PROCESS AUTOMATION MANUAL. Temperature Trip Amplifier. KFD2-GU-(Ex)1 ISO9001

Similar documents
PROCESS AUTOMATION MANUAL. Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001

PROCESS AUTOMATION MANUAL. Universal Transmitter Power Supply. KF**-CRG2-(Ex)1.D ISO9001

PROCESS AUTOMATION MANUAL. Temperature Converter. HiC2081, HiD2081, HiD2082 ISO9001

MANUAL Installation and Configuration

PROCESS AUTOMATION. Manual KFD2-UT-EX1 CONVERTER. pepperl_fuchs barriers

MANUAL Functional Safety

MANUAL Functional Safety

MANUAL Functional Safety

PROCESS AUTOMATION PROZESSAUTOMATION HANDBUCH MANUAL FREQUENCY CONVERTER HID2891 ISO9001

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

MANUAL Functional Safety

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

PROCESS AUTOMATION. QUICK START GUIDE FieldConnex Diagnostic Manager

PROCESS AUTOMATION. Manual KF!!-UFT-(EX)2.D ROTATION DIRECTION INDICATOR AND CONSTANT SPEED MONITOR

PROCESS AUTOMATION MANUAL. HART Loop Converter KFD2-HLC-Ex1.D(.**) ISO9001

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

SAFETY MANUAL SIL Switch Amplifier

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

FACTORY AUTOMATION INSTRUCTION MANUAL. AS-Interface Safety at Work VAA-2E-G4-SN. Version 1.2

MANUAL PCV Parameterization Tool

FACTORY AUTOMATION MANUAL ODZ-MAH-B15-M3

ACT20X-(2)HTI-(2)SAO Temperature/mA converter. Safety Manual

MANUAL LML-P, LML-S, LML-Ex

FACTORY AUTOMATION MANUAL WCS-MBG110 WCS MODBUS RTU INTERFACE MODULE

MANUAL Surge Protectors

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

MANUAL HART Multiplexer System

FACTORY AUTOMATION. Manual Speed Monitor KFU8-DW-1.D

FACTORY AUTOMATION MANUAL PMI360DV-F130-IU2E2- V15

SYSTEM DESCRIPTION K-System

PROCESS AUTOMATION. MANUAL H-System. Isolated Barriers and Termination Boards ISO9001

FACTORY AUTOMATION MANUAL PMI360D-F130-IE8-V15 INDUCTIVE POSITIONING SYSTEM

FACTORY AUTOMATION. MANUAL OHV-F230-B17 PROFINET Gateway for OHV Handheld

SYSTEM DESCRIPTION H-System

Temperature Converters

MANUAL Temperature Multi-Input Device

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

QUICK START GUIDE 2-D Laser Scanner

QUICK START GUIDE ODT-HH-MAH300 Handheld

MANUAL/HANDBUCH 2/208

PHOENIX CONTACT - 01/2008

FACTORY AUTOMATION MANUAL VISION CONFIGURATOR

FACTORY AUTOMATION INSTRUCTION MANUAL INDUCTIVE POSITIONING SYSTEM -F90

Operating instructions Evaluation system for flow sensors VS / / 2013

FACTORY AUTOMATION MANUAL MAH* FIRMWARE UPGRADE INSTRUCTIONS

QUICK START GUIDE ODT-MAC40*-*-RD

Electronic Temperature Controller. Instruction Manual Version

QUICK START GUIDE IC-KP2-*

MANUAL MODULAR SEGMENT PROTECTOR

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

FACTORY AUTOMATION. QUICK START GUIDE VBP-HH1-V3.0-V1 AS-Interface Handheld

MANUAL AS-INTERFACE Handheld

MANUAL SEGMENT CHECKER

Interface and Supply module. IPC 3x0i / PSC 3x0i

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

PROCESS AUTOMATION. MANUAL FB Remote I/O System Hardware

FACTORY AUTOMATION INSTRUCTION MANUAL CONTROL UNIT SC4-2

MINI MCR-SL-PT100-UI-200

Operating instructions. Standstill monitor A / / 2011

FACTORY AUTOMATION. QUICK START GUIDE OHV200-F22*-B15 Handheld reader

PROCESS AUTOMATION MANUAL FIELDBUS POWER HUB INVENSYS

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

MINI MCR-SL-PT100-UI(-SP)(-NC)

