Andover ContinuumTM Infinet II

Similar documents
Andover ContinuumTM Infinet II

Andover ContinuumTM Infinet II

Andover ContinuumTM. b3850 Series Terminal Controllers

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

BACnet. b3810 Series Local Controllers

BACnet. b3867 Terminal Controllers

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

The Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box

Andover ContinuumTM Infinet II

lighting control. Each controller switches up to 48 high voltage, 20-amp lighting circuits, using

Andover Continuum. Power Supplies with or without UPS

using optional EMX 190 expansion modules), and makes access decisions based on its own distributed

ACX Series. Access Controller for Ethernet

XT-9100 Technical Bulletin

Specification Sheet For electronically commutated motors

Andover ContinuumTM. Family of Controllers. BACnetTM

FX Input/Output (I/O) Modules XM07 and XM14

Andover ContinuumTM. Family of Security Products

TAC I/NETTM 1284, 1280, Security Control Unit

Installation Instructions for UL Rev A

Andover Continuum. Family of Security Products

ECB-300 Series BACnet B-AAC 18-Point Programmable Controllers

TAC Xenta 301. Controller, Freely Programmable

clarity 3 Programmable Controller

TALON Network Manager- 2 & 6 Express

DS Type: MAXIM III Controller

Datasheet. ECB-600 and ECx-400 Series. ECB-600 & ECx-400. Overview. Applications. Features & Benefits.

DX-9100 Digital Controller, Version 2

PEAK TM. PEAK TM controllers. Mid-Market BAS Smart equipment controllers. HVAC/R controllers

FX06 Field Controller

LX Series Free Programmable Controllers

DS October MAXIM 1010 Controller

Datasheet. ECB-PTU Series. 1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

AIR HANDLING UNIT CONTROLS

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

8 channel universal input and 4 channel Form C digital output

Quick Start Installation Guide

BACnet Controller for General-purpose Building Applications

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

Datasheet. ECB-300 Series. 1/6. BACnet B-AAC 18-Point Programmable Controllers. Overview

RTD-W Installation Instructions

Extended Digital Controller

BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

TAC Xenta 121-FC Programmable Fan Coil Application

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

TX-I/O Product Range. Description. Technical Specification Sheet Document No February 20, 2018

TX-I/O Product Range. Description. Technical Specification Sheet Document No July 18, 2013

Hotel Room Controller

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

Carbon Monoxide (CO) Gas Detection and Control System

Datasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview

PXC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1.1, May 2007

Multi-Point Gas Detection and Control System

TC Compact Series Unitary Equipment Controller

TM221M16R controller M IO relay

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

TAC Xenta 121-HP Programmable Heat Pump Application

CBX System. CBX System TECHNICAL DATASHEET & INSTALLATION GUIDE DESCRIPTION APPLICATION

TC Modular Series for BACnet Networks

Multi-Point Gas Detection and Control System

Easy To Use OEMS Take Note

FCU-MULTI Modbus Fan Coil Unit Controller

AIAS. Technical description

TM221CE40R controller M IO relay Ethernet

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.

FCU-4 FAN COIL CONTROLLER

TM221CE24R controller M IO relay Ethernet

IQ21x Series Controllers

Multi-Point Gas Detection and Control System

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

Smart Equipment Controls (SEC)

TM221ME32TK controller M IO transistor PNP Ethernet

Compact Series Unitary Equipment Controller

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

Multi-Point Digital Gas Detection and Control System

TX-I/O Product Range. Features. Description. Document No January 24, 2007

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

MOD-RI Room Interface Modules with Modbus

TM241C40U controller M IO transistor NPN

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Power Panel. Terminal block, 12 pin, 20 pcs., cage clamps. Table 5: Order data for PP41

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

TX-I/O Product Range. Features. Description. Technical Specification Sheet Document No January 24, 2007

TM221CE40T controller M IO transistor PNP Ethernet

TM241C24T controller M IO transistor PNP

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

TM241C40R controller M IO relay

Measure & Control Temperature & CO2 levels with analog & digital I/O

Siemens BACnet Programmable TEC Unit Vent Controller for Smoke Control

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Datasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

PXC Modular Series. Features. Description. Technical Specification Sheet Document No July 24, 2012

Local LCD HMI - View and force I/O, and make simple configuration changes without a computer!

