Metropolis ADM MultiService Mux Compact Shelf

Similar documents
Cisco ONS CL Shelf Assembly Hardware

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

Cisco ONS MA Shelf Assembly Hardware

Traverse System Documentation. Installation and Commissioning Guide

FSM-510G Series Ethernet Management Switch Quick Start Guide

INDUSTRIAL POE SWITCH

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

Connecting and Routing the Cables and Wires

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

8~14-Port Managed Ethernet Switch

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

AN B Optical Line Terminal Equipment. Hardware Description. Version A. Code: MN FiberHome Telecommunication Technologies Co., Ltd.

This quick start guide describes how to install and use the Signamax SFP 8-Port 100BaseFX SFP Fiber Switch.

A.1 Cisco ONS CL Shelf Specifications. This section includes hardware and software specifications.

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services

Overview: Cisco Series Router Shared Port Adapters

FCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

Gigabit Ethernet Switch With 10G Uplinks. Hardware Manual MS400860M

Optimux-34, Optimux-25

Installing the ASA 5550

9. NTP-C11 Remove and Replace an Ethernet Card, page 1-13 As needed, complete this procedure to remove and replace an ONS CL Ethernet card.

Product Overview. Switch Models CHAPTER

HX WCS Indoor DAS Remote Unit Quick Installation Sheet

Ethernet Cards. 5.1 Card Overview CHAPTER

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

Specification Sheet: HT SERIES

This Datasheet is for the IC693CBL300. I/O Bus Expansion Cables.

FCD-155. STM-1/OC-3 Terminal Multiplexer DESCRIPTION FEATURES

Metropolis ADM (Compact shelf)

Modular Connectors 75

Optimux-4T1 Four-Channel T1 Multiplexer

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Junos WebApp Secure 5.0 Hardware Guide

Quick Start Guide. Physical Description. The Port Status LEDs

Product Overview. Switch Descriptions. Front Panel CHAPTER

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu

FCD-155 STM-1/OC-3 Terminal Multiplexer

Target Interface / Construction Compliance Inspection Checklist

Installing the Cisco 2524 and Cisco 2525 Routers

Gmux Modular TDMoIP Gateway FEATURES

Manual Documentation Number EIR418-2SFP-T 0912m

1000Base-SX / LX to 10/100/1000Base-T 802.3at PoE Industrial Media Converter

PHB-200M PHB x 100/1000Base-T to 20x 100/1000Base-X

Target Interface / Construction Compliance Inspection Checklist

Connecting and Routing the Cables

Specifications and Part Numbers

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

Cisco ONS MA Shelf Assembly Hardware

Target Interface / Construction Compliance Inspection Checklist

Industrial Media Converters

Hardened PoE Ethernet Switch

Twisted Pair Cable Testers Int l Phone

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

RS-232 Fiber Link Card System

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

Quick Start Guide. C-100 Series Switches

SYSTIMAX Rack and Cabinet Solution

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

KIEN2204S Industrial Ethernet Switch Hardware Installation Manual

INSTALLATION INSTRUCTIONS. ACB-100 Audio Control Board. This document describes the installation procedure for the ACB-100 Audio Control Board.

Industrial IP67 Rated 8-Port 10/100Mbps M12 Fast Ethernet PoE Switch with Wide Operating Temperature

KOM600/KOM600G Fiber Media Converter Hardware Installation Manual

SWH-3112 Series 12-port L2+ Managed Gigabit Fiber Switch User s Guide

Instruction Manual MX2-MM-LX-SC MXR2-MM-LX-SC MX2-SM-LX-SC MXR2-SM-LX-SC Media Converter

RCC45 ➁ Overview / /

NVT Phybridge, Inc Superior Court, Unit 3 Oakville, ON, L6L 0C4 Phone: Web:

