New Enhanced Multi-frame DICOM CT and MR Objects to Enhance Performance and Image Processing on PACS and Workstations

Similar documents
Impact of New DICOM Objects on Handling Large Data Sets

Enhanced DICOM MR for spectroscopy, structural and functional imaging

New Modality Issues: DICOM Enhanced Images CT, MR, PET, XA/XRF

Enhanced Multi-frame Images The New Core Paradigm for DICOM

Technical Publications

Digital Imaging and Communications in Medicine (DICOM)

DICOM Overview: Stability and Evolution

Lossless Compression of Breast Tomosynthesis Objects Maximize DICOM Transmission Speed and Review Performance and Minimize Storage Space

Technical Publications

Digital Imaging COmmunications in Medicine. DICOM in a Nutshell

Technical Publications

Technical Publications

Conformance Statements for DICOM PaCentric Connect / Traveler

Technical Publications

Caseaccess 1.0 DICOM Conformance Statement

DICOM Research Applications - life at the fringe of reality

DICOM Correction Item

C-DAC s Medical Informatics Software Development Kit (SDK) for DICOM PS Conformance Statement

Technical Publications

InstaPACS / InstaRISPACS / InstaViewer (v Release) DICOM Conformance Statement. Meddiff Technologies Pvt. Ltd.

Technical Publications

DICOM Conformance Statement

DICOM Correction Item

Technical Publications

Technical Publications

Acuo VNA. DICOM Conformance Statement Version 6.0 March 2018

Technical Publications

Software Version 6.0 DICOM Conformance Statement

X-Porte DICOM Conformance Statement

Technical Publications

Informatics I - The digital breast image interoperability and management

Topcon Medical Systems

Technical Publications

DICOM Conformance Statement * /02* /02 MADE IN GERMANY

DBSWIN DICOM Conformance Statement. DBSWIN DD-DICOM Interface. DICOM Conformance Statement V2.1

Technical Publications

Technical Publications

DRS DICOM Software V1.2 GE Medical Systems. DICOM V3.0 (ID/Net V3.0) REV 4 Conformance Statement

Digital Lightbox 1.0

STaR. DICOM Conformance Statement. September 2009 Version NO COPIES PERMITTED

Technical Publications

Technical Publication. DICOM Conformance Statement. Patient Browser 2.1. Document Revision 2. April 13, Copyright BrainLAB AG

DICOM Conformance Statement. EasyGuide R2.1

PACS and DICOM. Einar Heiberg,

Compression of 3-Dimensional Medical Image Data Using Part 2 of JPEG 2000

Medical Image Processing: Image Reconstruction and 3D Renderings

StellarPACS DICOM Conformance Statement. Version 1.3, August 2008 SoftTeam Solutions

ETIAM Nexus. DICOM Conformance Statement.

Technical Publications

Version 7 DICOM Conformance Statement. Document Version 3.02, June 2009

Technical Publications

DICOM CONFORMANCE STATEMENT FOR TOSHIBA DIGITAL RADIOGRAPHY SYSTEM. Infinix Celeve-i series / Infinix-i series Model XIDF-3DP801 AND ANGIO WORKSTATION

Version 9 DICOM Conformance Statement. Version 3.05, September 2015

Visage. DICOM Conformance Statement

DICOM Conformance Statement

PACSware Migration Toolkit (MDIG)

Technical Publications

Digital Imaging and Communications in Medicine (DICOM) Supplement 167: X-Ray 3D Angiographic IOD Informative Annex

Technical Publications

EOS. EOS imaging system. DICOM Conformance Statement [1]

Technical Publications

RamSoft. PowerServer. DICOM Conformance Statement

Uscan. DICOM Conformance Statement

DICOM Conformance Statement. isite PACS 4.1. CREF Nov 23. Philips Healthcare Informatics

Senographe Essential Acquisition System

Technical Publications

DICOM Conformance Statement

HCP DICOM Net DICOM Conformance Statement

Technical Publications

DICOM CONFORMANCE STATEMENT

Digital Breast Tomosynthesis PACS/Workstation Vendor Perspective. Ron Muscosky Product Line Manager for Carestream Health

Sep, th Edition 897N101668H

Technical Publications

Technical Publications

MediPlus TM PACS&RIS Version 2.6

DICOM V3.0 Conformance Statement. SenoIris 1SP2

DICOM Conformance Statement. CT AV Series Product Line. Document Number February 1997

DICOM Conformance Statement for Scanner Interface. Release 4.7.1

Interoperability Issues in Image Registration and ROI Generation

Technical Publications

Technical Publications

Technical Publications

SYNAPSE 3D Conformance Statement FUJIFILM SYNAPSE 3D V3.0. Conformance Statement. Revision Z45N

