DeltaV SX Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy to use. Field proven architecture

Similar documents
DeltaV SQ Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy-to-use. Field proven architecture

DeltaV SX Controller. DeltaV SX Controller. Introduction. DeltaV Product Data Sheet. Scalable controllers. Quick Assembly.

DeltaV SD Plus Controller

DeltaV MX Controller. Introduction. Benefits. Right-sized controllers. Easy to use. Has the flexibility to meet your needs

DeltaV MQ Controller. Introduction. Benefits. Increases productivity. Easy to use. Has the flexibility to meet your needs. Increases productivity

M-series MX Controller

M-series MQ Controller

S-series Horizontal Carriers

DeltaV PK Controller. Benefits. Introduction. Powerful Standalone. Easily Integrated. Fast process control applications

S-series Foundation Fieldbus I/O

Introduction. Delivers four ports to provide increased input/ output per card. Takes advantage of all smart device capabilities

Introduction. DeltaV Product Data Sheet February 2016 Page 1. M-series MX Controller. Right-sized controllers. Easy to use

S-series DeviceNet Interface Card

S-series Sequence of Events Card

M-series MQ Controller

M-series Virtual I/O Module 2

M-series Foundation Fieldbus I/O

S-series H1 I/O Card with Integrated Power

S-series Horizontal Carriers

S-series Mass Connection Solutions

DeltaV M-series I/O Subsystem Horizontal Carriers

DeltaV Ethernet I/O Card

S-series Virtual I/O Module 2

DeltaV VerticalPlus I/O Subsystem Carriers

DeltaV Electronic Marshalling for Migrations

S-Series DeltaV Controller Interface for PROVOX I/O

DeltaV Bulk Power Supplies

DeltaV Bulk Power Supplies

M-series Profibus DP Series 2 Plus Interface Card

Ethernet I/O Card. Ethernet I/O Card. Introduction. DeltaV Product Data Sheet. Easy to use. Powerful integration solution. Modular, flexible packaging

DeltaV Wireless I/O Card

S-series Ethernet I/O Card

S-series DeviceNet Interface Card

S-series Virtual I/O Module 2

S-series Profibus DP Interface Card

M-series Virtual I/O Module 2

DeltaV PK Controller. Benefits. Introduction. Powerful Standalone. Easily Integrated. Faster module execution

M-series Serial Interface Series 2

M-series DeltaV Controller Interface for RS3 I/O

M-series Intrinsically Safe I/O

M-series Profibus DP Series 2 Plus Interface Card

S-series Serial Interface

S-series Electronic Marshalling for Migrations

M-series DeltaV Controller Interface for PROVOX I/O

DeltaV SIS Conditioning Components

S-series Sequence of Events Card

DeltaV Virtual IO Module Network Gateway

S-series Electronic Marshalling

M-series DC to DC Power Supply

S-series IS Electronic Marshalling

M-series I/O Subsystem Horizontal Carriers

DeltaV IS Electronic Marshalling

S-series Serial Interface

DeltaV Control Network Hardware

DeltaV M-series Traditional I/O

DeltaV Electronic Marshalling

DeltaV M-series Traditional I/O

DeltaV M-series Traditional I/O

DeltaV S-series Traditional I/O

Configuration Software Suite

DeltaV SIS TM. Logic Solver. DeltaV SIS Logic Solver. Introduction. DeltaV SIS Product Data Sheet. World s first smart SIS Logic Solver

Configuration Software Suite

S-series Electronic Marshalling

M-series Traditional I/O

M-series Serial Interface Series 2

Wireless Field Data Backhaul

CTO CSLS CHARM Cabinets

S-series IS Electronic Marshalling

S-series Electronic Marshalling

DeltaV Safety Instrumented System (SIS) with IS Electronic Marshalling

DeltaV SIS TMConditioning Components

Professional Station Software Suite

OPC Data Access Server Redundancy

Professional Station Software Suite

ProfessionalPLUS Station Software Suite

OPC Mirror Redundancy

Ovation Compact Controller

DeltaV Controller Firewall

Operator Station Software Suite

DeltaV Connect Solution for Moore Systems

DeltaV Discovery for Life Science Research Laboratory Applications

DeltaV Connect Solution for Siemens TELEPERM M Systems

Smart Commissioning. White Paper February 2018

AC 800M for Compact Product Suite Outline of all modules

OPC Mirror. Introduction. OPC Server. Bi-directional data flow. Easy configuration. Fast data transfer. OPC Data Access compliant.