Installing the Cisco AS5400XM Universal Gateway

Industrial IEEE 802.3at Gigabit High Power over Ethernet Splitter

PS3108C. 8-Port Web Smart GbE PoE+ Switch QUICK INSTALLATION GUIDE

EP/2 Installation Instructions

ECS4620 Series 28/52-Port Layer 3 Stackable GE Switch Installation Guide

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

9/27/04 cci Cablecom Inc. 1

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

Overview. Features CHAPTER

LNX-0702G-SFP Series

Fiber optic converter audio and CAN TA OPERATION MANUAL

PIX 520. PIX 520 Product Overview CHAPTER

DVBS November 13, (12)

TIA/EIA 568A Sub-system HORIZONTAL CABLING

Product Overview. Features CHAPTER

Protocol Analyzers Cable and Accessory Guide

4K8 8-port Ethernet 10/100 Switch, 4K-Series

Datasheet. Fiber Optic Modular Patch Panel Features

Industrial 8-Port 10/100TX 802.3at PoE+ + 2-Port Gigabit TP/SFP Combo Ethernet Switch IFGS-1022HPT. User s Manual

MX Ring. WDM - MUX/DeMUX. MUX/DeMUX. Features Full native mode performance Optical connectors Passive model requires no power.

MEDIA CONVERTERS AND CHASSIS

Optimux-1032, Optimux-1025

Quick Start Guide. Physical Description.

APC Open Frame Rack Networking Solutions

iconverter 2-Module Power Chassis

MS400870M. User's Guide. Ver.: Port GBE SFP Switch 19 1U 24x10/100/1000T Combo 10/1000X SFP

INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET

LNX-1002C-SFP Series

Transcription:

Metropolis ADM MultiService Mux Compact Shelf Engineering and Ordering Information Release 5.0 ED8C938-10 Issue 5 13-May-2005 AN55 Copyright 2005 Lucent Technologies All Rights Reserved A A

About This Drawing This document provides application engineering details and ordering codes for Metropolis ADM MultiService MUX. Specifications and application considerations are included to properly engineer the network element for desired functionality, as well as condition the location for proper operation and maintenance. The most current Issue of this drawing can be obtained in paper format or electronically downloaded from the Lucent Corporate Information Center (CIC) by specifying the drawing number. The CIC website is accessed by non-lucent employees at http://www.lucentdocs.com/cgi-bin/cic_store.cgi. In addition, comments or questions concerning the document content should be directed through a Lucent Account Representative. For Lucent employees, the CIC website is accessed at http://www.cic.lucent.com/. Comments or questions can be directed to a SME identified via: http://mvcde.mv.lucent.com/eae/ Associated References 365-312-826 Application and Planning Guide 365-312-829 User Operations Guide 365-374-830 Alarm and Trouble Clearing Guide 365-312-827 Installation Guide Part 1 365-312-828 Installation Guide Part 2 365-312-831 Provisioning Guide ED8C938-20 Interconnect Information Reason for Re-issue Issue 1 05-15-03 Original Issue Issue 2 10-30-03 Release 3.3 Update Issue 3 05-20-04 Release 4.0 Added Software Ordering Table Issue 4 05-30-04 Release 4.0 Update Added PDP-M Kits Issue 5 05-13-05 Release 5.0 Added prefabricated cable assemblies ED8C938-10 Issue 5 A2

Table of Contents Description of Sheet Sheet Number Updated This Issue Title Sheet A1 * About This Drawing A2 * Reason for Re-issue A2 * Table of Contents A3 Engineering Notes A4 * Table A - Equipment Kits and Assemblies B1 Table B - Orderable Circuit Packs B2 * Table C- Paddle Boards B3 Table D - Line Build Outs (LBO) B3 * Table E - Cable Assemblies and Cable Kits B4 * Table F - Software Ordering Table B6 * Floor Plan Data C1 Figure 1 - ETSI 2200mm Rack Dimensions D1 Figure 2 - ETSI 2600mm Rack Dimensions D2 Figure 3 -Slot Identification D3 Figure 4 - Subrack Interconnect Interface D4 Figure 5 - Subrack Interface Dimensions for 19 Rack Mounting D5 Figure 6 - Subrack Interface Dimensions for ETSI Rack Mounting D6 Figure 7 - PDP-M Interface Dimensions D7 Figure 8 - PDP-MA D8 Figure 9 - Circuit Pack Faceplate SFP Interface LKA12 D9 Figure 10 - Patch Panel Kit D10 Figure 11 - E1 (2 Mbit/s) Paddle Boards and Patch Panel Interface D11 Figure 12 - Other Paddle Board Interfaces D12 Total Sheets 23 ED8C938-10 Issue 5 A3

