Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Similar documents
Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

Siemens Industrial s

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Instruction manual. Output chokes 690V. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

SIMOTION. SIMOTION SCOUT SIMOTION SCOUT TIA device proxy. Preface. Fundamental safety instructions 1. Overview 2. Create and configure device proxy.

Readme SiVArc V14 SP1 Update 6

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

Medium-Voltage Drive SINAMICS SM150. Type 6SL3845. Tests carried out on drives This documentation pertains to SM150 wassergekühlt G20 F03 F72 F79 F76

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

Device manual SINAMICS SINAMICS G120. Distributed inverter box Control cabinet for wall or floor mounting.

Converter SINAMICS G150. Type 6SL37102G

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

ST (6ES7132-6FD00-0BB1)

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

Getting Started SIMOTION SCOUT - sample project SIMOTION D435-2 SIMOTION

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Siemens Drives & PLCs

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

Power Module PM230, IP20 / Push-through technology (PT) SINAMICS. SINAMICS G120P Power Module PM230, IP20 / Push-through technology (PT)

PD PA AP How To Configure Maxum II TimeServer Access

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

Digital output module. DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

SINAMICS G130. Cabinet design and EMC. Operating Instructions 03/2013 SINAMICS

Mechanical Installation Manual SINUMERIK. SINUMERIK 808D Mechanical Installation Manual. Preface. Safety instructions 1. Identification 2.

First Steps in Commissioning CPU. 31xC: Positioning with digital output SIMATIC

Optional package printer driver V1.4

SIMOTION. SIMOTION SCOUT Updating SIMOTION Devices. Preface. Fundamental safety instructions 1. Overview 2. Updating 3. Restoring 4.

Class: DocumentManager 1 COMOS. Platform Class documentation DocumentManager_dll. Programming Manual 03/2017 V10.2.

Getting Started SIMOTION SCOUT - sample project SIMOTION D435-2

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SITOP UPS1600 under STEP 7 V13. SITOP UPS1600 under STEP 7 V13. Introduction. Safety notes. Description. Assigning the IP address

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC. S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Preface

Class: POptions 1 COMOS. Platform Class documentation POptions_dll. Programming Manual 04/2014 A5E AA

SITOP UPS1600 under STEP 7 V5. SITOP UPS1600 under STEP 7 V5. Introduction. Safety notes. Description 3. Assigning the IP address

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

SINAMICS S120 Combi SINAMICS. S120 SINAMICS S120 Combi. Preface. Fundamental safety instructions 1. System overview 2. Line-side power components

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Speed monitor D / / 2014

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

Siemens Spares COMOS. Operations Inspection. Introduction 1. Working with the "Inspection" plugin 2. Working with the "Inspection diagram" plugin 3

party software COMOS Platform Third-party software Trademarks 1 Requirements for the system environment Third-party software releases Operating Manual

SINAMICS Siemens Controlss

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

COMOS. Operations Inspection. Introduction 1. Working with the "Inspection" plugin 2. Working with the "Inspection diagram" plugin 3

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3.

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

Manual Edition 03/2010

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

Getting Started SINAMICS. S120 Getting Started. Preface. Fundamental safety instructions. SINAMICS S120 drive system 2. Overview 3

MindSphere. MindConnect IoT Extension Getting Started. Introduction to MindSphere. Prerequisites 2. Preparations 3. MindConnect IoT Extension

Siemens Automation Products

MDM 011-Z1 Regen Resistor

Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1.

Deckblatt. APL Operator Guide SIMATIC PCS 7. Application description June Applikationen & Tools. Answers for industry.

PanelView Plus/VersaView CE Terminals and Display Modules

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation

SIMATIC. ET 200S distributed I/O 2AO U ST analog electronic module (6ES7135-4FB01-0AB0) Preface. Properties 1. Parameters 2.

