INNOVATIVE LASER POSITIONING SOLUTIONS IN RADIATION ONCOLOGY.

Similar documents
Add a Healthy Dose of Innovation to Your Linac and CT Rooms

A NEW LASER FOCUS ON PATIENT SAFETY

LASER SOLUTIONS. Ensure Accurate Setup from Simulation to Treatment. MOVEABLE: CT SIM+ // FIXED: MICRO and MICRO+

THE WIRELESS PHANTOM PERFORM ACCURATE PATIENT QA IN LESS TIME THAN EVER!

Centralite CT Moving Laser Patient Positioning System (MRR-1)

Initial Clinical Experience with 3D Surface Image Guidance

Aligning Parallelism of Rolls Has Never Been Faster. L-732 Precision Dual-Scan Roll Alignment System

A Global Laser Brand. Versatile Module

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC

INSTRUCTIONS RPD INFORMATION RPD PRODUCT INFORMATION. Address 5218 Barthel Industrial Drive Albertville, MN Website

Cemar Electro Inc. MAXX-1100Laser Positioning System. Installation and Set-up Manual

Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon

Cemar Electro Inc. MAXX-1100 Laser Positioning System. Installation and Set-up Manual

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE

ph fax Deming Way Middleton WI USA

Optical Guidance. Sanford L. Meeks. July 22, 2010

Thank-You Members of TG147 TG 147: QA for nonradiographic

Laser Systems for Patient Alignment

xorantech.com Suite of DR Products

T-SCAN 3 3D DIGITIZING

Thread Mountable Cameo Laser Diode Module

Beams You Up to a New Era in 3D Water Scanning.

Digital phantoms for the evaluation of a software used for an automatic analysis of the Winston-Lutz test in image guided radiation therapy

Single-Axis Lasers for Flatness and Leveling Applications. Laser Systems for Flatness and Leveling L-730/L-740 Series

LaserLyte-Flex Red & Green Alignment System

DAILY LINAC QA BEAM QA

URGENT IMPORTANT FIELD SAFETY NOTIFICATION

Specifications PHAENON X Mini / Pro Laser Projectors

EI- Shaft Alignment System

XL-80 spares list. Application note. Overview

ЗАО «БЕРГ АБ», (495) , Intrinsically safe shaft alignment tool with printer

Greenline-Laser 3P / 5P

FOX DIODE LASER. Power Calibration at Fiber Distal Tip Green Aiming Beam Video Touch Screen Intuitive Handling Rapid Amortization

CARINAnav SMART LASER CONTROL

Laserlyte-Flex Alignment System

ITEMS FOR SALE 29/04/17

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

LASER SLIT LAMP. Optimized for Retina

Cross Line Laser kit. User Manual for EK-226P

Operating Instructions TPL 50 HV

MapCHECK 2 & 3DVH. The Gold Standard for 2D Arrays

Mediso AnyScan S Single-Head and Dual-Head SPECT

MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays

810 nm. 980 nm FOX nm 12 W VERSATILE FOX 810/980/ 1064/1470 nm IDEAL FOR: DENTAL ENT DERMATOLOGY GYNECOLOGY SURGERY / VET.

A Global Laser Brand. Gated Cameo

Laserlyte Alignment System

Up to 50% of all costs related to rotating machinery breakdowns is caused by shaft misalignment

NEW! Smart Camera Series LSIS 400i Fast and simple quality assurance and identification through innovative and high-performance camera technology

High-End System Accuracy at Entry-Level Pricing Windows Rugged Industrial Tablets 8 & 10 Touchscreen Displays Innovative Dual-Fan Technology Any

High-End System Accuracy at Entry-Level Pricing Windows Rugged Industrial Tablets 8 & 10 Touchscreen Displays Innovative Dual-Fan Technology Any

Lucy Phantom MR Grid Evaluation

Fast, Easy and Highly Accurate Extruder Alignment. L-705 Laser Borescope Alignment System for Extruders

0,25 mm false pulse suppression 4 program options 4 program options on/off switchable 4 preset levels or level set by customer.

