Products no longer available

Similar documents
Technical data. Safety notes. Product features

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

Functional data Factory settings Variable Setting Torque Inhibiting torque

Non-communicating room controllers

ZN230-24MP-1 MP-BUS

s Spring return C / max C

Belimo Gateway MP to Modbus RTU - UK24MOD

Technical data sheets

Overview of types. Technical data

Power consumption In operation At rest For wire sizing

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Belimo Gateway MP to Modbus RTU - UK24MOD

Brief description. Type overview

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Products no longer available

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data sheet

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

TAC I/NETTM 1284, 1280, Security Control Unit

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Technical data sheet. Technical data

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

Non-communicating room controllers

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Technical Manual Nova: Cabinet Security Management System (CSMS)

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Temperature controller Ducted systems

COMTRAXX COM460IP. BMS-Ethernet-Gateway

Products no longer available

Control engineering information VARYCONTROL VAV Units VAV Compact flow rate controller BC0 BF0

MCX08M2 Programmable controller

EXOcompact. Third generation freely programmable controllers

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Products no longer available

Brief description. Type overview

VAV system solution for non-pressure dependent applications in enclosed spaces

EC700. Pulses concentrator. User instructions

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

Supplementary operating instructions for your air curtain system Controller TMC 500

IQ-MP Gateway. Version apr Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel :

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

ECL Comfort V a.c. and 24 V a.c.

ISOMETER isoev425 with coupling device AGH420

Technical data. PRCA-BAC-S2-T en-gb subject to changes 1

BMS-Ethernet-Gateway COM460IP

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

COUNTIS Ci Notice d utilisation GB Operating instructions Bedienungsanleitung NL Gebruiksaanwijzing

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

DTM Distributed Transmitter Monitor

THERMOSTATS & CONTROLLERS

I/O module, universal, digital, S0 inputs, modu533

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Programmable controller MCX06C

Installation and User Guide

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs

Decentralised operating and monitoring systems

General information. Display. Supply voltage. Input current. Encoder supply. Output current

ADVANCED OPERATOR PANEL (AOP)

Buffered Power Supply PS-30DR v1.0

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Access Terminal IF-800

Vgraph Hardware manual ver Code 114VGRAHWE01. Vgraph CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY ENGLISH. HARDWARE MANUAL ver. 1.

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

MIC-2 MKII, Multi-instrument DATA SHEET

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

H704-42(H)(E), H704-42/1(H)(E)

EXOcompact. Freely programmable controller

Installation and Operation Back-UPS Pro 900

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

General information. Display. Supply voltage

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.

Sauter Systems

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

Power supply module, bus connection module

100% electricity. Automatic transfer switch controllers ATL series

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

I/O module, digital and universal inputs, modu530

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

SK TU4-CAO-C Part number:

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

BMR Operating Instructions

AC5160 SiPass integrated controller kit

ISOMETER isopv with coupling device AGH-PV

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Installing VO2 Analog Output Boards

Transcription:

Technical data sheet BKS24-.. MONICO-Controller BKS24-.. Forms an efficient fire protection system together with the motorisation sets BF(G)24MP Controller with application software for control and monitoring of fire dampers via MP-Bus. As stand-alone or master/slave configuration Technical data Electrical data Supply voltage 24 VAC ±15%, 50/60 Hz or 20 60 VDC Connection Terminal strips, max. 250 VAC Cable diameter 0.5 2.5 mm 2 A 24 V transformer with protection class II and at least 25 VA (per controller) should be used for AC operation. The supply line to the controller must be protected by a 250 V/1 A slow-blow fuse. Bus connection MP-Bus 2-wire, conductor length up to 800 m @ 0.75 mm 2 Connection of up to 8 Top Line fire protection actuators Inputs/outputs Digital inputs Connection of floating contacts from the fire alarm and ventilation system. Supply from controller, 6 ma Digital outputs 2 relay outputs for fan release and transmission of the fault report. Switching capacity 250 VAC, 2 A Safety Protection class For integration in class I or II devices. Degree of protection IP65 EMC CE according to 89/336/EEC Mode of operation Type 1 (acc. to EN 60730-1) Ambient temperature range 10... +60 C Non-operating temperature range 20... +70 C Ambient humidity range 5... 95% RH, non-condensating (EN 60730-1) Maintenance Maintenance-free Dimensions/weight Dimensions 420 x 314 x 143 mm (H x W x D), for mounting on DIN rails Weight approx. 4.8 kg Safety notes! The MONICO system solution is not allowed to be used outside the specified field of application, especially in aircraft or in any other airborne means of transport. Only components explicitly approved for this purpose by Belimo are allowed to be used for the MONICO system solution. The network may only be configured, and the system configuration changed, by suitably trained and authorised personnel! Check the relevant standards and national directives prior to planning the system. Consult a fire protection expert if necessary. www.belimo.com 1