Technical Publications

Technical Publications

Technical Publications

Technical Publications

Technical Publications

The DICOM Standard. Miloš Šrámek Austrian Academy of Sciences

Perennity AccessBox DICOM Conformance Statement

Technical Publications

FusionXD 2.1 DICOM Conformance Statement

DICOM Conformance Statement. cvi 42. Version 5.6. Workstation for Cardiovascular MR and CT

Technical Publications

DICOM Conformance Statement

Technical Publications

Technical Publications

Punctual Dicom Workstation

Specification. Field: R&D Number: RD2F00244 Version: C Subject: TraumaCad DICOM Conformance Statement Page 1 of 10. Name Position Date Signature

Unified Clinical Archive Version 9.5. DICOM Conformance Statement

Transcription:

New Enhanced Multi-frame DICOM CT and MR Objects to Enhance Performance and Image Processing on PACS and Workstations SCAR 2004 Hot Topics - 22 May 2004

David Clunie, RadPharm Charles Parisot,, GE Healthcare Kees Verduin,, Philips Medical Systems Bernhard Hassold,, Siemens Medical Solutions

Greater Expectations Previously, users content with viewing + annotations Increasingly advanced applications Hanging protocols, MPR, 3D, virtual colonoscopy Perfusion, diffusion, functional MR, spectroscopy Cardiac cine, CT and MR fluoroscopy Lung CAD Such applications are often vendor-specific Performed on console or same vendor s workstation Depend on private attributes Want advanced application interoperability Support in multi-vendor PACS workstations Distributing screen saves on PACS insufficient

Why are new objects needed? CT and MR objects more than 10 years old Technology on which they are based probably more than 15 years old Pre-date many technological advances Helical CT & fast spin echo pulse sequences Explosion in data set size -> performance? Multi-detector CT and functional MR Expectations beyond simple viewing Hanging protocols & advanced applications

New Multi-frame CT & MT Potential performance gain during transfer & loading Easier access to organized multi-slice data Preservation of intended semantics of acquisition (e.g. a volume set, a cine run) More extensive, up-to-date acquisition parameters Additional features for special acquisition and analysis types color values, e.g. for functional data overlaid on structure real world value mapping, e.g. ADC, velocity Specialized data interchange, and central archiving Spectroscopy and raw data

Performance Opportunities New multi-frame object does not change TCP connection establishment Association establishment Common header information is not repeated But reduction is negligible compared to pixel data size Reduced latency (delay) between storage requests Creates opportunity for inter-slice (3D) compression Extremely implementation-dependent

A s s o c i a t i o n C-Store request Dataset (attributes+pixels) C-Store response (acknowledgement)

A s s o c i a t i o n DB UIDs Store, parse, check C-Store request Dataset (attributes+pixels) C-Store response (acknowledgement)

A s s o c i a t i o n DB UIDs DB Store, parse, check C-Store request Dataset (attributes+pixels) C-Store response (acknowledgement)

A s s o c i a t i o n DB DB DB UIDs Store, parse, check C-Store request Dataset (attributes+pixels) C-Store response (acknowledgement)

A s s o c i a t i o n DB DB DB DB UIDs Store, parse, check C-Store request Dataset (attributes+pixels) C-Store response (acknowledgement)

CTA - 548x512x512 (275MB) File read/transfer/save (GB Ethernet) 25 20 Time in seconds 15 10 5 0 Single Frame 1 1=DICOM, 2=DICOM, 3=HTTP 2 3 Multi Frame 1 2 3 Multi Frame 11.14111111 14.86703704 13.07333333 Single Frame 16.905 17.97 23.42666667

Lossless JPEG 2000 Compression (Alexis Tzannes, Aware, 2003) 4 3.5 3 2.5 Compression Ratio 2 1.5 1 0.5 0 single 20 40 80 all 127x256x8 7.9MB 2.073490814 2.415902141 2.430769231 2.438271605 2.445820433 449x512x16 224MB 2.955145119 3.572567783 3.595505618 3.607085346 3.624595469 620x512x16 310MB 2.583333333 2.952380952 2.980769231 3.069306931 3.1 Slices in 3rd dimension

Organizational Features Multi-frame pixel data Comprehensive, mandatory, coded attributes Shared and per-frame functional groups Compact & makes explicit what doesn t change Dimensions a priori hints as to how the frames are organized Stacks Temporal positions Concatenations Reasonable size chunks, viewing in batches as acquired

Multi-frame Functional Groups Shared attributes Per-frame attributes Pixel data

Concatenations Shared attributes Per-frame attributes Pixel data

Robust Application Support More technique-specific attributes Majority of them mandatory for original images More technique-specific terms Categorizing acquisition types Describing acquisition parameters Less dependence on private attributes Better organization of data

