BACnet MS/TP Gateways for Mega Controls Modbus RTU Networking Devices

Similar documents
BACnet-over-Ethernet (BACnet TCP/IP) Gateways for Modbus RTU Devices

RS-485 Modbus RTU Networking FCU Thermostats with 0(2)-10 VDC Fan Output

RS-485 Modbus RTU Networking Room Thermostats with LCD for Fan Coil Units

RS-485 FClink Networking Room Thermostats with LCD for Fan Coil Units

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

NT10 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

BACnet Product Overview

TC-9102 Terminal Controller

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

Field selectable application type and room module series, via dip-switches on controller

BACnet Flow Controller for Fan Filter Units

FCU-MULTI Modbus Fan Coil Unit Controller

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

EasyIO FC20 User Reference v1.3. EasyIO FC 20 DDC User Reference V1.3

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

BACnet. b3867 Terminal Controllers

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

BACnet Controller for General-purpose Building Applications

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

FCU-4 FAN COIL CONTROLLER

Siemens BACnet Programmable TEC Unit Conditioner Controller

System-10 BTU Meter BACnet Network Interface Installation Guide

Siemens BACnet Programmable TEC Unit Vent Controller

Siemens BACnet Programmable TEC Constant Volume

Andover ContinuumTM. b3850 Series Terminal Controllers

Communicative controller for VAV systems

Andover ContinuumTM Infinet II

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

FX Input/Output (I/O) Modules XM07 and XM14

MANUAL INSTALLATION. Multi-Variable Monitor. MVM Series. Issue Date: 02/07/ Price Industries Limited. All rights reserved.

Siemens BACnet Programmable TEC Unit Vent Controller for Smoke Control

clarity 3 Programmable Controller

BACnet. b3810 Series Local Controllers

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

S66 Series Electronic Fan Speed Control

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller

Siemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller

Submittal Data Sheet intelligent Touch Manager DCM601A71

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

CONTROLS.COM. Bacnet and Modbus Modules. T3-22i. T3000 Building Automation System Overview. T3-8o. Ethernet MAIN NET1 RS485 SUBNET2 RS485.

Extended Digital Controller

FCU-4 FAN COIL CONTROLLER

CBX System. CBX System TECHNICAL DATASHEET & INSTALLATION GUIDE DESCRIPTION APPLICATION

Andover ContinuumTM Infinet II

BACnet Terminal Box (VAV) Controller

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

The Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box

Modbus communication module for TCX2: AEX-MOD

IntesisBox PA-AC-MBS-1

IntesisBox PA-AW-MBS-1 v.2.0

Networkable Dual Duct VAV Controller Specification and Installation Instructions

Submittal Data Sheet WAGO Node for itm

BAC-9000 Series VAV Controller Installation Guide

FX06 Field Controller

isma-b-fcu FCU Hardware User Manual Global Control 5 Sp. z o.o. Warsaw, Poland

BAPI-Stat 4MB Modbus Temp or Temp/Humidity Sensor

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Multi-Point Gas Detection and Control System

IntesisBox ModBus RTU Fujitsu Air Conditioning

MOD-RI Room Interface Modules with Modbus

iologik E1200H Series

Multi-Point Gas Detection and Control System

NovoCon S Digital/Hybrid - High Accuracy Actuator

IntesisBox. v.2.5. User Manual Issue Date: 12/2017 r1.9 EN. Modbus RTU (EIA-485) Interface for Fujitsu air conditioners.

FXVMA Variable Air Volume (VAV) Box Controller

Multi-Point Gas Detection and Control System

Small distributed I/O module

NIEx9. Metasys. BAS network automation Supervisory controllers. Network Integration Engine

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

Measure & Control Temperature & CO2 levels with analog & digital I/O

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

RTD-NET Installation Instructions

Remote I/O Communication Module Specification and Installation Instructions

Smart Equipment Controls (SEC)

HARDWARE GUIDE. Water Loop Controller C1000 Series. Specifications and Operational Guide

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

Temperature controller Ducted systems

P216. Condenser fan speed controller. Product bulletin. Features

M1000 INTELLIGENT ZONE CONTROL SYSTEM

Andover ContinuumTM Infinet II

HRM-0800 Instruction Manual

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

D-100 FLOW DISPLAY MODBUS Network Interface Installation Guide

Lab and Central Plant Controller

Accutrol, LLC Product Sheet AVC5000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

RTD-W Installation Instructions

USER S MANUAL. DAS-G01 The Power of Tomorrow

IntesisBox KNX - AIRZONE

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

MS/TP Communications Bus for the BCProTM System Technical Bulletin

Modular Room Control (MRC) Series Expansion Board

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

P216 Series Condenser Fan Speed Controller

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.

