Infilex GC Multipurpose Controller Model WY5311

Similar documents
Infilex GD Multipurpose Data Gathering Panel Model WY5310

Infilex AC AHU Controller Model WY5317C

Infilex GC Multipurpose Controller Model WY5111

SCS (System Core Server) Model BCY44100M

Intelligent Component Series Direct Coupled Damper Actuator Model MY8040A

Infilex AC. Air Handling Unit Controller for NC-bus Communication. Specifications/Instructions. General. Features AB-6438

I/O Modules, User Terminal Module, and SAnet Interface Module

PARAMATRIX 4 Chiller Controller

PARAMATRIX -III Chiller Controller Model WY7400T

(Thermoplate (Auxiliary part))

BACnet Controller for General-purpose Building Applications

Infilex FC. Fan Coil Unit Controller for SC-bus Communication. Specifications/Instructions. Overview. Features AB-6567

Infilex VC Variable Air Volume Controller with Actuator for SC-bus Communication

Advanced Remote I/O Module

Infilex VC Variable Air Volume Controller with Actuator for BACnet MS/TP Communication

Infilex FC Fan Coil Unit Controller

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Product and functional description

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Operating instructions. Switching amplifier DN0210 DN / / 2015

MODEL: R2K-1 SEN TRONIC AG. R2K Series

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Operating instructions. Speed monitor D / / 2014

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

F1000 User's Manual. (Version: V1.01)

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

BACnet/IP Web Interface

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

PXR11 PXR12. System controllers DESIGO PX

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

LON Module for Variable Speed Drive

Extension module for lighting control

Type ME43. Quickstart

DC I/O Conversion Module FA-TB32XY

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

User Manual. MS657208X Industrial Gigabit Ethernet Switch 8x 10/100/1000Base-T

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

TAC Xenta 301. Controller, Freely Programmable

User's Guide. Model W 3-in-1 Switching DC Power Supply

Product and functional description

Operating and mounting instructions

Communication & Networking

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Hard Disk Unit for PC CPU Module Compatible with MELSEC-Q Series PPC-HDD(MS)A User s Guide

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

4170 POS System Installation Guide

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

9000C INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

TM3TM3 module TM3-2 temperature inputs and 1 analog output

TM3TI4 module TM3-4 inputs temperature

KIEN2204S Industrial Ethernet Switch Hardware Installation Manual

Digital input modules

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

INTELLIGENT SERVER. Model: BMS-LSV6E

DC I/O Conversion Module

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

MC 11 EB-2 Power supply cabinet with external bus, AC version

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

EX-RC1 Remote I/O Adapter

584 5WG AB_1 DELTA

EL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Operating instructions. Standstill monitor A / / 2011

Operating Instructions VEGAMET 381

Non-communicating room controllers

Expansion Module HZS 541-1S

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

TXM1.8RB. TX-I/O Blinds module

LOCAL DISPLAY UNIT (LDU)

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Modicon Premium PLCs TSX CSY 84 / 85 / 164

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

MINI-PS AC/10-15DC/8

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

Building Management System. (Version or later)

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Transcription:

Specifications/Instructions Infilex GC Multipurpose Controller Model WY5311 General Infilex GC (Infilex: named for Infinity and Flexible ) Model WY5311 is a multipurpose controller designed to control building equipment, such as air handling unit (AHU). Infilex GC enables to control the temperature and humidity, as well as building equipment operation. Infilex GC can be operated with a user terminal and with Operator Panel. Besides, Infilex GC can communicate with BMS (building management system) Azbil Corporation s savic-net FX via LonTalk protocol. By sending the operation status to the main control unit (monitoring computer) and by controlling the operation based on the commands sent from the main control unit, the integrated control of the entire building can be executed. Infilex GC consists of a basic unit and connectable I/O modules (and a user interface module). The number and types of the modules can be flexibly changed corresponding to the control or management to fit in various applications. Additionally, since the software to be installed can be freely edited, an optimum application for building equipment can be configured in terms of both the software and hardware. Features Compact design: Small size body allows free installation in a desired place. Various input/output (I/O) configurations: Input and output types can be selected, and the number of points to be mounted can be increased or decreased corresponding to the application. Editable software configurations: Optimal software for the contents of the application can be configured. User interface module (Operator Panel): Operator Panel (panel mount type/integral type) connected to Infilex GC allows you, without changing the settings from the BMS center unit, to change the Infilex GC settings. Remote control with a user terminal: Neopanel or Neoplate is connectable, so that a user at a remote location can perform ON/OFF operation and change temperature setting. Autonomous distributed control: Even if a trouble occurs in the BMS, the backup operation is performed individually to distribute potential risks caused by malfunction of the system. Installation: A quick-fit screwless (clamp) terminal block is used for the communication terminal block of the I/O module, ensuring the labor saving of the wiring work. Additionally, either DIN rail mounting or screw mounting can be selected. LONMARK certified product: Infilex GC is LONMARK certified and thus interoperable integrated in the LONWORKS system. CE Marking certified product: Infilex GC conforms to all the applicable standards of CE Marking (Class A). Azbil Corporation s Infilex series controllers: Infilex is named for Infinity and Flexible. 1

