SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

Similar documents
Recloser Controller for feeder protection and automation siemens.com/distribution-automation

SIPROTEC 7SC805. Merging Unit for conventional instrument transformer. Products for digital substations.

Products for digital substations SIPROTEC 6MU805. Merging Unit for conventional instrument transformer. Integrated PRP, HSR. siemens.

SIPROTEC 5 Application Note. Breaker-and-a-half solutions. SIP5-APN-002, Edition 2.

Perfect protection smallest space

Perfect protection smallest space

/ sicam SICAM CMIC The smart cube for your distribution network Answers for infrastructure and cities.

SIPROTEC 5 Application Note

SIPROTEC 5 Application Note

Extension of BI/BO for busbar protection SIPROTEC 7SS85

SIPROTEC 5 Application Note

SIPROTEC 5 Application. SIP5-APN-027: Change of switching authority via function keys.

SIPROTEC 5 Application Note

SIPROTEC 5 Application Note

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

SIPROTEC 5 Application Note

A low-cost, economical solution for distribution feeder protection

Siprotec 7ST61 / 7ST63

GE Multilin 350 Feeder Protection Relay Specifications

SIPROTEC 5 Application Note

SIPROTEC Compact Overcurrent Protection 7SJ81 for Low-Power CT and VT Applications

SICAM AK 3. Flexible automation for all applications. Automation, telecontrol and communication for large data volume.

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

SIPROTEC 5 Application Note

SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000

Go beyond... IEC Leverage the full potential with leading-edge expertise. Answers for infrastructure and cities.

Advanced distribution feeder solution with integrated protection, monitoring, and control

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation

Content REF615 Technical Presentation

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations

SIPROTEC 5 Protection, automation, and monitoring

Catalog Edition 6 siemens.com/protection

Products Portfolio. Pole mounted Vacuum Recloser

Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating

SYMAP R Plug in Variants FI, MI, 87M, TI Technical data

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

Easily configurable HMI system for power automation siemens.com/sicam

POWER GRID AUTOMATION. Pág.. n. RMU Automation

SIPROTEC 5 Application Note

SACE Emax 2 Specification guide

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

7SR21 Non-Directional 7SR22 Directional Overcurrent Relay

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

Lightweight and flexible recloser control for single-phase applications

The complete application guide to specifying a Smart-Gear power distribution solution (PDS) E50001-F710-A123-V1-4A00. Answers for energy.

MiCOM P521. Fast feeder differential protection

MiCOM P122C Time-Overcurrent Protection

Lecture 5 Substation Automation Systems. Course map

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830

Numerical motor protection in medium voltage networks Motor Protection and Control REM620

Relion 630 series. Load-shedding controller PML630 High performing load-shedding solution for industrial and utility power networks

Substation Automation Products. Line differential protection RED670 Relion 670 series

Siemens Vacuum Recloser 3AD. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

GPM500 Generator Protection Module

Lecture 6 Substation Automation Systems

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45

7SR18 Solkor Line Differential Protection Energy Management

S&C 6801M Automatic Switch Operator

7SR11 and 7SR12 Argus Overcurrent Relays Answers for infrastructure & cities.

SIPROTEC. Numerical Overhead Contact Line Protection for AC Traction Power Supply 7ST6. Preface. Introduction 1. Functions 2

RELAYABLE POWER. AQ-200 series protection, control, measurement and monitoring IEDs

2 ms arc-flash protection and feeder relay in one platform

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

Electrical Integration with Smart Communication

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Protection, Automation, and Bay Control System. Advanced feeder protection and complete substation bay control in one economical system

Protective Relays & SCADA Systems

SDR recloser. A PH Fault B PH Fault C PH Fault. Ground Fault. SGF Lockout Aux Power OK. Recloser OK

Substation to substation (ss2ss) GOOSE exchange for critical relay operations

SIPROTEC 4 7SJ64 Multifunction Protection Relay with Synchronization

7SR11 & 7SR12 Argus Overcurrent Relay Energy Management

Application Notes on Generator Protection Schemes

7SR11 and 7SR12 Description of Operation

TWO-WINDING TRANSFORMER DIFFERENTIAL

Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation

SIPROTEC Overcurrent Protection 7SJ80. Motor Protection 7SK80. Preface. Content. Data in the PROFINET IO Mapping 1. Standard Mapping

VIP 40/45 VIP 400/410

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Grid Automation Controller COM600 How it fits into the Smart Grid?

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

MiCOM P521. Fast Feeder Differential Protection

Change setting groups via CFC.

Bus Bar Protection Relay B-PRO 4000

Answers for energy. SIPROTEC 5 the new benchmark for protection, automation, and monitoring of transmission grids

High-speed transformer differential protection for up to five terminals

(1) Description of Operation 7SR224 Recloser Controller

Voltage Control of Transformers in Parallel Operation

Protection relays.