BKS24-.. Controller for fire dampers System configuration Electrical installation Controller BKS24-.. Motorisation sets BF(G)24MP External operating panel Z-PKT0FSW210 Mechanical installation Controller mounting Master/slave controller connection (BKS24-1M, BKS24-1S) After the fire dampers have been connected via the MP-Bus, the digital inputs/outputs and possibly further slave stations have been connected and the supply voltage has been applied, the MONICO-.. fire protection system is ready for parameterisation and commissioning. The master controller has a display and a system clock, while the slave controller has neither a display nor a clock. The motorisation sets (BF24MP and BFG24MP) consist of a communications-capable fire protection actuator of the Top Line series with an integrated thermoelectrical tripping device and a communication and power supply unit for connection to the MP-Bus network. These motorisation sets are only provided to fire damper manufacturers! The optionally available operating panel Z-PKT0FSW210 allows the MONICO-.. fire protection system to be decentrally controlled and operated. The operating panel is connected to the plan bus of the controller. The controller is mounted on DIN rails. J5 J6 J8 J9 J10 J11 J1 J2 J3 J4 2 www.belimo.com

Controller for fire dampers BKS24-.. Electrical installation Wiring diagram Master Wiring diagram Slave plan connection J6 J1 G G0 J4 ID1 ID2 IDC1 J6 J1 + + plan J8 BKS24-1M 24 VAC 20/60 VDC plan J8 BKS24-1S G G0 24 VAC 20/60 VDC Slave controller connection 2-wire MP-Bus Relay outputs (BF(G)24MP set) Fan release Fault MP GND J10 C4 NO4 J11 NO5 C5 Master controller connection 2-wire MP-Bus (BF(G)24MP set) MP GND Fire alarm system Digital inputs Ventilation system + 24 VAC 20/60 VDC + 24 VAC 20/60 VDC + 24 VAC 20/60 VDC Cable: 2 x 2 wires twisted (0.5 mm 2 ) shielded Please note: Observe the network polarity! Connect each RX/TX+ to RX/TX+ on the other controller; the same applies for the RX/TX connections. The cable shield must always be connected to the «G» connection. www.belimo.com 3

BKS24-.. Controller for fire dampers Electrical installation User interface Connection of fire damper to MP-Bus Operation of the controller Operating panel on master station No. / key Function 1 LCD infos 2 and reset faults 3 Prg Open navigation menus 4 Esc To overview / back 5 Scroll down 6 Scroll up 7 Confirm entry MP GND AC 230 V MP BUS TECHNOLOGY BY BELIMO MP GND M 24 V LED 1 2 3 4 5 6 7 24 V Ya Optional smoke detector contact (floating) PC Tool BKN230-24MP BF(G)24TL-T-ST BF(G)24MP set Master operating panel The master controller has an operating panel, consisting of an LCD display and a keyboard with 6 keys. 1 2 3 4 Prg Esc 5 6 7 Key combinations on master Key combinations for external operating panel Software information display + (> 3 s) Software information display / (> 10 s) Call up addressing functions + + Connect supply voltage Set display contrast + Prg + / Call up addressing functions / (> 5 s) Slave addressing Jump between master / slave + + Connect supply voltage (controller) * Prg + Esc * Address of the operating panel must be 0! 4 www.belimo.com