Safety Instructions Please read instructions carefully and use the product as specified in this manual. Be sure to keep this manual near by for ready reference. Usage Restrictions This product is targeted for general air conditioning. Do not use this product in a situation where human life may be affected. If this product is used in a clean room or a place where reliability or control accuracy is particularly required, please contact Azbil Corporation s sales representative. Azbil Corporation will not bear any responsibility for the results produced by the operators. WARNING DANGER: To prevent the risk of severe or fatal electrical shock, always disconnect power source and product power supply before performing any wiring. Be sure to ground with 100 Ω or lower ground resistance. Improper grounding may cause electrical shock or equipment damages. Do not detach the terminal cover at any time except when wiring. After wiring, be sure to attach the terminal cover. Before attaching/detaching the terminal cover, make sure that the wires are not current-carrying to prevent electrical shock. Disconnect power before the product replacement to prevent electrical shock. Do not disassemble the product. Disassembly may result in electrical shock or equipment damage. CAUTION Installation and wiring must be performed by qualified personnel in accordance with all applicable safety standards. This product must be operated under the operating conditions (power, temperature, humidity, vibration, shock, installation position, atmospheric condition, etc) specified in this manual to prevent equipment damages. All wiring must comply with local codes of indoor wiring and electric installation rules. Use crimp terminal lugs with insulation for electric wires connected to the screw terminals. Connect cables to the power source with terminals or the like for permanent connection. Make sure all the wires are tightly connected to prevent heat generation or equipment damages. If more than the rated power supply voltage is applied, product replacement is required for safety. Install this product in a location out of reach of unauthorized people. (e.g. Inside of the control panel cabinet) Lightning protection based on regional characteristics and building structure is needed in order to minimize lightning damages. Noise protection is necessary when the product is installed in a location close to many noise sources. Do not block the vent holes of the product to prevent equipment damages. Remove protective sheet after installation and wiring. After mounting the product on DIN rail, make sure that the holding parts of all the modules are properly fixed with their whole parts lifted. The product may drop from the DIN rail and be damaged due to improper mounting. Do not plug in or out I/O modules or user interface modules with the product power turned on to prevent equipment damages. Dispose of the lithium battery in accordance with your local regulations. Dispose of this product in accordance with your local regulations. Do not reuse all or part of this product. Trademark information: Infilex, Neopanel, PARAMATRIX and savic-net are trademarks or registered trademarks of Azbil Corporation in Japan or in other countries. BACnet is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). CompactFlash is a U.S. registered trademark of SanDisk Corporation. KPEV is a registered trademark of Furukawa Electric Co., Ltd. LONMARK, LonTalk, and LONWORKS are trademarks of Echelon Corporation registered in the United States and other countries. 2

System Configurations Infilex GC integrated into BMS: savic-net FX MIS SMS DSS Client PC (with Web browser) BACnet IP SCS LC-bus (LonTalk protocol) Infilex AC Model WY5317C DSS: Data Storage MIS: Management Integration Server PMX-III: PARAMATRIX -III SCS: System Core Server SMS: System Management Server Infilex GC Model WY5311 Neopanel Model QY7205 (Digital user terminal) Infilex GD Model WY5310 Neoplate Model QY7290 (Analog user terminal) Infilex ZM Model WY5322 LS-bus (LonTalk protocol) PMX-III* 3 Model WY7400 Infilex SC Model WY5307 Infilex FC Model WY5305 Infilex VC Model WY5306 Figure 1. System configuration example of BMS-integrated Infilex GC Notes: MIS may be used instead of SMS and DSS for your system. Note that MIS cannot be mixed with SMS or DSS in the same system. On 1 channel of LC-bus (2 lines for 1 channel), max. 50 remote units (also called controllers ) can be connected. For Infilex ZM, however, max. 10 units can be connected on LC-bus (5 units per 1 line, 2 lines for 1 channel). Max. wiring length of LC-bus (2 lines for 1 channel) is 900 m. On LS-bus, max. 50 remote units (also called sub-controllers ) can be connected. Max. wiring length of LS-bus is 900 m. Standalone Infilex GC Neopanel (Digital user terminal) Neopanel (Digital user terminal) Temperature sensor LonTalk protocol Infilex GC Model WY5311 Infilex AC Model WY5317C Infilex ZM Model WY5322 LS-bus (LonTalk protocol) Infilex VC Model WY5306 Infilex FC Model WY5305 Infilex VC Model WY5306 Neopanel Neoplate (Digital user terminal) (Analog user terminal) Figure 2. System configuration example of standalone Infilex GC Notes: On LS-bus, max. 50 controllers can be connected. Max. wiring length of LS-bus is 900 m. 3