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

MANUAL WHA-UT-F7B1-0-PP-Z1- Ex2

PI-EX-ME-2NAM/COC-24VDC

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

FACTORY AUTOMATION. MANUAL R CANopen Protocol

MANUAL Encoders with J1939 Interface

Operating Instructions

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

INSTALLATION, OPERATION, CONFIGURATION AND MAINTENANCE MANUAL September/2016 VTT10-PH. HART TEMPERATURE TRANSMITTER panel model

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

PI-EX-ME-2NAM/COC-120VAC

MANUAL HART Multiplexer Master

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2

FACTORY AUTOMATION MANUAL VBP-HH1-V3.0-V1

FACTORY AUTOMATION QUICK START GUIDE IC-KP-*

FACTORY AUTOMATION. Manual IVI-KHD2-4HD1. Control Unit

FACTORY AUTOMATION MANUAL CBX500 HOST INTERFACE MODULES

S900 Remote I/O System Intrinsic safety in the field ABB

TECHNICAL INFORMATION Vibracon LVL-B1, LVL-B2

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Intrinsically Safe Barriers

PHOENIX CONTACT - 12/2007

MANUAL Optical data coupler LS600-DA-IBS

Operating Instructions

FMEDA Report Failure Modes, Effects and Diagnostic Analysis and Proven-in-use -assessment KF**-CRG2-**1.D. Transmitter supply isolator

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Power manual for MACX Analog, MACX Analog Ex, MACX PL, MINI Analog, and MINI Analog Pro signal conditioners. User manual

Operating Instructions Differential Pressure Transducer PS27

PHOENIX CONTACT - 05/2007

Transcription:

PROCESS AUTOMATION MANUAL Temperature Trip Amplifier KFD2-GU-(Ex)1 ISO9001

With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.v.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship"

Table of Contents 1 Symbols Used in this Document.......................... 2 2 Overview.............................................. 2 2.1 Application...................................................... 2 2.2 Versions........................................................ 3 3 Safety Instructions...................................... 4 4 Explosion Protection.................................... 5 5 Mounting and Connection............................... 5 5.1 Mounting....................................................... 5 5.2 Connection...................................................... 6 5.3 Operating and Indicating Elements................................ 8 6 Device Configuration via Software........................ 9 6.1 Connection Between Device and Computer.......................... 9 6.2 Communication Driver........................................... 10 6.3 Monitor Functions.............................................. 11 6.4 Simulation Function............................................ 12 6.5 Diagnosis..................................................... 13 7 Working with Device Data............................... 14 7.1 Menu Information and Description................................. 14 7.2 Menu Parameter Input.......................................... 16 7.3 Menu Parameter Output.......................................... 18 7.4 Switching Behaviour of the Relays................................. 19 1

Symbols Used in this Document 1 Symbols Used in this Document This symbol indicates a warning about a possible danger. Failure to observe this warning may result in personal injury or death, or property damage or destruction. Warning Attention This symbol warns of a possible fault. If the instruction given in this warning is not heeded, the device and any systems or plants connected to it could develop a fault or even fail completely. This symbol brings important information to your attention. Note 2 Overview 2.1 Application The devices of the K-System from Pepperl+Fuchs are used to transmit signals between field devices and the process control system or control. Devices with the "Ex" code in their type identifiers are suitable for connection to field devices in the hazardous area. The field current circuits of these devices are intrinsically safe and are galvanically isolated from the not intrinsically safe circuits. The devices thus represent an electrical isolation between the hazardous area and the safe area within a system. Devices without an "Ex" code can be used for signal transmission between field devices in the safe area and the process control system or the control. 2

Overview The temperature trip amplifier KFD2-GU-(Ex)1 of the K-system are used for temperature measurement. Further information (e. g. certificates, the data sheets for the device and the manual for the K-system) can be found on our Internet page www.pepperlfuchs.com/pa (under product search, enter *GU*). You can connect resistance temperature sensors or thermocouples to the input of the device (types: B, E, J, K, L, N, R, S, T). The device can also process a unit current signal or a unit voltage signal. Two different limit values of the input signal can be monitored with the aid of the two relay outputs on the device and parameters can be set freely for them. You can connect a PC for programming and diagnostics with PACTware (see section 6 and section 7) on the device. 2.2 Versions The following versions of the device are available: KFD2-GU-1, device with a power supply 24 V DC for connection of field devices in the safe area KFD2-GU-Ex1, device with a power supply 24 V DC for connection of field devices in areas exposed to danger of explosion 3