Fast Control Response Requirement

Ovation Controller Model OCR1100

DeltaV Virtual Machine Controller Simulation

DeltaV SIS with Electronic Marshalling - Virtual Simulation

ISASecure SSA Certification for DeltaV and DeltaV SIS

DeltaV Remote Client. Introduction. Remote engineering and operator consoles. View Multiple DeltaV Systems from a single workstation

CTO CHARM Field Enclosure

Smart Commissioning. White Paper January 2019

DeltaV Connect Solution for Bailey Systems

DeltaV Simulate. Introduction. Product Data Sheet April DeltaV Distributed Control System

Use of Cisco Switches on the DeltaV Area Control Network (ACN)

DeltaV Controller Firewall

DeltaV Remote Client. Introduction. Remote engineering and operator consoles. View Multiple DeltaV Systems from a single workstation

AC 800M Controllers Outline of all modules

Operator Station Software Suite

Transcription:

DeltaV Distributed Control System Product Data Sheet January 2018 DeltaV SX Controller Scalable controllers Quick assembly Easy to use Field proven architecture Designed for Electronic Marshalling Advanced controls Introduction The DeltaV SX controller provide communication and control functions and integrate field devices and the other nodes on the control network. The SX, SQ and SD Plus controllers provide a choice to match the controller capacity to the requirements of the process. They also provide new ease of use features that eliminate mounting screws and accelerate cabinet assembly. Control strategies and system configurations created on earlier DeltaV systems can be used with this powerful controller. The SX Controller provides all the features and functions of the M-series controllers with the added support for CHARM based Electronic Marshalling. The control languages executed in the controllers are described in the Control Software product data sheet. Benefits Scalable controllers. The SX controller complements the SD Plus and SQ controller by providing additional CPU and Memory for those applications that need more control capacity: Late Changes. You can easily upgrade an SD Plus or SQ controller to an SX to handle project scope changes late in the project. Simply replace the SD Plus or SQ with the SX and all existing configuration, documentation and hardware design remain the same forgiving. The DeltaV SX Controller and the DeltaV I/O subsystem make rapid installation easy. Speed. The SX controller supports all the features you ve come to expect from the DeltaV system: self-addressing, automatic I/O detection. All these features are designed to make your projects execute faster just plug and play! Redundant Architecture. The SX controller supports 1:1 redundancy for increased availability. Redundant SD Plus or SQ controllers can be upgraded to SX controllers online robust! Quick Assembly. The S-series hardware has been redesigned for speed of project execution. Carriers snap to standard DIN rails and controllers and S-series IO snap into position without the use of retaining screws. Easy to Use. Controllers are also easy to configure. Simply connect the SX to the DeltaV network and auto-sense it from DeltaV Explorer. Add the controller and all its IO cards to the system database and all components are automatically addressed and communicating.

Control strategies are developed using IEC-61131 programming techniques: Function Blocks, Sequential Function Charts and Structured Text. Automatic diagnostics and event reporting with time stamps applied in the controller. Set control execution to match process dynamics and controller scheduling adjusts automatically. Reference any parameter by its module name, regardless of its location in the system. Synchronized system clock for consistent time based event driven actions across the system. Online expandable IO carriers allow new cards to be added online, with autosense capability, for modular system growth Hardware redundancy is automatically detected with zero configuration effort. Field Proven Architecture. The SX controller is an evolution of the DeltaV MX controller. The new design delivers installation and robustness enhancement while still using the same processor and OS that has proven itself in the field. All IO cards run the latest software enhancements of corresponding M-series IO cards and deliver the same field proven, reliable operation. Designed for Electronic Marshalling. The SX controller have highly distributable IO capabilities with CHARMs based Electronic Marshalling. Electronic Marshalling IO can be mounted anywhere, facilitating system design and expansion while reducing overall system footprint over traditional marshalled IO Subsystems. Advanced Controls. The SX controller supports all the advanced control features that are expected in a world class Distributed Control System: Batch Software Model Predictive Control Neural Networks Product Description The SX controller primary function is to execute control modules that are designed to meet the specific control requirements of the plant. These control modules use process signals from the controller s I/O subsystem and provide communication of process data to the rest of the DeltaV control system for operator interaction and data collection. Each controller node can be installed as a simplex or redundant node. The controllers are connected to the I/O carriers, which are mounted to the right of the controller carriers. Up to 8 carriers with 8 cards each can be connected to the local bus I/O, for a total of 64 traditional I/O cards. In addition to the 8 local I/O carriers, each controller can communicate with an additional 16 Remote I/O units hosting traditional card based I/O. In addition to traditional I/O cards, the local bus supports fieldbus technologies, including Foundation fieldbus, Profibus DP, DeviceNet and AS-I protocols. The I/O subsystem also supports Serial interface cards as well as the Ethernet I/O interface. These various I/O products provide a wide range of interfaces to meet the needs of your control application. The SX controller also supports CHARMs and WirelessHART I/O cards. The CHARM I/O Card (CIOC) connects via the redundant Ethernet ports of the controller to provide a highly distributed and flexible I/O solution called Electronic Marshalling. Up to 16 CIOC s can communicate to one controller, each providing up to 96 individually configurable signal types. The SX Controller. www.emerson.com/deltav 2