Transcription:

BMG Series Issue Date March 1, 2018 BACnet MS/TP Gateways for Mega Controls Modbus RTU Networking Devices General The BMG Series is a BACnet network gateway which routes communication traffic between BACnet MS/TP network and Modbus RTU network. While the gateway (master) communicates on a RS-485 network at its NET1 communication port using the BACnet MS/TP protocol, it can support up to 32 Mega Controls NT10, NT50, NTAF, NSM, NC24A or NC24T RS-485 networking devices (slaves) on a RS-485 network at its NET2 communication port using Modbus RTU protocol. The gateway spontaneously detects the presence of slaves that go online in its NET 1 network. However, these devices must not be mixed and must be of the same series or type in NET2 network trunk. NT10 Series and NT50 Series are treated as the same type of devices and can be mixed in the same network trunk. The gateway has 2 addresses. NET 2 address is always 0 which is the address of the Modbus RTU network. NET 1 address is the MAC address of the BACnet MS/TP network which is set up for a maximum of 32 devices. The NET 1 address is set via DIP switches in the device. If more than 32 masters are needed in the system, an additional network supervising device is required for the second BACnet MS/TP network. Mounting It is strongly recommended to mount the gateway inside a metal cabinet for EMI shielding protection, with 2 or 4 screws or rack-mounted in a DIN rail. Ordering To order, specify the complete gateway model number with specific communication protocol to suit applicable networking devices. Specifications Gateway model numbers BMG-1 Universal BACnet MS/TP gateway for Mega Controls NT10/NT50 Series, NTAF Series, NSM Series, NC24A or NC24T Power requirements Voltage 22-28 V 50/60 Hz or 16-30 VDC Current Maximum 200 ma Technology CPU 32-bit ARM at 48M clock ROM 256 kb Flash RAM 64 kb SRAM EEPROM 2 kb NET 1 communication port Physical RS-485 with opto-coupler Isolation Baud rate Protocol Indicators Device MAC address Maximum number Service supported Objects supported Field selectable 9600, 19200, 38400 or 76,800 bps set via DIP switches (factory set 38,400 bps) BACnet MS/TP Red LED for data receiving and green LED for data transmitting Set via DIP switches 32 BMGs in one BACnet MS/TP network WhoIs, ReadProperty, ReadPropertyMultiple, WriteProperty Device, Analog Input, Analog, Analog Value, Binary Input, Binary, Input, Static Object names NET 2 communication port Physical RS-485 with opto-coupler Isolation Baud rate Fixed at 19,200 bps Protocol Modbus RTU Indicators Red LED for data receiving and green LED for data transmitting Device address Always 0 Maximum number 32 slaves in one Modbus RTU network Ambient/storage temperature limits 0 to 55 o C / -30 to 50 o C, 10 to 90% RH Non-condensing Wiring class Class II for 24 VAC Power Supply Connectors Removable screw-type terminal connectors Power wires Wire size 1 mm 2 or 18 AWG solid copper recommended Communication wires Balanced 100 to 120 Ω nominal Impedance twisted shielded pair (TSP) cable Shipping weight 0.25 kg (1 lb) Dimensions 90 x 116 x 40 mm (W x L x D) The performance specifications above are nominal and subject to tolerances and application variables of generally acceptable industry standards. The manufacturer shall not be liable for damages resulting from misapplication or misuse of its products. Copyright Mega Controls Limited www.megacontrols.com 1

