Operating principle Operating principle XPS LCM safety modules are used with type 4 conforming to EN/ IEC 61496-1 to provide a system inhibiting the light curtain protection, i.e. "muting". This function enables the automatic passage of parts for machining or loaded pallets, without interrupting the transportation movement within the zone protected by the electro-sensitive protection equipment (ESPE) system. In addition to the electro-sensitive protection and XPS LCM safety modules, the system comprises 4 to 8 inhibition sensors, 2 indicator lights and a key switch to reset the system to the initial state in the event of a sequence error. When the system is switched on by the start command and the light curtain protection not interrupted, the main circuit is closed by the safety outputs of the XPS LCM modules (solid-state safety outputs). In addition to safety outputs, the modules incorporate signalling outputs for sending system status information to the PLC. Either 5 or 14 LEDs and a 2-digit display, mounted on the front face of the module, provide information on the safety circuit status. n interruption of the protection fi eld monitored by the electro-sensitive protection equipment causes instantaneous opening of the safety outputs; the process PLC receives a stop command and the LED display mounted on the front face indicates the change of state of the safety circuits. The "open" state is maintained until the module is restarted using the Start button. The "muting" function cannot be activated by supplying the inhibition sensors unless the safety outputs have been switched on beforehand. To trigger the "muting" function, the inhibition devices must be activated within the 3 second time interval. During the activated "muting" phase, materials can be transported through the protection fi eld without deactivating the safety outputs. In the event of intrusion into the hazardous zone, a person cannot activate the inhibition sensors in the same way and the system stops. Whilst the "muting" function is activated, a "muting" status indicator light is controlled by the XPS LCM module. fault at indicator light level (short-circuit, open circuit) is immediately recognised and deactivates the "muting" function. The indicator light only illuminates when a "muting" signal is generated and indicates the inhibition of the protection function. "Muting" indication Hazardous zone Entry direction ESPE (Light curtain) m Materials trolley B C D Materials trolley dm ESPE: electro-sensitive protection equipment (light curtain)., B, D, C: "muting" sensors. m: trolley length and dm = distance between, B and D, C. Conditions to be observed for the "muting" function b The "muting" sensors must either be thru-beam type XUB 0BPSNL2 XUB 0SNL2T, polarised refl ex type XUB 0BPSNL2 XUC Z50 or mechanical limit switches with contacts. b dm m to obtain continuous validation of the "muting" function. b void the intrusion of persons during the "muting" phase. This phase is indicated by the indicator light connected to the "muting" indicator output of the XPS LCM module. b materials trolley must provide the "muting" signal before entering the protection fi eld and cease it once it has cleared all the sensors of the protection fi eld on exiting. Characteristics: page 30311-EN/3 References: page 30311-EN/4 Dimensions: pages 30311-EN/5 Schemes: pages 30311-EN/6 to 30311-EN/9 2
Characteristics Characteristics Module type Maximum achievable safety level (1) PL e/category 4 conforming to EN/ISO 13849-1, SILCL 3 conforming to EN/IEC 62061 Conformity to standards EN/IEC 61496-1, EN/IEC 61496-2, EN/IEC 60204-1, EN/IEC 60947-1, EN/IEC 60947-5-1 Product certifications UL, CS, TÜV mbient air temperature For operation C 0 55 For storage C - 25 75 Degree of protection conforming to IEC 60529 Terminals IP 20 Enclosure IP 20 Power supply Voltage V 24 c Voltage limits - 10 10% Maximum consumption W < 150 Rated insulation voltage (Ui) V 300 (degree of pollution 2 conforming to IEC/EN 60947-5-1, DIN VDE 0110 parts 1 and 2) Rated impulse withstand voltage (Uimp) kv 4 (overvoltage category III, conforming to IEC/EN 60947-5-1, DIN VDE 0110 parts 1 and 2) Number of monitored 1 or 2 transmitter-receiver pairs Inputs for "muting" sensors - number of inputs to be monitored 2 to 4 per "muting" function - supply voltage of sensors V 24 - output current of each sensor m < 20 Type of "muting" sensors Thru-beam, polarised refl ex or sensors with volt-free contacts Synchronisation time of "muting" sensors s 3 or unlimited Maximum "muting" time min 2 or unlimited Safety outputs - number and type 2 (terminals 1 and 2), 0.625 at 24 V - max. thermal current (Ithe) 1 output 2 outputs 2 x 0.108 3 outputs 3 contacts uxiliary outputs 1 (terminal 5) 1 NPN (terminal 6) - breaking capacity of solid-state outputs m 24 V/500 - breaking capacity of solid-state NPN outputs m 24 V/100 "Muting" indicator light power W 1 to 7 max. Response time on input change of state ms 1 Signalling 14 LEDs plus 2-digit display Connection Type Captive screw clamp terminals, removable terminal block 1-wire connection Without cable end Solid cable: 4 mm 2 Without cable end Flexible cable: 0.14...1.5 mm 2 With cable end Without bezel, fl exible cable: 0.14 1.5 mm 2 2-wire connection Without cable end Solid cable: 0.14...1.5 mm 2 (1) Using an appropriate and correctly connected control system. Without cable end Flexible cable: 0.14..0.7.5 mm 2 3