Technique Attributes & Terms CT MR SOP Class Original Enhanced Original Enhanced Attributes (Mandatory) 18 (0) 41 (39) 44 (2) 103 (94) Terms (Enumerated) 4 (2) 86 (18) 38 (9) 228 (47)

CT Image Type Value 3 Original SOP Class AXIAL or LOCALIZER Enhanced SOP Class Common to CT and MR ÿangio, FLUOROSCOPY, LOCALIZER, MOTION, PERFUSION, PRE_CONTRAST, POST_CONTRAST, REST, STRESS, VOLUME CT-specific ÿattenuation, CARDIAC, CARDIAC_GATED, REFERENCE

Organization of Data Shared and Per-frame Functional Groups Each functional group contains attributes that likely vary as a group, e.g. Pixel Measures, Plane Orientation, Velocity Encoding, etc. Dimensions Specify intended order of traversal, such as space, then time (e.g., for cardiac cine loops) Stacks Groups of spatially-related slices, repeatable Temporal Position Index

5 4 Stack ID 3 2 1 1 2 3 4 In-Stack Position 5

Dimensions Start with a dimension of space. A set of contiguous slices through the heart. Stack ID = 1 11 22 33 In-Stack Position 44 55 Space

Trigger Delay Time Temporal Position Index Stack ID = 1 Add dimension of time (delay time from R-wave). 48 ms 2 11 22 33 In-Stack Position 44 55 Sets of contiguous slices throughout cardiac cycle. Stack ID = 1 Time 0 ms 1 11 22 33 In-Stack Position 44 55 Space

Trigger Delay Time Temporal Position Index Stack ID = 1 1 \\ 5 \\ 2 Dimension Index Values 48 ms 2 11 22 33 In-Stack Position 44 55 Stack ID = 1 Dimension Index Pointers: 1. Stack ID 2. In-Stack Position 3. Temporal Position Index Time (2) 0 ms 1 11 22 33 In-Stack Position 44 55 Space (1)

Trigger Delay Time Temporal Position Index Stack ID = 1 1 \\ 5 \\ 2 Dimension Index Values 48 ms 2 In-Stack Position 55 1\5\2 44 1\4\2 33 1\3\2 22 1\2\2 11 1\1\2 Stack ID = 1 Dimension Index Pointers: 1. Stack ID 2. In-Stack Position 3. Temporal Position Index Time (2) 0 ms 1 In-Stack Position 55 1\5\1 44 1\4\1 33 1\3\1 22 1\2\1 11 1\1\1 Space (1)

Trigger Delay Time Temporal Position Index Stack ID = 1 2 \\ 1 \\ 5 Dimension Index Values 48 ms 2 In-Stack Position 55 2\1\5 44 2\1\4 33 2\1\3 22 2\1\2 11 2\1\1 Stack ID = 1 Dimension Index Pointers: 1. Temporal Position Index 2. Stack ID 3. In-Stack Position Time (1) 0 ms 1 In-Stack Position 55 1\1\5 44 1\1\4 33 1\1\3 22 1\1\2 11 1\1\1 Space (2)

Trigger Delay Time Temporal Position Index Stack ID = 1 2 \\ 1 \\ 5 Dimension Index Values 48 ms 2 In-Stack Position 55 2\1\5 44 2\1\4 33 2\1\3 22 2\1\2 11 2\1\1 Stack ID = 1 Dimension Index Pointers: 1. Trigger Delay Time 2. Stack ID 3. In-Stack Position Time (1) 0 ms 1 In-Stack Position 55 1\1\5 44 1\1\4 33 1\1\3 22 1\1\2 11 1\1\1 Space (2)

Organization of Data Goal is to reduce the work that the receiving application has to do to figure out How the data is organized Why it is organized that way Without preventing use of the data in unanticipated ways E.g. 3D on a dataset not intended as a volume Two levels The detailed shared & per-frame attributes The overall dimensions, stacks and temporal positions

Color Information

Spectroscopy Storage of Spectroscopy Data Metabolite Maps

But when? Modality PACS

NEMA Initiatives MR test tools, images and spectra available CT test tools and images in development Implementation testing & demonstration In conjunction with SCAR May 2004 - call for participation Dec 2004 - commitment by vendors Jun 2005 - SCAR demonstration

Not Just MR & CT? Need for new multi-frame PET object Currently single slice Much renewed interest in PET-CT fusion To be assessed during SNM June 2004 meeting X-ray angiography work in progress Support for digital detectors New acquisition types Tomosynthesis

Summary Primary goal of new CT & MR objects is to support inter-operability of advanced applications between multiple vendors between modalities, workstations & PACS New objects simplify the task of a receiving application by providing guidance through multidimensions Adoption requires commitment by modality, workstations and PACS vendors DICOM, NEMA & SCAR promoting collaboration