Enterprise Historian TM History Services. Version 2.4/1 Patch 8. Release Notes

Similar documents
Enterprise Historian TM History Services. Version 2.4 Patch 13. Release Notes

Inform IT. Enterprise Historian TM and Profile Historian. Release Notes. Version 3.2/1 Patch 4 for History Services

System 800xA 800xA for Freelance VB Graphics Extension Installation

Engineering Manual Security Lock

A9890A RAID Smart Array 6402 Controller Quick Installation Guide

Device Management Basic HART DTM 6.0 Installation

800xA History 800xA History Rollup 2 Version RU2 Release Notes

ABB Robotics. Product manual USB disk drive replacement kit

Installation Guide for Open VMS

ABB Robotics. Product manual USB disk drive replacement kit

Produce IT Batch. Features and Benefits. Overview. Version 1.2

System Manager Unit (SMU) Hardware Reference

System 800xA 800xA for Freelance Product Guide

Oracle Tuxedo Mainframe Adapter for OSI TP

TECHILA WORKER INSTALLATION GUIDE LINUX ADMINISTRATOR GUIDE

800xA History. Installation. Power and productivity for a better world TM. System Version 6.0

System 800xA Public Address System User Manual

OrbixTalk 3.3 Installation Guide Windows NT, Solaris, and HP/UX

Blackbaud, Inc. This publication, or any part thereof, may not be reproduced or transmitted in any form or by any means, electronic, or

DDR. User s Guide ND040012E. We reserve all rights in this document and in the information contained therein. Copyright 2014 Newcon Data AB

Converged Network Analyzer Command Reference Guide Addendum

System 800xA Maintenance

Full User Manual and Quick Start Guide

EXPRESSBUILDER 3.005b-G Update Notes

SAP Workforce Performance Builder 9.5

HP Internet Usage Manager Software Release Notes

Visara Master Console Center. Software Installation P/N

VERITAS Storage Migrator 3.4 VERITAS Storage Migrator Remote 3.4

BIOS Update and Management. Motherboard

Veritas NetBackup Vault Administrator s Guide

ABB Robotics. Application manual Mechanical Unit Manager

x10data Application Platform v7.1 Installation Guide

How to install the software of ZNS8022

Team 7000 V2.0.0 for HPUX/HPOV4

Installation Instructions for SAS Foundation for UNIX Environments

ABB University (UK) Advant MOD Supplement. Course Descriptions. From Industrial Revolution to Industrial IT

Upgrading Prime Optical

Blackbaud, Inc. This publication, or any part thereof, may not be reproduced or transmitted in any form or by any means, electronic, or

HP StorageWorks Performance Advisor. Installation Guide. Version 1.7A

EXPRESSCLUSTER X Integrated WebManager

FOR NETWARE. Tested and. Approved

Team 7000 V2.1.0 for HPUX/HPOV4

System 800xA. 800xA History Installation Manual. System Version 6.0

CS SoftDent Practice Management Software Installation Guide for Client/Server Configurations

Update Guide V7.5.18

HP-UX System Administration

Mounting and Unmounting the CD-ROM

Lionstracs Groove X-R

HP OmniBook DiagTools. User s Guide

Configuring the MSA1000 for Linux or NetWare Environments

Agile e Installation Manual for Agile e6.0.2 Java Client on UNIX. Part Number: INSJAVAUNIX-602A

Image Backup and Recovery Procedures For Windows 7

HP / HP HPIB Driver Installation and Troubleshooting ChemStation Version A.07.0x- A.08.0xon Windows NT

Reborn software ADV 9.01 installation guide custom installation

AccessData FTK Quick Installation Guide

x10data Smart Client 6.5 for Windows Mobile Installation Guide

System 800xA Engineering

SonicWall Secure Mobile Access SMA 500v Virtual Appliance 8.6. Getting Started Guide

User s Guide February 28, 2017

System 800xA. Engineering and Production Environments. Power and productivity for a better world TM. System Version 5.1

Version 14.0 (and higher) Component Installation and Configuration. September 21, 2009

Agilent E2094M IO Libraries

Upgrading the MSA1000 for Enhanced Features

Agilent OpenLAB Chromatography Data System (CDS)

