Rack Selection Guide for NetShelter SX

Similar documents
APC Open Frame Rack Networking Solutions

NetShelter SX Cable Management. Organize large volumes of cables from networking switches and patch panels

APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications

Solutions Guide for Cisco UCS B and C Series Servers

How to Sell APC s Cisco Approved Solution for Nexus 7018

Cabinet Solutions

RE Series Rack from Eaton Product Presentation

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center

Hassle-free equipment installation

Hassle-free equipment installation

Custom Rack Systems. Assembled & Configured-to-Order or Completely Customized Rack Systems & Rack Power Distribution

Enclosure and rack systems

EIA 310-D. RAL 9005 black textured, low-gloss polyester powder paint over pretreated steel.

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

APC APPLICATION NOTE #74

RACK SOLUTIONS. Rack Enclosures, Wall Mount Racks, Open Frame Racks and Accessories

or

UltraRack. Advanced Data Centre Enclosures SR SERIES

Thermal management. Thermal management

Enclosure and rack systems

EF-Series EuroFrame Gen 2 Cabinet System

DATACOM CABINETS SOLUTION GUIDE

Data center solutions for successful companies. cable management solutions

Rack 111 Catalog. Designed and Built to Exceed Your Needs.

Power and Cooling for Ultra-High Density Racks and Blade Servers

V800 Cabinet Solution

V-Built Custom Preconfigured Solutions

Cable Routing Procedures for Dell PowerEdge T320 & T420 Systems

Vertiv VR Rack 1.0 GENERAL

Great Lakes Product Solutions for Cisco Catalyst and Catalyst Switches: ESSAB14D Baffle for Cisco Catalyst 9513 Switch

APC APPLICATION NOTE #146

SYSTIMAX Rack and Cabinet Solution

QuickSpecs. Compaq Rack Accessories

QuickSpecs. HP Rack G2 Series. Overview

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

NetShelter CX Performance Guide

VERTIV VR RACK. Selection Guide

Rittal Cooling Solutions A. Tropp

QuickSpecs. HP Rack G2 Series Overview

Featured Products - RU Marking Standard on Hoffman brand

VersaPOD and V600. Cabinets. Section Contents. VersaPOD AND V600 CABINETS

HPE Performance Optimized Datacenter (POD) Networking Guide

Saving Critical Space. Cable Management Solutions

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

QuickSpecs. HPE G2 Enterprise Series Racks. Overview

Rack Systems. Rack enclosures and open frame racks for server and networking applications in IT environments

Datasheet. Fiber Optic Modular Patch Panel Features

QuickSpecs. HPE G2 Advanced Series Racks. Overview

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

Enhanced Data Centre Infrastructure

Space Saving Cable Management Rack Systems

Rack Solutions RS-2. Free Standing Racks & Cabinets Wall Mount Racks, Cabinets, & Brackets Shelving Cable Management Accessories RS-5 RS-10 RS-12

S-SERIES 2 Superior Rack Solution for Data Center & Network Closets

15U Wall-Mount Server Rack Cabinet - 20 in. Deep - Hinged

Compaq Ultra-Dense Server Deployment in Telecommunications (Telco) Racks

707 Patching Frames. 505 Frames. 303 Frames. 404 & 202 Wallboxes. 505 Cabinets. 303 Cabinets. Cold Aisle Containment. 505 Server Cabinets

Cable Routing Procedures for Dell PowerEdge T710 Systems

MECHANICAL AND THERMAL CONSIDERATIONS FOR RACK DEPLOYMENT OF THE DELL POWEREDGE M-SERIES. One Dell Way Round Rock, Texas

SMARTPLAY7. Increase your Deal Size and Profitability with SmartPlays

Charles Nolan. Do more with less with your data centre A customer s perspective. Director IT Infrastructure, UNSW. Brought to you by:

INTEGRATED SOLUTIONS. Tripp Lite Integrated Solutions. FREE Solution Integration Service

