RER 123 Bus Connection Module. Technical Description

Similar documents
SPA-ZC 200/SPA-ZC 202 IEC /SPA-gateway Modules. Installation Manual

SPA-ZC 17. Bus connection module SPA-ZC 17. User s manual and Technical description. Tx SC Rx BB BM MB MM SPA / RS 485 POWER SLAVE 1 MASTER 0

SREDU Double Connection Option Card for Lon Star Coupler RER 111

Protection Relay RE_ 610. Installation Manual

Synchro-check relay. Application

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Overcurrent and Earth-Fault Relay REJ 525. Technical Reference Manual

800xA Networks. NE801 User Manual. Power and productivity for a better worldtm

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

Protection System Simulator SIM600. Installation Manual

LON bus communication devices 1MRS MBG Page 1 Issued: April 1999 Status: New Data subject to change without notice

Earth-fault Relay SPAJ 110 C. Product Guide

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

Feeder protection relay SPAA 121 C. Product Guide

Data communication and reporting unit

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Residual overvoltage relay

ABB ABB Oy, Distribution Automation

ABB Drives. User s Manual I/O Module Adapter AIMA-01

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Data communication and reporting unit

COM600 Station Automation Series MNS is Connectivity (OPC) 3.2. User's Guide

Connectivity Packages. User's Guide - ANSI Version

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

Installation Instructions

DDR. User s Guide ND040012E. We reserve all rights in this document and in the information contained therein. Copyright 2014 Newcon Data AB

Feeder protection relay SPAA 341 C. Product Guide

Arc protection relay. Features Three-phase overcurrent function. Application

Ethernet Adapter. Modbus/TCP Brigde. Installation and Commissioning Manual

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

InView Communication Modules

Motor Control and Protection Unit M10x AO Module User Guide

Arc protection relay. Features Three-phase overcurrent function. Application

COM600 Station Automation Series External OPC Client Access 3.1. User's Guide

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

SMS 510, CAP 505 LON Gateways Configuration Configuration Guide

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

MEC-COM-M154. User s Manual

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

Manual Fiber Optic Interfaces

Communication Gateway COM 500. Product Guide

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

Communication Gateway COM 610. Product Guide

CFO100 Series. User Manual CRT141 & CRR141. CFO141 User Manual, , rev001

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Tap Manager TM100. Operating Instructions

Kinetix 6000 Axis Module and Shunt Module

Data Sheet 1SD210F2-5SNA0750G Single-Channel SCALE Plug-and-Play IGBT Driver

MEC-COM-M114. User s Manual

TCF-142 Quick Installation Guide

Feeder protection relay

High Impedance Protection Relay SPAE010, SPAE011. Product Guide

RTU560 Remote Terminal Unit Connections and Settings

PHOENIX CONTACT - 05/2007

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

Data Sheet 1SD210F2-5SNA1200G Single-Channel SCALE Plug-and-Play IGBT Driver

SATEL-LP-AI4. I/O extension module, 4 analog current inputs. Data sheet. 1 Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

Quick Start Guide Elinx ESW100 Series. 5 and 8 port Unmanaged Ethernet Switch

ICF-1150 Series Quick Installation Guide

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount

SPA-ZC 302. Profibus-DPV1/SPA Gateway. Product Guide. spa-zc302_rightco300

MGate 4101-MB-PBS Series

Installation Instructions

Channel Switch CS. General Operating, Maintenance and Installation Manual

CAP 505. User s Guide

MED102A. Industrial Serial to Single-mode Fiber Converter

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

GT- IRDM-9603 Product description Rev. 2 17/06/2014

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

F2MC MB90385 series Evaluation Board Documentation. Revision Date Comment V New document

ADA User manual ADA RS-232 to Multidrop Fiber Optic Converter. 1 io_ada-7210_en_v3.17. Copyright CEL-MAR sp.j.

SIMADYN D Digital Control System. Fiber-Optic Rack Coupling CS12. User Manual. Edition DK No

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language)

CPCI-PS24 24V-Power Supply

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Bluetooth RS-232 Dongle. User s Manual BTS-100

Intrinsically safe batch controller Batching Master 110i

Serial Interface Modules TTL to RS232/RS485/RS422

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

High impedance protection relay

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

ControlNet Comm Glass Fiber Adapter Kit

Fics-TPC1 Motion Controller. User Manual. Dynaservo Inc.

Communicate IT Software module DR-COM. Buyer s Guide

TCF-142-RM Series Hardware Installation Guide

EX-RC1 Remote I/O Adapter

Quick Start Guide Elinx ESW200 Series. 5 and 8 port Unmanaged Ethernet Switch

Converter Box Data Sheet

MGate MB3170/MB3270 Quick Installation Guide

Part no.: CML720i-T R-M12 Light curtain transmitter

Feeder Protection Relay REF 610. Product Guide

Anybus CompactCom Starter Kit REFERENCE GUIDE

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

Transcription:

Bus Connection

1MRS751143-MUM Issued: 06.11.1998 Version: E/08.07.2005 Bus Connection 1. About this manual...4 1.1. Copyrights...4 1.2. Trademarks...4 1.3. Guarantee...4 2. Safety information...5 3. General...6 4. Principle of operation...7 5. Construction and mounting...8 6. Type designation...10 7. Fibre-optic connectors and technical data...11 Copyright 2005 ABB Oy, Distribution Automation, Vaasa, FINLAND 3

