ETT 312 Build-In Touch Terminal

Similar documents
ETT 352 Touch Operating Panel

HZS 352 Touch Room Unit

HZS 351 Room Touch Control Panel

KL 181 S-DIAS +24 V Potential Distributor Module

DM 161 S-DIAS Digital Mixed Module

ICA 012 S-DIAS Interface Module CAN

ISE 021 S-DIAS Interface Module RS232 / RS485

TO 161 S-DIAS Digital Output Module

AO 081 S-DIAS Analog Output Module

RO 051 S-DIAS Relay Output Module

SI 021 S-DIAS SSI Interface Module

SE 051 S-DIAS Splitter Ethernet

VI 021 S-DIAS VARAN Control Module

TSY 041 Training System Extension Motion

HZS Internal Controller Expansion

PS 101 S-DIAS Power Supply Module

TAE 1921 Touch Display Unit

PC 521 Data Recording PC

DC S-DIAS Axis Module

AI 046 S-DIAS Analog Input Module

MDM 011-Z1 Regen Resistor

Expansion Module HZS 541-1S

ETT 412 Touch Operating Panel Technical Manual

TAE 1921 Touch Display Unit

VARAN Splitter Module VSV 041

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

HZS Solar Module

FL MC 2000E (SM40) LC

2 Device description. 2 Device description 2.1 Function. 2.1 Function. 2.2 Intended use. 2.3 Device versions

Connection Cables for Operating Devices

C-DIAS Digital Input Module CDI 161 with 16 inputs

ISOMETER isoev425 with coupling device AGH420

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration

VARAN Splitter PROFINET VSP 044

LED W RGBA User Manual

8B0C0320HW General information. 2 Order data. 3 Technical data 8B0C0320HW

User Manual. Rack Mount Display Monitor - 4K RMP-161-4K17. 7U 17.3 inch Rack Mount Display Monitor

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

DIAS Interface Module VARAN DIV 511

VARAN Splitter Module VSV 043

Mounting and Operating Instructions of RP406K and RP406K-IC for mobile video surveillance

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

ISOMETER isoev425/isoev425hc with coupling device AGH420

PanelView Plus/VersaView CE Terminals and Display Modules

PX 227. DMX Demux 8. Manual

TM3AI4 module TM3-4 analog inputs

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

AO561 Analog Output Module

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

User Manual. Rack Mount Display Monitor RMP-161-F17A. 6U 17.3 inch Rack Mount Display Monitor. Options : - AV, S-video input - Touchscreen

AI531 Analog Input Module

IGLOO IGLOO EASY INSTRUCTION MANUAL

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

VARAN Bus Coupler Module VBC 021 For connecting two VARAN bus systems

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

IGLOO IGLOO EASY INSTRUCTION MANUAL

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

QUINT-PS/ 1AC/24DC/ 5

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Keyboard Unit Sigmatek

27 Industrial Chassis Monitor

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

MINI-PS AC/10-15DC/8

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

MobileView Junction Box

AI561 Analog Input Module

TRIO-DIODE/12-24DC/2X10/1X20

PHOENIX CONTACT - 07/2006

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Communication & Networking

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PC 400 Control Cabinet PC

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

TM3TI4 module TM3-4 inputs temperature

C-DIAS EtherNet/IP Slave CIP 022

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

TU531, TU532 Terminal Unit

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

HMISCU6A5 3 5 color touch controller panel - Dig 16 inputs/10 outputs

AO523 Analog Input Module

VARAN Splitter PROFINET VSP 042

Auxiliary Board MP-Bus HZS 562

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions

STEP-PS/1AC/24DC/1.75

15 TFT-LCD Monitor Operation Manual

HMISCU8A5 5 7 color touch controller panel - Dig 16 inputs/10 outputs

TF501, TF521 Terminal Bases

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

TM3TI8T module TM3-8 inputs temperature

C-DIAS Analogue Output Module CAO 081 for eight 10V DC outputs

XBTGC2330T 5 7 LCD TFT color controller panel - 16 inputs/16 outputs source

HZS 772 Touch Operating Panel

Transcription:

ETT 312 Build-In Touch Terminal Date of creation: 01.02.2016 Version date: 23.01.2017 Article number: 01-230-312-E

Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18 Email: office@sigmatek.at WWW.SIGMATEK-AUTOMATION.COM Copyright 2016 SIGMATEK GmbH & Co KG Translation from German All rights reserved. No part of this work may be reproduced, edited using an electronic system, duplicated or distributed in any form (print, photocopy, microfilm or in any other process) without the express permission. We reserve the right to make changes in the content without notice. The SIGMATEK GmbH & Co KG is not responsible for technical or printing errors in the handbook and assumes no responsibility for damages that occur through use of this handbook.