Controller for fire dampers BKS24-.. Menu structure Keys Menu tree Esc Prg Faults (password) Language selection Network configuration Fan release Actuator section Addressing Scenario management Configuration of fire alarm and ventilation input Configuration of reports plan management Reset to basic setting Manual system test Automatic system test Test of local actuator Adaptation Maintenance (password) Manual system test Automatic system test Test of local actuator Addressing Adaptation switch-off list Actuator info M01 M07 Main menu History Clock Inputs/ Outputs Stored faults Test results Faults of entire system Test results of entire system Set date / time Set day of the week System status Status display Reset buffer Interface / modem / printer configuration Text designation for system Info System info Network Actuator status Last test result plan status switch-off delay Actuator info www.belimo.com 5

BKS24-.. Controller for fire dampers Commissioning System configuration checklist Systems with slave Software parameter factory settings See table on page 21 Application software Addressing Procedure 1) Check electrical connection of system and switch on entire system 2) Select language 3) Address controller and external operating panel (if present), see below 4) Reset all controller to basic setting 5) Set the number of controller connected to the network on the master 6) Release necessary digital inputs on the master (for fire alarm system, input of ventilation system) 7) Set time of day For systems with slave(s), an external operating panel (Z-PKT0FSW210) is required for commissioning! 8) If desired, set parameters for automatic system test 9) If GSM modem is present, set SMS configuration 10) Set number of connected actuators at all controller 11) Address digital actuators 12) Set desired scenario at each controller 13) Set groups and system status to On 14) Trigger system test to test entire system Same software for master and slave The controller are supplied with preinstalled application software. The same software is installed in the master and the slave. System division and network addresses Master and slave are addressed from 1 to max. 12 or 32 for one operating panel. RS232 32 plan Group 1 Group 2 Group 3 Master Slave Slave BF24MP set or BFG24MP set BF24MP set or BFG24MP set BF24MP set or BFG24MP set MP1 MP1 MP1 MP BUS TECHNOLOGY BY BELIMO MP2 230 VAC MP BUS TECHNOLOGY BY BELIMO MP2 230 VAC MP BUS TECHNOLOGY BY BELIMO MP2 230 VAC MP3 MP3 MP3 to MP8 to MP8 to MP8 6 www.belimo.com

Controller for fire dampers BKS24-.. Commissioning Addressing of the controllers Addressing of the master: Keep UP and ALARM key pressed Switch on power supply of the master The following display will appear after a few seconds: PLAN ADDRESS: 1 UP: INCREASE DOWN: DECREASE ENTER: SAVE & EXIT The master always has address 1! (This is the factory setting!) The desired address can be set with the UP and DOWN key and saved with the ENTER key. Addressing of external operating panel: Address 32 is already set for the external operating panel upon delivery (default value)! Keep all 3 arrow keys pressed for at least 5 s address setting :32 I/O Board address:02 P:01 Adr Priv/Shared Trm1 32 Sh Trm2 None -- Trm3 None -- Ok?YES Address of the external operating panel Shows the address of the controller to which the operating panel is connected Should always be set to Sh (Shared) Confirm any changes by entering YES See also the separate documentation (data sheet) of the external operating panel. Addressing of slave (factory setting: address 2): Connect external operating panel to slave Keep all 3 arrow keys pressed for at least 5 s address setting : 0 Set address of external operating panel to 0! The following display appears: ADDRESS Changed Switch off power supply of slave Keep UP and ALARM key on the external operating panel pressed Switch power supply on again The following display will appear after a few seconds: PLAN ADDRESS: 2 UP: INCREASE DOWN: DECREASE ENTER: SAVE & EXIT Set address for the slave The desired address can be set with the UP and DOWN key and saved with the ENTER key. Important: After the slaves have been addressed, set the address of the external operating panel back to 32! www.belimo.com 7