Model Numbers Model number Description WY5311 Base model number W 100 V AC to 240 V AC power 0000 Fixed Notes: For I/O modules and user interface modules (UT module and integral type Operator Panel) to be combined with Infilex GC Model WY5311, separate order is required. Regarding I/O modules user interface modules to be combined with Model WY5311, refer to AB-6527 Specifications/Instructions of Model RY50XX. Parts for Installation For details regarding Infilex GC installation, refer to Installation manual of the Infilex series controllers Part number Description 83165861-001 Screw tab 83104567-001 DIN rail mounting bracket Note: For mounting Infilex GC, either the screw tab (for screw mounting) or the DIN rail mounting bracket (for DIN rail mounting) is required. Be sure to separately order depending on your mounting type. 4

Specifications Basic specifications Power supply Environmental conditions LED indication Power failure backup Communications Item Rated operating conditions Transport/storag e conditions Operation Rated voltage Allowable voltage range Power shutdown detection Specification 100 V AC to 240 V AC, 50 Hz/60 Hz 85 V AC to 264 V AC, 50 Hz/60 Hz 80 V AC or less Power consumption 40 VA Ambient temperature 0 C to 50 C Ambient humidity 10 %RH to 90 %RH (non-condensing) Altitude 2000 m or lower Vibration Max. 3.2 m/s 2 at 10 Hz to 150 Hz Ambient temperature -20 C to 60 C Ambient humidity 5 %RH to 95 %RH (non-condensing) Vibration for storage Max. 3.2 m/s 2 at 10 Hz to 150 Hz Vibration for transportation Max. 9.8 m/s 2 at 10 Hz to 150 Hz Power supply (POWER) Green LED ON: Power ON Green LED OFF: Power OFF Major failure (ERR1) Red LED ON: Major failure or system restart Red LED OFF: Normal operation Minor failure (ERR2) Red LED ON: Minor failure or system restart Red LED OFF: Normal operation Communication LC-bus TX: Transmit, RX: Receive, SERV: Service LC-bus Weight Material (housing), color Terminals connection RAM, RTC* Data file Transmission system Transmission speed Transmission distance Remote units Power supply, ground LC-bus communication Lithium battery backup Non-volatile memory (flash memory) backup LonTalk protocol (TP/FT-10 transceiver) 78 kbps 900 m (for bus topology connection) Max. 50 remote units connectable 400 g Modified PPE, light gray M3 (7.62 mm pitch between terminals) Modular connector Note: RTC: Real Time Clock. RTC is backed up by a lithium battery to ensure accurate clocking while the power is OFF. Wiring specifications Basic unit Item Wiring* 1 Wiring length Condition Power supply* 2 JIS* 3 IV2.0 mm 2 or JIS CVV 2.0 mm 2 or greater Ground* 2 JIS IV 2.0 mm 2 or JIS CVV 2.0 mm 2 or greater Ground resistance: 100 Ω or lower LC-bus EIA/TIA-568 category 5 or over (φ0.5 4 poles) 900 m For bus network topology Notes 1 Pin terminal is not applicable to wiring of Infilex GC. 2 M3 screw terminal block is provided for wiring of power supply and ground. Be sure to crimp the crimp terminal lugs on the wire ends. 3 JIS: Japanese Industrial Standards 5

I/O module Item Wiring Wiring length Temperature input JIS IV, JIS CVV, KPEV * 1.25 mm 2 100 m Voltage/Current input JIS IV, JIS CVV, KPEV 1.25 mm 2 100 m Voltage/Current output JIS IV, JIS CVV, KPEV 0.9 mm 2, 1.25mm 2 100 m Modutrol motor output JIS IV, JIS CVV, KPEV 1.25 mm 2 100 m Digital input JIS IV, JIS CVV, KPEV 0.5 mm 2, 0.75 mm 2, 0.9 mm 2, 1.25 mm 2 100 m Relay output JIS IV, JIS CVV, KPEV 1.25 mm 2 100 m Remote control relay output JIS IV, JIS CVV, KPEV 1.25 mm 2 100 m Notes: Since a quick-fit screwless terminal block is provided on I/O modules, the wires can be connected only by stripping the sheath. Sheath stripped length: 8 mm (Pin terminal cannot be used.) KPEV is a wiring standard provided by Furukawa Electric Co., Ltd. Specifications of I/O modules, user interface modules, and Operator Panel For the specifications of I/O modules and user interface modules, refer to Specifications/Instructions of Model RY50XX (AB-6527). For the specifications of Operator Panel (integral type / panel mount type), refer to Specifications/Instructions of Model RY5001Q/QY5100W (AB-6546). CE Marking Conformity This product must be installed in a panel cabinet. Besides, the product in the panel cabinet must be out of reach of unauthorized people who are not well-trained for electric facilities. This product complies with the following Electromagnetic Compatibility (EMC) and the Low Voltage Directive (LVD). EMC : EN61326-1 Class A, Table 2 (For use in an industrial electromagnetic environment) LVD : EN61010-1 Overvoltage category II Pollution degree 2 Input/Output Terminal Arrangement 100-240 V AC 1 2 3 4 CONF. IN RJ-45 modular connector LC-bus OUT Figure 3. Input/output terminal arrangement 6