Tivoli SecureWay Policy Director WebSEAL. Installation Guide. Version 3.8

VERITAS Storage Solutions and VERITAS Cluster File Solutions 3.5

April UNIX Installation Guide

Data Protector Express Hewlett-Packard Company

System Management Guide Version 7.4a

Agile e Installation Manual for Agile e6.0.2 on UNIX Server. Part Number: INSUNIX-602A

ExpressCluster X Integrated WebManager

Dell Statistica. Statistica Enterprise Server Installation Instructions

Installation Guide. NSi AutoStore TM 6.0

System Management Guide Version 7.52

Fiery proserver User Guide

Oil and Gas SCADAvantage TM Product Update version ABB

Relius Administration Version 16.0 (and higher) Component Installation and Configuration. July 6, 2011

RADview-EMS/TDM (Unix)

Tofino CMP Installation & Upgrade Guide Tofino CMP Version Tofino Firmware Version 1.7.0

TECHILA WORKER INSTALLATION GUIDE WINDOWS ADMINISTRATOR DOCUMENT

KVS Enterprise Server Installation NOTE:

ALLIEDVIEW-UM 1.6 USER'S GUIDE

KODAK Dental Imaging Software Installation Guide

Quick Setup & Getting Started

User s Guide for SAS Software Navigator

Installation Instructions for SAS Foundation for UNIX Environments

CONSOLIDATING SQL SERVER 2008 ONTO DELL POWEREDGE R900 AND POWEREDGE R905 USING MICROSOFT S HYPER-V

Installing Essentials

USB Personal Video Recorder. USB Hybrid TV Tuner. (USB2.0 / 1.1 PNP TV Capture Box) UAD-880 User s Guide

Veritas NetBackup Backup, Archive, and Restore Getting Started Guide. Release 8.1.2

82341C HPIB Installation and Troubleshooting Agilent ChemStations on Windows 95 and Windows NT

TRUEGRID WINDOWS INSTALLATION/LICENSING/UPGRADES

HP VMware ESXi and vsphere 5.x and Updates Getting Started Guide

HP LeftHand SAN Solutions

Authentication Services ActiveRoles Integration Pack 2.1.x. Administration Guide

Step by Step Installation of CentOS Linux 7 and Active Circle

HP integrated Citrix XenServer Online Help

Configuring the HP StorageWorks Modular Smart Array 1000 and 1500cs for external boot with Novell NetWare New Installations

Installing and Upgrading Cisco Network Registrar Virtual Appliance

Stellar Phoenix Password Recovery For Windows Server. Version 2.0. User Guide

Transcription:

Enterprise Historian TM History Services Version 2.4/1 Patch 8 Release Notes

NOTICE The information in this document is subject to change without notice and should not be construed as a commitment by ABB Inc. ABB Inc. assumes no responsibility for any errors that may appear in this document. In no event shall ABB Inc. be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, nor shall ABB Inc. be liable for incidental or consequential damages arising from use of any software or hardware described in this document. This document and parts thereof must not be reproduced or copied without written permission from ABB Inc., and the contents thereof must not be imparted to a third party nor used for any unauthorized purpose. The software or hardware described in this document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license. This product meets the requirements specified in EMC Directive 89/336/EEC and in Low Voltage Directive 72/23/EEC. Copyright 2004 ABB Inc. All rights reserved. Release: October 2004 Document number: 3BUF001132D1 TRADEMARKS Registrations and trademarks used in this document include: Windows Enterprise Historian Registered trademark of Microsoft Corporation. Trademark of ABB Inc.

TABLE OF CONTENTS Section 1 - Introduction Product Overview...5 Prerequisites and Requirements...5 Section 2 - Functionality Fixed Problems...6 Section 3 - Installation Introduction...8 Updating the Enterprise Historian Version 2.2/1 Platform...8 Backing Up Your System...8 Adding /cdrom with sam...9 Preparing the CD-ROM for Installation...10 Instructions for Station(s) to be Updated...10 Post Installation...13 Log File Update...13 Updating the Operator Station 1.9/1 Platform...14 Backup...14 Adding /SD_CDROM with sam...14 Preparing the CD-ROM or DVD-ROM for Installation...15 Instructions for Station(s) to be Updated...15 Finishing Instructions...18 Optional User Log...19 3BUF001132D1 3

