Verint-Supplied Equipment Guide for Nextiva Enterprise

Similar documents
Microsoft SharePoint Server 2010 on Dell Systems

VMware Infrastructure Update 1 for Dell PowerEdge Systems. Deployment Guide. support.dell.com

Dell PowerVault NX Windows NAS Series Configuration Guide

Performance Comparisons of Dell PowerEdge Servers with SQL Server 2000 Service Pack 4 Enterprise Product Group (EPG)

VMware Infrastructure 3.5 for Dell PowerEdge Systems. Deployment Guide. support.dell.com

Surveillance Dell EMC Storage with Verint Nextiva

Dell Microsoft Business Intelligence and Data Warehousing Reference Configuration Performance Results Phase III

Microsoft SQL Server 2012 Fast Track Reference Architecture Using PowerEdge R720 and Compellent SC8000

Scalability Guidelines

VMware Technology Overview. Leverage Nextiva Video Management Solution with VMware Virtualization Technology

Database Solutions Engineering. Best Practices for running Microsoft SQL Server and Microsoft Hyper-V on Dell PowerEdge Servers and Storage

VMware Infrastructure Update 1 for Dell PowerEdge Systems. Deployment Guide. support.dell.com

VMware Infrastructure 3.5 Update 2 for Dell PowerEdge Systems. Deployment Guide. support.dell.com

Nextiva Review Operator Guide. Software Release 6.0

DELL Reference Configuration Microsoft SQL Server 2008 Fast Track Data Warehouse

10Gb iscsi Initiators

Retired. For more information on HP's ProLiant Security Server visit:

SanDisk DAS Cache Compatibility Matrix

VMware VMmark V1.1 Results

Storage Consolidation with the Dell PowerVault MD3000i iscsi Storage

Video, Access & Switching Solutions!

White Paper. Dell Reference Configuration

Microsoft SQL Server 2012 Fast Track Reference Configuration Using PowerEdge R720 and EqualLogic PS6110XV Arrays

Dell Storage NX Windows NAS Series Configuration Guide

Service Overview. Dell Services. Service Description: PowerEdge & PowerVault Maintenance

Impact 360 Recording. Integration Service. Cisco Integration Guide

DELL EMC NX WINDOWS NAS SERIES CONFIGURATION GUIDE

DELL STORAGE NX WINDOWS NAS SERIES CONFIGURATION GUIDE

Specification. Platform Requirements for VANTAGE Marine 11.6

HD Network Video Recorder Workstation

Video, Access & Switching Solutions!

Teradici APEX 2800 for VMware Horizon View

Video Surveillance Storage and Verint Nextiva NetApp Video Surveillance Storage Solution

Retired. Windows Server 2008 R2 for Itanium-Based Systems offers the following high-end features and capabilities:

Aster Database Platform/OS Support Matrix, version 6.00

Dell Microsoft Reference Configuration Performance Results

60TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2016 using Dell EMC PowerEdge R730 and SC5020

IBM Shared Disk Clustering. Hardware Reference

EMC CLARiiON CX3 Series FCP

A Performance Characterization of Microsoft SQL Server 2005 Virtual Machines on Dell PowerEdge Servers Running VMware ESX Server 3.

Microsoft Windows Server 2008 On Integrity Servers Overview

Impact 360 Express. Features and Benefits of Content Producer

Dell EMC PowerEdge R740xd as a Dedicated Milestone Server, Using Nvidia GPU Hardware Acceleration

StorNext M440 Site Planning Guide

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell Storage PS Series Arrays

Aster Database Platform/OS Support Matrix, version 5.0.2

Ultimate performance and security in a 2U Form factor.

Aster Database Platform/OS Support Matrix, version 6.10

Hardware & Software Specification i2itracks/popiq

Reference Architecture

V18.1Hardware and System Requirements

HARDWARE & ENVIRONMENTAL SPECIFICATIONS TECHNICAL BRIEF

Altos T310 F3 Specifications

Dell Reference Configuration for Large Oracle Database Deployments on Dell EqualLogic Storage

vstart 50 VMware vsphere Solution Specification


Altos R320 F3 Specifications. Product overview. Product views. Internal view

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell EqualLogic Storage Arrays

Dell PowerEdge R910 SQL OLTP Virtualization Study Measuring Performance and Power Improvements of New Intel Xeon E7 Processors and Low-Voltage Memory

