SPECIFICATIONS SYRINGE SAMPLER KZ-31W Higashimotomachi, Kokubunji, Tokyo , Japan. No E Printed in Japan

Similar documents
SPECIFICATIONS. SYRINGE SAMPLER (25 ml syringe version) KZ-30W Higashimotomachi, Kokubunji, Tokyo , Japan

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

Precision pressure indicator 1- or 2-channel version Model CPG2500

High-speed peumatic pressure controller Model CPC3000

Sepacore X10 / X50 system Technical data sheet

Industrial pressure controller Model CPC4000

Pneumatic precision pressure controller Model CPC6000

W-715 Fog Jet USER MANUAL English 2013 Antari Lighting and Effects Ltd.

Keysight U8030 Series Triple-Output DC Power Supplies

DMA 500. Density/Specific Gravity/ Concentration Meter. ::: Unique Density & Concentration Meters

Pneumatic precision pressure controller Model CPC6000

Pneumatic precision pressure controller Model CPC6000

Z-350 FAZER USER MANUAL

TR-7 Series. Network / USB Data Loggers TR-7wf/nw Series Infrared / USB Data Loggers. TR-7Ui Series

FROG-4000TM Quick Start Guide

Pneumatic precision pressure controller Model CPC6000

RD-SDM02 Contact Angle Measurement Instrument. Operation Manual

INSTRUCTION MANUAL Sound Level Meter NL-27

Pneumatic High-Speed Pressure Controller Model CPC3000

INSTRUCTION MANUAL KL-04

Mitos Duo XS-Pump Part No

Z-380 Fazer Machine User Manual English

FT-20 Fire Training Fog Machine User Manual English

Variable Area Flowmeter DATASHEET

SepacoreControl Software data sheet

Stage Fog Machine User Manual

DC100 Digital Dispenser Operating Manual

Portable low-pressure controller Model CPC2000

Quick Start Guide and Health and Safety Information

User s Manual Power Supply IM E. 5th Edition

Universal AC Power Source + AC Power Analyzer

Practical and Compact!

Pneumatic Precision Pressure Controller Model CPC6000

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書

OPERATION MANUAL UCHIDA YOKO CO., LTD., TOKYO, JAPAN US V1.01

LineMaster 100. Continuous-line Recorder. ABB Instrumentation 10/ EN

Discovery SDT650. Site Preparation Guide. Revision A Issued March Page 1

DMA 500. Density/Specific Gravity/ Concentration Meter. ::: Unique Density & Concentration Meters

High-end pressure controller Model CPC8000

icore Kiosk system Installation Guide

Air data test indicator Model CPA2501

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Luminex Prima

Modular pressure controller Model CPC6050

TAM Air Isothermal Calorimeter. Site Preparation Guide

Mitos P-Pump. product datasheet

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

SmartPro 120V 750VA 500W Line-Interactive Sine Wave UPS, Tower, SNMPWEBCARD Option, USB, DB9 Serial

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

Series Pressure Sensor Instruction Sheet

PinAAcle 900 AA Spectrometers

USB pressure transmitter model CPT2500 with model CPA2500 USB adapter and USBsoft2500 software

Technical Specification

INSTRUCTION MANUAL. Sound Calibrator NC Higashimotomachi, Kokubunji, Tokyo , Japan

FT-20 Fire Training Fog Machine User Manual English

SPM Zero dead volume dilutor DATASHEET

Overview INTELLIGEN ULV DISPENSE SYSTEM. Advanced two-stage system enabling superior dispense and filtration of ultra-low viscosity fluids

Customer Responsibilities

LCU-2S Liquid Supply System User Manual English

Waters 600E Multisolvent Delivery System Quick Start Guide

Educational Microfluidic Starter Kit

Circuit diagram. Time ranges. Function. Function diagrams. Notes. Dimension diagram. Page 1

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

ht20 EXAMPLE OF APPLICATION Ethernet www/ ftp / smtp Ethernet TCP IP Ethernet/ internal network 1

Pressure Switch CE40. Digital settings available via IR data communication without actually applying pressure to the unit

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

CLEVELAND CONTROLS MODEL 6650 DIGITAL MANOMETER INSTRUCTION MANUAL DM

Fluke 729 Automatic Pressure Calibrator

Control Motor ECM3000

Technical data sheets

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

Time Counters mini "h", DC Version

INSTRUCTION MANUAL CALIBRATION EXCITER VE Higashimotomachi, Kokubunji, Tokyo , Japan

VC200 Mobile Phone Tester Please Read before Use

Series Pressure Sensor Instruction Sheet

Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar

LCU-1S Liquid Control Unit User Manual English 中文

ANALYTICAL / SEMI-MICRO BALANCES

Rear Cover(CA1-RCVLRG-01) Desktop Stand(CA1-STDLRG-01) Installation Guide

Robe X1 FT PRO USER MANUAL. Version: 1.1. ROBE Lighting s.r.o. Czech Republic

MultiTherm Shaker. Operations Manual Item: H5000-H and H5000-HC

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

User's Guide. Model W 3-in-1 Switching DC Power Supply

2.6 GHz capable, 10 W carrying power (at 2.6 GHz), 50Ω/75Ω impedance and 1 Form C relays

LevelOne KVM User Manual. 17 Modularized KVM Console V

Overview of types. Technical data

FAZE 800 FT PRO USER MANUAL. Version: 1.2. ROBE Lighting s.r.o. Czech Republic

i-hydro 7900 Water Vapor Transmission Rate Testing System

F-712.PM1 Optical Power Meter

DP700 Series. Programmable Linear DC Power Supply. Batter Fly s.r.l. - Tel

High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Classification Enclosure rating Input voltage Type of

