FR-IB100/PCIe. FlexRay PCI Express Interface Card USER MANUAL ENGLISH

Similar documents
USB-to-CAN V2. Compact Embedded Automotive Professional USER MANUAL ENGLISH

USB-to-CAN FD. Compact Embedded Automotive USER MANUAL ENGLISH

CANbridge NT. 200 and 420 USER MANUAL EN 1.3

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO USER MANUAL ENGLISH

USER MANUAL en-us ENGLISH

NT. 200 and 420 USER MANUAL EN 1.4

INpact Slave PCIe. Industrial Ethernet PCIexpress Interface USER MANUAL ENGLISH

INpact Slave PCIe. Profibus/PROFINET IRT Fiber Optic/CC-Link/DeviceNet USER MANUAL EN 1.5

HARDWARE MANUAL ENGLISH

INpact Slave PCIe. Industrial Ethernet PCIexpress Interface USER MANUAL ENGLISH

STARTUP GUIDE. SP en-us ENGLISH

FRC-EP170. Automotive Platform USER MANUAL en-us ENGLISH

Anybus X-gateway. PROFIBUS Master Interface NETWORK GUIDE SCM EN 1.0 ENGLISH

Kvaser PCIEcan 2xHS v2 User s Guide

INSTALLATION GUIDE en-us ENGLISH

Kvaser PCIEcan HS v2 User s Guide

Kvaser Mini PCI Express HS v2 User s Guide

Kvaser Mini PCI Express 2xHS v2 User s Guide

Kvaser PCIEcan 4xHS User s Guide

Kvaser Mini PCI Express User s Guide

Kvaser Leaf Light v2 User s Guide

Kvaser Mini PCI Express User s Guide

Kvaser Leaf Light v2 User s Guide

Kvaser USBcan Light User s Guide

Kvaser Mini PCI Express User s Guide

Anybus Communicator STARTUP GUIDE. IIoT. SP en-us ENGLISH

Anybus Communicator PROFINET

Kvaser Leaf Light v2 User s Guide

Blackwire C610 Blackwire C620

Anybus X-gateway EtherNet/IP

Anybus.NET. using TIA Portal with PROFIBUS APPLICATION NOTE

Anybus CompactCom Starter Kit REFERENCE GUIDE

REFERENCE GUIDE HMSI ENGLISH

User Reference Guide TACTIVO

Kvaser USBcan Light 4xHS User s Guide

Lotus DX. sit-stand workstation. assembly and operation instructions. MODEL # s: LOTUS-DX-BLK LOTUS-DX-WHT

MF RD700. PEGODA Contactless Smart Card Reader READER COMPONENTS. Preliminary Product Specification Revision 2.0 PUBLIC. July2002

User Reference Guide TACTIVO

User Reference Guide TACTIVO. for: ipad ipad mini ipad mini with Retina display ipad Air Guardian Case for Tactivo for ipad, ipad mini and ipad Air

Hardware Installation 1. Install two AA batteries in the mouse. Pairing Process in Vista and Windows XP SP2

Operation Manual for Cloud 3700F Version 0

4 Channel RFID reader LF 125KHz with CAN bus LT-LFS03 USER MANUAL

User Guide Microsoft Portable Power (DC-21)

Owner s Manual. 2-Port DB9 RS-232 Serial PCI Card

Wireless-N PCI Adapter User Manual

Hardware Manual ipc-i 320/PCI II Intelligent PC/CAN Interface

Owner s Manual. 4-Port RS-232 Serial PCIe Card with Breakout Cable

User manual Model: VIU-800 Brand:

& I CODE CL RD701. PEGODA Contactless Smart Card Reader READER COMPONENTS. Product Specification Revision 3.1 PUBLIC.

TF-3239DL 10/100Mbps PCI Network Adapter

Kvaser USBcan Light 4xHS User s Guide

Anybus X-gateway. PROFINET IRT (2.32) Interface NETWORK GUIDE

User Guide Nokia Wireless Charger DT-601

Logitech Alert 700i/750i System Requirements & Support Guide

Product: DrumBass Explore BT Bluetooth Speaker Model: FG-8030N User Guide Thank you for purchasing a Lifetrons DrumBass Explore BT Bluetooth Speaker.

User Reference Guide TACTIVO. for: ipad mini ipad mini with Retina display ipad Air. Guardian Case for Tactivo for ipad mini & Tactivo for ipad Air

Trademarks and registered trademarks are proprietary to their respective manufactures.

