Installation manual Digital Energy USB / RS232 / Relay Interface Card for use with GE Digital Energy VH Series UPS VA

Similar documents
USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

Grundfos MAGNA, GENI Module

PCLD-8751 PCLD User Manual

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

UTAH-100/XHDA SERIES

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2

PCLD-8751/8761/ Channel Isolated D/I and Relay Board. User Manual

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting

Operating Manual. DMX Relay Card 3002R

I/O SIGNAL CONDITIONER

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

AMAX-2750SY Series. 32-ch AMONet RS-485 Isolated Digital I/O Slave Modules. User Manual

MIC-3001/8. 3U/4U CompactPCI Enclosure for Rack Mounting. User Manual

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual

The accessory described in this manual is a high quality product that has been carefully designed and manufactured to guarantee optimal performance.

5504 Thermocouple Analog Input Module

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

ADAM-5511 Quick Start

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

OPERATING INSTRUCTIONS. Programmable relay card

SMVector Additional I/O Module Installation and Operation Manual

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

Temperature & Humidity Datalogger

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

INSTALLATION INSTRUCTIONS 07/2018

User's Guide. Model High Precision Quad Output DC Power Supply

POCKET MULTIMETER Model No: MM18

SOLARIMMERSION IV Advanced Installation Manual v1.9

CA-A480-A Elevator Controller. Reference & Installation Manual

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

SATA II HDD Canister KISS DA 435 Quick Reference Guide

MINI 4200 Model # - C Mini Instruction Manual V.2. This instruction manual serves as a guide for the Mini 4200.

PSA200 User s Manual

Electronic Temperature Controller. Instruction Manual Version

Resolver to Digital Expansion Board

5521 Potentiometer Analog Input Module

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

user s manual Battery case model #: IPB3500S Battery Case Charger for iphone 6

PRODUCT SPECIFICATION. PC Board Relays. Series.

D Issue D Original. Instruction Manual. Micro Tool Interface

User s Guide. 600A AC Clamp Meter. Model 38387

MT8050iE series. Installation Instruction (1) (2)

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

User Manual EKI-6528TI/ 6528TPI. EN port M12 Unmanaged/ PoE Switch with Wide Temperature

User Guide. Control Box. RoscoLED TM.

Power Quality Recorder

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

LXM32. Explanation for detected error E 733F. Expert Support Machine Solution

Operating Manual -ENGLISH- Page 1 KWG-ISO

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

HI ma Simulator

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

PCM PC/ bit Digital I/O Module. User Manual

Installation Instructions

RoscoLED Tape VariWhite Gaffer Kit

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Broadband Automatic Disconnect Switch. User Manual

Table of Contents 1. Safety Precautions and Warnings General Information Hardware Overview Tool Description Specif

UVAX Protocol Node NT Teslights Hybrid Lighting Controls B-PLC Solution. Technical Manual, T0115 January 2015

INSTALLATION, OPERATION AND CONFIGURATION MANUAL September/2016 VRP10-O PROFIBUS-PA OPTICAL REPEATER

FA-2448 SIX POSITION Filter Wheel

CONTROL SYSTEM FOR EMS USER MANUAL

AI Light Bar Part # Feniex AI Instruction Manual / feniex.com

3.5 TFT LCD CCTV Service Viewer with Wristband LCD35SV

Elapsed Timer Control Panel

LCI User Manual mantracourt.com

Chore-Tronics Mobile Server

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

EDG Port Industrial 10/100 Mbps Ethernet Switch. User Manual

Operating Manual RISH DPM Hz

OPERATION MANUAL SMARTLAB USB 8 CHANNELS RELAY OUTPUT 8 CHANNELS PHOTO ISOLATOR INPUT BOARD

OPERATING MANUAL. DMX Multiplexer 3112A-H Mk3

USB Channel Isolated Digital I/O USB Module. User Manual

SMVector Additional I/O Module Installation and Operation Manual

Relay Board. User Manual. 1.0, Oct 2013

Installation Instructions

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Controller Smart Box Translation of operating and installation instructions

MPP200 User s Manual

Serial PROFIBUS Interface

Operating Instructions VEGAMET 381

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

User's Guide. Phase Sequence and Motor Rotation Tester Model

User Manual IDS-3206 Series. 6.5" Industrial Panel Mount Monitor

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content

Transcription:

GE Consumer & Industrial Installation manual Digital Energy USB / RS232 / Relay Interface Card for use with GE Digital Energy VH Series UPS 700-3000 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 51 44 www.gedigitalenergy.com

Installation manual Digital Energy USB / RS232 / Relay Interface Card for use with GE Digital Energy VH Series UPS 700-3000 VA Please read these instructions carefully before installation of the interface card. Keep this manual in a safe place for future reference. Contents 1 Important safety instructions...2 1.1 Save these instructions 1.2 Safety rules 2 Introduction...3 2.1 Introduction 2.2 Intended use 2.3 Warranty 3 Installation...3 3.1 Package contents 3.2 Installation procedure 4 Specifications...6 General Electric Consumer & Industrial SA. All rights reserved; reproduction without permission prohibited. The content of this manual may be subject to change without prior notice; no liability can be accepted for any error or omission. The illustrations and plans describing the equipment are intended as general reference only and are not necessarily complete in every detail. OPM_CON_ACC_REL_VHX_XGB_V010 1 Installation manual USB/RS232/Relay card VH Series 1.0 (GB)

