The information in this chapter will enable you to:

Similar documents
Si 2035 Programmable Stepper Drive

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

Advanced Features. High Performance Stepper Drive Description. Self Test and Auto Setup

LN3X Series Motor and Drives

Integrated Stepper Drive & Motor

LNX Series Motor and Drives

A range of brushless servo drives with optional controllers

P7000 Stepper Drives. P7000 Introduction

2Installation CHAPTER TWO IN THIS CHAPTER. Checking Your Shipment Express Setup. Chapter 2 Installation 11

Hybrid AC Driver [GCNC-1110]

Hardware Manual 1240i-485

MD3. Microstepping Motor Driver Page 1 of 7. Description. Software. Mechanical Drawing. Features

In-Sight 7010C/7200C/7400C

I/O Expansion Module Installation & Reference

SMD Series Integrated Stepper Driver and Motor Revision 1.3

User s Manual Hub444. Motion Control Network Hub

ETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features

LVX Control Unit. Features:

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

ZETA6104. Linear Microstepping Motor/Drive Systems. Packaged Drive/Indexer System with L20 Perspective. C Step Motor Systems C81. Catalog /USA

Stepper Motor Driver Board. Instruction Note

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

P-Series Drive Features and Benefits

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

Operation / Installation Manual

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

FEATURES: DESCRIPTION: APPLICATIONS: SPECIFICATIONS: Electrical Specifications of Drive: Operating Environment: [Geben Sie Text ein]

SERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

E101 - Strain Gauge Transducer Display Module. Contents

Series LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver

DTM Distributed Transmitter Monitor

DMX-K-DRV Integrated Step Motor Driver Manual

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

General-Purpose Photoelectric Sensor

Centroid ACORN CNC controller Specification and Use Guide Updated 8/3/17. Overview

STAC5 Stepper Drives. A high performance, compact and cost-effective stepper drive with advanced features and control options

Class 6 Industrial Ethernet

G9SX-LM. Low-speed Monitoring Unit. Low-speed Monitoring Function Ensures Safety for Maintenance Work. Model Number Structure.

ISMD23E2 Series Stepper Motor + Drive + Controller with Integral 2-Port Ethernet Switch

PLC I/O wiring. PLC power supply cable and general control circuit wiring. Power lines. Ground to 100 Ω or less

MDrive Plus Stepper motors with integrated electronics. MDrive 34ac Plus Step / direction input

DSP-BASED MOTOR CONTROLLER FOR THREE-PHASE BRUSHLESS DC MOTORS

Adapter Kit - Remote QSI Electronics Installation Instructions

128MB non-volatile flash memory; unlimited storage via remote network device.

NO: PH-185 PRODUCT: E3JK Photoelectric Sensors DATE: May 2014 TYPE: Discontinuation Notice

SYSTEMS ELECTRONICS GROUP

INTEGRATED MICROSTEPPING MOTOR DRIVER AND HIGH PERFORMANCE MACHINE/PROCESS CONTROLLER

PACKAGED STEPPER SYSTEMS. API Controls

The information in this chapter will enable you to: Understand the product's basic functions & features

Easy To Use OEMS Take Note

895/896M Frequency Output Math Modules

TM241CEC24R controller M IO relay Ethernet CAN master

RS03/06-P Quick Setup Guide

ILS1M851PB1F0 integrated drive ILS with stepper motor V - I/O for motion sequence - 5A

Optical Encoders. Sold & Serviced By: Toll Free Phone: Toll Free Fax:

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

The Model 464-BC Monitor controls and stores flow data from Marsh- McBirney Flo-Dar sensors. A portable computer and Flo-Ware software is used to

KNC-SRV-FD332S Servo Driver

34ac. Excellence in MotionT

Adapter Kit - QSI Electronics to TM Meter Installation Instructions

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Andover ContinuumTM Infinet II

Delivery. Connection. C. AA+BB Helicoidal cable 2. Radial M12 8p CCW. 3. Radial M23 12p CCW

uservo box instruction manual

TXM24 RS232/485. Integrated Step-Servo Motor. Hardware Manual Rev. D

MDrive Plus Stepper motors with integrated electronics. MDrive 14 Plus Step / direction input

Hardware Manual Si3540

SmartFan Fusion-4. Speed Control and Alarm for DC Fans CONTROL RESOURCES INCORPORATED. The driving force of motor control & electronics cooling.