ZRapid Technologies Co. Ltd

Delta 4 PT. True Volumetric Pre-treatment Verification. The difference is clear

PET-CT in Radiation Treatment Planning

FLEXPOINT DOE Series Laser Modules with Diffractive Optical Elements

SpectraTec X. Multi- λ Laser Light Source BLUE SKY RESEARCH WAVELENGTHS

Z-MOTION. Universal Digital Radiographic System Z-MOTION. Control-X Medical CONTROL-X MEDICAL

New generation of LASER modules latest developments and how you can benefit from them. Stephan Broche

StingRay and BioRay FEATURES

A point of reference Opton 8000 The most complete range of scanning lasers High performance technology Advanced scanning modes

Raising the Bar in IMRT QA

MPI TS150-THZ 150 mm Manual Probe System

Mediso AnyScan. Single-Head and Dual-Head SPECT

S. Guru Prasad, Ph.D., DABR

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Patented

BMFL Wash / Wash XF. Light source. Osram Lok-it! HTI 1700/PS. Tel: Fax:

BMFL Wash / Wash XF. Light source Osram Lok-it! HTI 1700/PS. LIGHT OUTPUT lm at W. Zoom range

Laserlyte-Flex Userguide

Leica M844 C40 CT40. Leica ceiling solutions for Ophthalmology. Living up to Life

How Computer Mice Work

CHAPTER 2: THREE DIMENSIONAL TOPOGRAPHICAL MAPPING SYSTEM. Target Object

Laserglow Product Datasheet

MPI TS150-AIT 150 mm Manual Probe System

1. Safety instructions

EXPLORER CLASSIC BRIDGE COORDINATE MEASURING MACHINE PRODUCT BROCHURE

StingRay Accessories Datasheet

RgBLase LLC P/N: FB 671 XXX Diode Pumped Solid State Laser Module

PPM-350C PON Power Meter

2H 5654 B20 S 2 40 A. How to read part numbers. Motor Technology. Motor dimension. Current per phase. Encoder family. Encoding accuracy.

Mirror positioning on your fingertip. Embedded controller means tiny size plus fast, easy integration. Low power for hand-held systems

FLEXPOINT Laser Modules. Laser Modules For Your Application. laser-components.com

Coherent Magnum II. Structured Light Pattern Generating Laser FEATURES

Laser Power Probes POWER PROBES OEM SOLUTIONS USB/RS232 SENSORS MONITORS & SW

3D Scanning Comes Full Circle

COMPACT PRECISION LINEAR MOTORIZED ACTUATORS LSMA Series LSMA-173

Design approach for a Highly Accurate Patient Positioning System for NPTC

Thermo Scientific DXR2 Raman Family

Automated High Accuracy Non-contact Profile Diameter Scanner (0.0001" Repeatability)

Stealth SerieS. Shaft alignment SyStemS S-660CRT & S-660T WIRELESS 3-AXIS

405 nm Diode Lasers. 14-pin BF, D-type OEM Module & Turn-key Systems. 405 nm Single-Mode Wavelength Stabilized Diode Lasers

ParCon and PosCon line sensors

CUBE. Diode Laser System. Superior Reliability & Performance

Evaluation of AutoQA Lite TM Image Quality Measurement Software

HL6319G/20G. 638nm / 10mW AlGaInP Laser Diode

PRESETTER SP40. Pesaro, September 2013

NL-01 NL-01. The NL-01 InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement.