Section 1 Introduction Product Overview These release notes describe patch 8 for Enterprise Historian History Services version 2.4/1 for the HP-UX platform. This patch can be applied to systems with: Enterprise Historian version 2.2/1 MOD 300 OS1.9/1Pm where m = any patch. The patch can be applied to History version 2.4/1. Patches 1 through 7 were included in the 2.4/1 base release. The problems fixed by this patch are described in Section 2, Functionality. Instructions for installing this patch are provided in Section 3, Installation. Prerequisites and Requirements The History Services software on the Enterprise Historian or Operator Station platform must be at Version 2.4/1 to install this patch. 3BUF001132D1 5

Fixed Problems Section 2 Functionality Section 2 Functionality Fixed Problems Table 1 describes the problems that are fixed by patch 8. Table 1. Problems Fixed by History 2.4/1 Patch 8 ID Description 3184 Batch 300/TCL duplicate message problem. After a duplication PDL could not match the end times with the correct start times and the last entry did not have an end time. Added a queue of the last x messages that come into the hsmodinterface process. The HS_PDL_DUPCHECK_ON environment variable enables this feature. This variable must be set to a number from 1 to 999, which will be used to determine the size of the queue which typically should need to be no more than about 10 to 20. Once this variable is set the next time history restarts, the hsmodinterface process will begin checking for duplicate messages. As the root user, edit the file ocsenvironment located in: /home/ocsmgr/etc and add the following line in the same location as the other variables (using 20 for example): export HS_PDL_DUPCHECK_ON=20 3104 The hsarchive crashed when archiving PDL data. A problem was found with an oracle query that was overwriting the stack. This was caused when PDL archive had 1 byte of memory on the stack that could be set to zero. The location was random and could be anything from an address to a variable on the stack. Now, a corrected macro is called to look at the indicator variable to see if the value is null, and with null terminating the string properly. 3098 Modify Node List on Composite Log Display did not show connect nodes. You can now configure distributed logs for an EH Connect Node using the History Builder on the Consolidate Node and the Connect Node will be represented in Modify Node list in the Composite Log window. 6 3BUF001132D1

Section 2 Functionality Fixed Problems Table 1. Problems Fixed by History 2.4/1 Patch 8 ID Description 3086 The message dialog in DataDirect could not retrieve diagnostic messages and a query returned no data. The msgtype_id table in Oracle was lacking message type #7 which represents diagnostic messages. It is now added. 3084 hscollection spun with 100% CPU after an upgrade. At an earlier stage in hscollection, bmoredata was set before the request for TTD data was made. If the TTD was configured improperly, it was possible for the response to return with zero value and never catch up. However, collection kept trying to catch up by sending requests over. To correct the problem, if no values are returned and the bmoredata bit is set, the bit is cleared and an error message is logged. The clearing of the bit will prevent the 100% CPU usage. Examine the $HS_LOG/hsCollection0.log for errors. Logs configured incorrectly should be deleted or deactivated. 3083 When hsdbmaint was used to correct a corrupt HSFF file, all state files ( hscsnapshot and hssstoreage ) were deleted and the report_entry table was truncated. The behavior has been changed to only truncate the report entry table and delete the state files when all_logs are specified. 3070 hspdlmaint and hsdbmaint did not work properly when checking the restored PDL tables. 3031 Having _IP" characters show up in the name of a PPA object (O3_IPT_LPT_LK_W), to which a message log is attached, no longer interprets these characters as the IP address of the History node when saving composite log name in Oracle. 3BUF001132D1 7

Introduction Section 3 Installation Section 3 Installation Introduction Please review all the instructions, and your ABB Support terms and conditions, for precautions, scope of license, restrictions, and limitation of liability and warranties, before installing this software. In case of difficulties, please contact the Technical Support Group via SUPPORTLINE: in the U.S. - (1-800-HELP-365); International - (1-614-224-5888). This patch can be applied to systems with Enterprise Historian version 2.2/1, or MOD 300 OS1.9/1Pm. The History Services software on the Enterprise Historian or Operator Station platform must be at Version 2.4/1 to install this patch. Refer to the applicable update procedure based on the platform where you are installing the patch: Updating the Enterprise Historian Version 2.2/1 Platform Backing Up Your System It is strongly recommended that you perform a full backup of your system and application data before installing any new software. For information on backing up your station, please refer to the Enterprise Historian for HP-UX Version 2.2/1 Administrator s Guide. 8 3BUF001132D1

