RGB Power Batten. User Manual. Order code: EQLED032

Similar documents
Blitzer Strobe. User Manual. Order code: EQLED366

UV Power Flood. User Manual. Order code: EQLED029

Microbar COB System. User Manual. Order code: EQLED137

Crossfire. User Manual. Order code: EQLED061

Blitzer RGB Strobe. User Manual. Order code: EQLED365

Gobo Projector XP 80W

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

UV Spectra Batten 12 x 5W UV LEDs

Performer 18 RGBWA MKII

Performer 18 HEX. 18 x 12W 6-in-1 colour LEDs (RGBWAUV) User Manual. Order code: LEDJ252B

Slimline CW & WW Series

PF LED Profile. User Manual

ZF LED Zoom Fresnel. User Manual

Fusion Razor Beam. 3 x 12W Moving Head User Manual. Order code: EQLED006

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

HEX Par 9 MKII. Exterior Fixture User Manual. Order code: LEDJ226

CDP 405 Digital Dimmer Pack

CS2 DMX Distribution Splitter

Fusion Saber. User Manual. Order code: EQLED070

Vector Beam White. User Manual. Order code: LEDJ265

DMX LED Starcloth Systems

Microbar Multi System

MICRON DJ Booth Tri-colour Starcloth

Intense 9P10 RGBWA LED Slim Par

Saturn Spot. User Manual. Order code: EQLED023

Vortex. User Manual. Order code: EQLED073

IMPACT Order code: EQLED79

LIGHT BRICK - 12 X 3W TRI-COLOUR

Order code: EQLED60 USER MANUAL

w w w. p r o l i g h t. c o. u k STAGE PAR 64

Hypnos. User Manual. Order code: EQLED372

Endura 1Q120 RGBW COB Exterior Fixture

MICRON DJ Booth System with Overhead Kit & CW Starcloth

Intense 9HEX10 LED Slim Par

w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL

EasiLED 4 DMX Controller

w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

Slimline 12Q5 Series

Fresco 24 RGBW. Exterior Fixture User Manual. Order code: LEDJ267

Colour Burst Order code: LEDJ01 USER MANUAL

User Manual Equinox 2m Flight Cased DMX LED Flame Machine Order code: FLAM12

LEDJ Tri LED DJ Skirt Matrix Cloth - STAR17 USER MANUAL

order code: EQLED40 user manual

Flexoled FTP3HP RGB LED DMX Driver

Order code: EQLED53 User manual

FTP1 Single Channel LED DMX Driver

Professional DMX Stage Backdrop

Starlit Dance Floor. User Manual

50W/100W LED Alu. User Manual. Code: ELUM041-50W - (5600K) Code: ELUM041A - 100W (5600K) Code: ELUM041C - 50W - (3200K) Code: ELUM041D - 100W (3200K)

TRANSCENSION Show Control

User Instructions. American DJ

CPA 40 Two Channel Amplifier

LED PAR56 Order Code: P56-151

Heavy Duty DMX Mirror Ball Rotator with Safety Eye

TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Connections 6.

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

order code: EQLA04 user manual

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

SP-1500 DMX MK II Strobe

DDS-405 LC DMX 4 Ch. Dimmer dimmer pack. user manual

LED W RGBA User Manual

xbrick Full-Colour 16 3W LED floodlight user manual

Party Dimmer IEC ORDERCODE 50324

LED MOVING HEAD FLEX BEAM K8 RGBW. User Manual. Please read the instruction carefully before use

Robot Light V2. User Manual

Flat Par 9 LEDs. battery power, Wirelss, Remote Control, RGBWA-UV 6-in-1 USER MANUAL. Please read over this manual before operating the light

Octostrip ORDERCODE 42220

LED DANCING FLOOR User Manual

FLEX BEAM V8. User Manual Please read the instruction carefully before use

TourPro RGBAW Stagebar USER MANUAL

BGS 20T 100V/8Ω Background Music Loudspeakers

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

Outdoor Stage PAR 12 3W Tri LED-PAR. user manual

Cobra Dimmer Master DMX Controller User Manual

MATRIX LED LED User Manual Please read the instructions carefully before use

COLOR PAR 56 COLOR PAR 64. User Manual Please read the instructions carefully before use. Широкий ассортимент оборудования ACME на

RGBW Mini Moving Head Stage Spot Light Model: SSL1. User Manual.

