TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

Similar documents
TRP-C08S. USB to 1 RS232 and 1 RS422/485 Isolated Converter. User s Manual

User s Manual Printed Sep Rev 1.2

TRP-C08X. USB To 4 RS232/422/485 Converter. User s Manual

TRP-C08 User s Manual

TRP-C06H User s Manual

TRP-C07 User s Manual

TRP-C08S. USB To 1* RS232 and 1*RS422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.2

TRP-C08M. USB To 4 RS232/422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.0

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3

TRP-C41 User s Manual

User s Manual INT131

SCB-C08 USB to RS232/422/485 Converter

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed September Rev 1.6

TRP-C37 User s Manual

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

USB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual

TRP-C37M User s Manual

TRP-C37M User s Manual

TRP-C34H. Ethernet to 4 RS232/422/485 Converter. User s Manual. Printed Sep Rev 1.1

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

3.1 I-7560 Pin Assignment and Specifications: Introduction

PCI Express 4-Port Industrial Serial I/O Cards

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

converter Tel: Fax:

USB to RS-422 / 485. US USB To Serial Operation Manual

PCI Express 16-Port Serial I/O Cards

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

Tel: Fax:

USB Serial Converter Rev. 1.0

8S RS232/422/485 Combo to USB2.0 Module Box Installation Guide

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US

SER-4485-SI-M USER S MANUAL

Commercial-grade Interface Converter User Manual

Forcom Technology Co., Ltd. Intelligent RS-485/422 to RS-232 converter

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

Produkt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an. Kontakt

CyberX Industrial Serial Media Converter Quick Installation Guide

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

MEC-COM-M134. User s Manual

USB-COM Plus ISO (USB-COMi SI-M)

User Manual A08. User Manual

Serial to Ethernet Converter

Moxa TCC-100 Series User s Guide

General Operating, Maintenance and Installation Manual

Installation Guide of Hi-Speed USB to Industrial I/O Adapter

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

USB-4COM RJ45. Contact Online. More Pictures. Click on the thumbnails for the large picture. Overview

Product Manual. USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset. Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

Data Acquisition. CM 7000 Series. Family of Bus Converter & Repeaters

TRP-C24 User's Manual

Installation Guide of Hi-Speed USB to Industrial Single RS-422/485 Adapter

Introduction & Specifications of Hi-Speed USB to Serial Adapters

Industrial Serial Device Server

PCIe-400 USER S MANUAL

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

ES-313 ETHERNET TO SERIAL DEVICE SERVER Ethernet 2 Port RS422/485

TRP-C28 User s Manual

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

Product Manual. 2 Port USB to RS-422 /485 Optical Isolated Adapter. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-2COMi-Si-M

Moxa TCC-100 Series Hardware Installation Guide

8 Channel USB to RS485/422 Converter USB-402 User s Manual Ver. 1.0 HuMANDATA LTD.

MED102A. Industrial Serial to Single-mode Fiber Converter

Introduction & Specifications of Hi-Speed USB to Industrial Dual Ports RS-422/485 Adapter

IDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool

LM058 Bluetooth v2.0, v2.1 RS232 Serial Adapter - SMA Connector Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack)

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

USB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual. Features and Specifications. Power Supply

Installation Guide of Hi-Speed USB-to-Optically Isolated RS-422/485 Adapter

EX & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card

RS-422A/485 Serial I/O Board with Isolation for PCI. Features. Cable & Connector (Option) Product Configuration List.

USB-2COM-BB USER S MANUAL

TRP-C channel Digital Input Isolated RS485 Module, Support ASCII and Modbus Protocol. User s Manual. Printed APR Rev 1.

Korenix JetCard Series Multiport Serial Card/Ethernet Switch Card User s Manual

Serial to Ethernet Converter HL-SE02P-V1. User s Manual V3.606

This 4-port RS-422/485 Adapter is provided with an external switching power adapter in the package.

