Solder terminals D2FD-2L0-1H D2FD-01L0-1H. PCB terminals D2FD-2L0-1T D2FD-01L0-1T. Hinge lever Solder terminals D2FD-2L1-1H D2FD-01L1-1H

Similar documents
SS Series Compatible Mounting with a Simple Construction and Easy-to-Use Design Concept

Terminals Solder terminals Quick-connect. PCB terminals terminals (#110) 3 A Pin plunger SS-3GP SS-3GPT SS-3GPD SS-3GPB

D2F. Ultra Subminiature Basic Switch with plenty of terminal variations. Model Number Legend. Ultra Subminiature Basic Switch

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever

D2SW-3L1HS D2SW-01L1HS

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

Add S to the end of the model number for the UL/CSA-approved version. Consult your OMRON sales representative for details.

Pin plunger D2JW-011 D2JW-011-MD. Short hinge lever D2JW-01K1A1 D2JW-01K1A1-MD. Hinge lever D2JW-01K11 D2JW-01K11-MD

Quick-connect terminals (#110)

Actuator Terminal Model

Special-purpose Basic Switch

Ordering Information. Snap Action Switch V. Model Number Legend V General Purpose Snap Action Switch. Snap Action Switch V 121

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

Ordering Information. Door Interlock Switch D2D. Power Switch with Minimum Contact Gap up to 3 mm. D2D - 0. Model Number Legend

Miniature Basic Switch

Basic Switch. Pin plunger Short hinge Hinge lever Long hinge lever Simulated hinge Short hinge Hinge roller lever lever roller lever lever

masterelectronics.com onlinecomponents.com

Contact form. Operating Force. Plunger SPDT 204g Dust- Proof (in closed position) Plunger SPST-NC 204g Dust- Proof (in closed position)

DPDT Basic Switch for Two Independent Circuit Control

Top-actuated (B3U-1000 Series)

Z-15GW2277 Z-15GW2277-B

Snap Action Switch. General- Low force 25 g D2F-FL D2F-FL-T D2F-FL-D D2F-FL-A D2F-FL-A1

7. Approved Standards US: UL, CSA UL: FILE No.E CSA: FILE No.LR31928) 8. Special Function None : Standard U : For ultrasonically cleanable

D3SK. The smallest detection switch in the industry with high precision operation. ( mm (W D H)) List of Models. Surface Mount Switch

Contact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect

D3SH. List of Models. Surface Mount Switch S H SPST-NO SPST-NC. Long Lever Models. Standard Lever Models


Contact form. Operating Force. SPDT 100g Unsealed Solder / 187 Quick Connect. SPDT 200g Unsealed Solder / 187 Quick Connect

HIGH PERFORMANCE MINIATURE SWITCHES WITH WIDE RANGE

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure

Inductive Proximity Sensor

Inductive Proximity Sensor

ZE/ZV/ZV2/XE/XV/XV2. (1) Built-in Switch (3) Actuator (4) Conduit/Ground Terminal *

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

5. Terminal Shape P: PCB Terminals 6. Classification None : Standard ST : Stand-off 0.64 mm 15 : High-sensitivity (150 mw) Low-sensitivity

Miniature Inductive Prox TL-W

Model Number Structure

Cylindrical Proximity Sensor

ZE/ZV/ZV2/XE/XV/XV2. General-purpose Enclosed Switches with High Breaking Capacity and High Durability. Enclosed Switches. Model Number Structure

General-purpose Limit Switch

Origin Position Control of an X-Y Table Coaxiality Inspection Checking Turret Indexing Position D5A

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Miniature Enclosed Limit Switch

Miniature Basic Switch

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Thread length (overall length) material

2. Actuator B: Ball type P: Pin type F: Flat type

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Item E2CD-C1C3A E2CD-C1R5C3A E2CD-X2R5C3A E2CD-X5C3A 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated

E2EC-CR8D2 5.4 mm dia. 1.5 mm (0.06 in) NO E2EC-C1R5D1 NC. E2EC-C1R5D2 8mmdia. 3 mm (0.12 in) NO E2EC-C3D1 NC

Aluminum-detecting Proximity Sensor (Separate Amplifier Type)