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

FUSION SPOT MKII EQUINOX. Contents. User Manual. Order codes: Black housing - EQLED Safety Instructions. 2. Features & Specifications

Springtree Spatial Wash COB RGBW

LED BEAM 300 LED-MB50. User. Guide. Professional Entertainment Technology

Professional Entertainment Technology LED BEAM 300 LED-MB50. Innovation, Quality, Performance 23-

Professional Entertainment Technology LED BEAM 300 LED-MB50. User. Guide

CP 64 BD15 CP 64 PD15

Multidim ORDERCODE 50391

STAGE TRI-PAR 18TC CP-18TC. User Manual. Please read the instructions carefully before use

Power LED Beam 56 Narrow

User Manual Please read the instructions carefully before use

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

VBAR 270. User Manual. Version 1.2

Kam StarWash Multicolour wash effects with green & red star cluster laser

DPX-620III 6-Ch. dimmer pack. user manual

LED Pixel Rail Drive 640 controller. user manual

Please read the instructions carefully before use LED PYRAMID LED-904D. Innovation, Quality, Performance 15-

LED Slimline PAR RGBW 7x8W

1 Channel Strobe Controller ORDERCODE 40226

LED Accu Penta 9x12W RGBWAU

10W LED PIN SPOT. User Manual LED-PS10D W. Innovation, Quality, Performance. Professional Entertainment Technology 11-

7x15W 4IN1 Infinity Rotation LED Pixel Bar. This product manual contains important information about the safe

Transcription:

RGB Power Batten User Manual Order code: EQLED032

Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CARE- FULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make sure that there is no damage caused during transportation. Should there be any damage, consult your dealer and do not use the equipment. To maintain the equipment in good working condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual. Please note that damages caused by user modifications to this equipment are not subject to warranty. CAUTION! KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS CAUTION! TAKE CARE USING THIS EQUIPMENT! HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!! IMPORTANT: The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment. Never let the power cable come into contact with other cables. Handle the power cable and all mains voltage connections with particular caution! Never remove warning or informative labels from the unit. Do not open the equipment and do not modify the unit. Do not connect this equipment to a dimmer pack. Do not switch the equipment on and off in short intervals, as this will reduce the system s life. Only use the equipment indoors. Do not expose to flammable sources, liquids or gases. Always disconnect the power from the mains when equipment is not in use or before cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the power-cable. Make sure that the available mains supply voltage is between 100~240V AC, 50/60Hz. Make sure that the power cable is never crimped or damaged. Check the equipment and the power cable periodically. If the equipment is dropped or damaged, disconnect the mains power supply immediately and have a qualified engineer inspect the equipment before operating again. WARRANTY: One year from date of purchase. OPERATING DETERMINATIONS If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. Do not endanger your own safety and the safety of others! Incorrect installation or use can cause serious damage to people and/or property. If the equipment has been exposed to drastic temperature fluctuation (e.g. after transportation), do not connect power or switch it on immediately. The arising condensation might damage the equipment. Leave the equipment switched off until it has reached room temperature. If your product fails to function correctly, stop use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Pro Light dealer for service. Only use fuses of same type and rating. Repairs, servicing and power connection must only be carried out by a qualified technician. THIS UNIT CONTAINS NO USER SERVICEABLE PARTS. This lighting fixture is for professional use only - it is not designed for or suitable for household use. The product must be installed by a qualified technician in accordance with local territory regulations. The safety of the installation is the responsibility of the installer. The fixture presents risks of severe injury or death due to fire hazards, electric shock and falls. Warning! Risk Group 2 LED product according to EN 62471. Do not view the light output with optical instruments or any device that may concentrate the beam. www.prolight.co.uk RGB Power Batten User Manual 2