BKS24-.. Controller for fire dampers Main menu Main menu The main menu is accessed by pressing the Esc key several times. Esc Group: 00/00 M01 Function: SLAVE Main menu Group status : OFF System status: OFF Group: 00/00 M02 Local configuration Actuators num.: Group: 00/00 M03 Actuators status: 1 2 3 4 5 6 7 8 C C C C C C C C Group: 00/00 M04 Safety function act. 1 2 3 4 5 6 7 8 N N N N N N N N Shows in which group you are / how many groups are present in total. Shows function of the respective station (master / slave). Switches the individual groups on and off. Factory setting: ON Switches the overall system on and off. Factory setting: OFF Enter number of connected digital and standard actuators. Enter number of digital actuators (BF-Top). Factory setting: 0 of the actuator positions. 1 8: digital actuators. C = closed, O = open Safety function display (triggered by BAE, smoke detector, excess temperature of actuator). Has safety function been triggered? N = no, Y = yes Group: 00/00 M05 Dig. act. fault: 1 2 3 4 5 6 7 8 N N N N N N N N Group: 00/00 M06 Last test result: 1 2 3 4 5 6 7 8 N N N N N N N N Group: 00/00 M07 Fault reset: 1 2 3 4 5 6 7 8 N N N N N N N N for fault in actuator. (overload, MP-Bus, etc.) Is a fault present? N = no, Y = yes of the last test result. Was a fault determined during the last test run? N = no, Y = yes Allows a pending fault message to be reset. Remark: If the fault is still present, it cannot be reset. Reset fault? N = no, Y = yes 8 www.belimo.com

Controller for fire dampers BKS24-.. Main menu Group: 00/00 M08 Status display of the digital outputs. Password entry Fan status : OFF Fault status: OFF Group reset: M09 01:0 02:0 03:0 04:0 05:0 06:0 07:0 08:0 09:0 10:0 11:0 12:0 Group on/off: M12 01:0 02:0 03:0 04:0 05:0 06:0 07:0 08:0 09:0 10:0 11:0 12:0 Digital output contact for fan release: Status Digital output contact for collective fault: Status Status display of the controller connected to the network. Non-connected stations are not displayed. 0 = inactive, not present, 1 = active Slave on = 1 Slave off = 0 The installation menu is protected by a password. Menu Password: 0000 Enter passwords using the scroll keys. Language selection Language: C01 Select menu language. ENGLISH Select menu language. Language selection Network configuration Network config. Fan release Contr. config. C02 Num. of controllers (pcoxs) present in the plan: 00 Enter number of controllers connected to the network. Factory setting: 00 Fan release C03 Delay of actions on startup: 30 s Enter fan startup delay. Factory setting: 30 s www.belimo.com 9

BKS24-.. Controller for fire dampers Actuator selection MPBUS Act. conf. C04 Actuators num.: 0 Enter number of connected actuators. Actuator selection Addressing The actuators can only be addressed if Group config. in display C05 is set to Yes. After the actuators have been addressed, Group config. must be set to OFF again! The digital actuators can be addressed in two ways: manually (MAN, with hand crank) automatically (AUTO, with serial number of the actuator). Manual addressing MPBUS Act. conf. C05 Group config: No Current act.: Configuration group: ON = addressing of the actuators possible, OFF = standard operation of the system ON / OFF Actuator that is currently being queried Number of connected digital actuators Manual addressing Actuator 1/ C06 Address. type: MAN Set address : No of the current actuator (act. 1 = MP1). Select method: manual (MAN) / automatic (AUTO). Start manual addressing (select Yes ) *. Automatic addressing * Note After Yes has been selected, the hand crank of the respective actuator must be operated within 5 minutes. The corresponding actuator then sends its serial number to the controller and is programmed with the corresponding MP address (here MP1). After the addressing has taken place, the display changes from Yes to No. Actuator 1/ C06 Address. type: AUTO Set address : No Select automatic addressing. Automatic addressing Actuator 1/ C07 Serial number: 00000-00000-000-000 Set address: No Assigns the address (in this case MP1) to the actuator. Enter the serial number of the respective actuator (with scroll and ENTER keys). Yes = Save address in actuator. 10 www.belimo.com