Engineering Notes 1. For Lucent Engineered orders, job information shall be recorded by comcode number in the regional wiring lists. 2. The High Density Subrack (EHA1) includes mounting brackets for both ETSI Rack and 19" Rack installation. 3. Quick Copy block (QCB) kit comcodes listed are for the raw cable only. Order the QCB to receive all associated hardware to assemble the cable or kit. 4. If a PI- EI/63 unit is inserted in slot 7, it is in the protection unit and may not be used to carry traffic. 5. If LKA5 is inserted in Slots 1 and 2, only a 2Mbit/s Tributary interface unit (LKA2) is allowed in Slot 7. 6. The 2Mbit/s Paddle Boards extend below the bottom of the subrack when installed. This extends the overall height of the subrack to 925mm. Be sure to allow enough space below the subrack for installation or if future 2Mbit/ paddle boards will be required. 7. The Cable and Connector Kit 849005558 provides the following: 1 MD 1 Connector Kit 15P DSUB Male Connector, Hood and Ferrules 1 Station Alarm Kit 15P DSUB Male Connector, Hood and Ferrules 2 V11 Connector Kits 15P DSUB Male Connector, Hood and Ferrules 1 MD 2 Connector Kit 9P DSUB Male Connector, Hood and Ferrules 1 Q-Lan Connector Kit 9P DSUB Male Connector, Hood and Ferrules 2 G703 Connector Kits 9P DSUB Male Connector, Hood and Ferrules 2 Station Clock IN Connector Kits 9P DSUB Female Connector, Hood and Ferrules 2 Station Clock OUT Connector Kits 9P DSUB Male Connector, Hood and Ferrules 8. The Patch Panel kit is used when conversion from SC to FC interfaces are required for the optical tributaries. One Patch Panel kit is required for every LKA6 or LKA13 requiring this interface. Only one Patch Panel Kit is required for two of either LKA11 or LKA14 Circuit Packs. 9. Slot 7 is reserved for 1:N Protection when using electrical 2 Mbit/s or STM-1 tributary units. It can also be used for unprotected STM-1 optical interfaces (only in combination with core unit LKA5B). TransLAN units are not allowed in Slot 7. 10. The Patch Panel Kit can accommodate a maximum of 8 optical interfaces. An additional connector strip and cable kit increases the optical interfaces to 16. 11. The PDP-M Kit Supports 2 Subracks. If connecting more Subracks to the PDP-M, additional alarm cables must be ordered. The kit contains: 1 PDP-M 1 PDP-MA 1 1.6M (5.25 Ft) Alarm Cable (Upper Subrack) 1 3.2M (10.5 Ft) Alarm Cable (Lower Subrack) 12. The PDP-M Power Kit is required when ordering a PDP-M or PDP-M Kit. It Contains 2 Circuit Breakers (16A) and 2 Power Cables. One PDP-M power kit is required for each Subrack. 13. A Maximum of two subracks may be installed in a 300mm deep bay. 14. The LKA12B Circuit Pack may be used with release 4.0 software only for the Quality of Service (QOS) feature. Previous releases must use LKA12. ED8C938-10 Issue 5 A4