Nextiva Mosaic Virtual View Operator Guide. Software Release 5.1

Dell TM with Oracle Database Enterprise Edition Running Windows Server 2008

System Configuration Guide

Teradata Aster Database Platform/OS Support Matrix, version AD

Nextiva S4300-BR. Installation Guide

Efficient Video Distribution Networks with Multicast: IGMP Querier and PIM-DM

IBM System x3200 Entry server for retail, file and print or network infrastructure applications

QuickSpecs. Compaq ProLiant Clusters for UnixWare 7 - U/100 Kit M ODELS S TANDARD FEATURES C OMPONENTS. Retired

Surveillance Dell EMC Storage with Cisco Video Surveillance Manager

Molecular Devices High Content Screening Computer Specifications

TN1070: Verint Master Server Under

Content Producer. User Guide

Avigilon Control Center 6 Software

Ultimate performance and security in a 2U Form factor.

Syncro CS e Controller

DELL POWERVAULT MD FAMILY MODULAR STORAGE THE DELL POWERVAULT MD STORAGE FAMILY

DELL MICROSOFT REFERENCE CONFIGURATIONS PHASE II 7 TERABYTE DATA WAREHOUSE

IT and Interface Requirements

Exchange Server 2007 Performance Comparison of the Dell PowerEdge 2950 and HP Proliant DL385 G2 Servers

Surveillance Dell EMC Storage with Bosch Video Recording Manager

Competitive Power Savings with VMware Consolidation on the Dell PowerEdge 2950

Intel Xeon E v4, Windows Server 2016 Standard, 16GB Memory, 1TB SAS Hard Drive and a 3 Year Warranty

StoneGate Management Center version 5.2. Hardware Requirements

Dell DL4300 Appliance Interoperability Guide

The HP Blade Workstation Solution A new paradigm in workstation computing featuring the HP ProLiant xw460c Blade Workstation

Lifecycle Controller Operating System Driver Pack Version Reference Guide

ArcSight Express for the Mid-Market

Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode)

Acer AT110 F2 Specifications

NEC Express5800/B120f-h System Configuration Guide

Network Refresh Project

Four-Socket Server Consolidation Using SQL Server 2008

MegaRAID SAS e RAID Controller

Deployment of VMware Infrastructure 3 on Dell PowerEdge Blade Servers

IBM Proventia Management SiteProtector. Scalability Guidelines Version 2.0, Service Pack 7.0

Performance Scaling. When deciding how to implement a virtualized environment. with Dell PowerEdge 2950 Servers and VMware Virtual Infrastructure 3

Microsoft SQL Server in a VMware Environment on Dell PowerEdge R810 Servers and Dell EqualLogic Storage

EMC SYMMETRIX VMAX 40K SYSTEM

Application and Data Server (ADS/ADX) Ready Computer Systems Product Bulletin

One West Otterson Street, Nashua, New Hampshire ph: (603) fax: (603) Website:

Dell PowerEdge R720xd with PERC H710P: A Balanced Configuration for Microsoft Exchange 2010 Solutions

Transcription:

Verint-Supplied Equipment Guide for Nextiva Enterprise For Software Releases 5.1, 6.0, and 6.1 December 18, 2009

