Fieldbus Independent I/O Modules 4 DO DC 24 V 0.5 A, High-Side Switching (/xxx-xxx)

Similar documents
Fieldbus Independent I/O Modules 2 DI DC 24 V 3.0 ms, High-Side Switching (/xxx-xxx) Manual

Fieldbus Independent I/O Modules Field Side Connection Manual

Fieldbus Independent I/O Modules End Module (/xxx-xxx) Manual

Fieldbus Independent I/O Modules 24 V DC Power Supply/Fuse/Diagn Manual

Fieldbus Independent I/O Modules 4 AI DC 0-10 V, Single-Ended Manual

Fieldbus Independent I/O Modules 8 DI DC 24 V 3.0 ms, Manual

Fieldbus Independent I/O Modules 2 AO 4-20 ma Manual

Fieldbus Independent I/O Modules 4 AI Pt100/ RTD , (/xxx-xxx) Manual

Fieldbus Independent I/O Modules 2 AI 4-20 ma, Single-Ended Manual

Fieldbus Independent I/O Modules SSI Transmitter Interface Manual

Fieldbus Independent I/O Modules 1 AI DMS Manual

Fieldbus Independent I/O Modules Bluetooth RF Transceiver Quick Start

Fieldbus Independent I/O Modules Serial Interface RS 232 C (/xxx-xxx) Manual

WAGO Remote IO with Fanuc Robot using EtherNet/IP Protocol Application note

Redundant ethernet communication with WAGO Ethernet-Controller Application note

Using WAGO Series 750 DeviceNet IO with an A-B ControlLogix 1756-DNB Scanner Application note

Using WAGO Series 750 DeviceNet IO with an A-B SLC SDN Scanner Application note

Using the WAGO as Remote I/O with an Omron SYSMAC CJ2 Series PLC. Application note. A116700, English Version 1.1.0

Manual Version WAGO TO-PASS 761. Telecontrol Modules. 761-xxx. System Description

Using the WAGO as Remote I/O with a ControlLogix Ethernet/IP Bridge Module Application note

Application Note. Building. Automation WAGO-I/O-PRO V2.3. openvpn with Linux based Devices A500880_en. Version 1.1.1

Using WAGO Series 750 EtherCAT coupler with CoDeSys SP Win V3 Application note

Configuring National Instruments Lab View with WAGO I/O Application note

Manual. WAGO-I/O-SYSTEM DI 24VDC 3.0ms Channel Digital Input Module 24 V DC, High-side switching. Version 1.1.0

WAGO-I/O-SYSTEM 750 2DI 24V DC VDC,

Library for Building Automation. Module Descriptions for KNX IP Master

Application Note. WAGO-I/O-SYSTEM 750 Connecting energy meters with M-Bus interface to the WAGO-I/O-SYSTEM

Application note. WAGO-I/O-SYSTEM 750 DALI Multi-Master Module Configuration of a DALI Lighting System via WAGO- I/O-PRO V2.

Fieldbus Independent I/O Modules Incremental Encoder Interface Manual

Safety I/O Modules PROFIsafe 4FDO 0,5A/4FDI 24V DC PROFIsafe / Manual

Using the WagoAppEtherNetIP_Adapter library with a CompactLogix Controller A500930

Port 100Base-TX Industrial Eco Switch

The HART Module on the WAGO ETHERNET Controller Application Note

Application Note. a HART Tool-routing with Emerson AMS HART over TH LINK PROFIBUS for Asset Management 1.0.0

WAGO-I/O-SYSTEM 750 CODESYS-2-Library WagoLibWakeOnLan.lib Wake on lan Remote wake up of network devices

Application Note. Connection of an WAGO ETHERNET Coupler/Controller to a S controller

Manual / Electronic Circuit Breaker DC 24 V, A. Version 1.0.0

Quick Install Manual BACnet /IP Controller

Library Description. DALI_647_SpecialSensor_02.lib Specific Sensor Solutions. Version 1.0.1

Fieldbus Independent I/O Modules DALI/DSI Master Module Manual

Application Note. Enable port forwarding for PFC. A500840, English Version 1.0.0

DeviceNet TM Fieldbus Coupler 125 Kbaud Kbaud; digital and analog signals

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Libraries for Building Automation. Function Blocks and Data Types for the BACnet Controller

M-BUS MASTER OEM MODULE MBUS-M13

Manual. WAGO-I/O-SYSTEM 750 CANopen ECO Fieldbus Coupler MCS kbaud... 1 MBaud; digital and analog signals 2.0.0

Using PROFIsafe modules in combination with PROFIBUS-DP and PROFINET Application note

Channel Digital Input Module 24 V DC High-side switching

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

Modular I/O System. DeviceNet

Modular I/O-System ETHERNET TCP/IP

Modular I/O-System ETHERNET TCP/IP

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

Libraries for Building Automation. Module Descriptions for the WINSTA Sunblind Box /

Modular I/O System. DeviceNet ,

Modular I/O System LONWORKS ,

AI561 Analog Input Module

Library for Building Automation

Manual. WAGO-I/O-SYSTEM 750 Programmable Fieldbus Controller ETHERNET /100 Mbit/s; digital and analog signals. Version 1.1.