Features B Table A - Equipment Kits and Assemblies Description Comcode Figures Notes MADM (ETSI) Rack, 2200 mm 848586780 DA MADM (ETSI) Rack, 2600 mm 848586798 DA MADM (ETSI) Rack, 2200 mm 848929451 1 13 MADM (ETSI) Rack, 2600 mm 848929469 2 13 High Density Subrack Kit Contains subrack (EHA1) and mounting Hardware 848981239 3,4,5,6 13 High Density Subrack (EHA1) 848516589 3,4,5,6 DA Patch Panel Kit and Cables 848596045 10 8,10 Patch Panel Connector Strip (Additional) 848307112 10 10 Patch Panel Cable Kit (Additional) 848570511 10 10 PDP-M Kit 848983359 11 PDP-M Power Distribution Panel 848862330 7 11 PDP-MA Alarm Interface 848979761 8 11 PDP-M Power Kit 848983334 12 Circuit Breaker 16 Amp 408839413 12 ED8C938-10 Issue 5 B1

Features Table B - Orderable Circuit Packs Description Comcode Slot Notes Core Packs LKA1D, (SCI) SYSTEM CONTROLLER PLUS, 48 V, 1 UN, 0.06181 109307116 8 LKA5B, SI-L16.1C1/1 (RUBY) CROSS CONNECT 109055210 1,2 LKA10, SI-L16.2C1/1 CROSS CONNECT 108905571 1,2 LKA15, CC/PT 64/32 CROSS CONNECT 109307108 1,2 LKA42, 2X STM-4 L4.2 1.5 um CC/PT 64/32 LONG HAUL 109312629 1,2 LKA44, 2X STM-4 S4.1 1.3 um CC/PT 64/32 SHORT HAUL 109312645 1,2 STM-4, STM-1 Optical Tributary Port Units LKA11, (SI-S4.1/1) 1.3 um STM-4 109047811 3,4,5,6,7 1 Port LKA14, (SI-L4.2/1) LONG HAUL, 1.5 um STM-4 109202309 3,4,5,6,7 1 Port LKA6, (SI-S1.1/4) 1.3 um STM-1 108680042 3,4,5,6,7 4 Port LKA13, (SI-LI.2/4) LONG HAUL 1.5 um STM-1 109202291 3,4,5,6,7 4 Port Electrical Tributary Circuit Packs LKA2, (PI-E1/63) 2 Mbit/s 108676644 3,4,5,6,7 LKA8B, (PI-E3DS3/12) 34/45 Mbit/s 109311977 3,4,5,6 LKA3, (SI-1/4) 155Mbit/s 108676651 3,4,5,6 LKA4, (IP-LAN/8) 10/100Mbit/s 108676669 3,4,5,6 LKA16, (PI/DS1/63) 109464206 3,4,5,6,7 Other Circuit Packs and SFP (Small Form Factor Pluggable) LKA12, (IP-GE/2) 1000Base-SX/LX Lan Interface 109198259 3,4,5,6,7 LKA12B, (IP-GE/2) 1000Base-SX/LX Lan Interface with QOS 109570994 3,4,5,6,7 14 OMGBE-SX SX Gigabit Ethernet Module (SFP) 109294702 See Fig 9 2 per OMGBE-LX LX Gigabit Ethernet Module (SFP) 109294694 See Fig 9 LKA12 or LKA12B ED8C938-10 Issue 5 B2