Controller for fire dampers BKS24-.. Scenario management Scenario management 3 predefined scenarios are available: 1) 1:1: Only the fire damper whose sensor (temperature, smoke) is triggered will close. 2) All: As soon as a sensor (temperature or smoke) in the network is triggered, all fire dampers in the entire network will close. 3) 2: Dependence between each two fire dampers (MP1-MP2, MP3-MP4, MP5-MP6, MP7-MP8). Scenario Manag. C22 Enable scenario ALL in the plan: No Scenario Manag. C23 Enable scenario 2 on the plan: No C24 Configure local or remote controller? LOCAL Activate scenario All? Factory setting: No Yes = Scenario 2 is selected for this station. Selects the controller in which the scenario is to be set. Local = master, distributed = slaves C25 Read scenario s conf of controller: 02 Read status: STOP Actuator 1 C26 Scenario : CUSTOM Group dep.: 02 Actuat.dep: 08 Reads out the scenario settings of the slaves from the master. Read in a scenario from a slave. Reading status The scenario CUSTOM is activated for actuator 1. A customer-specific scenario could be set here. Actuator 1 is dependent on actuator 8 in group 2. Save the current C36 scenario configurat. in the controller:00 Write status: STOP Scenario Manag. C37 All actuators are configurated with scenario ALL! Saves a set scenario in the corresponding slave. Enter controller address. STOP / START indicating that the scenario ALL has been activated for all actuators. Scenario ALL is active. www.belimo.com 11

BKS24-.. Controller for fire dampers Configuration of the inputs of the fire alarm and ventilation system Config. of fire alarm and ventilation input Master Control. C49 Enable F&S alarm from D.I.: Yes Master Control. C50 Enable D.I. from ventilation sys: No Configuration of the actuator messages plan management Actuator 1/ C51 Enable indication of Safety message : Yes Gen. fault msg.: Yes Is a fire alarm system connected to the master? Yes / No. Factory setting: Yes Close fire dampers when the ventilation system is switched off? (Protection of tangible assets when ventilation system is switched off) No / Yes. Factory setting: No You can define for each actuator whether the respective messages and faults are to be output. These settings may only be changed after consultation with the person responsible for safety! Message config. Transmit safety message? Factory setting: Yes Transmit fault message? Factory setting: Yes plan management plan Management C61 Enable fault detect offline loc.: Yes offline plan: Yes The plan messages can be switched off if necessary. Local message display: Yes / No. Factory setting: Yes plan message display: Yes / No. Factory setting: Yes 12 www.belimo.com

Controller for fire dampers BKS24-.. Reset to basic setting Reset to basic setting Manual system test Automatic system test plan Management C62 Delay fault detect. offline loc.: 000s offline plan: 000s Reset values to default: Manual test Start test: No C64 No C65 A fault is displayed when the network is interrupted. The delay time Disconnection until fault display can be set here. Local delay time in s. Factory setting: 30 s plan delay time in s. Factory setting: 30 s Reset parameters of the respective station to their basic setting? No / Yes. Factory setting: See Appendix A test run of the entire network can be manually triggered here. All actuators move into the safety position (Closed) and then open again. Manual system test Trigger test run? No / Yes Automatic system test C66 Enable automatic self-test: No Interval: EVERY 24h Self-test config C67 The system can be set here so that it automatically carries out a periodic self-test of the entire network. The period type and the time can also be set. Every 24 hours / monthly / weekly / every 48 hours Setting of start day and time. Start on : Monday Time : 00 : 00 Enter start day. Enter time. www.belimo.com 13

BKS24-.. Controller for fire dampers Saves the test result in the history file. Delay before C68 save the result of self-test: 300s Set delay time in s. Factory setting: 300 s Automatic system test Test of local actuator Test of local actuator Adaptation Local act. test: C69 A1:0 A2:0 A3:0 A4:0 A5:0 A6:0 A7:0 A8:0 Adaptation C70 A1:0 A2:0 A3:0 A4:0 A5:0 A6:0 A7:0 A8:0 Possibility of testing a single actuator within the network. 0 = Standard operation 1 = Start test run When the test run has been successfully completed, the display automatically returns to 0. Adaptation of a new actuator to the fire damper. 0 = Standard operation 1 = Start adaptation When the adaptation has been successfully completed, the display automatically returns to 0. Adaptation switch-off delay switch-off delay Actuator info Actuator info New password C71 LCD Backlight-off delay: 000s Actuator 1/ C72 ver.hw : 00000 ver.bios: 0000000000 00000-00000-000-000 The switch-off delay time of the display background lighting can be set. Switch-off delay in s. Factory setting: 120 s of hardware / software version. of hardware version. of BIOS and software version. of actuator serial number. INSTALL. Menu C80 Set new password using the scroll keys. Confirm with ENTER key. New password: 0000 Enter new password. 14 www.belimo.com