Language, Gateway Instance ID and Communication Protocol Setup Procedure System Setting Objects There are 2 objects for system setup defined as: Object Name Object Value Unit Object Type Read/Write *** SYS SELECT yyyyyy.av1 (*2) *1 Analog Variable R/W *** SYS VALUE yyyyyy.av2 (*2) *1 Analog Variable R Note: System setting can be changed by writing value to *** SYS SELECT. Write property Function Description value to ***SYS SELECT 2012 Change all descriptions to CHINESE. New setting will take effect after entering a restart command 3003 followed by reloading descriptors at the BMG Manager. 2014 Change all descriptions to ENGLISH. New setting will take effect after entering a restart command 3003 followed by reloading descriptors at the BMG Manager. 3003 Restart 2004 To set device instance ID. This is a two-step operation: after writing 2004 to ***SYS SELECT, wait until *** SYS VALUE changes to 1, then write an integer n (where 0 n 12799) to ***SYS SELECT. Assuming the DIP switches MAC address is set as m, the device instance ID is n*100 + m. New setting will take effect after entering a restart command 3003 followed by a discovering new devices at the BACnet workstation. Notes: After all new entries have taken into effect, the new data will be saved to the EEPROM. Power restart will resume all data saved before power failure. Derived Network Addressing (DNA) The DNA DIP switch is set by factory default to ON position. This allows the gateway to automatically configure a BACnet instance ID number. This setting should not be changed unless an authorized agent is assigning a BACnet instance ID number through the system setup procedure. The BACnet instance ID number should not be confused with the gateway MAC address DIP switch setting, and each gateway must still have a unique DIP switch MAC address even when using software to define the gateway s instance ID number. Example: If the MAC address of the upstream network router or controller is 8 and the gateway MAC address is set as 13, the gateway s DNA BACnet Instance ID is 80013 (8 x 10000 + 13). Notes: *1 When DNA function is turned on (DIP switch set as 1), 2004 function is disabled. When DNA function is turned off (DIP switch set as 0), 2004 function is enabled. Disconnect power supply before changing DNA switch position. *2 yyyyyyy is the the BACnet instance ID number which can be either the DNA or a number assigned manually through the system setup procedure. Gateway MAC Addressing The DIP switch is a binary switch. Each individual DIP switch represents a unique value, which forms the gateway MAC address when added together. To set the address, simply move the switches that add up to the gateway s desired address to the ON position. Example: If the gateway is to be address 7 on the network, set the switches numbered 1, 2 and 4 (equals 7) to the ON position. Note: Each gateway on the same MS/TP network segment must have a unique DIP switch address. Gateway Baud Rate Setting Make sure that the baud rate of the gateway is set to match the network baud rate. Example: If the network baud rate is 38,400 bps, set the DIP switches X2 and X4 to OFF and ON respectively. Network, Cabling and Step-down Transformer Requirements To ensure network stability and reliable communications, particularly at high speeds on a BACnet MS/TP network for a number of devices, it is imperative that the following network and cabling requirements are adhered to: 2 BMG Series BACnet MS/TP Gateways Product Bulletin

Item Description Cabling It is recommended to use networking cabling that matches the following specifications: Balanced 100 to 120 ohms nominal impedance, 22 or 24 AWG Twisted Shielded Pair (TSP) Cable Nominal capacitance of 52 pf/m or lower Nominal velocity of propagation of 66% or higher Terminating the shield to ground at one end only for each isolated segment will prevent ground loops in the shield and drain RF energy to ground. Grounding at the BACnet router or controller is preferred. Topology Ensure both the BACnet MS/TP network cable and Modbus RTU network cable are installed as a daisy chain from one device to the next. Maximum Nodes The maximum number of devices is 32 per BACnet MS/TP or Modbus RTU network. Terminator A terminator of 120-ohm impedance must be installed at each end of each BACnet MS/TP or Modbus RTU network. Ensure that this requirement is not overlooked in laying out the network architecture and when ordering product. Cable Shielding Use a shielded, twisted pair cable for communications. Never directly ground wire in more than one point on the shield. Doing so can induce large currents and result in communication problem. Repeater A repeater is not necessary unless more than 32 nodes is extended beyond 1,000 m. Step-down Transformer A separate isolated double-wound transformer is recommended for supplying 24 VAC power to each BMG. If and when the same transformer is shared with other devices, observe the polarities of the power supply of all devices including the BMG. Network Configuration To BACnet MS/TP Network Supervisor BMG (Master) BMG (Master) Slaves Termination Diagram Dimensions in mm BMG Series BACnet MS/TP Gateways Product Bulletin 3