RF-MANAGER simulator SIMATIC. RFID-Systems RF-MANAGER simulator. Simulating projects. Compact Operating Instructions 06/2010 A5E

Class:ELOLib 1 COMOS. Platform Class documentation ELOLib_dll. Programming Manual. Siemens Distributor 09/2014 A5E AA

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3

Key Panels Library SIMATIC HMI. Key Panels Library. Preface 1. Installation of Key Panels Library. Working with the Key Panels Library

English. SIMATIC Sensors. RFID-Systems RF600. Getting Started. Edition 11/2005; J31069-D0172-U001-A1-7618

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

High Precision Quad Output DC Power Supply

Transcription:

Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A

Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recoended or approved by Siemens. Proper transport, storage, installation, assembly, coissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY A5E00331462A P 08/2014 Subject to change Copyright Siemens AG 4-2014. All rights reserved

Table of contents 1 Safety information... 7 1.1 General safety instructions... 7 2 General... 11 3 Mechanical installation... 15 4 Electrical installation... 19 5 Technical specifications... 21 Operating Instructions, 04/2014, A5E00331462A 5

Table of contents 6 Operating Instructions, 04/2014, A5E00331462A

Safety information 1 1.1 General safety instructions DANGER Danger to life due to live parts and other energy sources Death or serious injury can result when live parts are touched. Only work on electrical equipment if you are appropriately qualified. Always observe the country-specific safety rules for all work. Generally, six steps apply when establishing safety: 1. Prepare for shutdown and notify all those who will be affected by the procedure. 2. Disconnect the machine from the supply. Switch off the machine. Wait until the discharge time specified on the warning labels has elapsed. Check that it really is in a zero-voltage state, from phase conductor to phase conductor and phase conductor to protective conductor. Check that every auxiliary circuit is de-energized. Ensure that the motors cannot move. 3. Identify all other dangerous energy sources, e.g. compressed air, hydraulic systems or water. 4. Isolate or neutralize all hazardous energy sources by closing switches, grounding or short-circuiting or closing valves, for example. 5. Take measures to prevent reconnection of the energy sources. 6. Ensure that the correct machine is completely interlocked. After you have completed the work, restore the operational readiness by following the above steps in the reverse order. WARNING Danger to life through a hazardous voltage when connecting an unsuitable power supply Death or serious injury can result when live parts are touched in the event of a fault. Only use power supplies that provide SELV (Safety Extra Low Voltage) or PELV (Protective Extra Low Voltage) output voltages for all connections and terminals of the electronics modules. Operating Instructions, 04/2014, A5E00331462A 7

Safety information 1.1 General safety instructions WARNING Danger to life when live parts are touched on damaged devices Improper handling of devices can cause damage. For damaged devices, hazardous voltages can be present at the enclosure or at exposed components; if touched, this can result in death or severe injury. Ensure compliance with the limit values specified in the technical data during transport, storage and operation. Do not use any damaged devices. WARNING Danger to life through electric shock due to unconnected cable shields Hazardous touch voltages can occur through capacitive cross-coupling due to unconnected cable shields. As a minimum, connect cable shields and the cores of power cables that are not used at one end at the grounded housing potential. WARNING Danger to life due to electric shock when not grounded For missing or incorrectly implemented protective conductor connection for devices with protection class I, high voltages can be present at open, exposed parts, which when touched, can result in death or severe injury. Ground the device in compliance with the applicable regulations. WARNING Danger to life due to electric shock when opening plug connections in operation When opening plug connections in operation, arcs can result in severe injury or death. Only open plug connections when the equipment is in a voltage-free state, unless it has been explicitly stated that they can be opened in operation. WARNING Danger to life due to fire spreading if the housing is inadequate Fire and smoke can cause severe injury or material damage. Install devices without a protective housing in a metal control cabinet (or protect the device by another equivalent measure) in such a way that contact with fire inside and outside the device is prevented. Ensure that smoke can escape via designated paths. 8 Operating Instructions, 04/2014, A5E00331462A