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

BBW200 SmartClim Bluetooth Smart Temperature and Humidity Sensor User Manual

ToolSmart Digital Moisture Meter

Owner s Manual. Industrial-Grade USB 3.0 Hub. Models: U IND (4-Port), U IND (7-Port), U IND (10-Port)

FZ-VEBG11x. Cradle. Model No. FZ-VEBG11 1. Model No. U Universal R China 1: Area U: Universal R: China

USER MANUAL. Model NAME : Anker USB 2.4G Wireless Vertical Mouse MODEL NO. : A VERSION : 0.1 DATE : A User Manual VER: 0.

II. Intelligent PC/CAN Interface USER MANUAL ENGLISH

W IRELESS8000 T. Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT

FIP IO Slave. X-gateway Interface Addendum. Doc: HMSI Rev: Connecting DevicesTM

Bluetooth Hands-Free Speaker Phone Custom Accessories 23685

USER GUIDE. Ultra-Slim Stow-N-Go TM ExpressCard Presenter

ipaq Networking 5 Port 10/100 Fast Ethernet Auto Sensing Switch

4 Port USB Power Hub. Model: JH-800 USER MANUAL

5/8 Port Gigabit Ethernet Switch

Easi-Speak Docking Station. Warranty & Support. Technical Support

IXXAT CME/PN. CANopen-PROFINET Gateway HARDWARE MANUAL ENGLISH

USER GUIDE. Element Wireless Smart Plug Model: E1C-NB6

To force your device to restart, press and hold the power button until your device vibrates.

Quick Start Guide. Cisco Compatible 10Gbase-LR SFP+ Transceiver with DDM, SMF, 1310 nm, 10 km, LC. Model: N286-10GLR-SLC PROTECT YOUR INVESTMENT!

OPERATING INSTRUCTIONS POWERSMART 10 10,000 MAH PORTABLE POWER PLEASE READ BEFORE OPERATING THIS EQUIPMENT

DVI KVM Switch user manual Model

16-SLOT IN-BAND MANAGEMENT CHASSIS

Manual. Network Expansion Port 2 NEP-2. English. Brands by Navico - Leader in Marine Electronics

SHINE 3000 WITH FASHION CABLE

NT 200/420. Communication in Gateway Setup SOFTWARE DESIGN GUIDE ENGLISH

Quick Start Guide. Dual USB Wall Charger with PD Charging, (x1) USB-A Port and (x1) USB-C Port. Model: U280-W02-A1C1

FlyTV MCE Installation Guide Animation Technologies Inc.

Weigl-EM +43 (0) Weigl-EM is the hardware manufacturer and European distributor

Kvaser Linx J1587 User's Guide

User Reference Guide TACTIVO

TD-8616 ADSL2/2+ Ethernet Modem

RocketPort Plus Hardware Installation

Owner s Manual. USB 3.1 Gen 1 USB-C to HDMI Adapter

Kvaser PCI104 User's Guide

RocketStor 5315 Quick Installation Guide V1.0 Jan. 4, 2013

Super Stack. (Little Stack Wireless + Big Stack)

P OCKET POWER 6000 T. Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT

Chapter 1 : FCC Radiation Norm...3. Chapter 2 : Package Contents...4. Chapter 3 : System Requirements...5. Chapter 4 : Hardware Description...

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

user s manual Battery case model #: IPB3500S Battery Case Charger for iphone 6

FRG-3105 Series Residential Gateway

Wa r n i n g-wa r n i n g-wa r n i n g

INSTALLATION GUIDE DM-20 English Version 1.10 EN DM20 V1.10A

Transcription:

FR-IB100/PCIe FlexRay PCI Express Interface Card USER MANUAL 4.01.0103.20000 2.0 ENGLISH

Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks of any inaccuracies or omissions. The data and illustrations found in this document are not binding. We, HMS Industrial Networks, reserve the right to modify our products in line with our policy of continuous product development. The information in this document is subject to change without notice and therefore should not be considered as a binding description of the range of functions (neither for future product versions). HMS Industrial Networks assumes no responsibility for any errors that may appear in this document. There are many applications of the described product. Those responsible for the use of this device must ensure that all the necessary steps have been taken to verify that the applications meet all performance and safety requirements including any applicable laws, regulations, codes, and standards. HMS Industrial Networks will under no circumstances assume liability or responsibility for any problems that may arise as a result from improper use or use that is not in accordance with the documented features of this product. The examples and illustrations in this document are included solely for illustrative purposes. Intellectual Property Rights HMS Industrial Networks has intellectual property rights relating to technology embodied in the product described in this document. These intellectual property rights may include patents and pending patent applications in the USA and other countries. Trademark Acknowledgements IXXAT is a registered trademark of HMS Industrial Networks. All other trademarks are the property of their respective holders. Copyright 2016 HMS Technology Center Ravensburg GmbH. All rights reserved. FR-IB100/PCIe FlexRay PCI Express Interface Card User Manual 4.01.0103.20000 2.0