Library for Building Automation. Function block descriptions for time- switching functions

Redundancy unit CP-A RU

DX561 Digital Input/Output Module

PROFIsafe modules V2 ipar 75x-66x/ WAGO Safety-Editor-75x Quickstart

Documentation KM2002, KM2004, KM2008. Terminal modules with digital outputs, 24 V, 0.5 A. Version: Date:

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Library Description. MBUS_649_01.lib WAGO M-Bus Library. Version 1.0.1

DC562, digital input/output module,

CPCI-PS24 24V-Power Supply

DC561, digital input/output module,

Documentation. KM10xx. Terminal Modules with Digital Inputs. Version: Date:

Operating instructions. Standstill monitor A / / 2011

Modular I/O-System KNX IP Controller

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

WagoLib_CAN_Gateway_02.lib

AO561 Analog Output Module

PHOENIX CONTACT - 12/2007

STEP-PS/1AC/24DC/2.5. Extract from the online catalog. Order No.: DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase.

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Using power measurement module with TIA A500671

Libraries for Building Automation. Function Block Description for DALI Multi-Master Module

TU531, TU532 Terminal Unit

PI-EX-ME-2NAM/COC-120VAC

PHOENIX CONTACT - 07/2006

Siemens Industrial s

PI-EX-ME-2NAM/COC-24VDC

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

AO523 Analog Input Module

DI572 Digital Input Module

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

WAGO-I/O-SYSTEM 750 IO-Link Master

CU port USB 2.0 hub. Version: 1.1 Date:

MINI MCR-SL-UI-2I(-SP)(-NC)

DI561 Digital Input Module

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Modular I/O-System. Fieldbus Coupler PROFINET IO

Operating instructions. Switching amplifier DN0210 DN / / 2015

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

TF501, TF521 Terminal Bases

Power Supply HARTING pcon

Transcription:

Fieldbus Independent 4 DO DC 24 V 0.5 A, High-Side Switching 750-504(/xxx-xxx) Manual Version 1.0.5

ii General Copyright 2006 by WAGO Kontakttechnik GmbH & Co. KG All rights reserved. WAGO Kontakttechnik GmbH & Co. KG Hansastraße 27 D-32423 Minden Phone: +49 (0) 571/8 87 0 Fax: +49 (0) 571/8 87 1 69 E-Mail: info@wago.com Web: http://www.wago.com Technical Support Phone: +49 (0) 571/8 87 5 55 Fax: +49 (0) 571/8 87 85 55 E-Mail: support@wago.com Every conceivable measure has been taken to ensure the correctness and completeness of this documentation. However, as errors can never be fully excluded, we would appreciate any information or ideas at any time. E-Mail: documentation@wago.com We wish to point out that the software and hardware terms as well as the trademarks of companies used and/or mentioned in the present manual are generally trademark or patent protected.

Content iii Content 1 Important Comments...4 1.1 Legal Principles...4 1.1.1 Copyright...4 1.1.2 Personnel Qualification...4 1.1.3 Intended Use...4 1.2 Symbols...5 1.3 Number Notation...5 1.4 Safety Notes...6 1.5 Scope...6 2...7 2.1 Digital Output Module...7 2.1.1 750-504(/xxx-xxx) [4 DO DC 24 V 0.5 A, High-Side Switching]...7 2.1.1.1 Variations...7 2.1.1.2 View...7 2.1.1.3 Description...8 2.1.1.4 Display Elements...9 2.1.1.5 Schematic Diagram...9 2.1.1.6 Technical Data...10 2.1.1.7 Process Image...11