2009 Verint Systems Inc. All Rights Reserved Worldwide. Confidential and Proprietary Information of Verint Systems Inc. All materials (regardless of form and including, without limitation, software applications, documentation, and any other information relating to Verint Systems, its products or services) are the exclusive property of Verint Systems Inc. Only expressly authorized individuals under obligations of confidentiality are permitted to review materials in this document. By reviewing these materials, you agree to not disclose these materials to any third party unless expressly authorized by Verint Systems, and to protect the materials as confidential and trade secret information. Any unauthorized review, retransmission, dissemination or other use of these materials is strictly prohibited. If you are not authorized to review these materials, please return these materials (and any copies) from where they were obtained. All materials found herein are provided AS IS and without warranty of any kind. The Verint Systems Inc. products are protected by one or more of the following U.S., European or International Patents: USPN 5,659,768; USPN 5,689,442; USPN 5,790,798; USPN 6,278,978; USPN 6,370,574; USPN 6,404,857; USPN 6,510,220; USPN 6,724,887; USPN 6,751,297; USPN 6,757,361; USPN 6,782,093; USPN 6,839,667; USPN 6,952,732; USPN 6,959,078; USPN 6,959,405; USPN 7,047,296; USPN 7,149,788; USPN 7,155,399; USPN 7,203,285; USPN 7,216,162; USPN 7,219,138; USPN 7,254,546; USPN 7,281,173; USPN 7,284,049; USPN 7,325,190; USPN 7,466,816; USPN 7,478,051; USPN RE40,634; and other provisional rights from one or more of the following Published US Patent Applications: US 11/394,408; US 11/771,499; US 11/396,514; US 11/772,440; US 11/565,943; US 11/565,946; US 11/565,948; US 11/540,739; US 11/540,086; US 11/541,313; US 11/541,252; US 11/540,282; US 11/529,947; US 11/540,785; US 11/540,736; US 11/540,904; US 11/540,353; US 11/608,340; US 11/608,350; US 11/608,358; US 11/567,808; US 11/692,983; US 11/693,933; US 11/693,923; US 11/693,828; US 11/567,852; US 11/608,440; US 12/015,621; US 11/540,322; US 11/924,201; US 11/616,490; US 11/621,134; US 11/752,458; US 11/712,933; US 11/824,980; US 11/729,185; US 11/804,748; US 11/831,260; US 11/395,992; US 11/359,319; US 11/359,195; US 11/359,357; US 10/832,509; US 11/742,733; US 11/831,257; US 11/831,250; US 11/691,530; US 11/479,267; US 11/529,942; US 11/768,349; US 11/540,281; US 10/633,357; US 11/693,899; US 11/479,056; US 11/529,132; US 11/540,320; US 11/037,604; US 11/529,842; US 11/540,171; US 11/478,714; US 11/529,946; US 11/868,656; US 11/776,659; US 11/090,638; US 11/410,004; US 10/771,315; US 10/771,409; US 11/540,900; US 11/528,267; US 12/118,781; and other U.S. and International Patents and Patents Pending. VERINT, the VERINT logo, ACTIONABLE INTELLIGENCE, POWERING ACTIONABLE INTELLIGENCE, WITNESS ACTIONABLE SOLUTIONS, STAR-GATE, RELIANT, VANTAGE, X-TRACT, NEXTIVA, ULTRA, AUDIOLOG, WITNESS, the WITNESS logo, IMPACT 360, the IMPACT 360 logo, IMPROVE EVERYTHING, EQUALITY, CONTACTSTORE, and CLICK2STAFF are trademarks or registered trademarks of Verint Systems Inc. or its subsidiaries. Other trademarks mentioned are the property of their respective owners. www.verint.com/videosolutions Publication date: December 18, 2009 Verint Video Intelligence Solutions

Contents Introduction... 4 Basic Requirements... 4 Nextiva Workstation Applications... 6 Dell Precision T3500 Workstation... 7 Verint Part Numbers for the Dell Precision T3500 Workstation... 7 Nextiva Server Applications... 8 Dell PowerEdge R710... 8 Nextiva Recorder Server and Nextiva Master Recorder (with Internal Storage)... 9 Part Numbers for the Nextiva Recorder Server and Master Recorder (with Internal Storage)... 9 Marathon Master Server Failover Platform... 10 Part Numbers for the Master Server Failover Platform... 10 Dell PowerEdge R300 and R410... 11 Nextiva Recorder Server, Master Recorder, and ESM Server (with External SCSI Attached Storage)... 11 Part Numbers for the Nextiva Recorder Server, Master Recorder, and ESM Server (with External SCSI Attached Storage)... 12 Nextiva Recorder Server, Master Recorder, and ESM Server (with External Fibre Channel Attached Storage)... 12 Part Numbers for the Nextiva Recorder Server, Master Recorder, and ESM Server (with External Fibre Channel Attached Storage)... 13 Nextiva Master Server... 14 Part Numbers for the Nextiva Master Server... 14 Nextiva Surveillance Analytics and IVAP Servers... 14 Part Numbers for the Nextiva Surveillance Analytics and IVAP Servers... 15 Nextiva Media Gateway Server... 15 Part Numbers for the Nextiva Media Gateway Server... 15 External Storage... 16 Dell PowerVault MD1000... 16 Nexsan SataBeast... 17 Ethernet Switches... 18 Verint-Supplied Dell Ethernet Switches... 18 Verint-Supplied QLogic Switch Kit... 19 Verint Video Intelligence Solutions 3