The SilverNugget is a servo controller/driver for NEMA 17 & 23 frame microstep motors.

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

P216 Series Condenser Fan Speed Controller

Brushless Motor with Integral Drive EnduraMax 95i Series

RoboClaw 2x30A Dual Channel Motor Controller

Safety Monitoring Relays

Instruction Manual for BE-SP3 Circuit. 10/21/07

Requires QuickControl v6.22 or greater to initialize and program SilverMax servo.

Simplified information where and how you want it.

NETRONICS HS3500 CONTROLLER

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

FEATURES DESCRIPTION FEATURES

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A...

Hardware Manual 1240i

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

Stellar Instruments. SC1 Controller & Display System. General User s Manual. Copyright 2013 Stellar Instruments 1

SCD96 DMX Output Interface. Installation guide

MDrive Hybrid Integrated motion systems with Hybrid Motion Technology. MDrive 17 Hybrid Motion Control

MDrive Plus Stepper motors with integrated electronics. MDrive 34 Plus Motion Control fully programmable

TM241C40R controller M IO relay

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

intelligent motion systems, inc. Excellence in Motion TM OPERATING INSTRUCTIONS

EMS467 Monitoring System. Installation and Operations Manual Section 40

MaxStepper Serial Step and Direction Pulse Generator. User Manual

MDrive Plus Stepper motors with integrated electronics. MDrive 17 Plus Step / direction input

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

EM705 2-phase Digital Stepper Drive

The information in this chapter will enable you to:

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

Transcription:

C H A P T E R ➅ Hardware Reference The information in this chapter will enable you to: Environmental Specifications Use this chapter as a quick reference tool for most system specifications Use this chapter as a quick reference tool for most switch settings Use this chapter as a quick reference tool for proper I/O connections Parameter Operating temperature Drive temperature Motor temperature Storage temperature Humidity Drive Electrical Specifications Input power Output Power Range 0 to 40 C (32 to 104 F) ambient Maximum heatsink temperature 75 C (162 F) Maximum motor case temperature 100 C (212 F) -40 to 85 C (-40 to 185 F) 0 to 95% non-condensing Parameter Low Power High Power Voltage 110-130VAC* 100-130VAC, single phase Frequency 47-66 Hz 47-66 Hz Current 8.5 amps max continuous (RMS) 8.5 amps max continuous (RMS) 110VAC-130VAC is supplied to the transformer included with the low power Compumotor Plus. Parameter Low Power High Power Voltage 50VDC peak 170VDC peak Frequency 20 khz (PWM) 20 khz (PWM) Current Continuous 7 amps continuous 7 amps continuous Current Peak 8.5 amps peak 8.5 amps peak ➅ Hardware Reference 121