Safety Instructions 3 Safety Instructions The device may only be operated by trained personnel in a manner corresponding to this manual. Warning Warning Protection of operating personnel and the plant is only guaranteed if the device is used according to their specifications. Any use other than that described in the manual endangers the safety and functionality of the device and the connected systems. The device may only be mounted, connected and adjusted by electrical professionals outside the explosion hazardous area. Warning Warning If malfunctions cannot be eliminated, places the device out of service and protect them from accidental use. The device may only be repaired directly by the manufacturer Pepperl+Fuchs. Any opening or change in the device is dangerous and are therefore not to be performed. They void any warranty. Responsibility for adhering to local safety regulations and directives is held by the operator. Note 4

PPPCPPP PPPP P PPION Temperature Trip Amplifier KFD2-GU-(Ex)1 Explosion Protection 4 Explosion Protection MANUAL EXPLOSION PROTECTION Intrinsic Safety Explosion Protection For primary explosion protection, that is, measures to avoid or restrict the production of a dangerous, explosive atmosphere, please consult the ATEX directive or the corresponding national provisions. For secondary explosion protection, that is, measures to avoid the ignition of a surrounding explosive atmosphere by electrical equipment, Pepperl+Fuchs will gladly provide you with a copy of the "Ex-protection manual" for a nominal fee. Please pay particular attention to EN 60079-0, EN 60079-11, and EN 60079-15 or the corresponding national provisions. Pepperl+Fuchs also provides a seminar on the topic of explosion protection. 5 Mounting and Connection 5.1 Mounting Attention The temperature trip amplifier KFD2-GU-(Ex)1 are constructed in protection class IP20 and must therefore be protected from undesirable environmental conditions (water, dust, small foreign objects). The devices of the K-System from Pepperl+Fuchs can be mounted on a 35 mm top-hat rail corresponding to EN 60715. The devices must be snapped onto the rail vertically, and never slanted or tipped to the side. Further mounting alternatives, e. g. using the Power Rail, can be found in the operating instructions for the K-System on our internet page www.pepperl-fuchs.com/pa (under product search, enter *GU*). 5

Mounting and Connection Dimensions of the Table of contents in mm 5.2 Connection The KF series' slip-off terminals significantly simplify connection and construction of switching cabinets. They allow quick and error-free exchange of the unit when service is needed. The terminals can be screwed on, are self-opening, and have generous connection room for a wire diameter of up to 2.5 mm² and coded plugs, so that leads cannot be confused. 6

Mounting and Connection The intrinsically safe field circuit is connected to the blue terminals 1 to 6 of the KFD2-GU-Ex1. The circuit can be directed with interface cable based on EN 60079-14 into the area subject to the danger of explosion. The non-intrinsically safe field circuit is connected to the green terminals 1 to 6 of the KFD2-GU-1. In both cases you can connect: a resistance temperature sensor Pt100 or Ni100 in 2-wire design (terminals 2 and 3) in 3-wire design (terminals 1 to 3) in 4-wire design (terminals 1 to 4) a thermocouple of type B, E, J, K, L, N, R, S, or T (terminals 1 and 2). For an internal cold junction compensation, you will need terminal K-CJC as an accessory instead of the normal terminal 1 to 3. a source for a unit current signal of 0 ma... 20 ma or 4 ma... 20 ma (terminals 2 and 5) a source for a unit voltage signal 0 V... 10 V (terminals 2 and 6) 2-3+ 2-1- 3+ 2-1- 3+ 4+ 2-1+ Thermocouple junction compensation K-CJC 0 ma... 20 ma 2-4 ma... 20 ma 5+ 0 V... 10 V 2-2 V... 10 V 6+ The function of the green terminals 7 to 15 is as follows: terminals 7 to 9: relay 1 terminals 10 to 12: relay 2 terminals 14(+)/15(-): 24 V DC power supply (13 free) For power supply via Power Rail, please refer to the "Interface Technology" catalog of Pepperl+Fuchs. For a detailed account of the terminal assignments, please refer to the data sheet. Relay 1: Relay 2: 7 8 9 10 11 12 7