E2CY-SD. Proximity Sensor with Separate Amplifier Unit for Detection of Non-ferrous Metals with Simple Sensitivity Adjustment

Mini Photoelectric Sensor

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC

E2EC. High-sensitivity DC 2-Wire Sensors and Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

XC5. DIN-style Twin-contact Connectors. Expanding the DIN Concept. Materials and Finish. Ratings and Characteristics

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit)

Actuator Series Common to Miniature, V-Size models

14CESeries. Miniature Pre-Leaded Vertical Enclosed Switches

XH2. Half-pitch Board-to-Board Connectors

G3VM Series. Selection Guide. MOS FET Relays. A wide range of contact forms and functions Over 250 different models available

Technical Information Tactile Switches

XC7. DIN Sequence Connectors. An improved DIN-standard Sequence. Connectors. connectors. Ratings and Characteristics. Materials and Finish

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

E2K-X4ME1 2M E2K-X4ME2 2M

Model Number Structure

Model Number Structure

E4PA. Ultrasonic Displacement Sensor. Ordering Information

Thread length (overall length)

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor.

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Switching Power Supply

Product Discontinuation Notices. Discontinuation Notice of Compact proximity sensor TL-M series (for china area only)

Features Sealed Construction for Automatic Soldering. Contact form. Operating Force SPST- NO SPST- NO SPST- NO SPST- NO SPST- NO SPST- NO SPST- NO

Model Number Structure

E2Q4 Square Proximity Sensor

Electroformed Probe Pin

DIP Switch (Slide Type)

Switching Power Supply

S8VE (60/90/120/180/240-W Models)

Model Number Structure

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Handheld Reader Writer

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

Model Number Structure

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

Three-phase Voltage Relay

Model Number Structure

Compact-sized Snap Action Switches (Contact gap is more than 1mm) MQS-54AS Series 1/10

MICRO SWITCH Sealed Subminiature Basic Switches. ZW Series. Datasheet

V-3000 Series Miniature Basic Switches

Transcription:

Ultra subminiature and dust proof Sealing by using rubber packing means the switch can be used in dust-proof environments (IEC IP6X). Switch rating of 2 A at 125 VAC possible with a single-leaf movable spring. s for micro loads are also available. Solder and PCB terminals are available. RoHS Compliant Number Legend 1. Rating 2 : 2 A at 125 VAC / 0 VDC 01 : 0.1 A at 125 VAC / 0 VDC D2FD-@@-1@ 1 2. Terminals H : Solder terminals T : PCB terminals 2. Actuater L0 : Pin plunger L1 : Hinge lever L0 : Simulated roller lever List of s Pin plunger Actuator Ratings Terminals 2 A 0.1 A Solder terminals D2FD-2L0-1H D2FD-01L0-1H PCB terminals D2FD-2L0-1T D2FD-01L0-1T Hinge lever Solder terminals D2FD-2L1-1H D2FD-01L1-1H PCB terminals D2FD-2L1-1T D2FD-01L1-1T Simulated roller lever (R2.5) Solder terminals D2FD-2L0-1H D2FD-01L0-1H PCB terminals D2FD-2L0-1T D2FD-01L0-1T Contact Form SPDT COM NO NC 1

