfoss.com and search for individual code numbers, where refrigerants are listed as part of technical data. Adjustable Code no. Operating Regulation Differential neutral zone working test range for range p NZ LP bellows G 3/8 A ) P e + weld nipple [bar] [bar] [bar] [bar] [bar] [bar] ø6.5/0 mm RT 262 AL 0..5 0. 0. 0.33-9 3 07D004366 ) BSP ext thread, ISO 228-. DKRCC.PD.CB0.G5.02 520H2284 5

Ordering (continued) Switches ) Contact system versions Contact system Description Contact load Code no. With automatic reset SPDT Single-pole changeover switch with terminal board proof against leakage current. Fitted in all standard versions of type RT. Snap action changeover contacts. Alternating current 2 ) 07-403066 With manual (max.) reset With manual (min.) reset SPDT For manual reset of unit after contact changeover on rising. For HP units prepared for reset facility. For manual reset of unit after contact changeover on falling. For LP-units prepared for reset facility. Ohmic: AC = 0 A, 400 V Inductive: AC 3 = 4 A, 400 V AC 5 = 3 A, 400 V Direct current DC 3 = 2 W, 220 V 07-404266 07-40466 SPDT With automatic reset, goldplated SPDT Single-pole changeover switch with gold plated (oxide-free) contact surfaces. Increases cut-in reliability on alarm and monitoring systems, etc. Snap action changeover contacts. Terminal board proof against leakage current. Alternating current 2 ) Ohmic: AC = 0 A, 400 V Inductive: AC 3 = 2 A, 400 V AC 5 = A, 400 V Direct current DC 3 = 2 W, 220 V 07-424066 Alternating current 2 ) Cuts in two circuits simultaneously ST Single-pole changeover switch that cuts in two circuits simultaneously on rising. Snap action changeover contacts. Terminal board proof against leakage current. Ohmic: AC = 0 A, 400 V Inductive: AC 3 = 3 A, 400 V AC 5 = 2 A, 400 V Direct current DC 3 = 2 W, 220 V 3 ) 07-403466 With nonsnap action changeover contacts Single-pole changeover switch with non-snap action changeover contacts. Alternating or direct current 25 VA, 24 V 07-0866 SPDT ) RT switches meet the conditions of EN 60947-2-9. 2 ) starting current (L.R.) = 7 AC 3. 3 ) If current is led through the contacts 2 and 4, i.e. terminals 2 and 4 connected but not terminal, the max. permissible load is increased by 90 W, 220V. The switches are shown in the position they assume on falling, i.e. after downward movement of the RT main spindle. The setting pointer of the switch shows the scale value at which contact changeover occurs on falling. An exception is RT with switch code no. 07-404266 with Man. reset, where the setting pointer shows the scale value at which contact changeover occurs on rising. Special versions RT can be supplied with special switches as follows. When ordering, please state:. 2. Code no. of standard unit 3. Code no. of special switch DKRCC.PD.CB0.G5.02 520H2284 6

Design / Function switch, type RT switch, type RT 5. Setting knob 9. Regulation range scale 0. Loop terminal. Pg 3.5 screwed cable entry 2. Main spring 4. Terminals 5. Main spindle 6. Switch 7. Guide bush 8. Contact arm 9. Differential setting nut 23. Bellows element 25. Fixing hole 27. 38. Earth terminal 39. Blow-out disc 44. setting spindle The bellows in the RT switch is connected to the low or high side of the controlled system via the connection. By turning the setting knob (5) the main spring (2) can be set to balance the in the bellows. A rise in compresses the bellows and moves the main spindle (5) upwards until spring and bellows are in equilibrium. The main spindle (5) is fitted with a guide bush (7) and a differential setting nut (9) that together transfer the main spindle movement to the switch (6). The RT 6W, RT 6B, RT 6S, RT 6AW, RT 6AB, RT 6AS, RT 30AW, RT 30AB, RT 30AS, RT 36B, RT 36S are equipped with a double bellows (an outer bellows and a regulating bellows). These units have been tested and approved by TÜV (Technischer Überwachungs Verein, Germany) according to EN 2263. General for EN 2263 approved units.. The units are equipped with a double bellows system. When in the plant exceeds the set value, the unit will automatically stop the plant. The double bellows system prevents loss of system charge in the event of bellows rupture. 2. Versions with designation W or AW cut again automatically when the has fallen to the set value minus the differential. 3. Versions with designation B or AB are cut manually with the external reset button. This is possible when the has fallen to the set value minus differential. 4. Versions with designation S or AS can be cut in manually with the internal reset arm when the has fallen to the set value minus differential. As laid down by EN 2263 requirements, if a rupture occurs in the regulating bellows of the unit, the refrigerating system compressor will be stopped and can only be restarted when the control has been replaced. A rupture in the outer bellows will cause the cut-out of RT 36 to fall 2.5 bar, and the cut-out of RT 6 and RT 30 to fall 4.5 bar under the set value. This means that the unit cuts out at normal condensing and thus provides a fail-safe function. All RT switches, including those which are EN 2263 approved, operate independently of changes in the ambient temperature around the control housing. Therefore the set cut-out and differential are held constant provided the permissible ambient temperatures are not exceeded. DKRCC.PD.CB0.G5.02 520H2284 7