Mounting and Connection 5.3 Operating and Indicating Elements On the front of the GU you will find: LED OUT1 (yellow) for displaying relay 1 active LED OUT2 (yellow) for displaying relay 2 active LED PWR/FAULT (green/red) for displaying supply voltage present/malfunction Interface for connecting a computer for parameterization and diagnostics of the device with the PACTware TM operating software, using the K-ADP-USB adapter OUT1 OUT2 PWR/FAULT PROGRAM 8

Device Configuration via Software 6 Device Configuration via Software The device is parameterised using the PACTware TM operating software. The PACTware TM operating software and the necessary device and communication DTMs can be downloaded from our internet page www.pepperl-fuchs.com (product search, enter PACTware). The manual "Installation and Configuration DTM Collection Conventional Interface Introduction" guides you through the installation steps necessary to install the software. The manual can be found on our Internet page www.pepperl-fuchs.com (product search, enter PACTware). In the following, you will find the device-specific information for the device. 6.1 Connection Between Device and Computer Connect the device and the computer using the K-ADP-USB adapter. This adapter can be ordered as an accessory. Connecting the device to the computer via the USB interface 1. Mount the device as described in the system description. 2. Connect the device to the power supply as described in the system description. 3. Connect the device to the PC via the adapter with USB interface K-ADP-USB. Connection on the device: front programming socket Connection on the PC: USB interface > The hardware wizard is displayed. Read the note. 4. Follow the installation instructions and confirm the installation steps. > The installation completion window is displayed. 5. Confirm the end of the installation with Finish. > The interface driver is installed. The hardware wizard is displayed only on initial installation or for an update. Note 9

Device Configuration via Software 6.2 Communication Driver In a PACTware TM project, communication with the device is only possible via a communication driver. If your project does not yet contain such a driver, please add it to the project from the device catalogue (see manual). The parameters of the communication DTM is the used PC interface and the number of retries. The parameter is set as follows: Double-click the communication driver with the mouse Select the Communication Port Communication Retries: number of retries the COM DTM attempts to establish communication to the connected device. To add a device to a project, select a communication driver of the project. Then add the device from the device catalogue. Further information on the individual steps can be found in the manual. The description in the following chapters assume that a device has been selected in the project. 10

Device Configuration via Software 6.3 Monitor Functions If you have started the communication between PACTware TM and the device (e. g. via Device data Establish connection), you can open the Measured value window via Device data Measured value. The following information is displayed: Measured value at the input as numerical value and bar graph, displayed in the selected unit. the status off both relays 11

Device Configuration via Software 6.4 Simulation Function If you have started the communication between PACTware TM and the device (e. g. via Device data Establish connection), you can open the Simulation window via Device data Simulation. Warning Simulation interrupts normal functionality of the device! Before starting the simulation, make certain that this cannot result in any dangerous state for the system. The simulation mode is started with the check box Simulation Active. You can assign the status for the two relays for test purposes: de-energised =, energised = Use the check box Simulation Active to end the simulation. The device returns to normal operation. If the power supply is interrupted, the device ends the simulation. The relays assume the assigned status. During the simulation, the red LED on the front of the device flashes. Devices in simulation mode are highlighted in PACTware TM. Note You can close the simulation window with the Close button or by clicking on the Windows-standard button at the top right. The device will remain in simulation mode, however, until the check box Simulation is deactivated. 12

Device Configuration via Software 6.5 Diagnosis If you have started the communication between PACTware TM and the device (e. g. via Device data Establish connection), you can open the Diagnosis window via Device data Diagnosis. It shows the following information: Explanations: Sensor breakage: see section 7.2 Sensor short circuit: only RTD type of sensor; see section 7.2 Overrange, Underrange: measured variable outside the maximum measuring range of the selected sensor (see section 7.2) CJC Error: if the cold junction compensation has been selected (see section 7.2) and a breakage or short circuit occurs within the K-CJC terminal Simulation mode: see section 6.4 13

Working with Device Data 7 Working with Device Data Warning Any change made to the device date will change the functionality of the device! Before transferring new data into the device, make certain that this cannot result in any danger for the system. If you select the PC-programming function for a device in PACTware TM (see manual), a window with menus for parameterization appears, these manues will be described as follows. 7.1 Menu Information and Description The information on the Device info menu is generated automatically or is read from the device. This information cannot be changed on the menu. 14