Safetinex Safety light curtains and access control barriers

Transcription:

INNOVATIVE LASER POSITIONING SOLUTIONS IN RADIATION ONCOLOGY www.cyrpa.com

TREATMENT ROOM HITM : FIXED MOTORISED LASERS Adapted to each radiation treatment room, the HITM positioning system differentiates itself by using lasers that allow treatment of the patient with greater accuracy (0,1mm). Additionally, it performs a fast and automatic adjustment of the lasers. The HITM consists of 3 fixed motorised laser boxes : 2 lateral lasers, each generating a cross 1 sagittal laser, generating a line It is possible to add other laser lines, also in red or green Each laser can be red or green, switchable at any time. The system also includes a tablet PC that allows each laser beam to be controlled remotely through a wireless network. DOUBLE DIODE adaptability colors : red + green there is always a diode in back up MOTORISED LASER BOX Dimensions (HxWxD) : 220mm x 205mm x 110mm Weight : 4kg Power Supply : Internal 110/230 VAC Consumption of less than 500mA Temperature : 15-30 C Type of control : Motorised Remote control via a wireless network interface and a tablet PC Accuracy of adjustments at isocenter : +/- 0,1mm stable high precision solution +/- 0,1mm proton treatments stereotactic treatments linac treatments

automatic calibration with smartphantom CYRPA is the only supplier worldwide to offer a complete automatic calibration pointing to the exact isocenter with the SmartPhantom. The SmartPhantom is a device patented by CYRPA to allow the automatic calibration either in the treatment room (SmartPhantom RT), or in the virtual simulation room (SmartPhantom CT). real automatic calibration: click & go COMPLETE CYCLE OF LASER CALIBRATION 0.1 mm in less than 10 minutes The optical sensors detect the position of the lasers Lasers move to the requested position Wireless connection with CyrpaSoft CyrpaSoft sends the correct position Manual adjustment not necessary SMARTPHANTOM RT Material: aluminum structure with adjustable feet with 15 high precision optical sensors 3 adjustable micrometric feet Dimensions (mm): 380 x 300 x 300 Weight (kg): 6.3 Wireless connection with RF Plexiglas markers Internal positioning lasers SMARTPHANTOM CT Material: aluminum structure with 12 high precision optical sensors 3 adjustable micrometric feet Dimensions (mm): 520 x 300 x 300 Weight (kg): 5.2 Wireless connection with RF Plexiglas markers

simulation room Moving Lasers High Impact Technology: HIT 1 - HIT 3 - HIT 5 - HIT 6 The CYRPA HIT lasers systems present the latest innovation in virtual simulation. With different configurations possible, the HIT virtual simulation lasers have been designed with the user and patient in mind. With the touch of a button, the user can select a green or red diode laser line, each with a laser line accuracy of +/- 0.1mm allowing a faster and more accurate operation. Configurations: HIT1 HIT3 HIT5 HIT6 MOVING LASER BOXES 1 3 5 6 MOTORISED LASER BOXES 2 2 no couch movement MOVING LASER BOX Dimensions (HxWxD) : 920mm x105mm x 90mm Weight : 5kg Power Supply : Internal 110/230 VAC Consumption of less than 500mA Temperature : 15-30 C Type of control : Motorised Remote control via a wireless network interface and a touchscreen Accuracy of adjustments at isocenter : +/- 0,1mm Length of travel : 540mm double diode AUTOMATIC CALIBRATION Accuracy +/- 0,1mm

MRI ROOM HIT SINGLE DIODE LASERS FIXED WITH MANUAL ADJUSTMENT The HIT Single Diode includes only one diode per optical head, and it can be either red or green. The adjustment of laser lines on all three movements (rotation, translation and tilt) is possible without opening the laser cover. This allows a better stability of the adjustments. Indeed, when putting back the cover after the adjustment is done inflicts a constraint to the lasers and unsettles them. With the CYRPA HITSD, only a simple wrench is necessary to adjust the laser, from the outside, without removing the laser cover. SIMPLE AND STABLE ADJUSTMENT WITHOUT REMOVING THE COVER FOR ALL 3 MOVEMENTS The HITSD fixed manual lasers are compatible in any kind of room, but those for MRI are supplied with compatible supports. MANUAL FIXED LASERS CERTIFIED FOR AN MRI ENVIRONEMENT UP TO 3T HITSD: MANUAL LASER BOX A SIMPLE AND STABLE SOLUTION FOR YOUR MRI ROOM MANUAL BOX Dimensions (HxWxD) : 220mm x 205mm x 110mm Weight : 2kg Power supply : Internal 11/230 VAC Consumption of less than 500mA Temperature : 15-30 C Type of control: manual Adjustable without removing the cover