Table of Contents Page 1 User Guide... 3 1.1 Document History...3 1.2 Conventions...3 2 Safety and Dangers... 4 2.1 Information on EMC...4 2.2 General Safety Instructions...4 3 Scope of Delivery... 4 4 Product Description... 5 5 Installation... 6 5.1 Installing the Software...6 5.2 Installing the Hardware...6 6 Connections... 7 6.1 FlexRay D-Sub 9 Connector...7 6.2 FlexRay Internal Connector...8 7 Operation... 9 7.1 FlexRay LED...9 7.2 CPU LED...9 8 Firmware Updates... 9 9 Technical Data... 10 10 Support/Return Hardware... 10 10.1 Support...10 10.2 Return Hardware...10 11 Disposal... 10 A Regulatory Compliance... 11 A.1 EMC Compliance (CE)... 11 A.2 FCC Compliance Statement... 11 A.3 Disposal and recycling...12

This page intentionally left blank

User Guide 3 (14) 1 User Guide Please read the manual carefully. Make sure you fully understand the manual before using the product. 1.1 Document History Version Date Description 2.0 December 2016 Revised and edited in new design 1.2 Conventions Instructions and results are structured as follows: instruction 1 instruction 2 result 1 result 2 Lists are structured as follows: item 1 item 2 Bold typeface indicates interactive parts such as connectors and switches on the hardware, or menus and buttons in a graphical user interface. This font is used to indicate program code and other kinds of data input/output such as configuration scripts. This is a cross-reference within this document: Conventions, p. 3 This is an external link (URL): www.hms-networks.com Safety advice is structured as follows: Cause of the hazard! Consequences of not taking remediate action. How to avoid the hazard. Safety signs and signalwords are used dependent on the level of the hazard. This is additional information which may facilitate installation and/or operation. This instruction must be followed to avoid a risk of reduced functionality and/or damage to the equipment, or to avoid a network security risk. Caution This instruction must be followed to avoid a risk of personal injury.

Safety and Dangers 4 (14) WARNING This instruction must be followed to avoid a risk of death or serious injury. 2 Safety and Dangers 2.1 Information on EMC Risk of interference to radio and television if used in office or home environment! Use exclusively included accessories. Make sure shield of interface is connected with device plug and plug on other side. Use exclusively shielded cables. 2.2 General Safety Instructions Protect product from moisture and humidity. Protect product from too high or too low temperature (see Technical Data, p. 10). Protect product from fire. Don t throw, drop or try to bend the product. Don t paint the product. Don t modify or disassemble the product. Service must be carried out by HMS Industrial Networks. Don t use modified products. Store products in dry and dust-free place. 3 Scope of Delivery Included in the scope of delivery of standard variant: FR-IB100/PCIe CD with VCI driver VCI Driver Installation Guide FR-IB100/PCIe User Manual

Product Description 5 (14) 4 Product Description The FlexRay PCI Express interface card FR-IB100/PCIe is an interface for operation, analysis, diagnostics and stimulation of FlexRay networks. Features operation, measuring and analysis platform for FlexRay networks single lane (x1) PCI express card PCI connection in accordance with PCI express base specification, revision 1.1 (PCI express 1.1) FlexRay protocol support via communication controller Freescale MFR4310 FlexRay 2 x 10 MBit/s FlexRay bus connection via Physical-Layer-Chip NXP TJA1082 galvanically isolated highly integrated FPGA with PCIe controller, internal processor system, dual port memory, time stamp, asynchronous receiver open FlexRay PC driver interface (VCI) for Windows XP, Windows Vista, Windows 7 FlexRay transceiver TJA1082 FlexRay transceiver TJA1082 Isolation FlexRay controller MFR4310 FPGA FlexRay internal connector RAM Fig. 1 Block diagram with all main interfaces

Installation 6 (14) 5 Installation 5.1 Installing the Software For the operation of the interface a driver is needed. Windows Install VCI driver (see Installation manual VCI). version VCI 2 or version VCI 3 with VCI V2.20 Wrapper 5.2 Installing the Hardware Risk of ESD damages caused by improper handling! Use ESD protective measures to avoid equipment damage. The FR-IB100/PCIe can be operated in all PCI express slots (x1, x4, x8, x16). Make sure VCI driver V2 or V3 with V2.20 Wrapper is installed. Turn off computer. Pull power cord. Open computer case according to instructions of computer manufacturer. Determine suitable slot. Plug PCI/PCIe connector in corresponding slot, without using force. Make sure the interface is securely fitted in computer. Close computer case. Hardware installation is complete.