1 Introduction Verint has certified the hardware for Nextiva Workstation and Server applications on the Dell platform. Verint supplies Dell systems fully staged and configured with the relevant operating system and third-party applications, as well as with all relevant Nextiva Workstation and Server components installed and ready to be configured for your deployment. The Verint-Supplied Equipment Guide for Nextiva Enterprise provides detailed specifications and part numbers for Dell systems supplied by Verint. This information is detailed for all currently supported Nextiva software release-levels: 5.1, 6.0, and 6.1. The Verint-Supplied Equipment Guide for Nextiva Enterprise complements the Customer-Furnished Equipment Guide for Nextiva Enterprise and the Nextiva System Planning Guide. The Customer-Furnished Equipment Guide for Nextiva Enterprise provides hardware and software specifications for Nextiva Workstation and Server applications; this document guides customers who will be furnishing their own workstation and server hardware platforms for their Nextiva deployment. The Nextiva System Planning Guide includes system and site information required for connectivity and operation of Nextiva components. Basic Requirements Having the correct equipment on hand helps ensure a successful Nextiva deployment. Each Nextiva platform and sub-system is comprised of several layers, including the following: Hardware: Either Verint-supplied or customer-furnished hardware Operating system: Depending upon your Nextiva deployment and Nextiva software release-level (5.1, 6.0, or 6.1), you will need valid licenses for either the English US or French (supported by Nextiva Review, Control Center, and Surveillance Analytics) versions of the supported Microsoft Windows operating systems. Verint provides all relevant Microsoft license - including Operating System, Microsoft SQL, and MOM licenses - with Dell systems purchased through Verint. For more information, refer to the Nextiva System Planning Guide. Note: Supported Service Pack levels must be installed on the operating system prior to installing any Nextiva components. Verint software: You will need licenses for Nextiva workstation and server applications. Verint provides all relevant Verint software licenses - including Nextiva Server and Workstation licenses - with Dell systems purchased through Verint. For more information, refer to the Nextiva System Planning Guide. External storage devices for long-term video storage. Ethernet switches to connect the Nextiva deployment to the network. Server failover solutions. Nextiva Intelligent Edge Devices to transmit or receive video signals through the IP network. Verint Video Intelligence Solutions 4

Environment configuration: Per project, including recommended IP addressing and machine naming conventions. Third-party software: Additional third-party applications that are not included with the operating system or with the Nextiva installation package, such as network monitoring tools, Windows Media services, and Internet Explorer. Drivers: Additional drivers not included with the operating system. Verint Video Intelligence Solutions 5

2 Nextiva Workstation Applications Nextiva Workstations host the following Nextiva platforms: Nextiva Review - The client application used to stream live and recorded video and perform other operator functions. Nextiva Control Center - The client application used to configure and manage the Nextiva system, as well as to monitor the Nextiva system using HealthCheck. Nextiva Surveillance Analytics - The client applications needed to set up, configure, optimize, and operate Nextiva Surveillance Analytics. Applications include Analytics Rule Builder, Object Sizing Assistant, Analytics Engine Configurator, and Scene Optimizer. Nextiva Client SDK - An application programming interface for integrating external applications to Nextiva. Some Nextiva workstation applications, such as Nextiva Review and the Client SDK, can be installed as separate components; while others, such as Nextiva Surveillance Analytics, are installed in combination with another Nextiva Workstation component, as listed below: Nextiva Review Nextiva Review and Control Center Nextiva Review, Control Center, and Surveillance Analytics Nextiva Client SDK Nextiva Control Center Verint has certified the Dell Precision T3500 platform for Nextiva Workstation applications. Verint Video Intelligence Solutions 6

Dell Precision T3500 Workstation The Dell Precision T3500 workstations are supplied fully staged and pre-configured with the relevant operating system, third-party applications, and Nextiva workstation application(s). This section details the system specifications for the Dell Precision T3500 workstation; Verint part numbers for the Dell Precision T3500 platform are also provided. The Dell Precision T3500 is certified for Nextiva workstation applications with the following configuration: Component Processor Memory Disk Network interface card DVD Drive Video Card Monitor Specifications 2.26 GHz Intel Quad Core Processor E5520 2 GB Integrated SATA 3.0 GB/s controller 1 X 250 GB SATA disk 1000BASE-T Ethernet SATA 16X DVD+/-RW nvidia Quadro FX580 PCIe (256 MB) Optional 17-inch flat panel, or optional 19 or 22-inch wide screen flat panel Note: The specifications listed above may change depending on currently available system updates to the Dell Precision T3500 product line. Verint Part Numbers for the Dell Precision T3500 Workstation The following table lists the part numbers for the Verint-supplied Dell Precision T3500 workstations: Verint Part Numbers Description Nextiva 5.1 Nextiva 6.0 Nextiva 6.1 Dell Precision T3500 workstation with Dell E1708FP 17-inch flat panel monitor Dell Precision T3500 workstation with Dell E198FP 19-inch wide screen flat panel monitor Dell Precision T3500 workstation with Dell E228FP 22-inch wide screen flat panel monitor Dell Precision T3500 workstation (without monitor) Dell 19-inch wide screen flat panel (monitor only) Dell 22-inch wide screen flat panel (monitor only) NEX-5.1-DWRK-S NEX-6.0-DWRK-S NEX-6.1-DWRK-S NEX-5.1-DWRK-19W NEX-6.0-DWRK-19W NEX-6.1-DWRK-19W NEX-5.1-DWRK-22W NEX-6.0-DWRK-22W NEX-6.1-DWRK-22W NEX-5.1-WRK-S NEX-6.0-DWRK NEX-6.1-DWRK NEX-5.1-DSCN-W19 NEX-6.0-DSCN-W19 NEX-6.1-DSCN-W19 NEX-5.1-DSCN-W22 NEX-6.0-DSCN-W22 NEX-6.1-DSCN-W22 Verint Video Intelligence Solutions 7