Features Table C- Paddle Boards Description Code Use With Pack Notes PBE1-25 Pin D-Sub Connectors (75 Ohm) 108684390 LKA2 Figure 11 PBE2-25 Pin D-Sub Connectors (120 Ohm) 108684408 LKA2 Note 6 PBE4 - Field IO Connectors (75 Ohm) 109192120 LKA2 2 Mbit/s (E1) PBE4 - Field IO Connectors (120 Ohm) 109199521 LKA2 Figure 11 PBP7-15 pin D-Sub Connectors (75 Ohm) 109399592 LKA2 34 and 45 Mbit/s (E3/DS3) 155 Mbit/s (STM-1e) PBG4 (unprotected) 1.6/5.6 connectors 108905597 LKA8 PBG5 (protected) 1.6/5.6 connectors 108905605 LKA8 PBG2 (unprotected) 1.6/5.6 connectors 108746033 LKA3 PBG3 (protected) 1.6/5.6 connectors 108905589 LKA3 10 or 100 Mbit/s PBG1, IP-FE/8 PB-LAN/100/8 108720228 LKA4 P1-DS1/63 PBE12 - Field IO Connectors (100 Ohm) 109464222 LKA16 Figure 12 Table D - Line Build Outs (LBO) Description Code Use with Universal Build Out Block (UBOB) Use with SC connectors STM1 and STM 4 SC Type Connector 0 DB A3060 106708951 SC Type Connector 10 DB A3060D1 107406159 FC Type Connector 0 DB A3080 106795404 FC Type Connector 10 DB A3080D1 107406233 SC Buildout 0.5 DB ABSCS-0.5 109177634 SC Buildout 5 DB ABSCS-05.0 108617549 SC Buildout 10 DB ABSCS-10.0 108617556 ED8C938-10 Issue 5 B3

Features Table E - Cable Assemblies and Cable Kits Description Note Comcode Fiber Optic Cable Single Mode SC to SC 10.7 Meters (35 Feet) 106908320 Single Mode SC to SC 22.9 Meters (75 Feet) 106908387 Single Mode FC to PC 22.9 Meters (75 Feet) 847715877 Single Mode FC to PC 20 Meters (65.6 Feet) 847692811 Single Mode SC to FC 20 Meters (65.6 Feet) 848813770 Electrical Cable Assemblies Power Cables Subrack to PDP-M ( 2 Included with PDP-M Power Kit) 3 Meters (9.8 Feet) 848926903 Rack Alarm Cable Upper Subrack ( 1 Included with PDP-M Kit) 1.6 Meters (5.25 Feet) 848990255 Rack Alarm Cable Lower Subrack ( 1 Included with PDP-M Kit) 3.2Meters (10.5 Feet) 848990248 E1(2Mbit/s) 25 Pin Dsub to Open End (120 Ohm) 30 Meters (98.4 Feet) 848822169 E1 (2 Mbit/s) Field IO Cables 8 way Coax (75 Ohm) E1 (2 Mbit/s) STP Field IO Cables 8 way STP (120 Ohm) Without Overall Shield E1 (2 Mbit/s) UTP Field IO Cables 8 way UTP (120 Ohm) With Aluminum Foil and Copper Braid Shield DS1 (1.5 Mbit/s) Field IO Cables 8 way STP (100 Ohm) E3/DS3 1.6/5.6 Angle Connector Single Coax Cables (75 Ohm) 8 Meters (26.2 Feet) 848916763 12 Meters (39.4 Feet) 848916771 15 Meters (49.2 Feet) 848916789 22 Meters (72.1 Feet) 848916797 30 Meters (98.4 Feet) 848916805 50 Meters (164.0 Feet) 848916813 70 Meters (227.7 Feet) 848916821 8 Meters (26.2 Feet) 848916839 12 Meters (39.4 Feet) 848916847 15 Meters (49.2 Feet) 848916854 22 Meters (72.1 Feet) 848916862 30 Meters (98.4 Feet) 848916870 50 Meters (164.0 Feet) 848916888 70 Meters (227.7 Feet) 848916896 8 Meters (26.2 Feet) 848988515 12 Meters (39.4 Feet) 848988457 15 Meters (49.2 Feet) 848988465 22 Meters (72.1 Feet) 848988473 30 Meters (98.4 Feet) 848988481 50 Meters (164.0 Feet) 848988499 70 Meters (227.7 Feet) 848988507 100 Meters (328.0 Feet) 848988440 8 Meters (26.2 Feet) 848951976 15 Meters (49.2 Feet) 848951984 22 Meters (72.1 Feet) 848951992 30 Meters (98.4 Feet) 848952008 50 Meters (164.0 Feet) 848952016 2 Meters (6.6 Feet) 408882975 5 Meters (16.4 Feet) 408882983 10 Meters (32.8 Feet) 408882991 15 Meters (49.2 Feet) 408883007 20 Meters (65.6 Feet) 408883015 ED8C938-10 Issue 5 B4