Description, references MPCE/EDM Description To aid diagnostics, the safety monitoring module has 14 LEDs and a 2-digit display on the front face which provide information on the monitoring circuit status. S-1D S-1C S-1B S-1 OSSD 1 OSSD 1B S-2D S-2C Stop Preventa S-2B S-2 OSSD 2 OSSD 2B Interlock RUN 2-digit display References Safety module Description Safety module for "muting" function Type of terminal block connection Number of safety circuits uxiliary outputs Supply Reference Weight Removable 2 1 1 NPN 24 V c 0.660 from module kg Spare parts Description Power Reference Weight W kg "Muting" indicator light kit 5 XSZ CM01 0.012 Replacement bulbs for "muting" indicator light kit comprising one lot of 10 replacement bulbs and 1 removal/insertion tool XBF X13 1 to 7 XSZ CM02 0.016 Presentation: page 30311-EN/2 Characteristics: page 30311-EN/3 Dimensions: page 30311-EN/5 Schemes: pages 30311-EN/6 to 30311-EN/9 4
Dimensions Dimensions Mounting on 35 mm rail Rear view 75 85.6 61.2 110 100 85 (1) "Muting" indicator light kit XSZ CM01 (1) 2 elongated holes Ø 4 x 5.7. 31 44 11 (1) (1) Faston connector 4.7. 5
Connections Connection via the safety monitoring module Example: configuration with XUS LB/LDM N L (2) "Muting" indicator light XUS LB/LDM K1 "Muting" indicator light XUS LB/LDM K2 K2 K1 (1) (1) F1 N L BL8RPS (3) Dedicated power supply 0 V 24 V 0 V 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 S-1D EDM/MPCE S-1C 0 V S-1B S-1 Mu-en-lo OSSD 1B OSSD2 OSSD 1 OSSD1 S-2D S-2C S-2B S-2 OSSD 2B OSSD 2 18 19 20 21 22 23 24 25 26 27 28 29 Receiver XUS LB/LDM MTS EDM/MPCE Mon OSSDB OSSD Mu-en-hi 0 V ux 0 V Transmitter XUS LB/LDM Mu-rm Mu-ux M-Lamp 2 Power supply Inputs Outputs 1 inputs ux. 2 inputs M-Lamp 1 ux NPN Outputs Sensor Sensor Sensor B Sensor B Sensor C Sensor C Sensor D Sensor D (1) rc suppressor. (2) Muting activation/deactivation key switch. (3) The power supply must conform to EN/IEC 61496 and EN/IEC 60204-1 standards. Presentation: page 30311-EN/2 Characteristics: page 30311-EN/3 References: page 30311-EN/4 Dimensions: page 30311-EN/5 6
Connections Connection via the safety monitoring module Example: configuration with 2 XUS LP and XUS LN (2) "Muting" indicator light (XUS LN) "Muting" indicator light (XUS LP) BL 8RPS (4) Dedicated power supply Mu-en-lo Mu-en-hi Mu-rm Mu-ux M-Lamp 2 M-Lamp 1 Power supply Inputs Outputs 1 inputs 2 inputs ux NPN ux Outputs Receiver XUS LPZ Transmitter- Receiver XUS LPB MTS return Transmitter XUS LPZ Transmitter XUS LPZ Transmitter XUS LN Sensor Sensor Sensor B Sensor B Sensor C Sensor C Sensor D Sensor D (1) rc suppressor. (2) Muting activation/deactivation key switch. (3) When module is used with a type 2 light curtain (example: XUS LN), the entire protection system is downgraded to category 2. (4) The power supply must conform to EN/IEC 61496 and EN/IEC 60204-1 standards. 7
Functional diagrams Functional diagram of safety monitoring module "Start/restart interlock" mode with 2 sensors Confi guration of module Power supply Inhibition < 10 mm 1 Light curtain 1 Light curtain interrupted interrupted t < 3 s t < 3 s t < 1 ms t < 1 ms Module alarm Mu-en-hi (12) Inputs Mu-en-Io (13) Start (11) (1) S-1 (21) 1 inputs S-1B (20) OSSD 1 (23) OSSD 1B (22) M-lamp 1 (7) Inhibition outputs Mu-auxiliary (9) Mu-alarm (10) EDM/MPCE (3) OSSD (1) OSSD B (2) Outputs uxiliary uxiliary (5) larm uxiliary uxiliary NPN (6) larm Key 0 1 (1) Press Start button. Presentation: page 30311-EN/2 Characteristics: page 30311-EN/3 References: page 30311-EN/4 Dimensions: page 30311-EN/5 8
Functional diagrams (continued) Functional diagram of safety monitoring module "Start/restart interlock" mode with 4 sensors Power supply Inhibition < 10 mm 1 Light curtain interrupted 1 Light curtain interrupted Confi guration of module t < 3 s t < 3 s t < 1 ms Module alarm Mu-en-hi (12) Inputs Mu-en-Io (13) Start (11) (1) S-1 (21) S-1B (20) 1 inputs S-1C (19) S-1D (18) OSSD 1 (23) OSSD 1B (22) M-lamp 1 (7) Inhibition outputs Mu-auxiliary (9) Mu-alarm (10) EDM/MPCE (3) OSSD (1) OSSD B (2) Outputs uxiliary uxiliary (5) larm uxiliary uxiliary NPN (6) larm Key 0 1 (1) Press Start button. 9