Product overview & technical specifications RGB Power Batten The 1m RGB Power Batten contains 240 RGB LEDs divided into 8 segments. On board features include colour mixing to create soft washes from its rich colour palette, and chase programs controlled in auto mode or activated by music. Several different chase programs are included and can be selected by the control panel along with brightness and speed. 240 x 10mm LEDs (R: 96, G: 72, B: 72) Beam angle: 30 DMX channels: 2/3/4/7/14 or 26 selectable Sound active, auto and master/slave modes 0-100% dimming and variable strobe Bracket allows for multiple rigging or floor standing applications 4 push button menu with LED display IEC power input/output 3-Pin XLR input/output Convection cooled Specifications 30 - Lux 2960 741 329 185 119 Power consumption 30W Power supply 100~240V, 50/60Hz Fuse T1A 250V 30 Dimensions 85 x 1075 x 65mm Weight 1.8kg Order code EQLED032 0m 1m 2m 3m 4m 5m 1075mm 65mm 85mm www.prolight.co.uk RGB Power Batten User Manual 3

POWER INPUT: 100-240V~50/60Hz FUSE: T1A 250V MENU ENTER UP DOWN DMX IN DMX OUT POWER OUTPUT: 100-240V~50/60Hz Technical specifications 08 03 10 04 05 06 07 09 POWER INPUT: 100-240V~50/60Hz FUSE: T1A 250V MENU ENTER UP DOWN DMX IN DMX OUT POWER OUTPUT: 100-240V~50/60Hz RGB POWER BATTEN www.prolight.co.uk 01 02 01 - Bracket tightening knobs 02 - Bracket 03 - Earth point 04 - LED display 05 - Function buttons 06-3-Pin XLR input 07-3-Pin XLR output 08 - IEC power input 09 - IEC power output 10 - Fuse T1A 250V In the box: 1 x fixture, 2 x mounting brackets/feet 1 x power cable & 1 x user manual www.prolight.co.uk RGB Power Batten User Manual 4

Operating instructions d. 0 0 1 d. 0 0 1 d. 5 1 2 d - p 1 d - p 6 DMX address setting Channel mode S L a v Slave mode S U 0 0 S U 0 0 S U 3 1 Sound sensitivity r 0 0 0 r 2 5 5 C O L r g 0 0 0 g 2 5 5 Static colour mode b 0 0 0 b 2 5 5 S P 0 1 S P F L MENU P r - - 1 - - r 2 - r g 3 - - g 4 - g b P r 0 1 5 - - b 6 - r b 7 r g b 8 O F F P r 0 2 P r 2 0 S P 0 1 F d 0 0 S P F L F d 9 9 F d 0 0 1 - - r 1 - r g 1 - - g 1 - g b 1 - - b 1 - r b 1 r g b 1 O F F 2 - - r 2 - r g F d 9 9 Built-in programs P r 2 1 P r 2 2 2 - - g A u t 0 n 0 0 1 s P 0 0 F d 0 0 n 1 0 0 S P F L F d 9 9 Auto mode 2 - g b 2 - - b 2 - r b 2 r g b 2 O F F www.prolight.co.uk RGB Power Batten User Manual 5

