Four-channel Venetian blind actuator 230 V Installation Instructions

Similar documents
Operating Instructions

1-channel shutter actuator 6A UP Installation Instructions

KNX/EIB KNX Blind actuator. 1 Safety instructions. 2 Device components. Blind actuator 4-gang 24 V DC Order-No. :

Operating Instructions. DALI-Gateway

Installation Instructions

A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 Controls:

instabus EIB System Actuator

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

Blind actuator 4-gang 230 V AC Order-No

ABB i-bus EIB. Shutter Actuator, 2-fold, 6 A, 230 VAC, MDRC JA/S 2.6.1, GH Q R0111

Electrical devices may only be mounted and connected by electrically skilled persons.

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

Operating Instructions. Power-DALI-Potentiometer

KNX/EIB Push button sensor 3 Plus F Safety instructions. 2 Device components. 3 Function

KNX/EIB Flush-mounted universal dimming actuator 210 W. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

1 Safety instructions. 2 Device components. 3 Function. Control unit 1-10 V, 3-gang. Art.-No.: 2193 REG. Operationsmanual

Product and functional description

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Figure 1: Device components

Product documentation

Product documentation

Product documentation

1 Safety instructions. 2 Device components. 3 Function. DALI Tronic transformer 105 W. Order-No. : Operating instructions

KNX/EIB Intelligent Installation Systems

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product documentation

Switch/shutter actuator 8/4gang 16A RMD Switch/shutter actuator 16/8gang 16A RMD

K-BUS Shutter Actuator. User manual-ver. 1

The LED display (1) turns green when the load is switched on.

6173 AG GJB A0138

Water-protected surface-mounted push-button bus coupler Order No , , ,

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

KNX/EIB Product documentation. Page 1 of 23. Order-No xx Order-No xx Order-No xx Order-No xx

Bus coupler 3 Bus coupler 3 external sensor Order No

KNX/EIB Product documentation. Issue:

1 Safety instructions. 2 Device components. KNX Touch/Glass sensor comfort

Operating instructions only for authorized, skilled electricians with EIB training

Product and functional description

Technische Daten: instabus EIB supply instabus line: YY 6 x 0.6 mm; red: bus (+) / black: bus (-)

DELTA i-system wall switch single UP 221/2 5WG AB_2

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Structure of the device. Push-button sensor module. Ref.-no.: 4008 TSM Safety instructions

ABB i-bus KNX HCC/S Heating/cooling circuit controller

Product documentation. KNX Blind Act.FM w.3 Inputs Art.-No. MTN

Push Button Interface UP 220D31

Product documentation

4-gang and 8-gang switch actuator 16A C-load SE

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

picture 1: Device components

DELTA profil wall switch, single UP 241/2 5WG AB_2

1 Safety instructions. 2 Device components. 3 Function. DALI transformer W. Art.-No.: D SNT 105. Operationsmanual

Product documentation. KNX Blind- a.heating-act.fm w.3 Inputs Art.-No. MEG

Switch Actuator, 4-fold, 16 A, MDRC AT/S , GH Q R0111

The output variables can be force-controlled from a coordinating control system.

Product and functional description

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Product and functional description

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

An optional analog input module, Order no connected to a 6-pole system connector adds four more analog sensors to the device.

The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal.

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties.

picture 1: Device components

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

B.IQ push button comfort 1-4gang, Flush-mounted (Up) x, x, x, x

Data sheet. Function description. Benefits

PanelView Plus/VersaView CE Terminals and Display Modules

Product and functional description

Mounting and Operating Instructions

Docking station Order no Operation and installation instructions. 1 Safety instructions. 2 Structure of the device.

ABB i-bus KNX BCI/S Boiler/Chiller Interface

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Assembly and Operating Instructions. M2 module for BDC-i440 control units

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal rotary dimmer LED

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Speed monitor D / / 2014

Operating Instructions

EAE KNX Room Control Unit Product Manual RCUXXYY

Switch Actuator, 4-fold, 20 A, MDRC AT/S , GH Q R0111

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

KNX DALI Gateway Plus - User Manual

XTM1250SA DIN rail three phase four wire LCD display energy meter

PV Rapid Shutdown device

Product and functional description

Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD

Original operating instructions Safety relay with relay outputs G1501S / / 2016

DALI Professional Controller-4. Control unit Operating instructions

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

SMS 3xxx/SMS 4xxx Safety switch with separate actuator

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Mounting instructions Flush box of Flat Panel PC

ABB i-bus EIB / KNX Shutter Actuator with Manual Operation, 4-fold, SMI, MDRC JA/S 4.SMI.1M. Product Manual. Intelligent Installation Systems ABB

Push button UP 287, 4 - fold

Miniature Circuit Breakers for Railway Applications

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

Technical Manual Room temperature controller

Transcription:

Four-channel Venetian blind actuator 230 V Four-channel Venetian blind actuator 24 V DC Four-channel Shutter actuator 230 V Order no.: 1048 00 Order no.: 1049 00 Order no.: 1050 00 System information This device is a product of the Instabus EIB system and complies with EIBA directives. Detailed technical knowledge obtained in Instabus training courses is a prerequisite to proper understanding. The functionality of this device depends on the software. Detailed information on loadable software and attainable functionality as well as the software itself can be obtained from the manufacturer s product database. Planning, installation and commissioning of the unit is done by means of EIBA-certified software. An updated version of the product database and the technical descriptions is available in the Internet at www.gira.de. Safety Warnings Attention! Electrical equipment must be installed and fitted by qualified electricians only and in strict observance of the relevant accident prevention regulations. To prevent electric shocks, disconnect the mains supply (by cutting out the circuit breaker) before working on the device. Failure to observe any of the installation instructions may cause fire and other hazards. For connection of motors only! Hazards that may be caused by motor-driven components must be exluded by taking appropriate safety measures. Function The 4-channel venetian blind actuators can switch up to four independent blind or shutter drives via the Instabus EIB. Travel commands are triggered by touch sensors or binary inputs of the Instabus EIB system. By means of controls and indicators, the blind/shutter actuators can also be operated comfortably by hand without bus voltage, if they are correspondingly parameterized. This includes also a central stop function by hand for the motors. See the chapters on manual operation. Features 4 independent channels for one blind/shutter motor each 2 x 2 channel operation possible Change-over time for change of travel direction adjustable; observe the instructions of the motor manufacturer! Safety travel during storms independently adjustable for each output Response on failure and return of bus voltage adjustable More features are described in the relevant EIB product documentation. 10/05 Page 1 of 5

Operating information Important If motors are to be connected in parallel, it is indispensable to observe the instructions issued by the motor manufacturers. The motors may otherwise be irreparably damaged. Use only blinds or shutters equipped with limit switches (mechanical or electronic). The limit switches of the motors connected must be checked for correct adjustment. Activation of the manual operating mode terminates all time delays and interrupts the safety travel in the event of storms. The safety travel function will be completed after quitting the manual operating mode. During hand operation, only continuous travel (long press of the button) and stop (brief press of the button) are available. Connection Venetian blind actuator 230 V Shutter actuator 230 V A (Fig. A): The bus line is connected at the bus connecting terminal (1). The supply voltage is connected to terminals N and L (4). Output A1 and motor M1 are then connected automatically to the power supply. For outputs A2 thru A4, a phase conductor must be connected additionally to the respective L-terminals. The diagram shows the connection of motor 2 to output A2. Connection of motors to outputs A3 and A4 is performed in the same way. Legend: (2) hand controls and status indicators (3) LED to indicate the switching state and the output selected in manual operation. 10/05 Page 2 of 5

Venetian blind actuator 24 V DC (Fig. B): The bus line is connected at the bus connecting terminal (1). B The 24 V DC supply is connected to terminals + 1 / 2 (4). Outputs A1 and A2 and motors M1 and M2 are at the same supplied with power. When outputs A3 and A4 are to be used, a 24 V DC supply must additionally be connected to terminals + 3 / 4. Important: Do not connect AC supplies to these terminals! The polarity of the supplies connected to terminals + 1 / 2 and + 3 / 4 must be the same. There is otherwise a risk of irreparable damage to the motors. Connection of motors to outputs A3 and A4 is performed in the same way. Legend: (2) hand controls and status indicators (3) LED to indicate the switching state and the output selected in manual operation. Manual operation The actuators with manual operation can be operated in 3 modes: 1. bus mode (normal operation) 2. continuous manual operation (bus mode deactivated) 3. temporary manual operation (device switches back to bus mode after 5 seconds if no button is pressed) C Operation: A long press (> 5s) on the button (1) activates or deactivates the continuous manual mode, whereas a short press (< 1s) does the same for temporary manual operation (Fig. C). On activation of a manual mode, all channels are switched off. During continuous manual operation, LED (1) lights up. In the manual mode, the switching channel can be selected with the button (1). The pertaining two LEDs (5) start flashing. The remaining LEDs (5) indicate the switching state of the non-selected outputs. Buttons (3) and (4) are the executing control buttons. A long press (> 1s) on the button (4) causes the blind of the selected channel to travel upwards. The button (3) controls the down movement. A short press on the (3) or button (4) stops the blind. After having switched once through all channels in manual operation, the device returns to the bus mode. In the continuous manual mode, the OFF button (2) switches off all relays. 10/05 Page 3 of 5

Cap Slide the cap with the bus wires at the bottom over the bus terminal (fig. D) until it is heard to engage. D To remove the cap, push sideways and withdraw (fig. E). E Technical characteristics Instabus EIB Supply voltage: Power consumption: AC 230 V supply typically: 21-32 V DC typically 150 mw AC 110V~ (-10%) 240V~ (+10%), 50/60 Hz DC 24 V supply typically: DC 24V... ± 10% Instabus EIB connection: Instabus connecting terminal Mains connection: screw terminals 0.5 4 mm² single and stranded wire without ferrule or 0.5 2.5 mm² stranded with ferrule Ambient temperature: -5 C... +45 C Storage temperature: -25 C... +70 C Installation width: 72 mm (4 pitch) Schwitching capacity of outputs AC 230 V typically: 6 A DC 24 V typically: 6 A 10/05 Page 4 of 5

Acceptance of guarantee We accept the guarantee in accordance with the corresponding legal provisions. Please return the unit postage paid to our central service department giving a brief description of the fault: Service Center Dahlienstrasse 12 D-42477 Radevormwald The CE sign is a free trade sign addressed exclusively to the authorities and does not include any warranty of any properties. Postfach 1220 D-42461 Radevormwald Telefon: +49 / 21 95 / 602-0 Telefax: +49 / 21 95 / 602-339 Internet: www.gira.de Acceptance of guarantee We accept the guarantee in accordance with the corresponding legal provisions. Please return the unit postage paid to our central service department giving a brief description of the fault: Service Center Dahlienstrasse 12 D-42477 Radevormwald The CE sign is a free trade sign addressed exclusively to the authorities and does not include any warranty of any properties. Postfach 1220 D-42461 Radevormwald Telefon: +49 / 21 95 / 602-0 Telefax: +49 / 21 95 / 602-339 Internet: www.gira.de 10/05 Page 5 of 5