3 Nextiva Server Applications Nextiva Servers host the following Nextiva Server platforms: Nextiva Master Recorder (with Internal Storage, External SCSI Attached Storage, or External Fibre Channel Attached Storage) Nextiva Recorder Server (with Internal Storage, External SCSI Attached Storage, or External Fibre Channel Attached Storage) Nextiva Enterprise Storage Manager Server (with External SCSI Attached Storage or External Fibre Channel Attached Storage) Nextiva Master Server Nextiva Web Server Nextiva Surveillance Analytics Server and Nextiva Video Analytics Processor (IVAP) Server Nextiva Media Gateway Server Nextiva Marathon Master Server Failover Platform Verint has certified the Dell PowerEdge R710, R300, and the R410 hardware platforms for Nextiva server applications. Dell PowerEdge R710 Verint supplies Dell PowerEdge R710 servers fully staged and pre-configured with the relevant operating system, third-party applications, and Nextiva server application(s). This section details the system specifications for the Dell PowerEdge R710 server; Verint part numbers for the Dell PowerEdge R710 platform are also provided. Note: All specifications listed in this document may change depending on currently available system updates to the Dell PowerEdge R710 product line. Verint has certified the Dell PowerEdge R710 for the following Nextiva Server platforms: Nextiva Recorder Server (with internal storage) Nextiva Master Recorder (with internal storage) Marathon Master Server Failover platform Verint Video Intelligence Solutions 8

Nextiva Recorder Server and Nextiva Master Recorder (with Internal Storage) This section provides the specifications for the Nextiva Recorder Server and Nextiva Master Recorder with internal storage on the Verint-supplied Dell PowerEdge R710 server. Component Processor Memory Specifications 2.26 GHz Xeon E5520 (Quad-Core) 2 GB Disk 2 X 160 GB SATA disk in RAID 1 2 x 1 TB 7.2k SATA (for 2.0 TB storage) or 4 x 1 TB 7.2k SATA (for 4.0 TB storage) RAID Network interface card PERC 6/i SAS RAID Controller, PCI Express, 256 MB cache 2 internal x4 SAS connectors 1000BASE-T Ethernet Part Numbers for the Nextiva Recorder Server and Master Recorder (with Internal Storage) The following table lists the part numbers for the Nextiva Recorder Server and Nextiva Master Recorder with internal storage on the Verint-supplied Dell PowerEdge R710 platform: Nextiva Release Level Description Verint Part Number 6.1 Nextiva Master Recorder with 2.0 TB of storage NEX-6.1-MR-D2.0TB Nextiva Master Recorder with 4.0 TB of storage Nextiva Recorder Server with 2.0 TB of storage Nextiva Recorder Server with 4.0 TB of storage NEX-6.1-MR-D4.0TB NEX-6.1-RE-D2.0TB NEX-6.1-RE-D4.0TB 6.0 Nextiva Master Recorder with 2.0 TB of storage NEX-6.0-MR-D2.0TB Nextiva Master Recorder with 4.0 TB of storage Nextiva Recorder Server with 2.0 TB of storage Nextiva Recorder Server with 4.0 TB of storage NEX-6.0-MR-D4.0TB NEX-6.0-RE-D2.0TB NEX-6.0-RE-D4.0TB 5.1 Nextiva Master Recorder with 2.0 TB of storage NEX-5.1-MR-D2.0TB Nextiva Master Recorder with 4.0 TB of storage Nextiva Recorder Server with 2.0 TB of storage Nextiva Recorder Server with 4.0 TB of storage NEX-5.1-MR-D4.0TB NEX-5.1-RE-D2.0TB NEX-5.1-RE-D4.0TB Verint Video Intelligence Solutions 9