The capacity limits of the SX controller may vary depending on the particular application, amount of CHARM I/O Signals and as well control performance requirements. Enhanced memory handling and hardware alerts covering capacity and memory, via indexes, got added to the diagnostic information of the SX Controller. The WirelessHART I/O card (WIOC) provides redundant communication for up to 100 WirelessHART devices, providing high availability and reliability of wireless data. Up to 16 WirelessHART I/O cards can communicate to one controller, each providing up to 100 signals. Control modules are automatically scheduled by the controller, based on their assigned scan rates. This allows each control function to be optimized based on the process dynamics. Modules scan times can be set as fast as 100 ms, and as slow as 60 seconds. The number of control modules that can be assigned to a controller depends on the complexity and scan rate of each module, and the available CPU and memory. The SX controller should be used for medium to large applications with a maximum of 1500 individual I/O signals. The SX controller is designed for harsh environments and is rated for G3 corrosive environments, with an operating temperature range from -40 to 60 C. It is ideally suited for larger units with higher I/O counts. It can be field mounted close to the equipment, or centrally located in an equipment room. For more traditional installations with central marshalling cabinets, CHARM I/O cards can be mounted in standard I/O cabinets providing Electronic Marshalling. CHARM I/O cards can also be used for highly distributed I/O applications. DeltaV SX controller hardware dimensions. www.emerson.com/deltav 3

Hardware Specifications Specifications for the SX Controller DST Limit 1500 SCADA Tags 3200 Max Data Values Sent Max Data Values Received 4000/second 500/second Max Unsolicited Client Nodes 120 Module Execution Rates User Memory Fuse Protection (Internal) Power Dissipation 100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, 30s, 60s 96 MB 3.0 A, non-replaceable fuses 5.0 W typical, 7.0 W maximum Environmental Specifications Operating Temperature Storage Temperature Relative Humidity Airborne Contaminants Shock (Normal Operating Conditions) Vibration (Operative Limit) -40 to 60 C (-40 to 140 F) -40 to 85 C (-40 to 185 F) 5 to 95%, non-condensing ISA-S71.04-1985 Airborne Contaminants Class G3 Conformal coating 10 g ½-sine wave for 11 ms 1 mm peak-to-peak from 5 Hz to 13.2 Hz, 0.7 g from 13.2 Hz to 150 Hz LED Indicators Green Power Red Error Green Active Green Standby Yellow Flashing Pri. CN Yellow, Flashing Sec. CN Indicates DC power is applied. Indicates an error condition. Indicates that the controller is operating as the primary controller. Indicates that the controller is operating as a backup controller (reserved for future use). Indicates valid primary control network communication. Indicates valid secondary control network communication. External Connections Primary Control Network Redundant Control Network 8-pin RJ-45 connector 8-pin RJ-45 connector www.emerson.com/deltav 4

Certifications The following certifications are available on the SX controller. CE: EMC- EN 61326-1 FM: FM 3600 FM 3611 CSA: CSA C22.2 No. 213-M1987 CSA C22.2 No. 1010-1 ATEX: ATEX 94/9/EC EN 60079-0 EN 60079-15 IEC Ex: IEC60079-0 IEC60079-15 Marine Certifications: IACS E10 Hazardous Area/Locations The DeltaV SX Controller can be installed and used based on the following Standards: FM (USA): Installation: Class I, Division 2, Groups A, B, C, D, T4 cfm (Canada): Installation: Class I, Division 2, Groups A, B, C, D, T4 ATEX: [Ex] II 3 G Ex na IIC Gc IEC Ex: Installation: Ex na IIC T4 Gc Regarding the installation instructions please refer to the following documents: Class 1 Division 2 Installation Instructions DeltaV S-Series (12P5402) Zone 2 Installation Instructions DeltaV S-series (12P5404) - ABS Certificate of Design Assessment - DNV GL Type Approval Certificate Wurldtech: Achilles Communications Certification Level 1 (v12.3) Achilles Communications Certification Level 2 (v13.3.1 & v14.3) www.emerson.com/deltav 5

S-series SX Controller January 2018 Ordering Information Description Model Number SX Controller SE3007 Prerequisites For each controller you will need a power controller carrier. Please refer to the S-series Horizontal Carriers product data sheet for details. Each controller requires a dedicated system power supply. Please refer to the S-series Power Supplies product data sheet for details. Emerson North America, Latin America: +1 800 833 8314 or +1 512 832 3774 Asia Pacific: +65 6777 8211 Europe, Middle East: +41 41 768 6111 www.emerson.com/deltav 2018, Emerson. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. The DeltaV logo is a mark of one of the Emerson family of companies. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.