Safety information 1.1 General safety instructions WARNING Danger to life through unexpected movement of machines when using mobile wireless devices or mobile phones Using mobile radios or mobile phones with a transmit power > 1 W closer than approx. 2 m to the components may cause the devices to malfunction, influence the functional safety of machines therefore putting people at risk or cause material damage. When close to components, switch off all wireless devices and mobile phones. WARNING Danger to life due to the motor catching fire in the event of insulation overload There is a greater load on the motor insulation as result of a ground fault in an IT system. A possible result is the failure of the insulation with a risk for personnel as a result of fire and smoke. Use a monitoring device that signals an insulation fault. Correct the fault as quickly as possible so the motor insulation is not overloaded. WARNING Danger to life due to fire if overheating occurs because of insufficient ventilation clearances Inadequate ventilation clearances can cause overheating with a risk for personnel as a result of fire and smoke. This can also result in increased downtime and reduced service lives of devices/systems. Ensure compliance with the specified minimum clearances as ventilation clearance for the respective component. They can be found in the dimension drawings or in the "Product-specific safety instructions" at the start of the respective section. WARNING Danger of an accident occurring due to missing or illegible warning labels Missing or illegible warning labels can result in death or serious injury. Check the warning labels are complete based on the documentation. Attach any missing warning labels to the components, in the national language if necessary. Replace illegible warning labels. Operating Instructions, 04/2014, A5E00331462A 9

Safety information 1.1 General safety instructions NOTICE Device damage caused by incorrect voltage/insulation tests Incorrect voltage/insulation tests can damage the device. Before carrying out a voltage/insulation check of the system/machine, disconnect the devices as all converters and motors have been subject to a high-voltage test by the manufacturer, and therefore it is not necessary to perform an additional test within the system/machine. Note Use of copper cables for a UL-approved system For a UL-approved system use 60/75 C copper conductors only. 10 Operating Instructions, 04/2014, A5E00331462A

General 2 Description limit low-frequency line-side harmonics to permissible values. WARNING Danger to life if the fundamental safety instructions and remaining risks are not carefully observed The non-observance of the fundamental safety instructions and residual risks stated in Chapter 1 can result in accidents with severe injuries or death. Adhere to the fundamental safety instructions. When assessing the risk, take into account residual risks. CAUTION Risk of burns due to high surface temperature of the line reactor The line reactors can become very hot. You can get seriously burnt when touching the surface. Mount the line reactors so that contact is not possible. If this is not possible, attach clearly visible and understandable warning notices at hazardous positions. To prevent adjacent components from suffering damage due to these high temperatures, maintain a clearance of 100 on all sides of the line reactors. NOTICE Damage of the system caused by the use of inappropriate and not approved line reactors Inappropriate and not approved line reactors can damage the Line Modules. Line harmonics that damage/disturb other loads connected to the same line supply can also occur. Only use line reactors listed in this manual. Note Malfunctions through magnetic fields Reactors produce magnetic fields that can disturb or damage components and cables. Arrange the components and cables at a suitable distance (at least ) or shield the magnetic fields appropriately. Operating Instructions, 04/2014, A5E00331462A 11