Marathon Master Server Failover Platform This section provides the technical specifications for the Marathon Master Server Failover platform on the Dell PowerEdge R710 server. Component Processor Memory Specifications 2.93 GHz Intel Xeon X5570 (Quad-Core) 4096 MB (for each co-server) Disk 2 X 160 GB SATA in RAID 1 2 X 250 GB SATA in RAID 1 RAID Network interface card Operating system PERC 6/i SAS RAID controller, PCI Express, 256 MB cache 2 internal x4 SAS connectors 4 X 1000BASE-T Ethernet with independent controllers on both Marathon servers Windows Server 2003 SE with slipstreamed (integrated) SP2 for EverRun release 7.1.1.1200 Part Numbers for the Master Server Failover Platform The following table lists the part numbers for the Marathon Master Server Failover platform on the Verintsupplied Dell PowerEdge R710 Server: Nextiva Release Level Description Verint Part Number 6.1 Marathon Master Server Failover (hardware platform only) NEX-6.1-MS-DELL-HFO Complete Failover Package (combines hardware and software platforms) NEX-6.1-MS-DELL-CFO 6.0 Marathon Master Server Failover (hardware platform only) NEX-6.0-MS-DELL-HFO Complete Failover Package (combines hardware and software platforms) NEX-6.0-MS-DELL-CFO 5.1 Marathon Master Server Failover (hardware platform only) NEX-5.1-MS-DELL-HFO Complete Failover Package (combines hardware and software platforms) NEX-5.1-MS-DELL-CFO Verint Video Intelligence Solutions 10

Dell PowerEdge R300 and R410 Verint supplies the Dell PowerEdge R300 and R410 servers fully staged and pre-configured with the relevant operating system, third-party applications, and Nextiva server application(s). Note: The Dell PowerEdge R300 platform is available for both Nextiva 5.1 and 6.0 deployments; while the Dell PowerEdge R410 platform is supplied for Nextiva 6.1 deployments. All specifications listed in this document may change depending on currently available system updates to the Dell PowerEdge R300 and R410 product lines. This section details the system specifications for the Dell PowerEdge R300 and R410 servers; Verint part numbers for both hardware platforms are also provided. Verint has certified the Dell PowerEdge R300 and R410 servers for the following Nextiva Server platforms: Nextiva Recorder Server (with external SCSI and Fibre Channel-attached storage) Nextiva Master Recorder (with external SCSI and Fibre Channel-attached storage) Nextiva Enterprise Storage Manager (ESM) Server (with external SCSI and Fibre Channelattached storage) Nextiva Master Server Nextiva Surveillance Analytics Server and IVAP Server Nextiva Media Gateway Server Nextiva Recorder Server, Master Recorder, and ESM Server (with External SCSI Attached Storage) This section lists the specifications for the Nextiva Recorder Server, Nextiva Master Recorder, and Nextiva ESM Server with SCSI connection for external storage on the Dell PowerEdge R300 and R410 platforms. The Dell PowerVault MD1000 can be used as an external SCSI storage solution for the Nextiva Recorder Server, Nextiva Master Recorder, and Nextiva ESM Server. For specifications and part numbers, see page 16. Component Dell PowerEdge R300 Specifications (for Nextiva 5.1/6.0) Dell PowerEdge R410 Specifications (for Nextiva 6.1) Processor 3.0 GHz Intel Xeon E3113 2.26 GHz Intel Xeon E5520 Memory 2048 MB 4096 MB Disk 2 x 160 GB SATA disk in RAID 1 2 X 250 GB SATA disk in RAID 1 Internal RAID controller Host bus adaptor PERC 6/i SAS RAID controller, PCI Express, 256 MB cache 2 internal x4 SAS connectors PERC 6/E SAS RAID controller, PCI Express, 256 MB cache 2 external x4 SAS connectors PERC 6/i SAS RAID controller, PCI Express, 256 MB cache 2 internal x4 SAS connectors PERC 6/E SAS RAID controller, PCI Express, 256 MB cache 2 external x4 SAS connectors Network interface card 1000BASE-T Ethernet 1000BASE-T Ethernet Verint Video Intelligence Solutions 11

