SM100. On-Line Switchgear Condition Monitoring

Similar documents
Bus Bar Protection Relay B-PRO 4000

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT66

Circuit Breaker Analyzer & Timer CAT65

Scout-S Station Controller

Comprehensive next generation breaker condition monitor

TWFL - Travelling Wave Fault Location System

Transformer Protection Relay

Circuit Breaker Analyzer & Timer CAT126

MINER-S Station Controller

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

TFS 2100 Traveling Wave Fault Location System

Circuit Breaker Sentinel (CBS) for SF 6. power circuit breakers

Protection Relays PHASE & RESIDUAL OVERCURRENT

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

CBA 1000 Circuit Breaker Analyzer and MicroOhmmeter

Communication Gateway COM 610. Product Guide

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

FP-5000 Feeder Protection

VCL-TP, Teleprotection Equipment

APP 700 Technical Specification

FL MC 2000E (SM40) LC

IDM DATA ACQUISITION SYSTEM

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test:

Testing Instruments Manufactured by

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

CBA 1000 CHARACTERISTICS

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

Control Panel CP600-eCo CP604, CP604-B

Reyrolle Protection Devices. 7SG117 Argus 7 Synchronising Relay. Answers for energy

Circuit Breaker Analyzer & Timer CAT-P

A P P L I C A T I O N

Technical specification Marine Master Clock

Feeder/ Motor Protection Relay VAMP 40

Control Panel CP600 CP651, CP651-WEB

PMC 530 Series Advanced Multifunction Meter

CT-8000 S3. digital circuit breaker analyzer

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

CAT I series Circuit Breaker Analyzers & Timers

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this

TU531, TU532 Terminal Unit

ENhanced TEChnology. Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

Electronic timer CT-AHD.22

Control Panel CP600 CP635, CP635-B, CP635-WEB

CBA HV Circuit Breaker Analyzer and Microhmmeter

CT-7500 S2. Advanced Test Equipment Rentals ATEC (2832) digital circuit breaker analyzer

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

QUALITROL QTMS Transformer Monitoring System

TECHNICAL DESCRIPTION

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

Circuit Breaker Analyzer & Timer CAT-P

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

INGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016

DRTS 33. The new generation of advanced three phase relay test set

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

Series MV2000 MEDIUM VOLTAGE HIGH CURRENT POWER SUPPLIES

MINER-S Station Controller. Substation Automation

Arc protection relay. Features Three-phase overcurrent function. Application

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

FP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay

CT-8000 S3 digital circuit breaker analyzer

CAT I series Circuit Breaker Analyzers & Timers

SPM91 DIN Rail Single Phase Energy Meter Installation & Operation Manual V1.0

DI572 Digital Input Module

CT-6500 S2. digital circuit breaker analyzer. Vanguard Instruments Company, Inc.

NewCode. Comprehensive Motor Protection and Control Relay. Relay Field Input and Output LEDs. LED Fault Indicators

Earth-fault Relay SPAJ 110 C. Product Guide

Table 1 Relay Model and Function

For Transmission, Distribution and Machinery protection.

MIC-2 MKII, Multi-instrument DATA SHEET

RT4F-110V/25A RECTIFIER

Residual overvoltage relay

4 channel PD tester for semiconductor test TPP

Power System Monitoring Recorder TESLA 3000

extending the boundaries of technology evolution of proven technology FEATURES

Reyrolle Protection Devices. 7SG21 DDB20 Multi Range Digital Setting Time Delay Relay. Energy Management

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

ATU800. Technical specification

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

Relion 611 series. 611 series Type Test Certificate

TM221CE40T controller M IO transistor PNP Ethernet

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

NPW800R RETROFITTING. Power and Volatge Protection Relay

GRD130 - FEATURES APPLICATION

3156 LEAK CURRENT HiTESTER

Electronic timer CT-ERD.12

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Wall-/Pipe Mounted Universal Process Indicator

BITRONICS 878 DIOD Product Description BITRONICS 878 DIOD DISTRIBUTED INPUT/OUTPUT DEVICE

3500/23E Transient Data Interface

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

Transcription:

On-Line Switchgear Condition Monitoring

On-Line Switchgear Condition Monitoring Introduction Weis is a specialist company with over 40 years of experience in the commissioning, testing & maintenance of switchgear and power network fault monitoring within the Power Utility Industry. Based on its pioneering of analogue timing techniques developed over more recent years, Weis has applied its expertise to develop a low cost permanently installed switchgear condition monitoring system. The On-Line Switchgear Condition Monitoring System () is an essential substation preventative maintenance tool and aid for power utilities with ever increasing demands for more reliable low cost energy. Possible on-line test results which can be computed per phase for each breaker operation include: Feature Extraction - Peak Coil Current - Coil Current Pulse Length - Mechanism Time - Arc Duration Time - Pre Latch Period - Latch Transition - Trip Latch Release Coil Current Fingerprint Comparison / Grey Zone Checking Accumulated Contact Wear (I n T) Accumulated Contact Operation Count Estimated Main Contact Operated Time Mechanism Motion Battery Voltage The can optionally perform trend recording for: Gas / Pressure Leakage Heater Failure Low Pressure RMS Current per Phase RMS Voltage per Phase Battery Voltage In addition the can optionally perform a Off-Line timing test on the main contacts. This system is the first step towards on-time maintenance that should be supported with Off-Line dynamic microohm testing / timing, to gain more in-depth knowledge and experience. Features Mount within Breaker Drive Unit, external enclosure or indoor Non-Invasive Installation Simple-to-Service Design Capture signature of each breaker operation with option for time tagging to within 1 Sec. Local or Remote Indication of Switchgear Condition Off-Line Timing of Main Contacts Optional Trend Recording Optional Power Quality Measurements Optional Central Database Management Software for Analysis and Performance Monitoring of Switchgear Network

Connections Non-Invasive Hall Effect Transducer Wetted Externally or Internally (Off-Line) Split Core CT (Secondary) 1 x Trip / Close Coil Currents 4 x User Defined Contacts 3 x Phase Current * Direct Connection Transformer Secondary Slide Wire Travel Transducer 2-Wire Tx (24VDC Loop Powered) 1 x Battery Voltage * 3 x Phase Voltage * 3 x Motion * 6 x Pressure / Temperature * Swicthgear Monitor Non Synchronous Wetted Externally or Internally (Off-Line) 8 x User Defined Analogue * 4 x User Defined Contacts * * Optional RS485 RS232 Multi-Drop Substation Communications to Local Processing Unit or Local / Remote (via Modem) Communications to PC Multi-Drop Substation Communications from Units (100 max.) RS485 Split Core CT (Secondary) 4 x Phase Current * Backlight LCD Display Keypad Operator Interface for Local Network Local Transformer Secondary 4 x Phase Voltage * Processing Unit Status LED s Local Diagnostic Indication Direct Connection 1 x Battery Voltage * Alarm Contacts Alarm or SCADA system Time Synchronisation * GPS or DCF77 * Optional Ethernet RS232 Local or Remote (via Modem) Communication to PC or SCADA

On-Line Switchgear Condition Monitoring Data Management Switchgear Management System software is an essential Windows database program for the gathering of information on the network for switchgear performance monitoring and maintenance scheduling. Possible Features:- Automatic analysis / classification of breaker operation records Checks protection operation timing Simple network overview Exports measurement to Voltage Dips and Breaker Performance databases Graphical display of captured waveforms Graphical display of trend recording data The Switchgear Management System runs on a standard IBM compatible PC and would normally be set to auto-poll and / or autocall modes for data gathering. A graphing function which allows the user to view breaker operation signatures and trend recording data. This system is the first step towards on-time maintenance that should be supported with Off- Line dynamic micro-ohm testing / timing, to gain more in-depth knowledge and experience. With this in mind, raw sample data is stored for future reference to allow recalculation based on alternative parameters. The system also includes a configuration program that allow local or remote modification of units direct or via a Local Processing Unit. Dependant upon measured signals at the units, the following resultant information can be gathered :- Switchgear Performance Contact Condition Voltage Dips Power Quality / Trend Digital Signal Processing techniques are used to compare coil current pulses and travel curves (optional) with reference waveforms.

Typical System Substation #1 Switchgear Monitor RS232 Modem Substation #... Switchgear Monitor RS485 RS485 Switchgear Monitor #1 #... T e l e p h o n e E x c h a n g e Switchgear Management System Local Processing Unit RS232 Modem