Controller for fire dampers BKS24-.. Maintenance Password entry Manual system test Maintenance Manual system test Automatic system test Maintenance Menu Password: 0000 Manual test Start test: No A01 A02 Enable automatic self-test: No Interval: EVERY 24h Self-test config A03 Enter the password using the scroll keys. Confirm with ENTER key. Enter password. A test run of the entire network can be manually triggered here. All actuators move into the safety position (Closed) and then open again. Trigger test run? No / Yes The system can be set here so that it automatically carries out a periodic self-test of the entire network. The period type and the time can also be set. Maintenance Automatic system test Every 24 hours / monthly / weekly / every 48 hours Setting of start day and time. Start on : Monday Time : 00 : 00 Delay before A04 save the result of self-test: 000s Enter start day. Enter time. Saves the test result in the history file. Set delay time in s. Factory setting: 300 s Test of local actuator Maintenance Test of local actuator Local act. test: A05 A1:0 A2:0 A3:0 A4:0 A5:0 A6:0 A7:0 A8:0 Possibility of testing a single actuator within the network. 0 = Standard operation 1 = Start test run When the test run has been successfully completed, the display automatically returns to 0. www.belimo.com 15

BKS24-.. Controller for fire dampers Maintenance Addressing The actuators can only be addressed if Group config. in display A06 is set to Yes. After the actuators have been addressed, Group config must be set to OFF again! The digital actuators can be addressed in two ways: manually (MAN, with hand crank) automatically (AUTO, with serial number of the actuator). Manual addressing Maintenance Manual addressing Automatic addressing MPBUS Act. conf. A06 Group config: No Current act.: Actuator 1/ A07 Address. type: MAN Set address : No of the current actuator (Act. 1 = MP1). Configure group: Yes / No. Select method: manual (MAN) / automatic (AUTO). Start manual addressing (select Yes ) *. * Note After Yes has been selected, the hand crank of the respective actuator must be operated within 5 minutes. The corresponding actuator then sends its serial number to the controller and is programmed with the corresponding MP address (here MP1). After the addressing has taken place, the display changes from Yes to No. Maintenance Actuator 1/ A07 Address. type: AUTO Set address : No Select automatic addressing. Automatic addressing Actuator 1/ A08 Serial number: 00000-00000-000-000 Set address: No Assigns the address (in this case MP1) to the actuator. Enter the serial number of the respective actuator (with scroll and ENTER keys). Yes = Save address in actuator. Adaptation Maintenance Adaptation Adaptation A23 A1:0 A2:0 A3:0 A4:0 A5:0 A6:0 A7:0 A8:0 Adaptation of a new actuator to the fire damper. 0 = Standard operation 1 = Start adaptation When the adaptation has been successfully completed, the display automatically returns to 0. switch-off delay Maintenance switch-off delay A24 LCD Backlight-off delay: 120s The switch-off delay time of the display background lighting can be set. Switch-off delay in s. Factory setting: 120 s 16 www.belimo.com

Controller for fire dampers BKS24-.. Maintenance Actuator info of software number / serial number of the actuator. Maintenance Actuator 1/ A25 Actuator info New password History Viewing local fault history ver.bios: 0000000000 00000-00000-000-000 Fault history: MAINTENANCE Menu A33 New password: 0000 H01 of BIOS and software version. of actuator serial number. Set new password using the scroll keys. Confirm with ENTER key. Enter new password. History N 00 00:00 00/00/00 Fault number Time / date Stored faults NO FAULTS! H02 Erase local faults history memory: No Fault in plain text. Delete fault history at this station. Delete? No / Yes. Viewing local test history History Test results Test history: H03 n 00 00:00 00/00/00 1 2 3 4 5 6 7 8 N N N N N N N N H04 Erase local test history memory: No Fault number Time / date Fault determined during test run? No / Yes (N / Y). Delete test history at this station? No / Yes www.belimo.com 17