Table E - Cable Assemblies and Cable Kits (Continued) Description Note Comcode E3/DS3 1.6/5.6 Angle Connector 8-Fold Coax Cables (75 Ohm) 2 Meters (6.6 Feet) 408883023 5 Meters (16.4 Feet) 408883031 10 Meters (32.8 Feet) 408883049 15 Meters (49.2 Feet) 408883056 20 Meters (65.6 Feet) 408883064 Cable (For building custom length) CIT Cable 200 Meters (656 Feet) 848069795 Station Clock Cable (1 Pair) 200 Meters (656 Feet) 407173418 G.703 Interface Cable (2 Pair) 500 Meters (1640 Feet) 848004495 Cat 5 Cable (4 Pair 26 AWG) 500 Meters (1640 Feet) 408386175 Q-LAN Cable (4 Pair UTP Shielded) 500 Meters (1640 Feet) 848004503 Connector and Cable Kits Connector Kit 2MB Field IO Connectors For Coax Cable 1 Piece 408760353 Connector Kit 2MB Field IO Connectors For STP Cable 1 Piece 408760361 Crimping Tool for 2MB Field IO Connectors (Coax or STP) 408759587 Connector Kit 2MB 75/120 Ohm (25 Pin D-Sub) 16 Pieces 848592556 Connector Kit E3/DS3 75 Ohm (1.6/5.6) 24 Pieces 848813754 Connector Kit STM-1 (1.6/5.6) 8 Pieces 848813762 Connector Kit LAN (RJ-45) 8 Pieces 848592549 Cable and Connector Kit (Subrack Interface Cables) DA 848556239 Cable and Connector Kit (Subrack Interface Cables) See Note 7 849005558 Quick Copy Block kits (See Note 3) 6 MM2 Red QCB-6701 300509668 6 MM2 Blue 15 Meters 300480910 Rack Power Cables 10 MM2 Red QCB-6702 407686799 10 MM2 Blue 25 Meters 407686807 16 MM2 Red QCB-6703 300498334 16 MM2 Blue 35 Meters 300498342 Rack Ground Cable 35 MM2 Green/Yellow QCB-6704 408842862 Concrete Floor Connection Kit - Expanding Bolts M8 QCB-6705 Raised Floor Connection Kit - Hex Bolts M10 QCB-6706 Fiber Duct Kit - Orange and Black Conduit QCB-6707 ED8C938-10 Issue 5 B5

System Software CIT Interface Software Table F - Software Ordering Table Description Code Release 2.1.4 CD Rom 109445627 Downloadable 109445601 Release 3.1 CD Rom 109310672 Downloadable 109310656 Release 3.2.1 CD Rom 109480814 Downloadable 109480798 Release 3.3.1 CD-Rom 109505057 Downloadable 109505016 Release 4.0 Earth CD-Rom 109505099 Downloadable 109505081 Release 5.0 Mars CD-Rom 109505099 Downloadable 109546085 Release 9.14 Pearl Use with Release 2.1.4 109546077 Release 10.11.1 Garnet 109528950 Use with Release 3.1, 3.2, 3.3 Release 11.11 Mercury 109490607 Release 12.01 Venus Use with Release 3.1, 3.2.1, 3.3 109504468 Release 13.05 Earth M5 Use With Release 4.0 109557215 Release 14.02 Earth M2 Use With Release 5.0 109563619 ED8C938-10 Issue 5 B6

Floor Plan Data - Metropolis ADM MultiService Mux (Compact Shelf) Description Power Consumption Value 204W (MAX) 600 [23.62] Operating Voltage Range Subrack Weight (With Circuit Packs, Paddle Boards and Cables) Operating Temperature -48 to -60 VDC 70 Kg (154 LBS) -5C to 45C 300 [11.81] Storage Temperature -25C to 55C 550 [21.65] Transport Temperature -40C to 70C Hole Locations for Anchors Mounting Details for 300mm Racks 750mm REAR AISLE 750 FRONT AISLE TYPICAL BAY FRAME LAYOUT FOR CENTRAL OFFICE TOP VIEW ED8C938-10 Issue 5 C1