Design / Function (continued) switch with adjustable neutral zone, type RT L switch, type RT L 5. Setting knob 9. Regulation range scale. Pg 3.5 screwed cable entry 2. Main spring 5. Main spindle 6. Switch 7. Upper guide bush 8. 8a, 8b. Contact arm 20. Lower guide bush 23. Bellows element 25. Fixing hole 27. 38. Earth terminal 39. Blow-out disc 40. Neutral zone setting nut 44. setting spindle RT L switches are fitted with a switch with an adjustable neutral zone. This enables the units to be used for floating control. The neutral zone switch contact arms (8a) and (8b) are operated by the spindle guide bushes (7) and (20). The upper guide bush (7) is fixed while the lower guide bush (20) can be moved up or down by the setting nut (40). In this way the neutral zone can be varied between a minimum value (equal to the mechanical differential of the unit) and a maximum value (depending on the type of RT unit). [bar] Neutral zone Diff. Mechanical differential ~NZ min. Diff. Set time [s] DKRCC.PD.CB0.G5.02 520H2284 8

Design / Function (continued) Differential switch, type RT Differential switch, type RT MK FW 3. LP connection 4. LP bellows element 5. Setting disc 9. Regulation range scale 0. Coil clamp. Pg 3.5 screwed cable entry 2. Main spring 4. Terminals 5. Main spindle 6. Switch 7. Upper guide bush 8. Contact arm 20. Lower guide bush 24. HP bellows element 25. Fixing hole 34. HP connection 38. Earth terminal 39. Blow-out disc An RT differential switch contains a single-pole changeover switch that makes or breaks depending on the differential between two counteracting bellows elements (LP and HP). Differential switches are used primarily as protection against too low a differential across liquid circulation pumps. A secondary application is the safeguarding of lubricating oil in refrigeration compressors. The function of the switch is conditional only on the differential, i.e. the difference in between the two counteracting bellows, whereas it is independent of the absolute on both bellows. The bellows (4) and (24) are respectively connected to the LP port (lowest ) and the HP port (highest ). The main spring (2) can be set for different differential s by the setting disc (5). If the differential between highest and lowest s falls, the spindle (5) moves downwards and via the upper guide bush (7), actuates the switch contact arm (8). The reverse function occurs if the differential rises. DKRCC.PD.CB0.G5.02 520H2284 9

Terminology Floating control A form of delayed control where the correcting element (e.g. valve, damper, or similar) moves towards one extreme position at a rate independent of the magnitude of the error when the error exceeds a definite positive value, and towards the opposite extreme position when the error exceeds a definite negative value. Hunting Periodic variations of the controlled variable from the fixed reference. Neutral zone The interval between the make points of the two contacts. Snap function A certain contact force is maintained until the irrevocable snap is initiated. The time during which the contact force approaches zero is thus limited to a very few milliseconds. Therefore contact bounce cannot occur as a result of, for example, slight vibrations, before the cut-out point. Contact systems with Snap function will change over even when micro-welds are created between the contacts during cut-in. A very high force is created during cut-out to separate the contacts. This force immediately shears off all the welds. Thus the cut-out point of the unit remains very accurate and completely independent of the magnitude of the current load. Setting RT with automatic reset LP The knob is used to set the lowest at which the contact system must be activated (cut-out or cut-in). This value can be read on the main scale of the unit. The differential roller must be used to set the differential. Highest activating = lowest activating + set differential. RT with manual reset LP RT switches RT and RT A are obtainable in versions with min. reset. When the falls to the setting value the control cuts out. Manual reset becomes possible when the in the bellows system has risen to a value corresponding to the set value + the differential. On falling the follower activates the contact system arm and the contact changes over. The scale is calibrated so that the scale value corresponds to contact changeover on falling. RT with automatic reset HP The knob can be used to set the lowest at which the contact system must be activated (cut-out or cut-in). This value can be read on the main scale of the unit. The differential must be set with the differential roller. Highest activating = lowest activating + set differential. RT with manual reset HP switch RT 5A is obtainable with max. reset. When the has risen to the set value the control cuts out. Manual reset only becomes possible when the has fallen to a value corresponding to the set minus the differential. The differential roller is then used as a follower. On rising the differential roller activates the contact system arm and the contact changes over. The scale is calibrated so that the scale values correspond to contact changeover on rising, which is opposite to RT units with automatic reset. DKRCC.PD.CB0.G5.02 520H2284 0

Dimensions [mm] and weight [kg] RT switch housing RT RT A, RT AL RT A, RT AL RT 6A RT 6, RT 36 RT 30A RT 7, RT 7L, RT 200, RT 200L RT 260A RT 262A RT 260A, RT 262A Net weight approx. kg DKRCC.PD.CB0.G5.02 520H2284