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA

Improve the appearance and accessibility of your rack

Rack Installation Instructions

NetShelter CX Technical Guide

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures

4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions

QuickSpecs. HPE G2 Enterprise Series Racks. Overview

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

InstaPATCH Cu Cabling Solutions for Data Centers

RCM & RCM+ enhancement

RACKS AND CABLE MANAGEMENT

APPLYING PROPER CABLE MANAGEMENT IN IT RACKS. A Guide For Planning, Deployment And Growth

IBM BladeCenter S Competitive Summary

COOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments

Nov.08. Chinaracks Shanghai Technical Communication Company PRODUCT SPEC: Wide body Server Cabinet - Server Rack - Cabnet 42U

Centeris Data Center

QuickSpecs. HPE G2 Advanced Series Racks. HPE G2 Advanced Series Racks. Overview

BUILDING NETWORK SOLUTIONS GUIDE

Rack Installation Instructions

Close Coupled Cooling for Datacentres

Top. Bottom W W W. S I E M O N. C O M

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

SPECTRUM-2 CONSOLES. TEL: WEB: winsted.com

HYPERFRAME CABINET & ENCLOSURE SOLUTIONS

paramount enclosure system

Site Preparation for ClearCube Installation. Rev. F

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

FVT Slot Media Converter Chassis w/ Redundant Power User Manual

PI Server - 19 enclosures

Cisco Nexus 7000 Series.

Certified 1. AMCO Enclosures Containment Brochure. Hot/Cold Aisle Containment Solutions ACB3.0. Designed and Manufactured in the USA

QuickSpecs. HP Rack G2 Series - top view

Selection Guide. IT & Data Center. Rack & Enclosure Systems

Installation and Maintenance

Cisco Nexus 7000 Series

CABINETS & CONTAINMENT SOLUTIONS GUIDE. designed to be better

Titan Cable Management Catalog TCM3.0. IMS Engineered Products is ISO 9001 Certified. Designed and Manufactured in the USA

Transcription:

Rack Selection Guide for NetShelter SX Choosing the right rack based on application and equipment type Click here to download the new White Paper #201: How to Choose an IT Rack

Rack Selection Guide for NetShelter SX 1U servers Deeper for cabling -More space for data and power cable management 42-84 power cords 42-168 data cables 1900-2200lbs loaded (860 1000kg) 9-16kW per rack Extra positions for additional Rack PDUs -Install up to 4 vertical Rack PDUs Common Servers Cisco UCS C200, Dell PowerEdge R310, R620 HP ProLiant DL320e, DL160 IBM System x 3550 AR3300 Deep Rack AR3300G Now available in grey! Cabling space for 1U servers More servers means more outlets and more data cables that need to be managed. Deep racks like the AR3300 allow space for additional rpdus and plenty of Cat-5 or Cat-6 data cabling. o Width: 23.6 (600mm) o Depth: 47.25 (1200mm) o Height: 42U - 78.4 (1991mm) o Weight Cap.: 3000lbs (1360kg) Rack

Cable Management Selection Guide for NetShelter SX 1U servers Low profile -Maximum clearance for equipment access 42-84 power cords 42-168 data cables Mixed copper and fiber data 9-16kW per rack Common Servers Cisco UCS C200, Dell PowerEdge R310, R620 HP ProLiant DL320e, DL160 IBM System x 3550 Cable capacity for 1U servers More servers means more outlets and more data cables that need to be managed. Low profile cable managers like the AR7721 offer cable guides at every rack U space without interfering with the 19 equipment mounting space. Cable management at every rack U space -Provide secure routing exactly where needed AR7721 Vertical Cable Manager o Rack U Span: 42U o No Equipment Clearance Impact o Compatible Racks: AR3100, AR3300 o Cable Capacity: 49 Cat6a, 251 fiber Cabling