Section 3 Installation Adding /cdrom with sam Adding /cdrom with sam The following procedures must be performed when you are installing the patch from CD-ROM: Adding /cdrom with sam on page 9 Preparing the CD-ROM for Installation on page 10 These procedures prepare the CD-ROM reader to load the patch to the local station. If you received the software depot by some other means, disregard these two procedures and go directly to Instructions for Station(s) to be Updated on page 10. If you are installing from CD-ROM, the /cdrom directory must exist before adding this patch to the system. Check to see if the /cdrom directory exists by entering ls / and looking for the /cdrom directory name. If it does not already exist, follow the instructions below for adding the /cdrom directory with sam. If it does exist, skip these instructions and continue on to Preparing the CD-ROM for Installation below. To add the /cdrom directory: 1. In an HP terminal window, log on as the root user by entering: su root 2. Enter sam 3. Within SAM Areas window, select Disks and File Systems 4. Within SAM Areas: Disks and File Systems window, select Disk Devices 5. Within Disk Devices window, select CD from SCSI list of devices 6. Under Actions, Select Add -> Not Using the Logical Volume Manager 7. Within Add CD_ROM Disk window, enter /cdrom as Mount Directory: 8. In When to mount area, deselect Now. Leave At every system boot selected. 9. Click OK. 10. File -> Exit 11. File -> Exit SAM. 3BUF001132D1 9

Preparing the CD-ROM for Installation Section 3 Installation Preparing the CD-ROM for Installation If you are installing from CD-ROM, the /cdrom filesystem must be mounted before adding this patch to the system. To see if it is mounted, enter bdf at the UNIX prompt, and look for information about the /cdrom filesystem in the command output. If the filesystem is not mounted, follow the instructions below to mount it. If it is mounted, skip this section and proceed to Instructions for Station(s) to be Updated below. 1. In an HP terminal window, log on as the root user 2. Insert the Patch ABB-PHSU_241008 CD-ROM into the CD-ROM drive 3. Enter mount /cdrom If the mount fails with the following message: mount: /cdrom was either ignored or not found at /etc/fstab, follow the instructions in Adding /cdrom with sam on page 9. 4. Enter: swreg -l depot /cdrom This command only needs to be entered one time before loading the first station. Instructions for Station(s) to be Updated Before installing, you will need to stop all software on the Station (including Enterprise Historian software): 1. Open a terminal window and log in as the root user. Enter su root (super user). 2. Enter /opt/advant/startup/bin/imsstop -v If the Station with Enterprise Historian software is shut down in an uncontrolled way, the relational database may crash and the data may become corrupt. If the station has to be rebooted, use the HP-UX shutdown command. This command executes the IMSstop script. 3. If you are loading from a.depot file, go to Step 4. 10 3BUF001132D1

Section 3 Installation Instructions for Station(s) to be Updated If you are loading from CD-ROM, insert the Patch ABB-PHSU_241008 CD-ROM into the CD-ROM drive, then a. Load the patch by entering: /usr/sbin/swinstall -s <hostname>:/cdrom <hostname> is hostname or IP address of Advant Station with CD-ROM drive attached. b. Go to Step 6. 4. Put the file you have received (ABB-PHSU_241008.depot) on the Enterprise Historian, for example under the /tmp directory. 5. Enter: /usr/sbin/swinstall -s /tmp/abb-phsu_241008.depot This brings up the SD Install - Software Selection (station) window. If you get an error dialog indicating that The current session cannot be saved... Make sure that the HOME Environment variable is set, click OK to continue. This error may occur that this point, or later in the process. 6. Under the Actions menu select Match what Target Has. This will select the proper licensed options on your system to update (including History, and/or PDL and/or SPC). Ignore errors regarding fileset dependencies. Exit the dialog to continue the installation. 7. Under the Actions menu select Install (Analysis). 8. After analysis is complete, select the Logfile button to bring up the swagent.log file. Search for the correct date and time heading. Check for any messages that begin with ERROR or WARNING. When satisfied, select OK to exit the log file. 9. Select OK, then Yes to begin the installation. 3BUF001132D1 11