Dynamic Created Objects The gateway spontaneously detects the presence of a NT10,NT50, NTAF, NSM, NC24A or NC24T slave that goes online in its NET 2 network and automatically creates a number of pre-defined objects associated with this NT10,NT50, NTAF, NSM, NC24A or NC24T slave s MAC address. When this NT10,NT50, NTAF, NSM, NC24A or NC24T slave goes offline, these objects will be automatically deleted. For NT10 and NT50 Modbus RTU Networking Room Thermostats If the NT10 s or NT50 s MAC address is xx, its associated objects are: Read/Write #xxnt - Temperature Setpoint yyyyyy.aoxx1 (5-35) / (41-95) Analog #xxnt - Operating Mode yyyyyy.boxx1 Stop/Run Binary #xxnt - Control Mode yyyyyy.moxx1 Heat/Cool/ Fan Only/Auto #xxnt - Fan Speed Command yyyyyy.moxx2 High/Medium/ Low/Auto #xxnt - Ambient Temperature yyyyyy.aixx1 (5-35) / (41-95) Analog Input R #xxnt - Valve 1 Status yyyyyy.aixx2 (0-100) % Analog Input R #xxnt - Valve 2 Status yyyyyy.aixx3 (0-100) % Analog Input R #xxnt - Temperature Eng. Unit yyyyyy.bixx1 ºC/ºF Binary Input R #xxnt - Unoccupied Mode yyyyyyy.bixx2 Off/On Binary Input R #xxnt - Binary Input yyyyyy.bixx3 Open/Closed Binary Input R #xxnt - Window Modeª yyyyyy.mixx1 Off/On/ Input R #xxnt - Fan Totalizator yyyyyy.avxx1 0-999999 hr Analog variable R/W #xxnt - Cooling Totalizator yyyyyy.avxx2 0-999999 hr Analog variable R/W #xxnt - Heating Totalizator yyyyyy.avxx3 0-999999 hr Analog variable R/W *** SYSTEM SELECT yyyyyy.av1 *1 Analog variable R/W *** SYSTEM SELECT yyyyyy.av2 *1 Analog variable R BMG_MANAGER_yyyyyy yyyyyy.devyyyyyy Operational Device R ª The value of this object is displayed as Off/On for NT10 Series or for NT50 Series thermostats. For NTAF Modbus RTU Networking Room Thermostats If the NT10 s or NT50 s MAC address is xx, its associated objects are: Read/Write #xxnt - Temperature Setpoint yyyyyy.aoxx1 (5-35) / (41-95) Analog #xxnt - Operating Mode yyyyyy.boxx1 Stop/Run Binary #xxnt - Control Mode yyyyyy.moxx1 Heat/Cool/ Fan Only/Auto #xxnt - Fan Speed Command yyyyyy.moxx2 1/2/3/4/5/6/7/Auto #xxnt - Ambient Temperature yyyyyy.aixx1 (5-35) / (41-95) Analog Input R #xxnt - Valve 1 Status yyyyyy.aixx2 (0-100) % Analog Input R #xxnt - Valve 2 Status yyyyyy.aixx3 (0-100) % Analog Input R #xxnt - Temperature Eng. Unit yyyyyy.bixx1 ºC/ºF Binary Input R #xxnt - Unoccupied Mode yyyyyyy.bixx2 Off/On Binary Input R #xxnt - Binary Input yyyyyy.bixx3 Open/Closed Binary Input R #xxnt - Window Mode yyyyyy.mixx1 Off/On/ Input R #xxnt - Fan Totalizator yyyyyy.avxx1 0-999999 hr Analog variable R/W #xxnt - Cooling Totalizator yyyyyy.avxx2 0-999999 hr Analog variable R/W #xxnt - Heating Totalizator yyyyyy.avxx3 0-999999 hr Analog variable R/W *** SYSTEM SELECT yyyyyy.av1 *1 Analog variable R/W *** SYSTEM SELECT yyyyyy.av2 *1 Analog variable R BMG_MANAGER_yyyyyy yyyyyy.devyyyyyy Operational Device R 4 BMG Series BACnet MS/TP Gateways Product Bulletin