Rack Selection Guide for NetShelter SX 2U 4U Servers 21-42 power cords 21-84 data cables 750-1200 lbs loaded (340-544kg) 4-10kW per rack Mount Rack PDUs Toollessly -Dedicated vertical Rack PDUs mounting area Pre-installed accessory channel -Easy accessory integration Common Servers Cisco UCS C23, C240 Dell PowerEdge 2950, R720, R900 HP ProLiant DL380, DL560, DL580 IBM System x 3755, 3650, 3550 AR3100 Standard Rack AR3100G Now available in grey! Right sized for 2U-4U servers Taller servers have fewer data and power cords, so less space is needed for cable management. The AR3100 maximizes use of data center floor space and still accommodates a rack full of 2U-4U 19 servers, data and power cables. o Width: 23.6 (600mm) o Depth: 42.1 (1070mm) o Height: 42U - 78.4 (1991mm) o Weight Cap.: 3000lbs (1360kg) Rack

Cable Management Selection Guide for NetShelter SX 2U 4U Servers 21-42 power cords 21-84 data cables Copper connections 4-10kW per rack Common Servers Cisco UCS C23, C240 Dell PowerEdge 2950, R720, R900 HP ProLiant DL380, DL560, DL580 IBM System x 3755, 3650, 3550 Sturdy cable protection -Steel rings provide stiffness to prevent accidents Organizes and protects cables Cable rings allow easy installation for both power and data cabling, and provide quick access and traceability during equipment refresh cycles. Its low profile helps ensure that equipment is visible and accessible. Up to 55 Cat6a data cables can be managed and protected with the AR8442. Toolless mounting -Fits in Zero U accessory channel for easy install Organize power or data -Rings allow any type of cable to be installed or removed quickly AR8442 Ring Cable Organizer o Rack U Span: 21U o Compatible Racks: All o Cable Capacity: 30 Cat6a Cabling

Rack Selection Guide for NetShelter SX Blade Servers Dedicated cabling area -Keep the cabling organized 16-32 power cords 24-48 data cables 1500-2000 lbs loaded (680-900kg) 17-30kW per rack Common Chassis Cisco UCS 5100 series Dell PowerEdge M1000e HP BLc3000, BLc7000 IBM BladeCenter series Clearance for blade servers It is very difficult to route power and data cables and still have clearance to remove all the hot-swappable components from a blade chassis. Wide racks like the AR3150 provide space on either side of the chassis for full hot-swap component access. Full equipment access -Unobstructed hot-swap component access AR3150 Wide Rack o Width: 29.5 (750mm) o Depth: 42.1 (1070mm) o Height: 42U - 78.4 (1991mm) o Weight Cap.: 3000lbs (1360kg) AR3180G Now available in grey 800m W! Rack

Cable Management Selection Guide for NetShelter SX Blade Servers 16-32 power cords 24-48 data cables Multiple fiber connection Rear cable management 6 cable guides -Allow more cabling per U space -Bend radius protects fiber Hinged covers -Conceal vertical cable routing Common Chassis Cisco UCS 5100 series Dell PowerEdge M1000e HP BLc3000, BLc7000 IBM BladeCenter series Organizes and protects cables Up to 1271 fiber or 190 Cat6a data cables can be managed with the AR7580A, and cables can be secured in 1U increments. This low profile cable manager secures all cabling outside the 19 rack-mounting space and maximizes access for hot-swappable components in blade chassis. AR7580A & AR7581A Vertical Cable Manager and Covers About this cable manager o Rack U Span: 42U o No Equipment Clearance Impact o Compatible Racks: AR3150, AR3350 o Cable Capacity: 1271 fiber, 190 Cat6a Cabling

Rack Selection Guide for NetShelter SX Network Switches 2-4 switches 4-12 power cords 400-800 data cables 600-900 lbs loaded (270-400kg) 6-10kW per rack Pre-configured for maximum cabling -Dedicated channel & cable manager at every U-space Accommodates side-to-side cooling -Vented rails guide airflow where needed Common Switches Cisco Catalyst 6509*, MDS 9513* Juniper EX6200, EX8200, EX9200 *These models require sar7715 duct kit due to side-to side air flow AR3140 Networking Rack AR3140G Now available in grey! Preconfigured for networking Since switches typically mean lots of data cable, the AR3140 has space on either side and pre-installed cable managers specifically for routing cable. Additionally, the rails are recessed to allow cable clearance at the front of the rack and designed for equipment with side-to-side airflow. o Width: 29.5 (750mm) o Depth: 42.1 (1070mm) o Height: 42U - 78.4 (1991mm) o Weight Cap.: 3000lbs (1360kg) Rack