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

IM3523 IM3533 IM IM3536 LCR METER IM3570 IM7580 IM3590 CHEMICAL IMPEDANCE ANALYZER IMPEDANCE ANALYZER. Communication Instruction Manual

i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products

ZLAN5443A. User Manual

4-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection

MEC-COM-M154. User s Manual

1 to 16-port RS-232, RS-422/485, and RS-232/422/485 USB-to-serial converters. Features and Benefits. Certifications

Hardware Manual. PCMCIA 1 Port RS EDITION APRIL 1999

The 7000 Series Bus Converter

Bluetooth TO Serial CONVERTER E-P132-B

Sender Receiver Sender

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M

SST-2450 Wireless Modem User s Manual

TRP-C28. 4-channel isolated digital input and 4-channel power relay output RS485 module, Support ASCII and Modbus Protocol.

LM048 Bluetooth v2.0, v2.1 RS232 Serial Adapter Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack)

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

8-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection

Product Manual. Mini USB to Terminal RS422 RS485 FTDI Plug-in Adapter. Coolgear, Inc. Version 1.1 April 2018 Model Number: USBG-422MiNi

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

Bluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual

Industrial Quad-band GPRS/GSM Modem GTM-201 Series. User Manual

Transcription:

TRP-C08 USB to RS232/422/485 Isolated Converter User s Manual Printed Sep.2014 Rev 1.4 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351 Fax: 886-3-350-3352 Web: www.trycom.com.tw Copyright Copyright Notice: The information in this manual is subject to change without notice to improve reliability, design and function and does not represent a commitment on the part manufacturer. No part of this manual may be reproduced, copied, or transmitted in any form, without prior written permission by the manufacturer. Products mentioned in this manual are mentioned for identification purposes only. In this manual, product names appearing may or may not be registered trademarks of their respective companies or copyright.

1. Introduction The TRP-C08 allows you to connect your serial devices to systems by using a USB interface. With auto configuration in data format, baud rate and RS485 data flow direction control. TRP-C08 is able to automatically configure RS232, RS422 or RS485 signals to baud rate without external switch setting. TRP-C08 is equipped with 3000V DC of isolation and internal surge-protection on each data lines to protect the host computer and converter against high voltage spikes, as well as ground potential difference. TRP-C08 also features a high-speed 256 Kb/s transmission rate, and supports various O.S. The industry DIN rail and panel mounting design enable user a fast and professional installation. 1.1. Features Full compliance with the USB V1.0 and 2.0 specification. System gets 1 COM port when the converter is connected. Auto data format detecting. Auto direction flow control on RS485. Auto baud rate switching from 75 bps to 6M bps. 256 byte buffer for upstream and downstream data flow. Direct power from USB port, no external power necessary. 3000V DC isolated protection. Surge protection on RS422/485 data lines. Power/TX/RX mode LED indicator. DIN rail or panel mount support. Driver support: WIN8/WIN7/WIN98/ME/2000/XP/CE3.0, and Linux, and Mac OS. 1-2. Specifications USB interface: Fully compliant with V1.0, 2.0 specifications. USB to serial bridge controller; Prolific PL2303 Series. RS232 signal: 5 full-duplex (TXD, RXD, CTS, RTS, GND). RS422 signal: Differential 4 full-duplex wires (TX+, RX+, TX-, RX-). RS485 signal: Differential 2 half-duplex wires (D+, D-). Data Format: Asynchronous data with all common combination of bits, parity, stop. Parity type: None, odd, even mark, space. Data bit: 5, 6, 7, 8. Stop bits: 1, 1.5, 2. Cable: USB type A to type B. Communication speed: form 75bps to 6M bps. RS422/485 line protection: Against surge, short circuit, and voltage peak. Transmission distance: RS422/485 Up to 4000ft (1200M). Connection type: Screw terminal accepts AWG #12~30 wires. Signal LED: Power on, TX, RX.