4 Important Comments Legal Principles 1 Important Comments 1.1 Legal Principles 1.1.1 Copyright To ensure fast installation and start-up of the units described in this manual, we strongly recommend that the following information and explanations are carefully read and abided by. This manual is copyrighted, together with all figures and illustrations contained therein. Any use of this manual which infringes the copyright provisions stipulated herein, is not permitted. Reproduction, translation and electronic and photo-technical archiving and amendments require the written consent of WAGO Kontakttechnik GmbH & Co. KG. Non-observance will entail the right of claims for damages. WAGO Kontakttechnik GmbH & Co. KG reserves the right to perform modifications allowed by technical progress. In case of grant of a patent or legal protection of utility patents all rights are reserved by WAGO Kontakttechnik GmbH & Co. KG. Products of other manufacturers are always named without referring to patent rights. The existence of such rights can therefore not be ruled out. 1.1.2 Personnel Qualification 1.1.3 Intended Use The use of the product detailed in this manual is exclusively geared to specialists having qualifications in PLC programming, electrical specialists or persons instructed by electrical specialists who are also familiar with the valid standards. WAGO Kontakttechnik GmbH & Co. KG declines all liability resulting from improper action and damage to WAGO products and third party products due to non-observance of the information contained in this manual. For each individual application, the components supplied are to work with a dedicated hardware and software configuration. Modifications are only permitted within the framework of the possibilities documented in the manuals. All other changes to the hardware and/or software and the nonconforming use of the components entail the exclusion of liability on part of WAGO Kontakttechnik GmbH & Co. KG. Please direct any requirements pertaining to a modified and/or new hardware or software configuration directly to WAGO Kontakttechnik GmbH & Co. KG.

Important Comments 5 Symbols 1.2 Symbols Danger Always abide by this information to protect persons from injury. Warning Always abide by this information to prevent damage to the device. Attention Marginal conditions must always be observed to ensure smooth operation. ESD (Electrostatic Discharge) Warning of damage to the components by electrostatic discharge. Observe the precautionary measure for handling components at risk. Note Routines or advice for efficient use of the device and software optimization. More information References on additional literature, manuals, data sheets and internet pages. 1.3 Number Notation Number Code Example Note Decimal 100 normal notation Hexadecimal 0x64 C notation Binary '100' '0110.0100' within inverted commas, nibble separated with dots

6 Important Comments Safety Notes 1.4 Safety Notes Warning Switch off the system prior to working on bus modules! In the event of deformed contacts, the module in question is to be replaced, as its functionality can no longer be ensured on a long-term basis. The components are not resistant against materials having seeping and insulating properties. Belonging to this group of materials is: e.g. aerosols, silicones, triglycerides (found in some hand creams). If it cannot be ruled out that these materials appear in the component environment, then additional measures are to be taken: - installation of the components into an appropriate enclosure - handling of the components only with clean tools and materials. Attention Cleaning of soiled contacts may only be done with ethyl alcohol and leather cloths. Thereby, the ESD information is to be regarded. Do not use any contact spray. The spray may impair the functioning of the contact area. The and its components are an open system. It must only be assembled in housings, cabinets or in electrical operation rooms. Access must only be given via a key or tool to authorized qualified personnel. The relevant valid and applicable standards and guidelines concerning the installation of switch boxes are to be observed. ESD (Electrostatic Discharge) The modules are equipped with electronic components that may be destroyed by electrostatic discharge. When handling the modules, ensure that the environment (persons, workplace and packing) is well grounded. Avoid touching conductive components, e.g. gold contacts. 1.5 Scope This manual describes the Digital Output Module 750-504(/xxx-xxx) 4 DO DC 24 V 0.5 A, High-Side Switching of the modular WAGO-I/O- SYSTEM 750. Handling, assembly and start-up are described in the manual of the Fieldbus Coupler. Therefore this documentation is valid only in the connection with the appropriate manual.

750-504(/xxx-xxx) [4 DO DC 24 V 0.5 A, High-Side Switching] 7 Variations 2 2.1 Digital Output Module 2.1.1 750-504(/xxx-xxx) [4 DO DC 24 V 0.5 A, High-Side Switching] 2.1.1.1 Variations 4-Channel Digital Output Module DC 24 V 0.5 A, short-circuit-protected, high-side switching Item-No. Designation Description 750-504 4 DO DC 24 V 0.5 A High-Side Switching 750-504/025-000 4 DO DC 24 V 0.5 A, High-Side Switching /T 4-Channel Digital Output Module DC 24 V 0.5 A, short-circuit-protected, high-side switching 4-Channel Digital Output Module DC 24 V 0.5 A,short-circuit-protected, high-side switching extended temperature range from 20 C to +60 C 2.1.1.2 View Status DO 1 DO 3 DO 1 A B 13 14 13 14 + + C D Status DO 2 DO 4 Data contacts DO 2 - - 24V 0V 15 16 DO 3 DO 4 750-504 Power jumper contacts Fig. 2.1.1-1: 4-Channel Digital Output Module 750-504 g050400e I/OModules