On-Line Switchgear Condition Monitoring Specifications INPUTS Analogue: Analogue Accuracy: <0.25% F.S. Digital: Digital Resolution: OUTPUTS 1 x Trip and close coil current inputs. 1 x Battery voltage 300V DC maximum Optional 3 x Phase current (via secondary level split core CT) - Optional 3 x Phase voltage (VT secondary level) - Optional 3 x Resistive (linear or rotary) travel transducer inputs Optional 6 x Pressure / Temperature (via 2-wire 24V DC loop powered transmitter) Optional 8 x User configurable non-synchronous inputs Optional 4 x User configurable 24 to 250V DC externally wetted or 24V DC internally wetted (off-line) inputs for contact timing. 4 x User configurable 24 to 250V DC externally wetted or 24V DC internally wetted (off-line) inputs for contact timing Optional 100µSec. Alarm Output: 2 x relay contacts for watchdog and circuit breaker condition (definable). COMMUNICATIONS Communication: RS232 for local / remote (via modem) communication to PC or RS485 (multi-drop) substation communications to Local Processing Unit. RECORDING Resolution: 12 bit A/D (1:4096) Sampling Rate: 10, 5, 2, 1 khz (user selectable). Real Time Clock: Free running crystal clock with option to time synchronise via autopoll from PC to within 1 second or via LPU to within 1mS between substations for time stamping of records. Storage: 2 records minimum (actual depends on selected sample rate). Start trigger: Digital input, coil current, over phase current or under phase voltage. OPERATING VOLTAGES Prime Power: 24 / 48 / 110 / 220V DC. ENVIRONMENTAL Operating Temperature: Humidity: Isolation: Surge Withstand Transient: -30ºC to 60ºC (-22ºF to 140ºF) 0 to 97% RH non-condensing. 2.5kV rms for 1 minute (channel to channel, channel to earth) To IEC 801-5. 1.2/50μS. Common Mode: Severity level class 4. Series Mode: Severity level class 3. Fast Transient Burst: To IEC 801-4 level 3. RFI Immunity: To IEC801-3 level 3. 10V/m 26-1000MHz. Emissions: To EN50081-1: 1992. MECHANICAL DETAILS Mounting: Within breaker drive unit, external or indoor enclosure.

Specifications LPU INPUTS Analogue: OUTPUTS Alarm Output: 1 x Battery voltage 300V DC maximum Optional 4 x phase current (via secondary level split core CT) - Optional 4 x phase voltage (VT secondary level) - Optional 4 x relay contacts ( failure, LPU failure, set contact wear limit reached and data logging parameter outside limites). COMMUNICATIONS Communication: USER INTERFACE Input: Output: Configuration: Indication: RECORDING RS232 for local / remote (via modem) communication to PC and RS485 (multi-drop) substation communications to Units (100 max.). Keypad. Backlight alpha-numeric LCD display. Diagnostic LED s. Configuration of all connected units and Processing Unit. Status of any monitored breaker on LCD display. Resolution: 12 bit A/D (1:4096) Sampling Rate: 10 khz. Trend Recording: 1 minute min, max & avg on all analogue channel. Storage: Hard disk drive for mass data from connected units. Real Time Clock: Free running crystal clock with option to time synchronise via autopoll from PC to allow time stamping of records / trend data to within 1 second between substations. GPS or RCC: Optional. GPS accuracy <1mS, DCF77 <10mS. OPERATING VOLTAGES Prime Power: ENVIRONMENTAL Operating Temperature: Humidity: Isolation: Surge Withstand Transient: 88 to 370V DC, 85 to 264V AC. -10ºC to 55ºC (14ºF to 131ºF) 0 to 97% RH non-condensing. 2.5kV rms for 1 minute (channel to channel or channel to earth) To IEC 801-5. 1.2/50μS. Common Mode: Severity level class 4. Series Mode: Severity level class 3. Fast Transient Burst: To IEC 801-4 level 3. RFI Immunity: To IEC801-3 level 3. 10V/m 26-1000MHz. Emissions: To EN50081-1: 1992. MECHANICAL DETAILS Mounting: Surface or 19 wide rack. DUE TO CONTINUING DEVELOPMENT AND IMPROVEMENTS WEIS RESERVES THE RIGHT TO CHANGE THIS SPECIFICATION WITHOUT NOTICE Windows is a trademark for Microsoft Inc.

Head Office Weis GmbH & Co. KG Kaffeestrasse 4 28779 Bremen Germany Tel: +49 (0) 421 606040 Fax: +49 (0) 421 607066 Email: WeisGmbHBremen@t-online.de COPYRIGHT 2008 WEIS Room 506, Building 7, No.59, Shennan Road Taihong R&D Office Part, Minhang District Shanghai China 201108 Tel / Fax: +86 (0) 21 34635190 Email: xuehua.lu@hotmail.com www.weisgmbh.com UK Office WEIS GmbH & Co. KG Bay Trees 47 Beltinge Road Herne Bay Kent CT6 6DA UK Tel: +44 (0) 1227 749413 Email: sales@weisgmbh.com PRODUCT BULLETIN REV 7