Part Numbers for the Nextiva Recorder Server, Master Recorder, and ESM Server (with External SCSI Attached Storage) The following table lists the part numbers for the Nextiva Recorder Server, Nextiva Master Recorder, and Nextiva ESM Server with SCSI connection for external storage on the Verint-supplied Dell PowerEdge R300 and R410 platforms: Nextiva Release Level Description Verint Part Number 6.1 Nextiva Master Recorder with SCSI connection NEX-6.1-MR-DSCSI Nextiva Recorder Server with SCSI connection Nextiva ESM Server with SCSI connection NEX-6.1-RE-DSCSI NEX-6.1-ESM-DSCSI 6.0 Nextiva Master Recorder with SCSI connection NEX-6.0-MR-DSCSI Nextiva Recorder Server with SCSI connection Nextiva ESM Server with SCSI connection NEX-6.0-RE-DSCSI NEX-6.0-ESM-DSCSI 5.1 Nextiva Master Recorder with SCSI connection NEX-5.1-MR-DSCSI Nextiva Recorder Server with SCSI connection Nextiva ESM Server with SCSI connection NEX-5.1-RE-DSCSI NEX-5.1-ESM-DSCSI Nextiva Recorder Server, Master Recorder, and ESM Server (with External Fibre Channel Attached Storage) This section lists the specifications for the Nextiva Recorder Server, Nextiva Master Recorder, and Nextiva ESM Server with Fibre Channel connection for external storage on the Dell PowerEdge R300 and R410 platforms. The Nexsan SataBeast storage solution can be implemented as external Fibre Channel storage for the Nextiva Recorder Server, Nextiva Master Recorder, and Nextiva ESM Server. For specifications and part numbers, see page 17. Component Dell PowerEdge R300 Specifications (for Nextiva 5.1/6.0) Dell PowerEdge R410 Specifications (for Nextiva 6.1) Processor 3.0 GHz Intel Xeon E3113 2.26 GHz Intel Xeon E5520 Memory 2048 MB 2048 MB Disk 2 x 160 GB SATA disk in RAID 1 2 X 250 GB SATA disk in RAID 1 Internal RAID controller Host bus adaptor PERC 6/iR SAS RAID Controller QLE2460/QLE2462 4 Gb Fibre Channel to PCI Express PERC 6/iR SAS RAID Controller QLE2460/QLE2462 4 Gb Fibre Channel to PCI Express Network interface card 1000BASE-T Ethernet 1000BASE-T Ethernet Verint Video Intelligence Solutions 12

Part Numbers for the Nextiva Recorder Server, Master Recorder, and ESM Server (with External Fibre Channel Attached Storage) The following table lists the part numbers for the Nextiva Recorder Server, Nextiva Master Recorder, and Nextiva ESM Server with Fibre Channel connection for external storage on the Verint-supplied Dell PowerEdge R300 and R410 platforms: Nextiva Release Level Description Verint Part Number 6.1 Nextiva Master Recorder with Fibre Channel connection NEX-6.1-MR-DFIBER Nextiva Master Recorder with 2 Fibre Channel connections Nextiva Recorder Server with Fibre Channel connection Nextiva Recorder Server with 2 Fibre Channel connections Nextiva ESM Server with Fibre Channel connection Nextiva ESM Server with 2 Fibre Channel connections NEX-6.1-MR-DFIBER2 NEX-6.1-RE-DFIBER NEX-6.1-RE-DFIBER2 NEX-6.1-ESM-DFIBER NEX-6.1-ESM-DFIBER2 6.0 Nextiva Master Recorder with Fibre Channel connection NEX-6.0-MR-DFIBER Nextiva Master Recorder with 2 Fibre Channel connections Nextiva Recorder Server with Fibre Channel connection Nextiva Recorder Server with 2 Fibre Channel connections Nextiva ESM Server with Fibre Channel connection Nextiva ESM Server with 2 Fibre Channel connections NEX-6.0-MR-DFIBER2 NEX-6.0-RE-DFIBER NEX-6.0-RE-DFIBER2 NEX-6.0-ESM-DFIBER NEX-6.0-ESM-DFIBER2 5.1 Nextiva Master Recorder with Fibre Channel connection NEX-5.1-MR-DFIBER Nextiva Master Recorder with 2 Fibre Channel connections Nextiva Recorder Server with Fibre Channel connection Nextiva Recorder Server with 2 Fibre Channel connections Nextiva ESM Server with Fibre Channel connection Nextiva ESM Server with 2 Fibre Channel connections NEX-5.1-MR-DFIBER2 NEX-5.1-RE-DFIBER NEX-5.1-RE-DFIBER2 NEX-5.1-ESM-DFIBER NEX-5.1-ESM-DFIBER2 Verint Video Intelligence Solutions 13