Cable Management Selection Guide for NetShelter SX Network Switches 2-4 switches 4-12 power cords 400-800 data cables Multiple fiber and copper connections Front vertical cable management pre-installed Rear pass-through -Brush strips allow cable access to rear of rack while preventing air recirculation Hinged cover -Organize and protect cables while still providing access Common Switches Cisco Catalyst 6509, MDS 9513 Juniper EX6200, EX8200, EX9200 Manage high density cabling Since switches typically mean lots of data cable, the AR8603A helps to distribute cable loads to both sides of the rack as well as from front to rear while keeping a clean and organized layout within the rack. o Rack U Span: 2U AR8603A High Density Horizontal Cable Manager o No Equipment Clearance Impact o Compatible Racks: All o Cable Capacity: 916 fiber, 137 Cat6a Cabling

Rack Selection Guide for NetShelter SX Deep Network Switches 6-10 power cords 600-1200 data cables 800-1400 lbs loaded (360-635kg) 15-25kW per rack Accommodates side-toside cooling -Vented rails guide airflow where needed Deepest switch clearance -Plenty of space for switch & cabling Pre-configured for maximum cabling -Dedicated channel & cable manager at every U-space Common Switches Cisco Nexus 7010, 7018* Huawei CloudEngine 12800 * This model requires AR7742 duct kit due to side to side air flow AR3340 Deep Networking Rack AR3340G Now available in grey! Preconfigured for networking Deeper racks are required to house the deepest switches and the accompanying cabling. Since switches typically mean lots of data cable, the AR3340 has space on either side and pre-installed cable managers specifically for routing cable. o Width: 29.5 (750mm) o Depth: 47.25 (1200mm) o Height: 42U - 78.4 (1991mm) o Weight Cap.: 3000lbs (1360kg) Rack

Cable Management Selection Guide for NetShelter SX Deep Network Switches 6-10 power cords 600-1200 data cables Multiple fiber connections 15-25kW per rack Common Switches Cisco Nexus 7010, 7018 Huawei CloudEngine 12800 Manage high density cabling Since switches typically mean lots of data cable, the AR8605 helps to distribute cable loads to both sides of the rack as well as from front to rear while keeping a clean and organized layout within the rack. o Rack U Span: 3U Rear pass-through -Brushes allow rear access and prevent air recirculation Hinged cover -Hide, organize and protect data cabling AR8605 High Density Horizontal Cable Manager o No Equipment Clearance Impact o Compatible Racks: All o Cable Capacity: 1259 fiber, 189 Cat6a Cabling

Rack Selection Guide for NetShelter SX Network Storage 21-42 power cords 21-84 fiber cables 800-1400 lbs loaded (360-635kg) 4-8kW per rack Mount rack PDUs toollessly -Dedicated vertical rack PDUs mounting area Conserve floor space -Standard rack width & depth for smallest footprint Common Storage EMC VNX series Oracle Sun Storage 2500 Seagate STDN series AR3100 Standard Rack AR3100G Now available in grey! The right size for network storage Typical storage devices don t require much space for cable density and can be supported by one set of Rack PDUs. The AR3100 is the perfect rack to house this equipment comfortably without wasting space. o Width: 23.6 (600mm) o Depth: 42.1 (1070mm) o Height: 42U - 78.4 (1991mm) o Weight Cap.: 3000lbs (1360kg) Rack