Direct power from USB port. Power consumption: 1.2W. Isolation voltage: 3000V DC. Operating environment: 0 to 60. Storage temperature: -20 to 70. Humidity: 10-90% non-condensing. Dimension: 151mm X 75mm X 26mm. Weight: 375g. 2. Hardware Description 2-1. Panel layout

2-2. Block diagram 2-3. LED Indictor 1PWR LED: System is ready. RX LED: RS232/422/485 Receiving. TX LED: RS232/422/485 Transmitting. 23. Install TRP-C08 13-1. Power Connection (USB Internal Bus) Direct power input from USB bus port, current 100mA/+5V, no external power necessary. 13-2. USB Connection TRP-C08 use the standard A to B type USB cable between host and converter. 3-3. RS232 wiring connection The RS232 supports 5 channels plus Signal Ground and is configured as DTE like a computer. Signals are single ended and referred to Ground. To use handshaking or flow control user must set Host PC s RTS/CTS during configuration. Refer to the pin assignment for connection as below.

2-6. RS485 Wiring connection The RS485 mode supports the Transmit and Receive channels using 2-wire half-duplex operation. Refer to the pin assignment for connection as below. 2-7. RS422 wiring connection The RS422 mode supports 4 channels with full duplex operation for Receive, Transmit, The data lines are in differential pairs. Refer to the pin assignment for connection as below. Notice: Due to the Hardware control problem will caused TRP-C08 under RS422/485 can't work, please take TRP-C08's RS232 screw terminal connector (RTS & CTS SHORT).

3. TRP-C08 Software Installation 1. Power on your computer and boot to Windows. 2. Install PL-2303 driver (See figure1, 2) User may find the TRP-C08 PL2303 Driver Installer in Trycom support CD or download from Trycom web www.trycom.com.tw. Step1. Double click PL2303 Driver Installer the installshield Wizard screen will appear. The Wizard will guide you to complete the installation. Step2. Connect TRP-C08 with your computer by USB cable. Step3. Windows system will auto detect a new USB devices" and complete TRP-C08 installation

. 5.After installation user may verify if TRP-C08 was properly installed by Click Start Setting -Control panel -- double click system icon Hardware Device Manager -- Double click on ports (COM&LPT).(See Figure 4) Fig.4 6. If the device was correctly installed you may see new COM devices listing. This means Windows has assigned the device to the COM# port. *It could be difference COM port show on the windows Device Manager, The PL2303 driver will auto assigned COM number on your system.

4. Remove or update TRP-C08 Driver It is necessary to update the driver when TRP-C08 adds new features or function. User may download the latest driver from Trycom web www.trycom.com.tw. Use the DRemover98_2k to remove old version TRP-C08 driver. Double click DRemover98_2k If an older version of the TRP-C08 driver software existed in the system, the modify, repair or remove the program window will appear, select Remove to clean TRP-C08 driver completely. Once the software has been removed, install the new software. 5. How to test TRP-C08 Trycom Technology Co.,Ltd offers test utility, this is utilities may help user to demo and test TRP-C08 fast and easily. User may find the utilities in Trycom support CD or download from Trycom web www.trycom.com.tw, direct to perform TRPCOM.exe from the directory. 5-1.RS232 Loop Back Test RS232 loop back test wiring connection.

5-2.RS422 Loop Back Test RS422 loop back test wiring connection. 5-3.Loop Back Test Software STEP1: Run the TRPCOM.EXE utility. STEP2: Click the Setting to set the com port and baud rate then press OK. *Please note: COM2 is an example of COM port number; the real COM number is assigned by user PC. STEP3:. Click the "Terminal" then select Loop back enable, the counter value and pass value will be synchronized counts.

5-4. RS485 test RS485 test mode, it can be connected to RS485 Device, such as connecting TRP-C28, send "$01M" instruction from the client side, when the TRP-C28 received command that will response "!01TRPC28" indicates execution completed. Step1. Run TRPCOM.exe utility. Step2. Click the Setting to set the com port and baud rate then press OK.

Step3.Send command $01M and press Send button. Step4. TRP-C28 response received.

6. TRP-C08 Application.