General Note Length of connection cables The connection cables between line reactor and Line Module, as well as between line reactor and line filter, must be kept as short as possible (max. 5 m). You must use shielded connection cables, whose cable shields are attached at both ends. Shielding can only be omitted if the following conditions are met: The cables do not exceed 1 m in length. The cables are laid flush with the rear metal wall of the control cabinet. The cables are laid in a way that keeps them physically separate from signal cables. Do not route any cables near the line reactor. If this cannot be avoided, observe a minimum distance of. Assignment of line reactor and Power Module Table 2-1 Assignment of line reactor and Power Module Power Module Unit rating of the Power Module Suitable line reactor Line voltage 3-phase 380 480 VAC 6SL3310-1GE32-1AAx 110 kw 6SL3000-0CE32-3AA0 6SL3310-1GE32-6AAx 132 kw 6SL3000-0CE32-8AA0 6SL3310-1GE33-1AAx 160 kw 6SL3000-0CE33-3AA0 6SL3310-1GE33-8AAx kw 6SL3000-0CE35-1AA0 6SL3310-1GE35-0AAx 250 kw 6SL3000-0CE35-1AA0 6SL3310-1GE36-1AAx 315 kw 6SL3000-0CE36-3AA0 6SL3310-1GE37-5AAx 400 kw 6SL3000-0CE37-7AA0 6SL3310-1GE38-4AAx 450 kw 6SL3000-0CE38-7AA0 6SL3310-1GE41-0AAx 560 kw 6SL3000-0CE41-0AA0 Line voltage 3-phase 500 600 VAC 6SL3310-1GF31-8AAx 110 kw 6SL3000-0CH32-2AA0 6SL3310-1GF32-2AAx 132 kw 6SL3000-0CH32-2AA0 6SL3310-1GF32-6AAx 160 kw 6SL3000-0CH32-7AA0 6SL3310-1GF33-3AAx kw 6SL3000-0CH33-4AA0 6SL3310-1GF34-1AAx 250 kw 6SL3000-0CH34-8AA0 6SL3310-1GF34-7AAx 315 kw 6SL3000-0CH34-8AA0 6SL3310-1GF35-8AAx 400 kw 6SL3000-0CH36-0AA0 6SL3310-1GF37-4AAx 500 kw 6SL3000-0CH38-4AA0 6SL3310-1GF38-1AAx 560 kw 6SL3000-0CH38-4AA0 12 Operating Instructions, 04/2014, A5E00331462A

General Power Module Unit rating of the Power Module Suitable line reactor Line voltage 3-phase 660 690 VAC 6SL3310-1GH28-5AAx 85 kw 6SL3000-0CH31-1AA0 6SL3310-1GH31-0AAx 90 kw 6SL3000-0CH31-1AA0 6SL3310-1GH31-2AAx 110 kw 6SL3000-0CH31-6AA0 6SL3310-1GH31-5AAx 132 kw 6SL3000-0CH31-6AA0 6SL3310-1GH31-8AAx 160 kw 6SL3000-0CH32-2AA0 6SL3310-1GH32-2AAx kw 6SL3000-0CH32-2AA0 6SL3310-1GH32-6AAx 250 kw 6SL3000-0CH32-7AA0 6SL3310-1GH33-3AAx 315 kw 6SL3000-0CH33-4AA0 6SL3310-1GH34-1AAx 400 kw 6SL3000-0CH34-8AA0 6SL3310-1GH34-7AAx 450 kw 6SL3000-0CH34-8AA0 6SL3310-1GH35-8AAx 560 kw 6SL3000-0CH36-0AA0 6SL3310-1GH37-4AAx 710 kw 6SL3000-0CH38-4AA0 6SL3310-1GH38-1AAx 800 kw 6SL3000-0CH38-4AA0 Operating Instructions, 04/2014, A5E00331462A 13

General 14 Operating Instructions, 04/2014, A5E00331462A

Mechanical installation 3 Dimension drawing Figure 3-1 Dimension drawing of line reactor Operating Instructions, 04/2014, A5E00331462A 15

Mechanical installation Table 3-1 Dimensions of line reactor, 380 V 480 V 3 AC (all values in ) 6SL3000-0CE32-3AA0 0CE32-8AA0 0CE33-3AA0 0CE35-1AA0 0CE36-3AA0 0CE37-7AA0 0CE38-7AA0 0CE41-0AA0 a2 25 30 40 50 a3 5 6 8 8 a4 12.5 15 20 25 a5 11 14 14 14 I4 300 350 350 I5 88 100 120 120 h1 - - 392 397 h2 150 180 252 252 h3 60 60 120 120 h4 269 321 321 n1 1) 101 118 138 138 n2 1) 224 264 264 n3 212.5 211.5 211.5 n4 84.5 81 60 60 d3 M8 M8 M8 M8 1) Lengths n1 and n2 correspond to the drill hole spacing Table 3-2 Dimensions of line reactor, 500 V 600 V 3 AC (all values in ) 6SL3000-0CH32-2AA0 0CH32-7AA0 0CH33-4AA0 0CH34-8AA0 0CH36-0AA0 0CH38-4AA0 a2 25 30 40 a3 5 6 8 a4 12.5 15 20 a5 11 14 14 I4 350 410 I5 88 120 135 h1 - - 392 h2 150 198 252 h3 60 75 120 h4 321 385 n1 1) 101 138 141 n2 1) 264 316 n3 232.5 224 n4 84.5 81 56.5 d3 M8 M8 M10 1) Lengths n1 and n2 correspond to the drill hole spacing 16 Operating Instructions, 04/2014, A5E00331462A