BKS24-.. Controller for fire dampers History Viewing fault history of entire system Stored Master H05 History Fault history: Last update status: wait... Faults of entire system Mast. al. hist.: H06 Group:00 N 00 00:00 00/00/00 NO FAULTS! Viewing test history of entire system History Stored Master Test history: Last update Status: wait... H07 Test results of entire system Mast.test grp:00 H08 00/00/00 00:00 1 2 3 4 5 6 7 8 N N N N N N N N Load histories of slaves into master. The slaves send their history data to the master. Select group and fault number. Time / date Fault in plain text. Load saved test results of the slaves into the master. The slaves send their history data to the master. Select group and fault number. Date / time Fault determined during test run? No / Yes (N / Y). Clock Setting date, time and day of week Today: K01 Shows set time and date. Clock Set date, time Clock 00:00 00/00/00 Change time: K02 00:00 00/00/00 Day of week: Time / date Set time and date. Set day of week. Set day of week 18 www.belimo.com

Controller for fire dampers BKS24-.. Inputs/outputs Status display Inputs/ outputs Status display Digital Input 1: C 2: C 3: C 4: C 5: C 6: C I01 Digital Output I02 1: O 2: O 3: O 4: O 5: O I03 BMS ID : 000 Speed : 1200 bps Protocol : Carel Erase message queue? I04 Shows the status of the digital inputs of the station. C = closed, O = open C = closed, O = open Shows the status of the digital outputs of the station. C = closed, O = open C = closed, O = open Shows ID number, transmission speed and transmission protocol ID number of the system Transmission speed Transmission protocol Shows inquiry to delete the internal buffer of the interface No Delete internal buffer of the interface: No / Yes Identification Site ID: 01 I09 Shows text designation for the system Name: Building A Text designation for system Groupe 01 I10 Shows text designation for the group Name: Ground Floor Text designation for group External modem: For installation and parameterisation, see separate modem documentation www.belimo.com 19

BKS24-.. Controller for fire dampers Info System info Info System info Network Remark: The network menu is only displayed when at least one slave is connected to the master! Actuator status CAREL S.p.A. F01 Brugine (PD) Italia Cod.: FLBELMFS0A Ver.: 2.9 04/07/07 System info F02 Card type: pco1xs Bios:04.10 20/02/07 Boot:04.03 03/07/06 Network status N01 Call group: 02 Information on the version of the installed application software. Belimo application code Version of the application software of the BIOS and boot version number. BIOS version number Boot version number Network Actuator status Selection of the group. Select group number. Group: 02/04 N02 Actuators status: 1 2 3 4 5 6 7 8 C C C C C C C C Group: 02/04 N03 Safety funct. active 1 2 3 4 5 6 7 8 N N N N N N N N Status display of the actuators (group 02). O = open / C = closed Status display of the safety function of the actuators. A = active / N = not active Last test result Network Last test result Group: 02/04 N04 Last test result: 1 2 3 4 5 6 7 8 N N N N N N N N Group: 02/04 N05 Actuators fault: 1 2 3 4 5 6 7 8 N N N N N N N N Status display of last test result: A = active / N = not active Fault with digital actuator MP7, group 02. Fault with digital actuator MP7, group 02. A = active / N = not active 20 www.belimo.com