Dimensions 60 90 140 Figure 4. Dimensions (mm) 7

Parts Identification LED for operating status Power switch S1 switch* Do not press the S1 switch. LED for power ON/OFF Battery holder DIN rail mounting hook Indication tag Figure 5. Parts identification LED indication Data transmitting Data receiving In SERVICE mode Major alarm / initializing Minor alarm / initializing Table 1. Indication and operation of operating status LED LED operation LC-bus TX LED: flashing LC-bus RX LED: flashing SERV LED: ON (See Table 2 for SERV LED operation.) ERR1: ON ERR2: ON Normal Table 2. Indication and operation of SERV LED Status LED indication ( : ON / : OFF) Normal Applicationless Appli-less 3 sec Unconfigured Unconfig 1 sec 1 sec LS-bus error Any indication other than the above. 8

Connection of Data Setter for LonTalk Protocol Connect the CompactFlash memory type Data Setter (Model QY5111B) for LonTalk protocol to LC-bus port or to CONF. port of Infilex GC with the Data Setter adaptor (Part No. DY5301S0000, with separate order required.). For details of the Data Setter adaptor, refer to its Specifications manual. LC-bus (LonTalk protocol) Data Setter adaptor Model DY5301S Data Setter Model QY5111B (For setting Infilex GC and other remote units connected on both LC-bus and LS-bus: Connect Data Setter with Data Setter adaptor to LC-bus port or CONF. port of Infilex GC.) Infilex GC Model WY5311 Infilex GD Model WY5310 Infilex AC Model WY5317 Infilex ZM Model WY5322 LS-bus (LonTalk protocol) Infilex SC Model WY5307 Infilex FC Model WY5305 Infilex VC Model WY5306 Figure 6. Connection example of Data Setter with Data setter adaptor to LC-bus port/conf. port 9

Maintenance (Lithium Battery Replacement) Replace the lithium battery for backup (Part No. 83104934-001) for every 5 years. IMPORTANT: Since the remaining battery capacity cannot be checked by measuring the terminal voltage, be sure to replace the battery every 5 years. Only authorized service personnel is allowed to replace the battery. Do not touch the power supply unit when replaceing the battery. Replace the lithium battery every 5 years if the product is always in use (in ON state). Replace the lithium battery with the power ON. If the product has never or hardly been operated (in OFF state) for a year, replace the lithium battery before the product operation. Battery replacement 1) Lithium battery for backup 2) 4) Battery holder 3) Infilex GC basic unit Battery connector 5) Replace the lithium battery with Infilex GC in ON state. Figure 7. Battery replacement 1) Pull out the battery holder using a slotted screwdriver. 2) Disconnect the battery connector and detach the lithium battery from the battery holder. 3) Place a new lithium battery in the battery holder and connect the battery connector to it. 4) Insert the battery holder into the main body. 5) Fill in the date for next replacement (5 years after the replacement) on the indication tag using an oil-based pen. 10

Precautions for Use Do not mount the product under the conditions of high temperature and humidity. Be sure not to drop the product. Be sure to shut down the power (disconnect the wiring between the power supply and the product power terminals) for the wire replacement. Before turning on the power, make sure that wires are correctly connected. Do not connect wires to vacant terminals. Several tens of seconds are required for the product normal operation after the power is turned on. During this time, the ERR1 LED (red) for major alarm lights up temporarily, but this does not indicate an error. Leave at least 35 mm clearance between the top/bottom surfaces of the product and other devices. Peel off the protective sheet on the top surface of the product before turning on the power. (See Fig. 8.) For LONMARK network variables, see AB-6824 LONMARK Functional Profile: Open-Loop Actuator. Protective sheet Battery label on the indication tag Figure 8. Battery label and protective sheet 11

Specifications are subject to change without notice. Building Systems Company http://www.azbil.com/ Rev. 4.0 Sep. 2015 (J: AI-6580 Rev. 3.1) 12 AB-6580 H (W03) Printed in Japan.