8 750-504(/xxx-xxx) [4 DO DC 24 V 0.5 A, High-Side Switching] Description 2.1.1.3 Description The connected load is switched via the digital output from the control system. The module has four output channels. Two actuators may be directly connected to the module. As an example, two 2-conductor actuators may be directly connected using connection 0 V and signal output DO 1 or 0 V and signal output DO 2. The connection of more actuators to signal outputs DO 3 and DO 4 requires a field side connection module (750-614) for 24V and for 0V, if need be. Note For the connection of inductive loads a protected circuit, e. g. a recovery diode, has to be switched parallel to this load. The output channels are electrically short-circuit-protected and high-side switching. Which means that the status of the output channels is "high" if the output channels switch to the 24 V supply voltage for the field side. The supply voltage for the field side is derived from an adjacent supply module by means of power jumper contacts. The status of the four output channels is indicated via green status LEDs. An optocoupler is used for electrical isolation between the bus and the field side. Any configuration of the output modules is possible when designing the fieldbus node. Grouping of module types is not necessary. The field side supply voltage of 24 V for the output module is derived from adjacent I/O modules or from a supply module. The supply voltage for the field side is made automatically through the individual I/O modules by means of power jumper contacts. Warning The maximum current of the internal power jumper contacts is 10 A. When configuring the system it is important not to exceed the maximum/sum current. However, if such a case should occur, another supply module must be added. Attention In case of overloads a supply module with fuse (750-601) must be connected on the line side to protect the output modules! The output module 750-504 can be used with all couplers/controllers of the.

750-504(/xxx-xxx) [4 DO DC 24 V 0.5 A, High-Side Switching] 9 Display Elements 2.1.1.4 Display Elements A B A B 13 14 C D Fig. 2.1.1-2: Display Elements g050402x C D LED Channel Designation State Function A green C green B green D green 1 Status DO 1 2 Status DO 2 3 Status DO 3 4 Status DO 4 off on off on off on off on Output DO 1: not active Output DO 1: active Output DO 2: not active Output DO 2: active Output DO 3: not active Output DO 3: active Output DO 4: not active Output DO 4: active 2.1.1.5 Schematic Diagram DO 1 1 5 DO 2 DO 270pF 24V 2 6 24V 3 7 10nF 10nF DO 0V 0V 10nF DO 3 4 8 DO 4 750-504 Fig. 2.1.1-3: 4-Channel Digital Output Module 750-504 g050401e I/OModules

10 750-504(/xxx-xxx) [4 DO DC 24 V 0.5 A, High-Side Switching] Technical Data 2.1.1.6 Technical Data Module Specific Data Number of outputs 4 Current consumption (internal) max. 7 ma Voltage via power jumper contacts DC 24 V (-15 % / + 20 %) Type of load Switching rate max. Reverse voltage protection Output current Energy dissipation W max. (unique switching off) Isolation Current consumption typ. (field side) Internal bit width resistive, inductive, lamps 1 khz yes 0.5 A short-circuit-protected 0.3 J L max. = 2 W max. /I² 500 V (System/Field) 30 ma (per module) + load 4 Bit out Dimensions (mm) W x H x L 12 x 64* x 100 * from upper edge of 35 DIN rail Weight ca. 50 g Standards and Regulations (cf. Chapter 2.2 of the Coupler/Controller Manual) EMC-Immunity to interference (CE) acc. to EN 61000-6-2 (01) EMC-Emission of interference (CE) acc. to EN 61000-6-3 (01) EMC-Immunity to interference (Ship building) acc. to Germanischer Lloyd (01) EMC-Emission of interference (Ship building) acc. to Germanischer Lloyd (01) Approvals (cf. Chapter 2.2 of the Coupler/Controller Manual) CUL US (UL508) ABS (American Bureau of Shipping) BV (Bureau Veritas) DNV (Det Norske Veritas) GL (Germanischer Lloyd) Cl. B Cat. A, B, C, D KR (Korean Register of Shipping) LR (Lloyd's Register) Env. 1, 2, 3, 4 NKK (Nippon Kaiji Kyokai) RINA (Registro Italiano Navale) CUL US (UL1604) KEMA Class I Div2 ABCD T4A II 3 G EEx na II T4 Conformity Marking

750-504(/xxx-xxx) [4 DO DC 24 V 0.5 A, High-Side Switching] 11 Process Image More Information Detailed references to the approvals are listed in the document "Overview Approvals ", which you can find on the CD ROM ELECTRONICC Tools and Docs (Item-No.: 0888-0412) or in the internet under: www.wago.com! Documentation!! System Description 2.1.1.7 Process Image Output bit B3 B2 B1 B0 Meaning controls DO 4 Channel 4 controls DO 3 Channel 3 controls DO 2 Channel 2 controls DO 1 Channel 1 I/OModules

WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 D-32385 Minden Hansastraße 27 D-32423 Minden Phone: 05 71/8 87 0 Fax: 05 71/8 87 1 69 E-Mail: info@wago.com Internet: http://www.wago.com