BUILD-IN TOUCH TERMINAL ETT 312 Build-In Touch Terminal ETT 312 3.5 color display with resistive touch CAN bus and +24 V supply Metal front with 1 color front foil 23.01.2017 Page 1

ETT 312 BUILD-IN TOUCH TERMINAL Contents 1 Technical Data... 4 1.1 Performance Data... 4 1.2 Electrical Requirements... 4 1.3 Controller... 4 1.4 Display... 5 1.5 Terminal... 5 1.6 Environmental Conditions... 6 1.7 Miscellaneous... 6 2 Mechanical Dimensions... 7 3 Connector Layout... 8 3.1 Ground connection... 9 3.2 Applicable Connectors... 9 4 Mounting Instructions... 10 4.1 Vertical Mounting Position... 10 5 CAN Bus Protocol... 11 6 CAN Bus Setup... 11 6.1 CAN Bus Station Number... 11 6.2 CAN Bus Data Transfer Rate... 11 7 CAN Bus Termination... 12 Page 2 23.01.2017

BUILD-IN TOUCH TERMINAL ETT 312 8 Cleaning the Touch Screen... 13 23.01.2017 Page 3

ETT 312 BUILD-IN TOUCH TERMINAL 1 Technical Data 1.1 Performance Data Interfaces 1x CAN bus Data rate max. 1 Mbits/s 1.2 Electrical Requirements Supply voltage typically +24 V DC (+18-30 V DC) Current consumption of power supply at +24 V typically 60 ma maximum 100 ma Inrush current typically 0.9 A for 10 ms maximum 1.2 A for 20 ms UL standard for UL (1) : must be supplied with SELV / PELV and Limited Energy Digital output also is SELV / Limited Energy. (1) In US according to Class 2 UL 1310 or UL 61010-1, 3 rd edition, chapter 9.4 or LPS (limited power supply) UL 60950-1 or Limited Energy UL 1585 1.3 Controller Controller Internal data memory for visualization (SDRAM) Internal data memory for visualization (flash) Cortex-M3 8-Mbyte 8-Mbyte Page 4 23.01.2017

BUILD-IN TOUCH TERMINAL ETT 312 1.4 Display Type 3.5 LC graphic display Resolution 320(RGB) x 240 Pixel size Number of pixels Active surface Color depth Backlighting 0.219 x 0.219 mm 320*3 (RGB) x 240 pixels 70.08 x 52.56 mm 24-bit 6x LED, white, regulatable Contrast 400:1 TOUCH Brightness resistive typically 350 cd/m² Visible field left, right, below 70, above 60 1.5 Terminal Operating unit dimensions 103.6 x 99.6 x 38.1 mm (W x H x D) with opposing connector 111.8 x 107.8 x 38.1 mm (W x H x D) with opposing connector and fastening clips Control cabinet cutout minimum 92.2 x 88.2 mm (W x H) maximum 93.5 x 89.5 mm (W x H) Material Weight front plate: 3 mm anodized aluminum ca. 250 g 23.01.2017 Page 5

ETT 312 BUILD-IN TOUCH TERMINAL 1.6 Environmental Conditions Storage temperature -10... +70 C Environmental temperature 0... +55 C Humidity 10-90 %, non-condensing Operating conditions Pollution degree 2 Indoor use Altitude up to 2000 m EMC resistance EMC noise generation according to EN 61000-6-2 (industrial area) according to EN 61000-6-4 (industrial area) Vibration resistance EN60068-2-6 3.5 mm from 5-8.4 Hz 1 g from 8.4-150 Hz Shock resistance EN 60068-2-27 15 g Protection type EN 60529 front: IP65 (no UL-rating) cover: IP20 (no UL-rating) 1.7 Miscellaneous Article number 01-230-312 Hardware version 1.x Standard UL 61010-2-201 Approbations UL, cul, CE Page 6 23.01.2017

BUILD-IN TOUCH TERMINAL ETT 312 2 Mechanical Dimensions 23.01.2017 Page 7

ETT 312 BUILD-IN TOUCH TERMINAL 3 Connector Layout X1: CAN Bus (5-pin Phoenix RM 3.5) Pin Signal Function 1 CAN A CAN LOW IN 2 CAN B CAN HIGH IN 3 CAN A CAN LOW OUT 4 CAN B CAN HIGH OUT 5 GND GND Page 8 23.01.2017