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

7SR21 & 7SR22 Argus Overcurrent Relay Energy Management

NPW800R RETROFITTING. Power and Volatge Protection Relay

Automation meets IT. SCALANCE X-500 central interface between Industrial Ethernet and IT networks SIMATIC NET. siemens.

Transcription:

www.siemens.com/protection SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

designed for feeder automation applications This solution allows very fast fault detection and isolation in distribution networks. 1 FLISR (Fault Location, Isolation, and Service Restoration) Fast Source Transfer Load Balancing Fields of application with feeder automation controller 7SC80 Substation B normally open Substation A Circuit-breaker Transformer

overview of the benefits Selective and fast detection via current jump detector Determine the fault location Isolate the faulted section of the feeder Restore service to healthy portions of the feeder Support of feeder automation applications Designed for harsh environment Extended CFC (PLC Programmable Logic Controller) Extended temperature range 50 C up to + 85 C Singlemode module for distances up to 4 km available, multimode for up to 4 km Open for all different communication technologies, e.g. radio, which are used for feeder automation Integrated GPS module for time synchronization and localization Full remote access supported for firmware and parameter updates and upgrades A web-based HMI provides complete remote control of the device Low power consumption Battery Monitoring / Management Basic features USB front interface, Status LEDs, labeled ports Remote control & Upgrade web-based HMI Compact design Detachable HMI IEC 61850, DNP TCP, IEC 60870-5-104, Profinet Pluggable current and voltage terminal blocks

flexible application for medium-voltage power system Description We offer you considerably more than just a simple time-over current protection. The SIPROTEC 7SC80 feeder automation protection device controller can be used for protection and automation of medium-voltage distribution networks with grounded, lowresistance grounded, isolated or a compensated neutral point. The SIPROTEC Compact 7SC80 features flexible protection functions. Up to 0 additional protection functions can be created by the user. Please find the available protection functions in configuration table on page 7. The relay provides circuit-breaker control, further switching devices and automation functions. The integrated programmable logic (CFC) allows the user to add own functions, e.g. for the automation of switch gear (including: interlocking, transfer and load shedding schemes). The user is also allowed to generate user-defined messages. 4

has everything you need for remote operation and control Comprehensive physical and interactive web-based HMI The relay has a physical respectively web-based HMI with LEDs and 9 programmable pushbuttons to configure shortcuts for menu or various applications: Large and well organized display 14 push buttons plus arrow keys configurable LEDs plus operating LEDs Automatic LED and push button labeling Button for LED acknowledgement Open and Close buttons for direct control of equipment Lock push buttons preventing accidental actions With DIGSI 4 and SIGRA 4, you have everything under control Easy configuration of flexible protection functions A matrix instead of nested dialogs means less time-consumption and errors With DIGSI 4, you read all process data from a device and store it centrally With SIGRA 4, you can analyze every network fault 5

function overview Control functions / programmable logic Commands for the control of CB, reclosers, disconnect switches (isolators / isolating switches) Control through keyboard, binary inputs, DIGSI 4 or SCADA system User-defined PLC logic with CFC (e.g. interlocking) Monitoring functions Operational measured values V, I, f Energy metering values Wp, Wq Minimum and maximum values Circuit-breaker wear monitoring Fuse failure monitor 8 oscillographic fault records Trip circuit supervision (74TC) Communication interfaces Ethernet electrical RJ45 Ethernet optical LC multimode up to 4 km Ethernet optical LC singlemode up to 4 km Integrated switch functionality included with protocol options: IEC 61850 Edition 1 and DNP TCP IEC 60870-5-104 Profinet Ethernet redundancy protocols RSTP, PRP and HSR USB front interface for DIGSI 4 FASE and FAST: Convenient engineering and test tool for Feeder Automation Applications Simplified workflow based on device templates Easy & time saving creation and testing of FA apps Automatic configuration of all Feeder Automation related settings No deep CFC and IEC 61850 knowledge necessary Automatic and detailed creation of documentation as PDF S 1 P 01 A P 0 B P 0 C P 04 D P 05 S E P06 S P 07 F P 08 G P 09 H P 10 I P 11 S 4 J P 1 S 5 P 1 K P 14 L P 15 P 16 M P 17 S 6 Hardware 4 current transformers 1 / 4 voltage transformers 1 binary inputs 8 binary outputs 1 live-status contact Pluggable terminals Detachable HMI LPS CTs Product and Order No. FASE Trial FASE Scientific FASE Package 1 FASE Package 5 FASE Package 10 FASE Package 50 FASE Recorder multi-user license keys 7XS5500-1AA50 7XS5500-1AB00 7XS5500-0AA01 7XS5500-0AA05 7XS5500-0AA10 7XS5500-0AA50 7XS5500-0AA00 6