Controller for fire dampers BKS24-.. Software parameter factory settings Parameters Menu page Factory setting (Range) Group status M01 on System status M01 off Number of digital actuators M02 0 (0...8) Number of stations in plan C02 0 (1...15) Ventilation delay C03 30 s (0...999 s) Number of standard actuators C04 0 (0...2) Delay of standard actuators during startup C04 80 s (0...99 s) Scenario management C22, C23 no Input of fire alarm system C49 yes Input of ventilation system C50 no Safety-relevant messages of the actuators C51 C60 yes Fault messages of the actuators C51 C60 yes plan management C61 yes plan delay of fault display C62 30 s (0...99 s) Save test results of the automatic test run: Delay C68 300 s (0...999 s) LCD Backlight-off delay C71 120 s (0...999 s) Status of the digital output contacts Status of the digital outputs Condition Selected scenario Fan release Contact Fault Contact System test (test of all dampers) 1, 2, or all OFF Open OFF Open Test of an individual damper 1, 2, or all ON Closed OFF Open plan interruption 1, 2, or all ON Closed ON Closed Sensor (channel, excess temperature, smoke detector) triggered 1 OFF Open ON Closed Sensor (channel, excess temperature, smoke detector) triggered 2 ON 1) Closed ON Closed Sensor (channel, excess temperature, smoke detector) triggered all OFF Open ON Closed Ventilation system off (dig. input open) 1, 2, or all ON Closed OFF Open Ventilation system on (dig. input closed) 1, 2, or all OFF 2) Open OFF Open Fire alarm system triggered (dig. input open) 1, 2, or all OFF Open OFF Open Fire alarm system in standard operation (dig. input closed) 1, 2, or all ON Closed OFF Open 1) Changes to OFF as soon as the last damper of the master controller has closed 2) Changes to ON as soon as the first damper of the master controller is open www.belimo.com 21

BKS24-.. Controller for fire dampers Troubleshooting Checking / maintenance Please consult the following table before calling the responsible maintenance service! System ok! System: Off Group: Off System alarms 01: 02: 03: 04: 05: 06: Meaning Solution System works perfectly, no further steps necessary. The overall system and the current group are switched off. Fault display Possible cause Solution Shows in which group a fault is present (example: group 2). = No fault = Fault Fault display Possible cause Solution Select system and group and switch them on. Update the faults stored in the History menu of the master (screen H5). Select group 2 in screen H6 and read out the detailed fault description. Carry out further steps according to the displayed fault. AL01 Fire&Smoke alarm from D.I. (master) External fire alarm system reports fire alarm and has closed all fire dampers. Check the status of the fire alarm system. Fault display Possible cause Solution Fault messages not available actuator 1 AL04 The bus connection or the supply voltage to the corresponding actuator is interrupted. Check the bus connection and the supply voltage at the actuator. 22 www.belimo.com

Controller for fire dampers BKS24-.. Troubleshooting Fault display Possible cause Solution AL20 Fault: local unit off-line plan AL21 Fault: Group 02 off-line plan AL52 Warning: Actuator 1 closed in dependence The local controller can no longer communicate via the plan bus. Fault display Possible cause Solution The first slave (group 02) can no longer communicate via plan bus. Fault display Possible cause Solution Digital actuator 1 (MP1) has been closed in dependence on an other actuator. Fault display Possible cause Solution Check plan bus connection. Check plan connection. Scroll further using the scroll keys until the responsible fault is displayed, e.g. Channel temperature > 72 C digital actuator 2. This means that actuator 1 has been closed in dependence on actuator 2 (scenario 2 is active). Group: 00/00 M03 Actuators status: 1 2 3 4 5 6 7 8 O O O O O * O O Actuator is not correctly addressed. The display * means that digital actuator 6 (MP6) has not been correctly addressed; the MP-Bus line or the power supply to the actuator is interrupted. 1) Check MP-Bus connection 2) Check power supply of the actuator 3) Address actuator 6 again www.belimo.com 23

BKS24-.. Controller for fire dampers Dimensions Dimensional diagram of BKS24-.. controller Accessories External operating panel Z-PKT0FSW210 Telephone cable Z-S90CONN000 Z-PLW0PGSM00 GSM kit Z-PCO100MDM0 110 140 60 See separate documentation. Cable with telephone plugs. Dual-band modem kit with antenna, connecting cable and power pack (see separate documentation). RS232 interface card for connecting GSM modem or serial protocol printer. 24 www.belimo.com T3-BKS24 en 09.2007 Subject to changes