Working with Device Data You can edit the text on the Description menu as you see fit and save it in the project file. Tag Number Channel 1: freely selectable identification 15

Working with Device Data 7.2 Menu Parameter Input 16

Working with Device Data The following parameters can be set: Sensor: Resistance temperature measurement sensor: Pt100, Ni 00 Thermocouples: T/C type B, T/C type E, T/C type J, T/C type K, T/C type L, T/C type N, T/C type R, T/C type S, T/C type T other: 0...10 V, 0...20 ma, 4...20 ma (NE43) Connection mode (for resistance temperature detectors only, see section 5.2): 2-wire 3-wire 4-wire Unit: for resistance temperature measurement sensors and termocouples: C or K with selection of 0...10 V under sensor: fixed V with selection of 0...20 ma or 4...20 ma (NE43) under sensor: fixed ma The unit selected at this point will be used for all corresponding settings and displays in PACTware TM. Cold junction compensation (for thermocouples only): external (Reference temperature) internal (K-CJC) If you have selected Ext. ref. temp., you can enter the external reference temperature (range of values: -100 C to 100 C) For a internal Cold junction compensation, you require the K-CJC terminal block as an accessory instead of the normal terminal 1 to 3 or 4 to 6 (see section 5.2). Lead Resistance: When connecting an RTD with 2 wire connection the lead resistance of the cabling can be entered numerically if known. 2-Wire Calibration: When connecting an RTD with 2 wire connection the lead resistance of the cabling can be calibrated if the resistance is unknown. For calibration the sensor must be jumpered. Sensor-breakage monitoring (for all types of sensors) Sensor-short-circuit monitoring (for resistance temperature detectors only) Cold junction sensor defective (for thermocouples) Range exceeded (for 0...10 V and 0...20 ma) 17

Working with Device Data Value short of range lower limit (for 0...10 V ) You activate or deactivate monitoring by clicking the respective checkbox ( = selected, = deselected). Firmware Version: Here the Firmware Version of the device can be preselected. Depending on Firmware Version some options and functions can differ. If the Firmware Version is unknown, this can be entered automatically through an upload. 7.3 Menu Parameter Output 18

Working with Device Data The following parameters can be set: Switching point and hysteresis for relay 1 and relay 2; the unit is displayed according to the selection for Parameter Input (see section 7.2). The hysteresis should be selected as > 1 % of the measurement range to avoid causing the relay to flutter. Switching direction (MAX or MIN) and mode of operation (energised or de-energised) for relay 1 and relay 2 The Error Output function for relay 2 is not available until firmware version 3.0. Alarm Freeze: when Alarm Freeze is selected, the Relay State is kept after trip or Fault Alarm until the device is restarted (Power Off-On) 7.4 Switching Behaviour of the Relays Available settings for the switching direction are MIN and MAX; available settings for the mode of operation are energised and de-energised. Range of application (see also figure on page 20): Switching direction MAX, mode of operation energised: Alarm when limit value is exceeded, for example horn on Protection against overheating, for example cooling on Switching direction MAX, mode of operation de-energised: Protection against overheating, for example heater off; with large hysteresis MIN-MAX operation, for example heater on/off Switching direction MIN, mode of operation energised: Alarm when value falls short of lower limit, for example horn on Protection against cooling too cold, for example heater on Switching direction MIN, mode of operation de-energised: Protection against cooling off too cold, for example cooling off; with large hysteresis MIN-MAX operation, for example cooling on/off 19

Working with Device Data Overview of switching behaviour of the relays: Measurment value MAX MAX - hysteresis MIN + hysteresis MIN Switching direction MAX, mode of operation energised: energised de-energised Time Switching direction MAX, mode of operation de-energised: energised de-energised Switching direction MIN, mode of operation energised: energised de-energised Switching direction MIN, mode of operation de-energised: energised de-energised 20

Notes 21

PROCESS AUTOMATION PROTECTING YOUR PROCESS Worldwide Headquarters Pepperl+Fuchs GmbH 68307 Mannheim Germany Tel. +49 621 776-0 E-Mail: info@de.pepperl-fuchs.com For the Pepperl+Fuchs representative closest to you check www.pepperl-fuchs.com/contact www.pepperl-fuchs.com Subject to modifications Copyright PEPPERL+FUCHS Printed in Germany 284503 DOCT-0150D 09/2015