Contact Specifications Item D2FD-2 models D2FD-01 models Contact Note: For more information on the minimum applicable load, refer to Using Micro Loads. Ratings Note: The rating values apply under the following test conditions. 1. Ambient temperature: 20 ± 2 C 2. Ambient humidity: 65 ± 5%. Operating frequency: 20 operations/min Characteristics Specification Crossbar Material Silver alloy Gold alloy Gap (standard value) 0.25 mm Minimum applicable load (see note) 100 ma at 5 VDC 1 ma at 5 VDC Rated voltage D2FD-2 models D2FD-01 models Resistive load 125 VAC 2 A 0.1 A 0 VDC 2 A 0.1 A Item D2FD-2 models D2FD-01 models Operating speed Operating frequency Insulation resistance Mechanical Electrical 1 mm to 500 mm/s 120 operations/min max. 20 operations/min max 100 MΩ min. (at 500 VDC) Contact resistance (initial value) 0 mω max. 100 mω max. 600 VAC 50/60 Hz 1 min between terminals of same polarity Dielectric strength (see note 2) 1,500 VAC 50/60 Hz 1 min between current carrying metal parts and ground 1,500 VAC 50/60 Hz 1 min between each terminal and non-current carrying metal part Vibration resistance (see note ) Malfunction 10 to 55 Hz, 1.5 mm double amplitude Shock resistance (see note ) Durability (see note 4) Degree of protection Ambient operating temperature Ambient operation humidity Weight Destruction Malfunction Mechanical 1,000 m/s 2 max. 00 m/s 2 max. 00,000 operations min. (at 60 ops./min.) Electrical 0,000 operations min. (at 20 ops./min.) 100,000 operations min. (at 20 ops./min.) Note: 1. The data given above are initial values. 2. The dielectric strength shown in the table indicates a value for models with a Separator.. For the pin plunger models, the above values apply for both the free position and total travel position. For the lever models, the values apply at the total travel position. Contact opening or closing time is within 1 ms. 4. Consult your OMRON sales representative for testing conditions. IP6X 20 to +70 C (at 60%RH max.) (with no icing) 85%RH max. (for +5 to +5 C) Approx. 0.7 g (pin plunger, PCB terminal models) Terminals (Unit: mm) Solder Terminals PCB Terminals PCB Mounting Dimensions (Reference) 2.5±0.1 +0.1 2.4 0.05 Dia. 5±0.15 +0.12 Two,1.2 0 Dia. Three, 1.2±0.05 Dia. 2.4 +0.1 0.05 1.2 2.2 4 4.8±0.1 5.08±0.15 5.08±0.15 12.8±0.15 1.7 1.5 2 0.5 5.7 4.4 6 0.4 5.5 1.5±0.1 1.1±0.12 0.4 1.5±0.12 Three, R0.8.15 6.5±0.1 0.9 1.25±0.12 5.08±0.15 5.08±0.15 4.4 12.8±0.15 6 1.6 5.08±0.1 5.08±0.1 Mounting Holes (Unit: mm) Solder Terminals Two, M2. 4.8±0.1 2

Dimensions (Unit: mm) / Operating Characteristics The following illustrations and drawings are for solder terminal models. PCB terminal models are omitted from the drawings. Refer to Terminals for these terminals. When ordering, replace @ with the code for the rating that you need. For the combination of models, refer to List of s. Pin Plunger s D2FD-@L0-1H D2FD-@L0-1T 2.4 +0.1 0.05 A 2.5±0.1 4.5 +0.1 2.4 0.05 Dia. PT 1.2 Dia. PT max. D2FD-@L0-1H D2FD-@L0-1T 2.00 N {204 gf} 0.25 N {25 gf} 0.6 mm 0.25 mm 0.12 mm 7.0 ± 0.2 mm 7.0 ± 0. mm Hinge Lever s D2FD-@L1-1H D2FD-@L1-1T t = 0. Stainless-steel lever 5.25 A FP FP max. D2FD-@L1-1H D2FD-@L1-1T 0.65 N {66 gf} 0.05 N {5 gf} 11. mm 8. ± 1.0 mm 8. ± 1.2 mm Simulated Roller Lever s (R2.5) D2FD-@L0-1H D2FD-@L0-1T 4.2 A D2FD-@L0-1H D2FD-@L0-1T t = 0. Stainless-steel lever R2.5 0.65 N {66 gf} 0.05 N {5 gf} FP FP max. 14. mm 11. ± 1.0 mm 11. ± 1.2 mm Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 2. The operating characteristics are for operation in the A direction ( ).