Connector Summary Motor & Power Connector, Low-Power Drive Signal Name In/Out Type Current Voltage Frequency Wire Color 1 T1 Input Power 4A 36VAC 50/60 HZ Brown 2 T2 Input Power 4A 36VAC 50/60 HZ Blue 3 GND Input Power 4A Earth N/A Grn/yel 4 A+ Output Motor 8A 50VAC N/A Red 5 A- Output Motor 8A 50VAC N/A Black 6 GND Output Motor 8A 0VAC N/A Shield 7 B+ Output Motor 8A 50VAC N/A White 8 B- Output Motor 8A 50VAC N/A Green Motor & Power Connector, High-Power Drive Signal Name In/Out Type Current Voltage Timing Wire Color 1 LINE Input Power 6A 115VAC 50/60 HZ Black 2 NEUT Input Power 6A 115VAC 50/60 HZ White 3 GND Input Power 6A Earth N/A Green 4 A+ Output Motor 10A 150VDC N/A Red 5 A- Output Motor 10A 150VDC N/A Black 6 GND Output Motor 10A Earth N/A Shield 7 B+ Output Motor 10A 150VDC N/A White 8 B- Output Motor 10A 150VDC N/A Green Control Connector, Low Power & High Power Drives Current (Min) Voltage (Max) Signal Name In/Out Type Timing 1 Rx Input RS-232C - ±15V 9600 Baud (adjustable) 2 Tx Output RS-232C - ±15V 9600 Baud (adjustable) 3 GND - GROUND - Earth - 4 ENABLE Input SRC 12 ma 12V DC 5 CW LIMIT Input SRC 12 ma 12V DC 6 CCW LIMIT Input SRC 12 ma 12V DC 7 RESET Input SRC 12 ma 12V DC 8 GND Input Ground - - - 9 COMMAND 1+ Input (Step+) 10 COMMAND 1- Input (Step -) Non-indexing 11 COMMAND 2+ Input (Dir +) Version Only 2 COMMAND 2- Input (Dir --) 13 MONITOR + Output Analog 10mA ±10V 14 MONITOR - Output 15 FAULT + Output OC 50mA 30V DC 16 FAULT - Output OE I/O Connector, Low and High Power Drives Signal Name In/Out Type Current Voltage 1 OUT 1+ Output OC 50 ma (Max) 30V 2 OUT 1- Output OE 3 OUT 2+ Output OC 50 ma (Max) 30V 4 OUT 2- Output OE 5 HOME Input SRC 12 ma (Min) 12V 6 TRIG 1 Input SRC 12 ma (Min) 12V 7 TRIG 2 Input SRC 12 ma (Min) 12V 8 TRIG 3 Input SRC 12 ma (Min) 12V 9 SEQ 1 Input SRC 12 ma (Min) 12V 10 SEQ 2 Input SRC 12 ma (Min) 12V 11 SEQ 3 Input SRC 12 ma (Min) 12V 12 GND Input GND 122 Compumotor Plus TM User Guide

+ I/O Diagram +5 to 30 VDC OUT 1+ OUT 1- OUT 2+ OUT 2- HOME TRIG 1 TRIG 2 TRIG 3 SEQ 1 SEQ 2 SEQ 3 GND N.O. Switches DC Common + - + - Electronic Relay Electronic Relay I/O Schematics +12V 1K ILQ2 Input 0.001uF Schematic for the following I/O: CW LIMIT, CCW LIMIT, ENABLE, RESET, HOME, TRIG1, TRIG2, TRIG3, SEQ1, SEQ2, SEQ3 + 100Ω HCPL2631 464Ω Schematic for the following I/O: COMM AND1, COMMAND2 ILQ2 10K Schematic for the following I/O: FAULT, OUT1, OUT2 ➅ Hardware Reference 123

I/O Specifications Position sensor: Accepts position information from the motor's built-in resolver. The cable between the motor and drive is prewired at the factory. CAUTION The position sensor connector on the low and high power drives are not normally accessed by user. Un-isolated hazardous voltages are present in high power units. Various length cables are available (consult the factory). Input power: Motor connections: Input power for the drive-high-power: 110VAC, lowpower drive: 36VAC. The low-power drive is provided with a pre-wired 110VAC input, 36VAC output transformer. T1 One phase of the input power (Brown) T2 Second phase of the input power (Blue) GND Earth ground (Green/Yellow) Output power to the motor. Up to 150VDC for the high-power drive and 50VDC (pulsed) for the low power drive. A+ Plus side of motor phase A (Red) A- Minus side of motor phase A (Black) RS-232C Connections Discrete Control Connections GND Shield ground B+ Plus side of motor phase B (White) B- Minus side of motor phase B (Green) The RS-232C transmits and receives connections. It accepts standard EIA RS-232C signals from +15V to -15V. The baud rate is selectable. Eight data bits, no parity, and one stop bit are fixed parameters. The unit is optically isolated. Tx, Rx and Gnd The RS-232 connections are labeled Tx for transmit, Rx for receive and Gnd for ground. These input and output signals control various dedicated functions of the Compumotor Plus as explained below. The unit is optically isolated. Enable Enable Input. Enables the drive. Must be connected to isolated signal ground for drive operation. CW LIMIT CW end-of-travel limit. This input must be connected to ground to be inactive. CCW LIMIT CCW end-of-travel limit. This input must be connected to ground to be inactive. RESET When the reset line is connected to ground, the reset line of the microprocessor is pulled low and the system resets. GND Isolated signal ground or common COMMAND 1+ Step Input: The step pulse input to the step/direction Compumotor Plus Drive. Not used in the Indexer version. COMMAND 1- Step Return: The step pulse input return for the Step/Direction Compumotor Plus Drive. Not used in the Indexer version. COMMAND 2+ Direction Input: The direction signal input for the Step/Direction Compumotor Plus Drive. Not used in the Indexer version. COMMAND 2+ Direction Input: The direction signal input for the Step/Direction Compumotor Plus Drive. Not used in the Indexer version. MONITOR + Bipolar analog output (+10V) providing analog velocity report. -10V equates to -50 revolutions per second, 0V equates to zero speed, and +10V equates to +50 revolutions per second. MONITOR - Isolated ground for monitor output. FAULT+ Fault indication output plus. Turns off (no current) to indicate fault condition. (Collector of optically isolated transistor.) FAULT- Fault indication output minus. (Emitter of optically isolated transistor.) 124 Compumotor Plus TM User Guide