Mechanical installation Table 3-3 Dimensions of line reactor, 660 V 690 V 3 AC (all values in ) 6SL3000-0CH31-1AA0 0CH31-6AA0 0CH32-2AA0 0CH32-7AA0 0CH33-4AA0 0CH34-8AA0 0CH36-0AA0 0CH38-4AA0 a2 25 30 40 a3 5 6 8 a4 12.5 15 20 a5 11 14 14 l4 350 410 l5 88 120 135 h1 - - 392 h2 150 198 252 h3 60 75 120 h4 321 385 n1 1) 101 138 141 n2 1) 264 316 n3 232.5 224 n4 84.5 81 56.5 d3 M8 M8 M10 1) Lengths n1 and n2 correspond to the drill hole spacing Operating Instructions, 04/2014, A5E00331462A 17

Mechanical installation 18 Operating Instructions, 04/2014, A5E00331462A

Electrical installation 4 Connection When connecting the line filter and line reactor, you must take into account the following conditions to ensure that they function correctly: Use shielded control cables. The shield must be connected at both ends. With analog control cables, connecting the shield at both ends can result in coupled-in noise. To prevent this, the shield must only be connected at one end on the Power Module. Control cables must be routed separately from power cables. Power cables are motor cables or connecting cables from the DC link of the Power Module (terminals DCPA/DCNA) to other components (e.g. Braking Module). In particular, you must ensure that control cables and power cables are not routed in parallel in a joint cable raceway, even if all the cables are shielded. You must use shielded motor cables. The shield for the motor cable must be attached to the shield plate and motor housing. The ground wire for the motor must be fed directly back to the Power Module. Connection overview Figure 4-1 Connecting the line filter, line reactor, and Power Module Operating Instructions, 04/2014, A5E00331462A 19

Electrical installation 20 Operating Instructions, 04/2014, A5E00331462A

Technical specifications 5 General technical data Table 5-1 General technical data Line frequency 47 to 63 Hz Product standard EN 61800-5-1 Ambient conditions Storage Transport Operation Ambient temperature -25 to +70 C -25 to +70 C 0 to +50 C Relative air humidity 1) (condensation not permissible) corresponds to 5 to 95 % 1K4 acc. to EN 60721-3-1 5 to 95% at 40 C 2K3 to EN 60721-3-2 5 to 95% 3K3 to EN 60721-3-3 class Mechanical strength Storage Transport Operation Vibrational load 1) - Displacement - Acceleration corresponds to class 1.5 at 5... 9 Hz 5 m/s² at > 9... Hz 1M2 to EN 60721-3-1 3.5 at 5... 9 Hz 10 m/s² at > 9... Hz 2M2 to EN 60721-3-2 0.075 at 10... 58 Hz 10 m/s² at >58... Hz - Shock load 1) - Acceleration corresponds to class 40 m/s² at 22 ms 1M2 to EN 60721-3-1 100 m/s² at 11 ms 2M2 to EN 60721-3-2 100 m/s² at 11 ms 3M4 to EN 60721-3-3 Deviations from the specified classes are shown in italics. 1) The EN standards specified are the European editions of the international IEC standards with the same designations. Operating Instructions, 04/2014, A5E00331462A 21