For NSM Modbus RTU Networking Setpoint Modules If the NSM s MAC address is xx, its associated objects are: For NC24A Modbus RTU Networking Controllers If the NC24A s MAC address is xx, its associated objects are: Read/ Write #xxnc - Controller Setpoint yyyyyy.aoxx1-99 to 999 Analog #xxnc - X1 Analog Input Value yyyyyy.aixx1-99 to 999 Analog Input R #xxnc - X2 Analog Input Value yyyyyy.aixx2-99 to 999 Analog Input R #xxnc - ECO Mode Status yyyyyy.bixx1 Off/On Binary Input R #xxnc - Day/Night Mode Status yyyyyy.bixx2 Day/Night Binary Input R #xxnc - Engineering Unit yyyyyy.mixx1 ºC/ºF/%/ Input R #xxnc - Application Number yyyyyy.avxx1 1 to 9 Analog Variable R #xxnc - Setpoint Differential yyyyyy.avxx2 (1 to 20 )/(1 to 99) Analog Variable R #xxnc - Control Bandwidth yyyyyy.avxx3-99 to 99 Analog Variable R #xxnc - Y1 Status yyyyyy.avxx4 0 to 100 % Analog Variable R #xxnc - Y2 Status yyyyyy.avxx5 0 to 100 % Analog Variable R #xxnc - Q1 Status yyyyyy.avxx6 0 to 100 % Analog Variable R #xxnc - Proportional Band yyyyyy.avxx7 (1 to 20)/(1 to 99) K Analog Variable R #xxnc - Integral Time yyyyyy.avxx8 0 to 30 min Analog Variable R *** SYSTEM SELECT yyyyyy.av1 *1 Analog Variable R/W *** SYSTEM SELECT yyyyyy.av2 *1 Analog Variable R BMG_MANAGER_yyyyyy yyyyyy.devyyyyyy Operational Device R For NC24T Modbus RTU Networking Controllers If the NC24T s MAC address is xx, its associated objects are: Read/ Write #xxnc - Controller Setpoint yyyyyy.aoxx1-99 to 999 Analog #xxnc - X1 Analog Input Value yyyyyy.aixx1-99 to 999 Analog Input R #xxnc - X2 Analog Input Value yyyyyy.aixx2-99 to 999 Analog Input R #xxnc - ECO Mode Status yyyyyy.bixx1 Off/On Binary Input R #xxnc - Day/Night Mode Status yyyyyy.bixx2 Day/Night Binary Input R #xxnc - Engineering Unit yyyyyy.mixx1 ºC/ºF/%/ Input R #xxnc - Application Number yyyyyy.avxx1 1 to 12 Analog Variable R #xxnc - Setpoint Differential yyyyyy.avxx2 (1 to 20 )/(1 to 99) Analog Variable R #xxnc - Control Bandwidth yyyyyy.avxx3-99 to 99 Analog Variable R #xxnc - Main Status yyyyyy.avxx4 0 to 100 % Analog Variable R #xxnc - Secondary Status yyyyyy.avxx5 0 to 100 % Analog Variable R #xxnc - Valve Stroke Time yyyyyy.avxx6 10 to 240 sec Analog Variable R #xxnc - Proportional Band yyyyyy.avxx7 (1 to 20)/(1 to 99) K Analog Variable R #xxnc - Integral Time yyyyyy.avxx8 0 to 30 min Analog Variable R *** SYSTEM SELECT yyyyyy.av1 *1 Analog Variable R/W *** SYSTEM SELECT yyyyyy.av2 *1 Analog Variable R BMG_MANAGER_yyyyyy yyyyyy.devyyyyyy Operational Device R BMG, 18-03(Mega) BMG Series BACnet MS/TP Gateways Product Bulletin 5 Read/ Write #xxns - Module Setpoint yyyyyy.aoxx1-99 to 999 Analog #xxns.- Operating Mode yyyyyy.boxx1 Stop/Run Binary #xxns.- Analog Input Type yyyyyy.aixx1 0 or 1^ Analog Input R #xxns - Analog Input Value yyyyyy.aixx2-99 to 999 Analog Input R #xxns - Set Display Lower yyyyyy.avxx1-99 to 999 Analog Variable R/W #xxns - Set Display Upper yyyyyy.avxx2-99 to 999 Analog Variable R/W #xxns - Remote Set Lower yyyyyy.avxx3-99 to 999 Analog Variable R/W #xxns - Remote Set Upper yyyyyy.avxx4-99 to 999 % Analog Variable R/W *** SYSTEM SELECT yyyyyy.av1 *1 Analog Variable R/W *** SYSTEM SELECT yyyyyy.av2 *1 Analog Variable R BMGE_MANAGER_10123 yyyyyy.devyyyyyy Operational Device R Notes: ^ 0 denotes 0-10 VDC input and 1 denotes temperature sensor input. Mega Controls Limited Room 1521A, Star House 3 Salisbury Road, Tsimshatsui, Kowloon, Hong Kong Phone: +852 6281 1320 Fax: +852 3741 7084 E-mail: sales@megacontrols.com Website: www.megacontrols.com