ECP-VAV Series. ECP-VAV Series. 10-Point Single Duct VAV / VVT Free Programmable Controller. Applications. Features

Transcription:

Andover ContinuumTM Infinet II i2920 System Controllers The Andover Continuum Infinet II i2920 System Controller is designed to meet the needs of your most demanding control and monitoring applications with its versatile input/output mix and its ability to add additional points using xp Expansion Modules.

Features 02 Designed for control of large Air Handling Units, chillers, boilers, and other mechanical plant equipment, the i2920 features plenty of dynamic memory for application programs as well as for expanded local data logging of critical data. The i2920 also features a fast 32-bit processor, universal inputs, override switches on all outputs, two-piece removable connectors, and an optional 4-line display with keypad. Similar to other Andover Continuum Infinet II controllers, the i2920 has an additional room sensor input, which supports Andover Continuum Smart Sensor, or any standard room temperature sensor. Product AT A GLANCE Compatible with Both Andover Continuum and Infinity Systems Powerful, Flexible System Controller for the Most Demanding Applications Expandable I/O Meets Additional Point Count Needs Non-Volatile Flash Memory Provides Utmost Reliability Stores Both Application Program and Operating System Optional Local Display/Keypad Provides Easy Operator Interface Local, Extended Storage of Log Data View and Modify Information with Optional Smart Sensor Display Local, On-Board Service Port The i2920 communicates with the entire Andover Continuum Infinet RS-485 field bus; i.e., both Andover Continuum Infinet and Andover Continuum Infinet II controllers, and is compatible with both the Andover Continuum CyberStation TM and Infinity TM SX 8000 front-ends. Up to 254 Andover Andover Continuum Infinet devices can be networked to any Andover Continuum network controller. Increased Reliability with Flash Memory The i2920 s non-volatile Flash memory stores your operating system and application programs, so that in the event of a power loss, your application will be restored when power is returned. In addition, the Flash memory allows for easy upgrades of your operating system via software downloads, eliminating the need to swap out proms. The i2920 controllers include an on-board battery to safeguard your runtime data protecting all point data and log data from being lost if power is removed. Inputs The input configuration on the i2920 series consists of sixteen full range, 12-bit Universal inputs that accept voltage (0-10VDC), digital (on/off), counter signals (up to 4Hz), temperature signals, or supervised alarm circuits for security applications. The i2920 offers an additional input to support the Andover Continuum Smart Sensor, or any standard room temperature sensor.

Features (continued) 03 Outputs The i2920 contains 16 outputs - eight Form C relay outputs, each rated for 24 VAC/VDC, 3 amp, and eight analog outputs (0-10V, 4-20mA). Both the relay and analog outputs have manual override switches, with software feedback of the switch position. Dimensional Drawings I/O Expansion The i2920 contains an I/O expansion port for the addition of up to two xp Expansion Modules directly on the bottom of the controller. The xp family of modules includes the DI-8, DO-2, DO-4, UI-4, AO-2, and AO-4. In addition, the I/O bus supports the xp Local Display Module, which allows the user to view and change point values. The Local Display Module is also available factory-mounted directly onto the i2920. Software Capabilities The dynamic memory of the i2920 can be allocated for any combination of programs, scheduling, alarming, and data logging using the powerful Andover Plain English TM programming language. Our object-oriented Plain English language with intuitive keywords provides an easy method to tailor the controller to meet your exact requirements. Programs are entered into the i2920 using the Andover Continuum CyberStation TM. Programs are then stored and executed by the i2920 controllers. Programming multiple i2920 controllers is inherently easy with Plain English. A complete copy of one i2920 s programs can be loaded directly into other i2920s without changing any point names or programs. Smart Sensor Interface The i2920 provides a built-in connection for Andover

Features (continued) 04 Smart Sensor Interface The i2920 provides a built-in connection for Andover Continuum Smart Sensor. The Smart Sensor provides a 2-character LED display and a 6-button programmable keypad that enables operators and occupants to change setpoints, balance VAV boxes, monitor occupancy status, and turn equipment on and off. An enhanced version of the Smart Sensor is also available with a 4-digit custom LCD that provides the following icons: PM, %,, Setpoint, Cool, Heat, CFM, Fan, OA, and SP.a Dimensional Drawings 1 Power Drawing 2 Communications Drawing 3 Inputs/Smart Sensor 4 Drawing Outputs Drawing