1 - Important safety instructions 1.1 Save these instructions This manual contains all necessary information about the correct installation of the USB/RS232/Relay Card into the Digital Energy VH Series UPS. Before attempting to install or operate the equipment, carefully read this manual. Full understanding of and compliance with the safety instructions and warnings contained in this manual are the ONLY CONDITIONS to avoid any dangerous situation during installation, operation and maintenance work, and to preserve the maximum reliability of the UPS system. GE refuses any responsibility in case of non-observance, unauthorized alterations or improper use of the delivered UPS. While every care has been taken to ensure the completeness and accuracy of this manual, GE accepts no responsibility or liability for any loss or damage resulting from the use of the information contained in this document. This document shall not be copied nor reproduced without the permission of GE. Due to technical improvements, some of the information contained in this manual may be changed without notice. 1.2 Safety rules CAUTION There may be damage to the equipment if procedures and practices are not strictly observed and followed. NOTE The installation and cabling of the option USB/RS232/Relay Card must be performed by a qualified service person*. Please refer to the Safety Rules included in the Operating Manual of the UPS. If any problems are encountered with the description of this installation guide, please contact the nearest Service Centre before proceeding. For the installation and cabling of the card in USA use only type DP (DP1, DP1-P or DP2, DP2-P) or equivalent cable. * Qualified, skilled personnel are persons who (because of their training, experience, and position as well as their knowledge of appropriate standards, regulations, health and safety requirements and working conditions) are authorised to be responsible for the safety of the equipment, at all times whilst carrying out their normal duties and are therefore aware of, and can report, possible hazards (observe IEC 364, DIN VDE 0105 and national wiring regulations and accident prevention rules). OPM_CON_ACC_REL_VHX_XGB_V010 2 Installation manual USB/RS232/Relay card VH Series 1.0 (GB)

2 - Introduction 2.1 Introduction The USB/RS232/Relay interface card enables advanced communication between the UPS and the computer (software required). The card is to be installed in the option slot of the Digital Energy VH Series UPS models. The card is provided with an USB connector, a 9-pole sub-d connector and four potential free changeover contacts, representing: mains failure, general alarm, battery low and bypass active. The identification number of the USB/RS232/Relay Card is 18802. 2.2 Intended use The USB/RS232/Relay interface card is to be installed in the option slot of the Digital Energy VH Series UPS models. The technical data can be found in this document and shall be strictly observed. 2.3 Warranty GE Consumer & Industrial SA, operating through its authorized agents, warrants that the standard products will be free of defects in materials and workmanship for a period of 36 months after the date of invoice, or such other period as may be specified. NOTE This warranty does not cover failures of the product which result from incorrect installation, misuse, alterations by persons other than authorized agents, or abnormal operating conditions. 3 - Installation 3.1 Package contents The USB/RS232/Relay Card kit contains the following items: - ESD-proof bag with USB/RS232/Relay Card (PCB IM0131A1, article ID# 18802) - plastic bag with two screws - USB cable - RS232 cable - this manual Inspect the card for damage after unpacking. If any damage is present please immediately notify the carrier and place of purchase. WARNING! In case of recognizable damage do not insert the card in the UPS OPM_CON_ACC_REL_VHX_XGB_V010 3 Installation manual USB/RS232/Relay card VH Series 1.0 (GB)

3.2 Installation procedure Be sure that you have read and fully understood Chapter 1 Important Safety Instructions. Step 1 Make all necessary connections NOTE The text NO and NC (normally open resp. normally closed) printed on the card reflects the cold situation, i.e. when the card comes out of the box. After installation, and during normal operation, pins 4-5 are open and 4-6 are closed. OPM_CON_ACC_REL_VHX_XGB_V010 4 Installation manual USB/RS232/Relay card VH Series 1.0 (GB)

Step 2 Switch off the UPS Step 3 Remove existing card Step 4 Insert new option card Step 5 Fix card and connect data cable(s) Step 6 Switch on the UPS NOTE: USB and RS232 cannot be used simultaneously. When both ports are used, USB will override the RS232 connection. OPM_CON_ACC_REL_VHX_XGB_V010 5 Installation manual USB/RS232/Relay card VH Series 1.0 (GB)

4 - Specifications Power Supply : 8-18V Max. input power : 2W all relays closed Signal inputs : on state 2.4V; 1.35mA min. Output : relay, screw terminal - Voltage rating : 60 Vdc or 42 Vac RMS - Current rating : 1.25 A max (50 VA max) Operating temp. : -10 ~ +40 C Storage temp. : max. 60 C OPM_CON_ACC_REL_VHX_XGB_V010 6 Installation manual USB/RS232/Relay card VH Series 1.0 (GB)