Precautions Refer to General Information. Cautions Degree of Protection Do not use the Switch under the environment where it is exposed to water. The degree of protection is IP6X and the protection against water is not defined. Prevent the Switch from coming into contact with oil and chemicals. Otherwise, damage to or deterioration of Switch materials may result. Do not use the Switch in areas where it is exposed to silicon adhesives, oil, or grease, otherwise faulty contact may result due to the generation of silicon oxide. The environment-resistant performance of the switch differs depending on operating loads, ambient atmospheres, and installation conditions, etc. Please perform an operating test of the switch in advance under actual usage conditions. Terminal Connection When soldering a lead wire to the terminal, first insert the lead wire conductor into the terminal hole and then perform soldering. Make sure that the capacity of the soldering iron is 0 W maximum and that the temperature of the soldering iron tip is approximately 00 C. (50 C maximum.) Complete the soldering within s. Using a switch with improper soldering may result in abnormal heating, possibly resulting in burn. Applying a soldering iron for more than s or using one that is rated at more than 0 W may deteriorate the switch characteristics. When using automatic soldering baths, we recommend soldering at 260 ± 5 C within 5 seconds. Make sure that the liquid surface of the solder does not flow over the edge of the board. Correct Use Mounting Turn OFF the power supply before mounting or removing the Switch, wiring, or performing maintenance or inspection. Failure to do so may result in electric shock or burning. Use M2. mounting screws with plane washers or spring washers to securely mount the Switch. Tighten the screws to a torque of 0.20 to 0.29 N m {2.0 to 2.9 kgf cm}. Exceeding the specified torque may result in deterioration of the sealing or damage. Mount the Switch onto a flat surface. Mounting on an uneven surface may cause deformation of the Switch, resulting in faulty operation or damage. Operating Body Use an operating body with low frictional resistance and of a shape that will not interfere with the sealing rubber, otherwise the plunger may be damaged or the sealing may deteriorate. With the pin plunger models, set the Switch so that the plunger can be pushed in from directly above. Since the plunger is covered with a rubber cap, applying a force from lateral directions may cause damage to the plunger or reduction in the sealing capability. Handing Do not handle the Switch in a way that may cause damage to the sealing rubber. When handling the Switch, ensure that uneven pressure or, as shown in the following diagram, pressure in a direction other than the operating direction is not applied to the Actuator, otherwise the Actuator or Switch may be damaged, or durability may be decreased. Using Micro Loads Correct Using a model for ordinary loads to open or close the contact of a micro load circuit may result in faulty contact. Use models that operate in the following range. However, even when using micro load models within the operating range shown below, if inrush current occurs when the contact is opened or closed, it may increase contact wear and so decrease durability. Therefore, insert a contact protection circuit where necessary. The minimum applicable load is the N-level reference value. This value indicates the malfunction reference level for the reliability level of 60% (λ 60). The equation, λ 60 = 0.5 10-6 /operations indicates that the estimated malfunction rate is less than 1/ 2,000,000 operations with a reliability level of 60%. Voltage (V) 0 24 0.16 ma 16.6 ma 100 ma 12 Inoperable range 5 1 ma Operating range for micro load models D2FD-01 Operating range for general-load models D2FD-2 0 0.1 1 10 100 1,000 Current (ma) 4

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.097. To convert grams into ounces, multiply by 0.0527. Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb OMRON ELECTRONIC COMPONENTS EURE B.V. Wegalaan 57, 212 JD Hoofddorp,THE NETHER LANDS Tel: (1)2-568-1200/Fax: 1-2-568-1212 OMRON ELECTRONIC COMPONENTS LLC 55 East Commerce Drive, Suite B, IL 6017 U.S.A. Tel: (1)847-882-2288/Fax: 1-847-882-2192 OMRON ELECTRONIC COMPONENTS PTE LTD. 48A Alexandra Road #05-05/08 Alexandra Technopark Singapore 119967 TEL:(65)676-200/FAX:(65)676-211 OMRON ELECTRONIC COMPONENTS TRADING (SHANGHAI) LTD. SHANGHAI OFFICE 27F Xin Mei Union Square, 999 Pudong South Road, Pudong New Area, Shanghai, CHINA 200120 Tel: (86)21-6859-5919/Fax: 86-21-6859-5911 OMRON ELECTRONIC COMPONENTS CO., LTD. 14F, Daegong Bldg. #82-21, Yeoksam-dong, Gangnam-gu, Seoul, Korea, 15-080 Tel:(82)2-567-5020/Fax:(82)2-567-5804 Authorized Distributor: OMRON Corporation 2012 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Cat. No. B119-E1-01 012