Operating instructions DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show. In this mode you will be able to control each individual trait of the fixture and each fixture independently. To access the DMX address mode, press the MENU button on the front of the unit to show d.001 on the LED display. Now use the UP and DOWN buttons to set the required DMX address. Press the ENTER button to confirm the setting. The display will now show d-p1 on the LED display. Now use the UP and DOWN buttons to choose one of the 2/3/4/7/14 or 26 DMX channel modes. Press the ENTER button to confirm the setting. To exit out of any of the above options, press the MENU button. d-p1-3 channel mode d-p2-4 channel mode 2 channel mode: d-p3-14 channel mode d-p4-26 channel mode d-p5-2 channel mode d-p5-7 channel mode Value CH1 CH2 000-007 No funtion No funtion 008-015 016-023 Yellow 024-031 032-039 Cyan 040-047 048-055 Purple 056-063 White 064-071 Program 1 072-079 Program 2 080-087 Program 3 088-095 Program 4 096-103 Program 5 104-111 Program 6 112-119 Program 7 120-127 Program 8 128-135 Program 9 136-143 Program 10 144-151 Program 11 152-159 Program 12 160-167 Program 13 Speed 168-175 Program 14 176-183 Program 15 184-191 Program 16 192-199 Program 17 200-207 Program 18 208-215 Program 19 216-223 Program 20 224-231 Program 21 232-255 3 channel mode: CH1 CH2 CH3 4 channel mode: CH1 CH2 CH3 CH4 Sound active mode Speed Sound sensitivity Master dimmer www.prolight.co.uk RGB Power Batten User Manual 6

Operating instructions 7 channel mode: Value CH1 CH2 CH3 CH4 CH5 CH6 CH7 000-007 008-015 016-023 Yellow 024-031 032-039 Cyan 040-047 048-055 Purple 056-063 White 064-071 Program 1 072-079 Program 2 080-087 Program 3 088-095 Program 4 096-103 Program 5 104-111 Program 6 112-119 Program 7 120-127 Program 8 128-135 Program 9 136-143 Program 10 144-151 Program 11 152-159 Program 12 160-167 Program 13 168-175 Program 14 176-183 Program 15 184-191 Program 16 192-199 Program 17 200-207 Program 18 208-215 Program 19 216-223 Program 20 224-231 Program 21 No funtion No funtion No function Speed Flash Master dimmer 232-255 Sound active mode Sound sensitivity No funtion No funtion 14 channel mode: CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 1&2 1&2 1&2 3&4 3&4 CH10 CH11 CH12 CH13 CH14 7&8 7&8 7&8 Flash Slow-fast Master dimmer 3&4 5&6 5&6 5&6 www.prolight.co.uk RGB Power Batten User Manual 7

Operating instructions 26 channel mode: CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 1 1 1 2 2 2 3 3 3 CH10 CH11 CH12 CH13 CH14 CH15 CH16 CH17 CH18 4 CH19 CH20 CH21 CH22 CH23 CH24 CH25 CH26 7 4 7 4 7 5 8 5 8 5 8 6 Flash Slow-fast 6 Master dimmer 6 Auto mode: To access auto mode, press the MENU button on the front of the unit to show Auto on the LED display. Now press the ENTER button and use the UP and DOWN buttons to choose the required program n001 ~n100. Press the ENTER button then use the UP and DOWN buttons to select the running speed SP01 ~ SPFL. Press the ENTER button again and use the UP and DOWN buttons to select the fading time Fd00 ~ Fd99. Finally press the ENTER button and use the UP and DOWN buttons to select the flash speed F500 ~ F599. Press the ENTER button to confirm the setting. Master/slave mode: The default setting for this fixture is Master. To set the slave unit, press the MENU button on the front of the master unit to show SLav on the LED display. The unit is now in Slave mode. To exit out of any of the above options, press the MENU button. Please ensure that all slave units are set to the same DMX channel mode as the master unit. Sound active mode: To access the sound active mode, press the MENU button on the front of the unit to show SU31 on the LED display. Now press the ENTER button and use the UP and DOWN buttons to set the sound sensitivity 01 ~ 31. Press the ENTER button to confirm the setting. Value: 01-31 (01 = low sensitivity, 31 = high sensitivity) To exit out of any of the above options, press the MENU button. www.prolight.co.uk RGB Power Batten User Manual 8