STATICPHANTOM the universal tool for laser alignment control Once the StaticPhantom is set-up on the CT couch it is used to visually verify the precision of the alignment of lasers. Marks on the device allow you to check the movement of the lasers no matter the brand of the lasers. The precision of the position of the marks is 0,1 mm. CyrpaSoft includes a patient file to operate the automatic control of the positions with the StaticPhantom. This patient file is supplied with the StaticPhantom to be used with your system. advantages Multiple recessed alignment marks to perform calibration of frontal, transversal and sagittal lasers Can be used to align moving lasers, from CYRPA or other laser brands Includes alignment holes and three adjustable micrometric feet for leveling the unit on a couch The size of the StaticPhantom allows a more precise verification of the straightness of lines over a bigger volume. C daily qa of the alignment and movement of the lasers with an easy and fast set up STATICPHANTOM Material: acrylic Dimensions (mm): 320x300x300 Weight (kg): 6 9 checkpoints low budget solution

CYRPASOFT TPS Connection DICOM TumorLOC CYRPASOFT is a software created by CYRPA to run the lasers. CYRPASOFT can handle the mains format files and can be configurated to import data from many different TPS systems. It easily allows to: Change colors with the option double diode Move lasers from a position X, Y, Z manually requested (HIT) or imported from a TPS (HIT) Reboot lasers hardware IT configuration can be customized Compatible with the different workflows: relative and absolute patient marking. In relative mode, the zero laser can be redefined on an already existing marking. cyrpasoft includes a module for the automatic calibration with the smartphantom and the movement test function with the staticphantom diodes technical specifications RED LASER Type : Diode Wavelength : 635nm Maximum output power : < 1mW Laser class : Class 2 Line width : < 1mm Line length : > 3m GREEN LASER Type : Diode Wavelength : 532nm Maximum output power : < 1mW Laser class : Class 2 Line width : < 1mm Line length : > 3m DIODE AVAILABLE IN BLUE UNDER REQUEST ALL DEVICES CARRY A ONE-YEAR DIRECT CYRPA WARRANTY. CYRPA products are Class 1 according to the European Directive 93/41 relative to medical devices.

INNOVATION your high precision laser solution ANY CONFIGURATION IS POSSIBLE: COMBINE FIXED, MOTORIZED AND MOVING LASERS AUTOMATIC CALIBRATION WITH SMARTPHANTOM Done in around 10 minutes Double Diode Red AND green for each laser line, switched in a second by the operator PATIENT SAFETY Quality certificate delivered at the end of the automatic calibration +/- 0,1 mm accuracy at the isocenter Precision at the patient positioning TIME SAVINGS Thanks to the automatic calibration CUSTOMIZED SOLUTIONS Adapted to the needs of each user DOUBLE-CHECKED ACCURACY With two encoders internal and external WORLDWIDE PRESENCE: CONTACT US TO KNOW YOUR LOCAL DISTRIBUTOR FRANCE CYRPA Innovations SARL Roissypôle Bât Aeronef BP13918 5 rue de Copenhague 95731 Roissy CDG Cedex Phone : +33 (0) 1 74 37 27 03 VAT : FR 71753668615 BELGIUM CYRPA International SPRL Rue de Stalle 140, 3éme étage Uccle 1180 Brussels Phone : +32 (0) 2 344 05 94 VAT : BE 0829158572 Email : info@cyrpa.com Cyrpa is owned by the group (www.c-rad.com)