Instructions for Station(s) to be Updated Section 3 Installation 10. When the installation has completed, again select the Logfile button to bring up the swagent.log file in the window. Search for the correct date and time heading. Check for any messages that begin with ERROR or WARNING. When satisfied, select OK to exit the log file. Select DONE to finish the installation. 11. Under the File menu select Exit to end the swinstall process. 12. If you are loading from CD-ROM, remove the CD from the drive. 13. Execute the swlist command in an HP terminal window to view the History version. Verify the version is 02.04.01.08, Figure 1. Verify History Version Figure 1. Verifying the History Version 14. As root user restart IMS processes. Enter: /opt/advant/startup/bin/imsstart 15. Perform the post installation procedures as described in Post Installation on page 13. 12 3BUF001132D1

Section 3 Installation Post Installation Post Installation Log File Update Whenever a patch is installed on a system, you should edit the Text File user_update.log found in the /var/adm/sw directory. At the end of the file, add History Version 2.4/1 Patch 8 Installed, the date, and description if desired. Any other changes made to the product, such as custom memory pool changes may also be added. The file should be created if it does not exist. You may make the file name more application specific, such as user_update_eh2.2-1.log, and rename the file at each software update step along the way. The purpose of the text file is to prevent the deletion of certain user critical changes during a reloading or updating of a machine. 3BUF001132D1 13

Updating the Operator Station 1.9/1 Platform Section 3 Installation Updating the Operator Station 1.9/1 Platform Backup You should backup your Operator Station before upgrading. If necessary, you can use this backup to restore your data. For information on backing up and restoring your OS, please refer to the Advant Station 500 Series with AdvaCommand 1.9/1 AdvaBuild 2.9/2 User s Guide. The following procedures must be performed when you are installing the patch from CD-ROM: Adding /SD_CDROM with sam on page 14 Preparing the CD-ROM or DVD-ROM for Installation on page 15 These procedures prepare the CD-ROM reader to load the patch to the local station. If you received the software depot by some other means, disregard these two procedures and go directly to Instructions for Station(s) to be Updated on page 10. Adding /SD_CDROM with sam These instructions must be performed to prepare the CD-ROM or DVD-ROM reader to load the software to the local station or remote stations. These instructions need only be performed one time before loading one or more stations. The /SD_CDROM directory must exist before adding this update CD-ROM to the system. Check to see if the /SD_CDROM directory exists by entering ls / and looking for it. If it does not already exist, follow the instructions below for adding the /SD_CDROM directory with sam. If it does exist, skip these instructions and continue on to Section, Installation. These instructions must be performed to add the /SD_CDROM directory. 1. In an HP terminal window, log on as the root user. 2. Enter sam 3. Within SAM Areas window, select Disks and File Systems 14 3BUF001132D1

Section 3 Installation Preparing the CD-ROM or DVD-ROM for Installation 4. Within SAM Areas: Disks and File Systems window, select Disk Devices 5. Within Disk Devices window, select CD from SCSI list of devices 6. Under menu item Actions, Select Add -> Not Using the Logical Volume Manager 7. Within Add CD_ROM Disk window, enter /SD_CDROM as Mount Directory: 8. In When to mount area, deselect Now. Leave At every system boot selected. 9. Click OK. 10. File -> Exit 11. File -> Exit SAM. Preparing the CD-ROM or DVD-ROM for Installation 1. In an HP terminal window, log on as the root user 2. Insert the Patch ABB-PHSU_241008 CD-ROM into the drive 3. Enter mount /SD_CDROM 4. Enter: /SD_CDROM/upgrade/register_depot This command only needs to be entered one time before loading the first station. It registers the directories containing the software to be loaded. Instructions for Station(s) to be Updated These instructions must be performed on each station that is to have the update installed. 1. If the station you are updating is an X-terminal host, do step a through step d before you go to step 2. If the station you are updating is not an X-terminal host, go directly to step 2. a. You need to stop the AdvaCommand software at every X-terminal connected to the host. Therefore, at each X-terminal running AdvaCommand remotely from the host, press <Ctrl-D> and enter stopsession in the command field. 3BUF001132D1 15