Connections 7 (14) 6 Connections 2 1 Fig. 2 Connectors 1 FlexRay D-Sub 9 connector (male) 2 Internal FlexRay connector (serial-ata form factor), optional On the FlexRay connectors the differential signal pairs (BM and BP) of the FlexRay bus channels A and B are available. The FlexRay bus is galvanically isolated from the PC ground and the PCI Express bus. Channels A and B are connected to the same potential. 6.1 FlexRay D-Sub 9 Connector Pin Allocation of D-Sub 9 Connector Pin no. Signal 1-2 FlexRay channel A Bus Minus (BM) 3 Ground (FlexRay) 4 FlexRay channel B Bus Minus (BM) 5-6 - 7 FlexRay channel A Bus Plus (BP) 8 FlexRay channel B Bus Plus (BP) 9 -

Connections 8 (14) 6.2 FlexRay Internal Connector Pin Allocation of Internal Connector Pin no. Signal 1 Ground (FlexRay) 2 FlexRay channel A Bus Plus (BP) 3 FlexRay channel A Bus Minus (BM) 4 Ground (FlexRay) 5 FlexRay channel B Bus Minus (BM) 6 FlexRay channel B Bus Plus (BP) 7 Ground (FlexRay)

Operation 9 (14) 7 Operation 1 2 Fig. 3 LEDs 1 FlexRay LED 2 CPU LED 7.1 FlexRay LED The FlexRay LED displays the device status. LED state Off Red flashing (constant frequency) Red and green flashing Green flashing (constant frequency) Red Green Description Boot manager or application not running (error) FlexRay communication controller not configured (boot manager or application running) Flash loader running, firmware is updated FlexRay communication controller is configured. FleyRay communication controller: no normal active operation FlexRay communication controller: normal active operation 7.2 CPU LED The CPU LED displays the communication status. LED state Off Green flashing (constant frequecy) Description Application not running Application running 8 Firmware Updates The FR-IB100/PCIe card is always supplied with the latest firmware on the onboard flash. The VCI cooperates with this firmware. If different firmware or update of onboard firmware is necessary, download necessary files and tools from www.ixxat.com. The operation of the flash loader is indicated by the FlexRay LED. Do not switch off the PC while the flash loader is running. Switching off the PC during operation of the flash loader may destroy the card.

Technical Data 10 (14) 9 Technical Data PCI Express interface PCI express single lane port (x1) in accordance with PCI Express base specification, revision 1.1 FlexRay communication controller Freescale MFR4310 FlexRay transceiver NXP TJA1082 Card system FPGA with Softcore processor 1 MByte RAM Dimensions 106 x 58 mm Weight Approx. 100 g Operating temperature range 0 C to +70 C Storage temperature range -40 C to +85 C Galvanic isolation 500 V AC for 1 minute between FlexRay bus and internal logic Relative humidity 0 % to 90 %, no condensation Power supply Via PCIe slot (3.3 V) Power consumption Typ. 400 ma (3.3 V) 10 Support/Return Hardware Observe the following information in the support area on www.ixxat.com: information about products FAQ lists installation notes updated product versions updates 10.1 Support For problems or support with the product request support at www.ixxat.com/support. If required use support phone contacts on www.ixxat.com. 10.2 Return Hardware Fill in the form for warranty claims and repair on www.ixxat.com. Print out the Product Return Number (PRN resp. RMA). Pack product in a physically- and ESD-safe way, use original packaging if possible. Enclose PRN number. Observe further notes on www.ixxat.com. Return hardware. 11 Disposal Dispose of product according to national laws and regulations. Observe further notes about disposal of products on www.ixxat.com.

Appendix A: Regulatory Compliance 11 (14) A Regulatory Compliance A.1 EMC Compliance (CE) The product is in compliance with the Electromagnetic Compatibility Directive. More information and the Declaration of Conformity is found at www.ixxat.com. A.2 FCC Compliance Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. Product name Responsible party FR-IB100/PCIe HMS Industrial Networks Inc Address 35 E. Wacker Dr, Suite 1700 Chicago, IL 60601 Phone +1 312 829 0601 Any changes or modifications not expressly approved by HMS Industrial Networks could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help.

Appendix A: Regulatory Compliance 12 (14) A.3 Disposal and recycling You must dispose of this product properly according to local laws and regulations. Because this product contains electronic components, it must be disposed of separately from household waste. When this product reaches its end of life, contact local authorities to learn about disposal and recycling options, or simply drop it off at your local HMS office or return it to HMS. For more information, see www.hms-networks.com.

This page intentionally left blank

last page HMS Industrial Networks AB Box 4126 300 04 Halmstad, Sweden info@hms.se 2016 HMS Technology Center Ravensburg GmbH 4.01.0103.20000 2.0.2693 / 2016-12-08 09:55