1) only with 100 Mbit Ethernet electrical and multimode ) in preparation ) only with position 7 =, 4 or 6 4) only with position 16 = 0 5) 87N (REF) only with sensitive ground current input (position 7 = 5 or 6) 6) depending on the ground current input, the function will be either sensitive (IEE) or non-sensitive (IE) 7) only with position 1 = 7 Product description Feeder Protection Controller 7SC80 Basic functions Housing, 1 BI, 8 BO, 1 live status contact Specification of CT and VT measuring inputs x I LPS / LoPo, 1 x V 4 x I 1 A / 5 A, 1 x V x I LPS / LoPo, 4 x V 4 x I 1 A / 5 A, 4 x V x I 1 A / 5 A, 1 x Iee (sensitive) = 0.001 to 1.6 A / 0.005 to 8 A, 1 x V x I 1 A / 5 A, 1 x Iee (sensitive) = 0.001 to 1.6 A / 0.005 to 8 A, 4 x V Rated auxiliary voltage DC 60 V to 50 V, AC 115 V, AC 0 V DC 4 V / 48 V DC 4 V / 48 V, Battery Monitoring ) Unit version Surface mounting housing Surface / Flush mounting housing with HMI Surface mounting housing with detached HMI Region-specific default- and language settings Region DE, IEC, language German (language selectable) Region World, IEC / ANSI, language English (language selectable) Region US, ANSI, language US English (language selectable) Region World, IEC / ANSI, language Spanish (language selectable) Region World, IEC / ANSI, language Russian (language selectable) System interface 100 Mbit Ethernet, electrical, x RJ45 connector 100 Mbit Ethernet, with integrated switch, optical, x LC connector multimode 100 Mbit Ethernet, with integrated switch, optical, x LC connector singlemode 4 km Protocol for system interface IEC 61850 IEC 61850 + DNP TCP IEC 61850 + Profinet 1) IEC 61850 + IE C60870-5-104 Additional interfaces No module GPS module Functionality Software packages ANSI No. Base Package A 50 / 51 50N / 51N 50N(s) / 51N(s) 50BF 46 49 87N 74TC 7 51c 86 60CTS 67 67N 67N(s) 7 / 59 81 U / O 5 47 64 / 59N 60VTS / 55 / 81R Additional functions 79 1FL 79 / 1FL 79 / TS 79 / TS / 1FL Time-overcurrent protection phase I>, I>>, I>>>, Ip Time overcurrent protection ground IE >, IE >>, IE >>>, IEp Sensitive ground fault protection IEE >, IEE >>, IEEp 6) Circuit-breaker failure protection Negative sequence / unbalanced load protection Thermal overload protection High impedance REF 5) Trip circuit supervision Undercurrent Cold load pickup Lockout CT supervision Jump detector with Delta measurement, Parameter changeover, Monitoring functions, Control of circuit-breaker, Flexible protection functions (current parameters), Under- / overfrequency, Inrush restraint, Fault recording, average values, min / max values Base Package B (containing A) ) Directional overcurrent protection phase, I>, I>>, IEp Directional overcurrent protection ground, IE>, IE >>, IEp Directional sensitive ground fault protection, IEE>, IEE >>, IEEp 6) Under- / overvoltage Under- / overfrequency, f<, f> Sync check Phase rotation Displacement voltage VT supervision Flexible protection functions (current and voltage parameters) Protective function for voltage, power, power factor, frequency change Base Package N 4) 7) SNTP server functionality, no protection Base Package R 4) Pure RTU functionality, no protection without with autoreclose with fault locator ) with autoreclose and fault locator ) with single / triple pole autoreclose with single / triple pole autoreclose and fault locator ) Order No. 6 7 8 910111 114 1516 7SC80 - -F -L 1 4 5 6 1 A B C A B C E G 9 R 9 S 9 T 0 7 A B N R 0 1 4 5 0 4 7

Publisher and Copyright 01: Siemens AG Infrastructure & Cities Sector Smart Grid Division Energy Automation Humboldtstr. 59 90459 Nuremberg, Germany www.siemens.com/sicam For more information, please contact our Customer Support Center. Phone: +49 180 54 84 7 Fax: +49 180 54 4 71 (Charges depending on the provider) E-mail: support.ic@siemens.com Order No. IC1000-G0-A186-X-4A00 Printed in Germany AL=N ECCN=N Dispo 600 c4bs Nr. 768 HL 1068107 WS 0911.0 09.01, Siemens AG Printed on elementary chlorine-free bleached paper. All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract. For all products using security features of OpenSSL, the following shall apply: This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit. (www.openssl.org) This product includes cryptographic software written by Eric Young. (eay@cryptsoft.com)