Specifications 05 i2920 System Controller Electrical Power 115/230 VAC, +10% -15%, 50/60 Hz Power Consumption 45 VA Overload Protection Fused with 3 amp fuse. MOV protected Real-Time Clock Battery-backed real-time clock Mechanical Operating Environment 32 120 F (0 49 C), 10 95% RH (non-condensing) Size 13.00 H x 10.66 W x 2.72 D (330.2H x 270.8 W x 69.0 D) mm Weight 3.5 lbs. (1.58 kg) Enclosure Type UL Open class, IP 10. Flammability rating of UL94-5V Mounting Panel mount Battery backup Replaceable, non-rechargeable, lithium battery. Provides 5 years typical accumulated power failure backup of RAM memory Communications Communications Interface Through Andover Continuum Infinet RS-485 field bus to network controller Communications Speed 1200 to 19.2K baud Bus Length 4,000 ft. (1,220m) standard for Andover Continuum Infinet, I2 Infilink module allows extension to longer distances and is required after every group of 32 units on the network Bus Media Andover Continuum Infinet: twisted, shielded pair, low capacitance cable Comm. Error Checking International Standard CRC 16 Compatibility Andover Continuum Cyberstation and Infinity SX 8000 systems Inputs/Outputs Inputs 16 Universal inputs: Voltage (0-10 VDC); Temperature -30 F to 230 F (-34 C to 110 C), Digital (on/off), Counter (up to 4Hz at 50% duty cycle, 125 ms min. pulse width). Supervised Alarm (single or double resistor). Current input (0-20 ma) using external 500 ohm resistor 1 Smart Sensor Temperature Input (32 F to 105 F) (0 C to 41 C) Input Voltage Range 0-10 volts DC Input Impedance 30.1K ohm to 10V or 5M ohm with pull-up resistor disabled Input Protection 24 VAC or 24 VDC temporarily on any single channel, ±1000V transients (Tested according to EN61000-4-4) Input Resolution 2.5 mv Input Accuracy ±7.5mV (±0.25 C from -23 C to +54 C) or (±0.46 F from -10 F to +130 F)

Specifications (continued) 06 i2920 System Controller Digital Outputs 8 single pole single throw (SPST) Form C relays (Any two consecutive Form C outputs can be configured as one Form K Tri-state) Output Rating Maximum 3A, 24VAC/VDC, ±1500V transients (Tested according to EN61000-4-4) Output Accuracy 0.1 sec. for pulse width modulation Analog Outputs 8 analog outputs Output Rating 0-10V or 0-20mA For 0-10V: 5mA maximum source, 1mA maximum sink 2K ohm minimum impedance (sourcing only), For 0 20mA: 750 ohm maximum +/-1000V transients (Tested according to EN61000-4-4). Fuse-protected. Output Resolution 0.1V for 0-10V, 0.1mA for 0-20mA Output Overrides Each output is equipped with a manual override switch. Software feedback of the switch position is provided, for display and alarming Expansion Bus Interfaces to optional xp I/O Expansion Modules Connections Power 3-position fixed screw terminal connector Inputs Outputs Smart Sensor Communications Expansion Port 6-position shrouded connector Service Port 4-position shrouded connector User LEDs/Switches Status Indicator LEDs CPU CPU Active TD Transmit Data RD Receive Data Output Output Status (per output) EXPANSION PORT PWR Power Status OVERRIDE Override Status Switches RESET Input Pull-up Resistor Switch (per input) Individual Output Override Switches General Memory 1MB SRAM, 2MB FLASH Processor Motorola 32-bit Coldfire Agency Listings UL/CUL 916, FCC CFR 47 Part 15, ICES-003, EN55022, AS/NZS 3548, Class A, CE Options UL864, Smoke Control System Equipment, UUKL (i2920-s) i2920-d, i2920 with factory mounted display All brand names, trademarks and registered trademarks are the property of their respective owners. Information contained within this document is subject to change without notice. 2006-2011 Schneider Electric. All rights reserved. November 2011