Cable Management Selection Guide for NetShelter SX Network Storage 21-42 power cords 21-84 fiber cables Multiple fiber connections 4-8kW per rack Promote proper bend radius for fiber -Mitigate cable kinking Eliminate fiber slack -Move fiber spools to any position to dress fiber runs Common Storage EMC VNX series Oracle Sun Storage 2500 Seagate STDN series Protection for fiber cabling Typical storage devices don t require much space for cable density but they usually need special consideration for the delicate fiber transferring data. The AR8443A and AR8654 organize fiber and protect it from kinks and other damage. AR8443A Fiber Organizer AR8654 & Cable Fall o Rack U Span: 42U o Compatible Racks: All o Cable Capacity: 288 fiber Cabling

Rack Selection Guide for NetShelter SX Converged IT Infrastructure Multiple equipment types -Flexible rack for multiple equipment types in one rack 21-42 power cords 21-84 data cables 1000-1500 lbs loaded (450-680kg) 6-8kW per rack Easy cable routing and full equipment access -Dedicated side space for 1) front to back cable routing 2) unobstructed access to server hot swap components Common Infrastructure 6U -10U switch Up to 20 servers 1-2 blade chassis Network storage Server Access for converged IT Mixing servers, switches and storage demands a flexible rack space for front-to-rear cable routing and hotswap component clearance. The AR3150 provides generous space for data and power distribution while still providing full front and rear equipment access. Network AR3150 Wide Rack Storage o Width: 29.5 (750mm) o Depth: 42.1 (1070mm) o Height: 42U - 78.4 (1991mm) o Weight Cap.: 3000lbs (1360kg) AR3180G Now available in grey 800m W! Rack

Cable Management Selection Guide for NetShelter SX Converged IT Infrastructure 21-42 power cords 21-84 data cables Mixed copper and fiber 6-8kW per rack Front to back access -Brush strips allow for convenient routing from switches to servers Hinged covers -Conceal vertical cable routing Common Infrastructure 6U -10U switch Up to 20 servers 1-2 blade chassis Network storage Converged IT cable management Mixing servers and switches demands flexibility for front-to-rear cable routing. The AR8429 provides this access and is covered by brush strips to prevent air mixing. The AR7580A secures cabling outside the 19 aisle full access for hot-swappable components in blade chassis. AR8429 Horizontal Organizer o Rack U Span: 42U AR7580A & AR7581A Vertical Cable Manager & Covers o No Equipment Clearance Impact o Compatible Racks: AR3150, AR3350 o Cable Capacity: 1271 fiber, 190 Cat6a Cabling

Rack Selection Guide for NetShelter SX 23 Telecommunications 24-64 power cords 40-200 data cables 700-1000 lbs loaded (310-450kg) 2-6kW per rack Right fit for telecom -Rail kit provides 23 EIA equipment mounting Dedicated cabling area -Keep the cabling organized Common Applications Power distribution Distributed antenna systems (DAS) Network transmission AR3150 Wide Rack & AR3180G Now available in grey 800m W! AR7510 23 Rail Kit Room for telecom mounting The 23 mounting width common with equipment for telecommunications requires a wide rack. The AR3150 provides generous space on both sides for data and power distribution while still providing full front and rear access to equipment. o Width: 29.5 (750mm) o Depth: 42.1 (1070mm) o Height: 42U - 78.4 (1991mm) o Weight Cap.: 3000lbs (1360kg) Rack

Cable Management Selection Guide for NetShelter SX 23 Telecommunications 24-64 power cords 40-200 data cables Mixed copper and fiber data 2-6kW per rack Low profile -Maximum clearance for equipment access Cable management at every rack U space -Provide secure routing exactly where needed Common Applications Power distribution Distributed antenna systems (DAS) Network transmission Room for telecom mounting Secure and protect both copper and fiber data cabling at every U space. The AR7721 promotes the proper bend radius for fiber and prevents cabling from obstructing access to equipment installed in the rack. AR7721 Vertical Cable Manager o Rack U Span: 42U o No Equipment Clearance Impact o Compatible Racks: AR3150, AR3350 o Cable Capacity: 38 Cat6a, 251 fiber Cabling