Discrete Input/Output connections OUT 1+ OUT 1- OUT 2+ OUT 2- HOME TRIG 1 TRIG 2 TRIG 3 SEQ 1 SEQ 2 SEQ 3 GND Input Output Specifications Quick Reference Inputs and outputs that affect program control. They are optically isolated. General purpose output #1 plus. Controlled by O and IO command (collector of optically isolated transistor). General purpose output #1 minus (emitter of optically isolated transistor). General purpose output #2 plus. Controlled by O and IO command (collector of optically isolated transistor). General purpose output #2 minus (emitter of optically isolated transistor). Home input. Indicates home position. Used in conjunction with the Go Home command (GH). General purpose input #1. Used in conjunction with the trigger commands (TR, TS) and sequence inputs in IM2. General purpose input #2. Used in conjunction with the trigger commands (TR, TS) and sequence inputs in IM2. General purpose input #3. Used in conjunction with the trigger commands (TR, TS) and sequence inputs in IM2. Sequence control input. Commands a specific sequence number to be executed. Refer to the Execute (X) commands. Sequence control input. Commands a specific sequence number to be executed. Refer to the Execute (X) commands. Sequence control input. Commands a specific sequence number to be executed. Refer to the Execute (X) commands. Logic ground. The types of Compumotor Plus inputs and outputs are listed in the table below. Type BLNCD GROUND RS-232C SNK OC OE Description Balanced input. Requires both a plus and minus to activate Isolated ground for logic signals Standard RS-232C I/O. Optically isolated. Sinking input. Optically isolated, requires a ground to activate Open collector output. Optically isolated Open emitter output. Optically isolated. Used with open collector output ➅ Hardware Reference 125

Dimensional Drawings CPL, CPLX 8.26 3.92 3.44 (87.38) (209.80) 8.13 (206.50) 1.55 (39.37) (99.57) Optional Mounting Bracket Location 12.84 (326.14) 11.90 (302.26) 13.14 (333.76) Right Side View Dimension Low Power Drive Height 11.9 (302.3) Drive Width 3.92 ( 99.6) Drive Depth 8.13 (206.5) Weight 11.5 lbs (5.2 Kg) Front View Provision for #10 Mounting Screws CPH & CPHX 4.99 (126.75) 4.90 (121.92) Front 1.77 (44.96) Provision for #10 Mounting Screws Top View Front View 13.14 (333.76) 12.84 (326.14) 11.90 (302.26) 11.90 (302.26).47 (11.94) Dimension High Power Drive Height 11.9 (302.3) Drive Width 4.787 (121.6) Drive Depth 8.13 (206.5) Weight 15.2 lbs (16.9 Kg) 8.34 (211.84) 4.88 (123.95) 8.13 (206.5).98 (24.89) 126 Compumotor Plus TM User Guide