Technical specifications Detailed technical data Table 5-2 Technical data of line reactors, 380 V 480 V 3 AC, part 1 Order number 6SL3000-0CE32-3AA0 0CE32-8AA0 0CE33-3AA0 0CE35-1AA0 Suitable for Power Module 6SL3310-1GE32-1AAx 1GE32-6AAx 1GE33-1AAx 1GE33-8AAx Type rating of the Power Module kw 110 132 160 Rated voltage V 3 AC 380 10% to 3 AC 480 +10% (-15% < 1 min) Ithmax A 224 278 331 508 Power loss kw 0.274 0.247 0.267 0.365 Line/load connection 1U1, 1V1, 1W1, 1U2, 1V2, 1W2 Degree of protection IP00 IP00 IP00 IP00 Dimensions Width Height Depth Weight kg 24.5 26.0 27.8 38.0 300 269 212.5 Table 5-3 Technical data of line reactors, 380 V 480 V 3 AC, part 2 Order number 6SL3000-0CE35-1AA0 0CE36-3AA0 0CE37-7AA0 0CE38-7AA0 Suitable for Power Module 6SL3310-1GE35-0AAx 1GE36-1AAx 1GE37-5AAx 1GE38-4AAx Type rating of the Power Module kw 250 315 400 450 Rated voltage V 3 AC 380 10% to 3 AC 480 +10% (-15% < 1 min) Ithmax A 508 628 773 871 Power loss kw 0.365 0.368 0.351 0.458 Line/load connection 1U1, 1V1, 1W1, 1U2, 1V2, 1W2 Degree of protection IP00 IP00 IP00 IP00 Dimensions Width Height Depth 300 269 212.5 300 269 212.5 300 269 212.5 350 321 211.5 Weight kg 38.0 41.4 51.3 63.2 22 Operating Instructions, 04/2014, A5E00331462A

Technical specifications Table 5-4 Technical data of line reactors, 380 V 480 V 3 AC, part 3 Order number 6SL3000-0CE41-0AA0 Suitable for Power Module 6SL3310-1GE41-0AAx Type rating of the Power Module kw 560 Rated voltage V 3 AC 380 10% to 3 AC 480 +10% (-15% < 1 min) Ithmax A 1022 Power loss kw 0.498 Line/load connection 1U1, 1V1, 1W1, 1U2, 1V2, 1W2 Degree of protection Dimensions Width Height Depth IP00 350 321 211.5 Weight kg 69.6 Table 5-5 Technical data of line reactors, 500 V 600 V 3 AC, part 1 Order number 6SL3000-0CH32-2AA0 0CH32-2AA0 0CH32-7AA0 0CH33-4AA0 Suitable for Power Module 6SL3310-1GF31-8AAx 1GF32-2AAx 1GF32-6AAx 1GF33-3AAx Type rating of the Power Module kw 110 132 160 Rated voltage V 3 AC 500 10% to 3 AC 600 +10% (-15% < 1 min) Ithmax A 230 230 342 Power loss kw 0.275 0.275 0.277 0. Line/load connection 1U1, 1V1, 1W1, 1U2, 1V2, 1W2 Degree of protection IP00 IP00 IP00 IP00 Dimensions Width Height Depth Weight kg 31.1 31.1 27.9 38.9 Operating Instructions, 04/2014, A5E00331462A 23

Technical specifications Table 5-6 Technical data of line reactors, 500 V 600 V 3 AC, part 2 Order number 6SL3000-0CH34-8AA0 0CH34-8AA0 0CH36-0AA0 0CH38-4AA0 Suitable for Power Module 6SL3310-1GF34-1AAx 1GF34-7AAx 1GF35-8AAx 1GF37-4AAx Type rating of the Power Module kw 250 315 400 500 Rated voltage V 3 AC 500 10% to 3 AC 600 +10% (-15% < 1 min) Ithmax A 482 482 597 840 Power loss kw 0.478 0.478 0.485 0.618 Line/load connection 1U1, 1V1, 1W1, 1U2, 1V2, 1W2 Degree of protection IP00 IP00 IP00 IP00 Dimensions Width Height Depth 350 321 232.5 350 321 232.5 350 321 232.5 Weight kg 55.6 55.6 63.8 98 410 385 224 Table 5-7 Technical data of line reactors, 500 V 600 V 3 AC, part 3 Order number 6SL3000-0CH38-4AA0 Suitable for Power Module 6SL3310-1GF38-1AAx Type rating of the Power Module kw 560 Rated voltage V 3 AC 500 10% to 3 AC 600 +10% (-15% < 1 min) Ithmax A 840 Power loss kw 0.618 Line/load connection 1U1, 1V1, 1W1, 1U2, 1V2, 1W2 Degree of protection Dimensions Width Height Depth IP00 410 385 224 Weight kg 98 24 Operating Instructions, 04/2014, A5E00331462A