D Figure 1 - ETSI 2200mm Rack Dimensions Rack Alarm Assembly 600 [23.62] 300 [11.81] 2200 [86.61] ED8C938-10 Issue 5 D1

Figure 2 - ETSI 2600mm Rack Dimensions Rack Alarm Assembly 400 [15.75] 600 [23.62] 300 [11.81] 2200 [86.61] ED8C938-10 Issue 5 D2

Figure 3 -Slot Identification Core 1 Core 2 TS1 TS2 TS3 TS4 TS5 SC Slot 1 2 3 4 5 6 7 8 PB1 PB2 PB3 PB4 ED8C938-10 Issue 5 D3

Figure 4 - Subrack Interconnect Interface View A Power 1 2 OUT 1 IN 1 OUT 2 IN 2 FAN MD 1 STAT ALM V11-1 G703-1 G703-2 Q-LAN CITF STAT CLOCK BTALM MD 2 V11-2 SEEPROM ED8C938-10 Issue 5 D4

Figure 5 - Subrack Interface Dimensions for 19 Rack Mounting 483.5 [19.0] 263.4 [10.4] 16.7 [0.7] 27.8 [1.1] 244.8 [9.6] 625.5 [24.6] 335 [13.2] 279.4 [11.0] ED8C938-10 Issue 5 D5

Figure 6 - Subrack Interface Dimensions for ETSI Rack Mounting 535 [21.1] 263.4 [10.4] 515 [20.3] 16.7 [0.7] 18.5 [0.7] 20.8 [0.8] 10.1 [0.4] 253.3 [10.0] 624.5 [24.6] 335 [13.2] 256.5 [10.1] ED8C938-10 Issue 5 D6

Figure 7 - PDP-M Interface Dimensions 478.3 [18.83] 465.0 [18.31] ETSI Mounting Bracket Mounting Holes For ETSI-2 Mounting GROUNDING THREADS 25.0 [0.98] 40.3 [1.59] 97.6 [3.84] 515.00 [22.28] 537.3 [21.15] 115.3 [4.54] ED8C938-10 Issue 5 D7

Figure 8 - PDP-MA PDP-MA Mounted on top of PDP-M 4-pin locking connectors 6 places 62.4 [2.5] 67.5 [2.7] Left View 28.5 [1.1] 123.4 [4.9] Top View ED8C938-10 Issue 5 D8

Figure 9 - Circuit Pack Faceplate SFP Interface LKA12 Remove dust caps insert SFP Modules RX1 TX1 RX2 TX2 LKA12 ED8C938-10 Issue 5 D9

Figure 10 - Patch Panel Kit 112.7 [4.44] 7.5 [0.30] 7.4 [0.29] Patch Panel Cable Kit Patch Panel Connector Strip 189 [7.44] Fiber optic cable SC to SC 1.3 Meters Long (8) 59 [2.32] 15 [0.59] SC to FC Adapter (8) 23.5 [0.93] ED8C938-10 Issue 5 D10

Figure 11 - E1 (2 Mbit/s) Paddle Boards and Patch Panel Interface 925 [36.4] PBE3 PBE4 Field IO (16) PBP7 15 Pin D-Sub (16) Patch Panel PBE1 PBE2 25 Pin D-Sub (16) ED8C938-10 Issue 5 D11

Figure 12 - Other Paddle Board Interfaces PBG3 1.6/5.6 (8) PBG5 1.6/5.6 (24) PBE12 Field IO (16) PBG1 RJ-45 (8) PBG2 1.6/5.6 (8) PBG4 1.6/5.6 (24) Protected Configuration ED8C938-10 Issue 5 D12