Motor Dimensions CP57-120 Motor 2.25.75 Ref (19.05) 1.75 (44.45) 4.75 Max. (120.65) 1.95 ±.04 (49.53 ± 1.02).81 ±.03 (20.57 ±.76).19 (4.83) 2.35 Max (59.69).06 (1.52) 2.25 Body Dia. (4).205 ±.010 (5.21 ± 0.25) Holes Eq.Sp. on a 2.625 (67.31) D BC..2500.2495 (6.3500) (6.3373) 2.25 Sq. 1.86 Sq. (47.24) Note: Cable connectors extend beyond back of motor 1.500 ±.002 (38.1 ± 0.051) CP83-150 Motor 2.25.1.19 (30.213) 1.75 (44.45) 5.89 Max. (149.61) 2.61 ±.04 (69.29 ± 1.02) 1.19 ±.03 (30.23 ±.76).19 (4.83) 2.93Max (74.42).06 (1.52) 2.875 ±.002 (73.025 ± 0.051) (4).22 (5.59) D Holes Eq.Sp. on a 3.875 (98.42) D BC. 3.38 (85.85) Body Dia..3750.3745 (9.525) (9.512) 3.25Sq. (82.55) 2.74Sq. (69.59) CP106-220 Motor 3.00 (76.20) Bendix PTO ZE 12-10P (Mtr) PTO ZE 10-6S (Res.) Connectors 8.40 Max. (213.36) 2.25 4.68 ±.04 (118.87 ± 1.02) 1.38 ±.03 (35.05 ±.76) Mtr Res..32 ±.04 (8.13 ±1.02) M76 Holes, Opp End (Ref) 3.75Max (95.25).500.499 (12.70) (12.67).06 (1.52) (3) #10-32 Eq Sp on a 300 (76.2) D BC..38 (9.65) DP Min. 2.186 ±.002 (55.524 ± 0.051) (4).28 ±.01 (7.11 2 0.25) Dia Holes Eq.Sp. on a 4.950 (125.73) D BC. 4.19Sq. (106.43) 3.500Sq. (88.90) 4.25 (107.95) Body Dia. ± 6.08 (31.75 ± 2.03).6250.6245 (15.875) (15.862) Motor Specifications Specification CPL57-120 CPL83-150 CPH83-150 CPH106-210 Torque (continuous) 130 370 370 1100 in-oz Torque (peak) 160 420 420 1400 in-oz Max continuous speed 3600 3600 3600 3600 rpm Rotor Inertia 0.0042 0.0239 O.0239 0.1393 oz-in-sec 2 System Specifications Accuracy & Repeatability Physical Description Value Repeatability ± 2 arc min. (0.0334 ) Accuracy ± 12 arc min. (0.200 ) Bi-directional, loaded at 80% of total torque. (With proper tuning) Description CPL57-120 CPL83-150 CPH83-150 CPH106-210 Motor Weight 3.2 7.7 7.7 21.7 Shipping Weight 20.0 25.0 25.0 45.0 ➅ Hardware Reference 127

Torque/Speed Curves CPL57-120 or CPLX57-120 CPL83-150 or CPLX83-150 lb-in (N-m) lb-in (N-m) 140 8.75 (0.98) 500 3 (3.50) 120 100 80 7.5 6.25 5.00 (.84) (.70) (.56) 400 300 25.00 18.75 (2.80) (2.00) 60 3.75 (.42) 200 12.50 (1.40) 40 20 2.50 (.28) (.14) 100 6.25 (0.70) 0 0 1 2 5 8 10 15 20 25 30 40 50 Velocity-Rev/Sec. 1 2 5 8 10 15 20 25 30 40 50 Velocity-Rev/Sec. 500 CPH83-150 or CPHX83-150 CPH106-220 or CPHX106-220 lb-in (N-m) lb-in (N-m) 3 (3.50) 1200 75.00 (8.40) 400 25.00 (2.80) 1000 62.50 (7.00) 300 18.75 (2.00) 800 50.00 (5.60) 200 12.50 (1.40) 600 37.50 (4.20) 100 6.25 (0.70) 400 200 25.00 12.50 (2.00) (1.40) 0 1 2 5 8 10 15 20 25 30 40 50 Velocity-Rev/Sec. 0 1 2 5 8 10 15 20 25 30 40 50 Velocity-Rev/Sec. 128 Compumotor Plus TM User Guide