BUILD-IN TOUCH TERMINAL ETT 312 X2: Supply (4-pin Phoenix RM 3.5) Pin Signal Function 1 +24 V Supply voltage 2 +24 V Supply voltage 3 GND GND 4 GND GND 3.1 Ground Connection M3 Threaded Bolt Grounding is realized with a M3 threaded bolt including a latch plate. A low-ohm connection to ground has to be established. 3.2 Applicable Connectors Connectors: X1-X2: Connectors with spring terminals (included in delivery) Connections: Stripping length: Mating direction: Conductor cross section rigid: 0.2-1.5 mm 2 Conductor cross section flexible: 0.2-1.5 mm 2 Conductor cross section AWG/kcmil: 24-16 Conductor cross section flexible with 0.25-1.5 mm 2 Ferrule without with plastic sleeve: Conductor cross section flexible with Ferrule with plastic sleeve: 10 mm parallel to the conductor axis or circuit board 0.25-0.75 mm 2 (reason for reduction d2 of the ferrule) 23.01.2017 Page 9

ETT 312 BUILD-IN TOUCH TERMINAL 4 Mounting Instructions The build-in terminal is provided for mounting in a control cabinet wall. For mounting in the control cabinet wall 4 angle clamps with threaded pins are provided. So the front is pressed against the outer control cabinet wall. The angles are fixed with a flat head screwdriver with 0.2 Nm and thus guarantee the necessary IP protection level of the front. The modules must be mounted vertically with sufficient clearance between the ventilation slots of the build-in terminals and nearby components and/or the control cabinet back wall. This is necessary for optimal cooling and air circulation, so that proper function up to the maximum operating temperature is ensured. 4.1 Vertical Mounting Position Page 10 23.01.2017

BUILD-IN TOUCH TERMINAL ETT 312 5 CAN Bus Protocol Display communication CAN object number: CAN bus object for receiving data: 0x200 + CAN bus station (0x00 0x1F) CAN bus object for sending data: 0x040 + CAN bus station (0x00 0x1F) 6 CAN Bus Setup This section explains how to correctly configure the CAN bus. The following parameters must first be set: Station number and data transfer rate. During start up the parameters can be set on the setup screen of the terminal. 6.1 CAN Bus Station Number Each CAN bus station is assigned its own station number. With this station number, data can be exchanged with other stations connected to the bus. Up to 31 stations can be installed in a CAN bus system. In a CAN bus system however, each station number can only be assigned once! 6.2 CAN Bus Data Transfer Rate Various data transfer rates (baud rates) can be set on the CAN bus. The longer the bus line is, the lower the data transfer rate that must be selected. Value Baud Rate Maximum Length 0 615 kbits/s 60 m 1 500 kbits/s 80 m 2 250 kbits/s 160 m 3 125 kbits/s 320 m 4 100 kbits/s 400 m 5 50 kbits/s 800 m 6 20 kbits/s 1200 m 7 1 Mbits/s 30 m These values apply to the following cable: 120, Twisted Pair. 23.01.2017 Page 11

ETT 312 BUILD-IN TOUCH TERMINAL 7 CAN Bus Termination In a CAN bus system, both end modules must be terminated. This is necessary to avoid transmission errors caused by reflections in the line. For the CAN bus a shielded connector cable must be used. The shield of the cable must have a low-ohm connection to the ground. The line termination is provided by a 120 resistor on the opposing connector between PIN 3 and PIN 4. Page 12 23.01.2017

8 Cleaning the Touch Screen BUILD-IN TOUCH TERMINAL ETT 312 CAUTION! Before cleaning the touch screen, the terminal must first be turned off to avoid unintentionally triggering functions or commands! The terminal's touch screen can only be cleaned with a soft, damp cloth. A screen cleaning solution such as an anti-static foam, water with a mild detergent or alcohol should be used to dampen the cloth. The cleaning solution should be sprayed onto the cloth and not directly on the terminal. The cleaning solution should not be allowed to reach the terminal electronics, for example, through the ventilation slots. No erosive cleaning solutions, chemicals, abrasive cleansers or hard objects that can scratch or damage the touch screen may be used. If the terminal comes in contact with toxic or erosive chemicals, carefully clean the terminal immediately to prevent corrosion! To ensure the optimal function of the terminal, the touch screen should be cleaned at regular intervals! To extend the lifespan of the touch screen as much as possible, using the fingers to operate the terminal is recommended. 23.01.2017 Page 13

ETT 312 BUILD-IN TOUCH TERMINAL Documentation Changes Change date Affected page(s) Chapter Note 01.03.2016 9 3.1 Ground Connection Latch plate added 25.03.2016 5 1.4 Display Table updated 23.01.2017 4 6 1.2 Electrical requirements 1.6 Environmental Conditions 1.7 Miscellanous Table content changed (UL) Page 14 23.01.2017