Technical specifications Table 5-8 Technical data of line reactors, 660 V 690 V 3 AC, part 1 Order number 6SL3000-0CH31-1AA0 0CH31-1AA0 0CH31-6AA0 0CH31-6AA0 Suitable for Power Module 6SL3310-1GH28-5AAx 1GH31-0AAx 1GH31-2AAx 1GH31-5AAx Type rating of the Power Module kw 75 90 110 132 Rated voltage V 3 AC 660 10% to 3 AC 690 +10% (-15% < 1 min) Ithmax A 107 107 164 164 Power loss kw 0.252 0.252 0.281 0.281 Line/load connection 1U1, 1V1, 1W1, 1U2, 1V2, 1W2 Degree of protection IP00 IP00 IP00 IP00 Dimensions Width Height Depth Weight kg 24.4 24.4 25.9 25.9 Table 5-9 Technical data of line reactors, 660 V 690 V 3 AC, part 2 Order number 6SL3000-0CH32-2AA0 0CH32-2AA0 0CH32-7AA0 0CH33-4AA0 Suitable for Power Module 6SL3310-1GH31-8AAx 1GH32-2AAx 1GH32-6AAx 1GH33-3AAx Type rating of the Power Module kw 160 250 315 Rated voltage V 3 AC 660 10% to 3 AC 690 +10% (-15% < 1 min) Ithmax A 230 230 342 Power loss kw 0.275 0.275 0.277 0. Line/load connection 1U1, 1V1, 1W1, 1U2, 1V2, 1W2 Degree of protection IP00 IP00 IP00 IP00 Dimensions Width Height Depth Weight kg 31.1 31.1 27.9 38.9 Operating Instructions, 04/2014, A5E00331462A 25

Technical specifications Table 5-10 Technical data of line reactors, 660 V 690 V 3 AC, part 3 Order number 6SL3000-0CH34-8AA0 0CH34-8AA0 0CH36-0AA0 0CH38-4AA0 Suitable for Power Module 6SL3310-1GH34-1AAx 1GH34-7AAx 1GH35-8AAx 1GH37-4AAx Type rating of the Power Module kw 400 450 560 710 Rated voltage V 3 AC 660 10% to 3 AC 690 +10% (-15% < 1 min) Ithmax A 482 482 597 840 Power loss kw 0.478 0.478 0.485 0.618 Line/load connection 1U1, 1V1, 1W1, 1U2, 1V2, 1W2 Degree of protection IP00 IP00 IP00 IP00 Dimensions Width Height Depth 350 321 232.5 350 321 232.5 350 321 232.5 Weight kg 55.6 55.6 63.8 98 410 385 224 Table 5-11 Technical data of line reactors, 660 V 690 V 3 AC, part 4 Order number 6SL3000-0CH38-4AA0 Suitable for Power Module 6SL3310-1GH38-1AAx Type rating of the Power Module kw 800 Rated voltage V 3 AC 660 10% to 3 AC 690 +10% (-15% < 1 min) Ithmax A 840 Power loss kw 0.618 Line/load connection 1U1, 1V1, 1W1, 1U2, 1V2, 1W2 Degree of protection Dimensions Width Height Depth IP00 410 385 224 Weight kg 98 26 Operating Instructions, 04/2014, A5E00331462A