Operating instructions Static colour mode: To access the static colour mode press MENU until Colr shows on the LED display. Now press the ENTER button and use the UP and DOWN buttons to select the brightness between r.000 ~ r.255. Press the ENTER button and repeat for green (G) and blue (b). Value: 000-255 (000 = low brightness, 255 = high brightness) To exit out of any of the above options, press the MENU button. Built-in programs: To access the built-in programs, press the MENU button on the front of the unit to show Pr-- on the LED display. Now press the ENTER button and use the UP and DOWN buttons to choose the required program Pr01 ~ Pr31. Press the ENTER button to confirm the setting. Pr01 - Now use the UP and DOWN buttons to select the required colour. Press the ENTER button to confirm the setting and use the UP and DOWN buttons to choose the flash speed F500 ~ F599. Press the ENTER button to confirm the setting. Pr02 ~ Pr20 - Now use the UP and DOWN buttons to select the running speed SP01 ~ SPFL. Press the ENTER button to confirm the setting. Now use the UP and DOWN buttons to select the flash speed F500 ~ F599. Press the ENTER button to confirm the setting. Finally use the UP and DOWN buttons to select the fading time Fd00 ~ Fd99. Press the ENTER button to confirm the setting. Pr21 ~ Pr22 - Now use the UP and DOWN buttons to select the running speed SP01 ~ SPFL. Press the ENTER button to confirm the setting. Now use the UP and DOWN buttons to select the flash speed F500 ~ F599. Press the ENTER button to confirm the setting. Use the UP and DOWN buttons to select the fading time Fd00 ~ Fd99. Press the ENTER button to confirm the setting. To set the background colour use the UP and DOWN buttons to select between 1--r ~ 1OFF. Press the ENTER button to confirm the setting. Fianlly to set the chasing colour use the UP and DOWN buttons to select between 2--r ~ 2OFF. To exit out of any of the above options, press the MENU button. www.prolight.co.uk RGB Power Batten User Manual 9

DMX setup Setting the DMX address: The DMX mode enables the use of a universal DMX controller. Each fixture requires a start address from 1-512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105 and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the chain starts at 107. DMX 512: DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures (most controllers only have a data out terminal). DMX linking: DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain. DATA cable (DMX cable) requirements (for DMX operation): This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output, see image below. Further DMX cables can be purchased from all good sound and lighting suppliers or Pro Light Concepts dealers. Please quote: CABL10 2m CABL11 5m CABL12 10m Also remember that DMX cable must be daisy chained and cannot be split. www.prolight.co.uk RGB Power Batten User Manual 10

DMX setup Notice: Be sure to follow the diagrams below when making your own cables. Do not connect the cables shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs outer casing. Grounding the shield could cause a short circuit and erratic behaviour. Special note: Line termination: When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behaviour. Using a cable terminator will decrease the possibilities of erratic behaviour. (3-pin - Order ref: CABL9O, 5-pin - Order ref: CABL89) Termination reduces signal transmission problems and interference. it is always advisable to connect a DMX terminal, (resistance 120 Ohm 1/4 W) between pin 2 (DMX-) and pin 3 (DMX+) of the last fixture. 5-pin XLR DMX connectors: Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion. 5-pin XLR (socket) Pin 1: GND (screen) Pin 2: Signal (-) Pin 3: Signal (+) Pin 4: N/C Pin 5: N/C 3-pin XLR (socket) Pin 1: GND (screen) Pin 2: Signal (-) Pin 3: Signal (+) 3-pin XLR (socket) Pin 1: GND (screen) Pin 2: Signal (-) Pin 3: Signal (+) 5-pin XLR (socket) Pin 1: GND (screen) Pin 2: Signal (-) Pin 3: Signal (+) Pin 4: N/C Pin 5: N/C www.prolight.co.uk RGB Power Batten User Manual 11

WEEE notice & Optional accessories Correct Disposal of this Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking shown on the product or its literature, indicates that it should not be disposed of with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal. Please contact your local retailer to purchase these accessories. Optional Twin Case (Holds 2 x fixtures) Order code: CASE29 To keep up-to-date on the latest accessories and product range additions please visit www.prolight.co.uk www.prolight.co.uk RGB Power Batten User Manual 12