Instructions for Station(s) to be Updated Section 3 Installation b. On the X-terminal host station press <Ctrl-D> and enter quit in the command field. c. Suspend the AdvaCommand Auto Startup Interface by clicking on the Suspend button. d. On the X-terminal host, open an HP terminal window. 2. In an hpterm window, Log on as root (super user). 3. Shutdown the Advant Station and X server by entering: /sbin/init.d/advacommand stop This shuts down the Operator Station completely, and after a few seconds the X server will shut down. If a USB keyboard is directly connected to a PCI RTAB with USB port, a PS2 keyboard MUST be connected to proceed. 4. Once the X server is stopped you may have to press the <Enter> key to see the login prompt. 5. Log on as root (super user). 6. If you are loading from a.depot file, go to Step 7. If you are loading from CD-ROM, insert the Patch ABB-PHSU_241008 CD-ROM into the CD-ROM drive, then a. Load the patch by entering: /usr/sbin/swinstall -s <hostname>:/sd_cdrom <hostname> is hostname or IP address of Advant Station with CD-ROM drive attached. b. Go to Step 10. 7. Ensure that all volumes in /etc/fstab are mounted. To do this, compare the contents of the fstab file with the output of the bdf command. Comment out any volumes that are not mounted. 16 3BUF001132D1

Section 3 Installation Instructions for Station(s) to be Updated 8. Put the file you have received (ABB-PHSU_241008.depot) on the station where you are installing the patch, for example under the /tmp directory. 9. Enter: /usr/sbin/swinstall -s /tmp/abb-phsu_241008.depot This brings up the SD Install - Software Selection (station) window. If you get an error dialog indicating that The current session cannot be saved... Make sure that the HOME Environment variable is set, click OK to continue. This error may occur that this point, or later in the process. 10. Under the Actions menu select Match what Target Has. This will select the proper licensed options on your system to update (including History, and/or PDL and/or SPC). Ignore errors regarding fileset dependencies. Exit the dialog to continue the installation. 11. Under the Actions menu select Install (Analysis). 12. After analysis is complete, select the Logfile button to bring up the swagent.log file. Search for the correct date and time heading. Check for any messages that begin with ERROR or WARNING. When satisfied, select OK to exit the log file. 13. Select OK, then Yes to begin the installation. 14. When the installation has completed, again select the Logfile button to bring up the swagent.log file in the window. Search for the correct date and time heading. Check for messages that begin with ERROR or WARNING. When satisfied, select OK to exit the log file. Select DONE to finish the installation. 15. Under the File menu select Exit to end the swinstall process. 16. If you are loading from CD-ROM, remove the CD from the drive (see Finishing Instructions). 3BUF001132D1 17

Finishing Instructions Section 3 Installation 17. Enter the reboot command: reboot 18. At the Operator Station Startup Interface window, open HP terminal windows as required to complete Finishing Instructions on page 18. Exit all HP terminal windows when done. 19. Execute the swlist command in an HP terminal window to view the History version. Verify the version is 02.04.01.08, Figure 2. Verify History Version Figure 2. Verifying the History Version 20. Follow the start-up procedures as described in Advant Station 500 Series with AdvaCommand 1.9/1 / AdvaBuild 2.9/2 User s Guide. Finishing Instructions These instructions must be performed to remove the CD-ROM from the reader after loading the upgrade to the local station or remote stations. 1. In an HP terminal window, log on as the root user 2. Enter umount /SD_CDROM 3. Remove CD-ROM from the reader. Whenever an upgrade is installed on a system, you should check for ERROR in the following text files. Further checks can be reviewed the swinstall.log and swagent.log. 18 3BUF001132D1

Section 3 Installation Finishing Instructions Optional User Log At the end of the user_update.log file, add the upgrade names that you have installed, the date, and description if desired. Any other changes made to the product, such as custom memory pool changes may also be added. The file should be created it if it does not exist. You may make the file name more application specific, such as user_update_os1.9-1.log, and rename the file at each software update step along the way. The purpose of the text file is to prevent the deletion of certain user critical changes during a reloading or updating of a machine. 3BUF001132D1 19

Finishing Instructions Section 3 Installation 20 3BUF001132D1

3BUF001132D1 Litho in U.S.A. October 2004 Copyright 2002 by ABB. All Rights Reserved Registered Trademark of ABB. Trademark of ABB. http://www.abb.com/control Automation Technology Products Wickliffe, Ohio, USA www.abb.com/processautomation email: industrialitsolutions@us.abb.com Automation Technology Products Västerås, Sweden www.abb.com/processautomation email: processautomation@se.abb.com Automation Technology Products Mannheim, Germany www.abb.de/processautomation email: marketing.control-products@de.abb.com