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

HIAC Liquid Particle Counting System. Easily configurable for maximum flexibility

Preface. Essential Safety Precautions

SECULIFE IFPRO Infusion Pump Analyzer /7.17

Bartels Micropumps. DE Seite 14

ml/h ml/h ml/h ml/h or off or off )or off

ANALYTICAL/SEMI-MICRO BALANCES

Transcription:

SPECIFICATIONS SYRINGE SAMPLER KZ-31W 3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan No. 14018E 15-07 Printed in Japan

Outline The syringe sampler KZ-31W serves to supply a controlled amount of sample fluid for batch measurement by Rion liquid-borne particle counter. The amount of fluid depends on the operation conditions. Main Functions and Features Choice of three operation modes: purge mode, measurement mode, and combination mode for a preset sequence of purge and measurement operations. Memory for up to 50 sets of operation memory for purge mode or measurement mode. (*) Memory for up to 20 sets of operation memory for combination mode. (*) In measurement mode, selectable blank volume lets sample fluid flow rate stabilize after start of plunger action. Syringe-valve set into which a syringe and valve are integrated, for easy syringe replacement. Selectable from two types: 25mL PP syringe and 25mL glass syringe (option). * When the unit is linked with a computer, operation memory accepts editing, registration, verification and saving by application software KZ-31W Configuration Tool (hereinafter referred to as the application software) on the computer. Half of the operation memory can only be edited or registered by the operating software and will not accept overwriting by the unit. This application software can be downloaded from RION web site (http://www.rion.co.jp/ english) free of charge. A dedicated connection cable (option) is required. Specifications Connectable model Adaptive syringe KE-40B1 25mL PP syringe (polypropylene) 25mL glass syringe (Pylex glass) Materials of parts exposed to sample PTFE, PCTFE, PFA, polypropylene (*) or Pylex glass (*) * Depends on the syringe used. Allowable sample type Fluids which do not cause corrosion of fluid-contacting parts Flow rate tolerance Condition Flow rate 1 to 25 ml/min Sample fluid Pure water Tolerance Within ±5% Operation mode Purge mode Measurement mode Combination mode For purging and replacement of sample fluid system For measurement For purge/measurement sequences 1

Purge mode Sample flow rate/ Drain flow rate Setting range 5 to 100 ml/min (1 to 200 ml/min ) Resolution 1 ml/min Sample volume Setting range 0.0 to 25.0 ml Resolution 0.5 ml Repeat setting 1 to 99 (1 to 999) Measurement mode Sample flow rate/ Drain flow rate Setting range 5 to 100 ml/min (1 to 200 ml/min) Resolution 1 ml/min Sample volume Setting range 0.0 to 25.0 ml Resolution 0.5 ml Blank volume Setting range 0.0 to 10.0 ml (Sample volume + Blank volume 27.5mL) Resolution 0.5 ml Repeat setting 1 to 99 (1 to 999) Combination mode Number of steps 2 to 10 steps Number of memory addresses Purge mode 50 Measurement mode 50 * The range that can be set with the unit alone is from 1 to 25 only. (The range of 26 to 50 can be set when a computer is connected.) Combination mode memory 20 * The range that can be set with the unit alone is from 1 to 10 only. (The range of 11 to 20 can be set when a computer is connected.) 2

External connector Display Operation part EXT CONTROL Serves for connection of the liquid-borne particle counter (KE- 40B1) and a computer. You can read and write operation memory by connecting KZ-31W with a computer. Segment type LCD Serves to display the operation mode, setting values, operation status and other data. Sheet switches Serves for operation mode selection, input of parameter settings, and start/stop control. Environmental Conditions for Operation 5 to 40 C, less than 85% RH (no condensation of internal fluid) Sample Fluid Temperature Range 5 to 40 C Environmental Conditions for Storage -10 to +50 C, less than 85% RH (no freezing of internal fluid) Altitude Up to 2000 m Supply Voltage Fluctuations 100 to 240 V AC10% Overvoltage Category Pollution Degree 2 Power Power consumption Sample fluid pressure 100 to 240 V AC, 50/60 Hz Approx. 50 VA Max. 100 kpa (gauge pressure) Dimensions and Weight Approx. 345 (H) 141 (W) 215 (D) mm (Max.) Approx. 344 (H) 140 (W) 210 (D) mm (Without protruding parts) Approx. 5.5 kg Supplied accessories PFA tube (with connectors) 2 25mL PP syringe set (polypropylene, for exchange) 1 Power cord 1 CD-ROM (instruction manual in English/Japanese) 1 Concise manual (clean paper, in English/Japanese) 1 each Inspection certificate 1 3

Options Connection cable C KZ30S180 * For connection with liquid-borne particle counter (KE-40B1) 25mL PP syringe set (polypropylene, 2-piece set) NW25PP20 25mL glass syringe set (Pylex glass) KZ30WS20 Connection cable for application software KZ31S110 * Application software is available from RION web site by download PFA tube (flared end, with connectors) KZ31S120 * For connection with tube joint of the liquid-borne particle counter Consumables PFA tube, syringe set, valve set 4

Top view (345) 344 140 210 (141) (215) Front view Side view Rear view Dimensional Drawings Unit: mm Specifications subject to change without notice 5