Bus Connection 1MRS751143-MUM 1. About this manual 1.1. Copyrights 1.2. Trademarks 1.3. Guarantee The information in this document is subject to change without notice and should not be construed as a commitment by ABB Oy. ABB Oy assumes no responsibility for any errors that may appear in this document. In no event shall ABB Oy be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, nor shall ABB Oy be liable for incidental or consequential damages arising from use of any software or hardware described in this document. This document and parts thereof must not be reproduced or copied without written permission from ABB Oy, and the contents thereof must not be imparted to a third party nor used for any unauthorized purpose. The software or hardware described in this document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license. Copyright 2005 ABB Oy All rights reserved. ABB is a registered trademark of ABB Group. All other brand or product names mentioned in this document may be trademarks or registered trademarks of their respective holders. Please inquire about the terms of guarantee from your nearest ABB representative. 4

1MRS751143-MUM Bus Connection 2. Safety information Dangerous voltages can occur on the connectors, even though the auxiliary voltage has been disconnected. National and local electrical safety regulations must always be followed. The device contains components which are sensitive to electrostatic discharge. Unnecessary touching of electronic components must therefore be avoided. Only a competent electrician is allowed to carry out the electrical installation. Non-observance can result in death, personal injury or substantial property damage. 5

Bus Connection 1MRS751143-MUM 3. General The bus connection module acts as an interfacing unit between an RE_ 54_ device and a fibre-optic SPA, DNP 3.0, Modbus or IEC 60870-5-103 bus. The bus connection module converts incoming optical signals from the bus to electrical RS-232 signals for the RE_ 54_ devices and vice versa. The module is connected to a host device with a 9-pin D-type RS-232 connector on the rear plate of the RE_ 54_ device via a cable delivered with the module. It can be used together with any RE_ 54_ device provided with a 9-pin D-type RS-232 connector. The bus connection module is also powered from the same D-type connector of the RE_ 54_ device. The box includes a bus connection module (), a connection cable, two jumpers, and an installation plate. The RS-232 interface of the bus connection module is shown in the figure below. Rx Tx D9 male connector 5 1 9 6 Pin Signal 1 n.c. = not connected 2 RXD 3 TXD 4 +15 V DC 5 GND 6 connected to pin 7 7 connected to pin 6 8 n.c. 9 n.c. RS232 D9P-connector A050298 A050299 Fig. 3.-1 9-pin D-type connector and block diagram. 6

1MRS751143-MUM Bus Connection 4. Principle of operation The bus connection module can be used in Loop and Star type bus topologies. Also the line idle state of the module is selectable. It can be light on or off. The selection of Loop/Star and light on/off is made by jumpers. In the Loop topology the module passes a message received from the fibreoptic interface both to the fibre-optic transmitter and the RS-232 interface. In the Star topology the module passes a message received from the fibre-optic receiver only to the RS-232 interface. A message received from the RS-232 interface is passed to the fibre-optic transmitter in both bus topologies. SPA bus communication is using Loop and light off modes, when the module jumpers are in Loop and light off positions. IEC_103 bus communication is using Star and light on or off modes, when the module jumpers are in Star and light on or off positions. DNP 3.0 and Modbus support all jumper combinations. Fig. 4.-1 Rear side of the module A050300 Table 4.-1 Settings of the jumper Topology Light on/off Protocol Star Off IEC_103, DNP 3.0, Modbus Star LIght IEC_103, DNP 3.0, Modbus Loop Off SPA, DNP 3.0, Modbus Loop Light DNP 3.0, Modbus 7

Bus Connection 1MRS751143-MUM 5. Construction and mounting The consists of a printed circuit board and is housed in a plastic case. It can be mounted on the rear side of the RE_ 500 device by using the mounting plate and cable delivered with the module. See Figure 5.-2. 20.0 35.0 73.0 Fig. 5.-1 Dimensional drawing of the bus connection module A050301 Fig. 5.-2 Mounting of the A050302 8

1MRS751143-MUM Bus Connection Connect the cable between the device and the bus connection module and lock it by tightening the finger screws in both ends. To meet the specified EMC requirements, only the connection cable (1MRS120524) delivered with the module may be used between the and the device. The incoming optical fibre is connected to the receiver input Rx and the outgoing optical fibre to the transmitter output Tx. Special attention must be paid to the handling, mounting, connection, etc. of optical fibres. The can be provided with connectors for two plastic fibre cables, two glass fibre cables or one of each type. For additional information, refer to the manual Plastic-core fibre-optic cables. Features and instructions for mounting (34 SPA 13 EN1). 9

Bus Connection 1MRS751143-MUM 6. Type designation Type designation Transmitter Receiver Ordering number Plastic Plastic RER123-BB Plastic Glass RER123-BM Glass Plastic RER123-MB Glass Glass RER123-MM The IEC star-coupler RER 125 supports only glass-glass and plastic-plastic transceiver connections. RER123-MB Type Optical receiver: B = plastic fibre cable M = glass fibre cable Optical transmitter: B = plastic fibre cable M = glass fibre cable A050303 10

1MRS751143-MUM Bus Connection 7. Fibre-optic connectors and technical data Table 7.-1 Fibre-optic connectors Glass fibre Plastic fibre Cable connector ST connector snap-in connector Cable diameter 62.5/125 um 1 mm Max. cable length 1000 m 20 m Wavelength 820-900 nm 660 nm Transmitted power -13 dbm (HFBR-1414) -13 dbm (HFBR-1521) Table 7.-2 Technical data Auxiliary power supply Powered from a host device (9/15 V DC) Burden ~ 1.2 W Max. data transfer rate 19.2 kbps Mechanical dimensions Width: 35.0 mm Height: 73.0 mm Depth: 20.0 mm Operating temperature range Storage temperature range with RE_ 54_ Connection cable 1MRS120524-10 55 o C -40 70 o C Width: 25 cm Length: 350.0 mm 11

ABB Oy Distribution Automation P.O. Box 699 FI-65101 Vaasa FINLAND Tel. +358 10 22 11 Fax. +358 10 224 1094 www.abb.com/substationautomation 1MRS751143-MUM EN 07.2005