Nextiva Master Server This section lists the technical specifications for the Nextiva Master Server on the Dell PowerEdge R300 and R410 platforms. Component Dell PowerEdge R300 Specifications (for Nextiva 5.1/6.0) Dell PowerEdge R410 Specifications (for Nextiva 6.1) Processor 3.0 GHz Intel Xeon E3113 2.26 GHz Intel Xeon E5520 Memory 2048 MB 4096 MB Disk 2 x 160 GB SATA disk in RAID 1 4 X 160 GB SATA disk in RAID 1 Internal RAID controller PERC 6/i SAS RAID controller, PCI Express, 256 MB cache 2 internal x4 SAS connectors PERC 6/i SAS RAID controller, PCI Express, 256 MB cache 2 internal x4 SAS connectors Network interface card 1000BASE-T Ethernet 1000BASE-T Ethernet Part Numbers for the Nextiva Master Server The following table lists the part numbers for the Nextiva Master Server on the Verint-supplied Dell PowerEdge R300 and R410 server platforms: Nextiva Release Level Description Verint Part Number 6.1 Nextiva Master Server NEX-6.1-MS-DELL 6.0 Nextiva Master Server NEX-6.0-MS-DELL 5.1 Nextiva Master Server NEX-5.1-MS-DELL Nextiva Surveillance Analytics and IVAP Servers This section lists the technical specifications for the Nextiva Surveillance Analytics and Nextiva IVAP Servers on the Dell PowerEdge R300 and R410 platforms. Component Dell PowerEdge R300 Specifications (for Nextiva 5.1/6.0) Dell PowerEdge R410 Specifications (for Nextiva 6.1) Processor 2.33 GHz Intel Xeon L5410 2.26 GHz Intel Xeon E5520 Memory 4096 MB 4096 MB Disk 2 X 500 GB SATA disk in RAID 1 2 X 250 GB SATA disk in RAID 1 Internal RAID controller PERC 6/i SAS RAID controller, PCI Express, 256 MB cache 2 internal x4 SAS connectors PERC 6/i SAS RAID controller, PCI Express, 256 MB cache 2 internal x4 SAS connectors Network interface card 1000BASE-T Ethernet 1000BASE-T Ethernet Verint Video Intelligence Solutions 14

Part Numbers for the Nextiva Surveillance Analytics and IVAP Servers The following table lists the part numbers for the Nextiva Surveillance Analytics and Nextiva IVAP Servers on the Verint-supplied Dell PowerEdge R300 and R410 platforms: Nextiva Release Level Description Verint Part Number 6.1 Nextiva Surveillance Analytics Server and Nextiva Video Analytics Processor (IVAP) Server NEX-6.1-IVAP-DSR 6.0 Nextiva Surveillance Analytics Server and Nextiva Video Analytics Processor (IVAP) Server NEX-6.0-IVAP-DSR 5.1 Nextiva Surveillance Analytics Server and Nextiva Video Analytics Processor (IVAP) Server NEX-5.1-IVAP-DSR Nextiva Media Gateway Server This section lists the technical specifications for the Nextiva Media Gateway Server on the Dell PowerEdge R300 and R410 platforms. Component Dell PowerEdge R300 Specifications (for Nextiva 5.1/6.0) Dell PowerEdge R410 Specifications (for Nextiva 6.1) Processor 3.0 GHz Intel Xeon E3113 2.26 GHz Intel Xeon E5520 Memory 2048 MB 2048 MB Disk 2 x 160 GB SATA disk in RAID 1 2 X 250 GB SATA disk in RAID 1 Internal RAID controller PERC 6/iR SAS RAID Controller PERC 6/iR SAS RAID Controller Network interface card 1000BASE-T Ethernet 1000BASE-T Ethernet Part Numbers for the Nextiva Media Gateway Server The following table lists the part numbers for the Nextiva Media Gateway Server on the Verint-supplied Dell PowerEdge R300 and R410 platforms: Nextiva Release Level Description Verint Part Number 6.1 Nextiva Media Gateway Server (Site or stream connections not included) NEX-6.1-TRSCOD-DSRV 6.0 Nextiva Media Gateway Server (Site or stream connections not included) NEX-6.0-TRSCOD-DSRV Verint Video Intelligence Solutions 15

4 External Storage This section contains technical specifications and part numbers for the following Verint-supplied external storage devices: Dell PowerVault MD1000 Nexsan SataBeast Dell PowerVault MD1000 The Dell PowerVault MD1000 is used as a SCSI connection for external storage. It is certified for Nextiva with the following configuration: Nextiva Release Level Description Drive Specifications Verint Part Number 6.1 Dell PowerVault MD1000 SCSI external storage with 15 drive bays 8 x 1.0 TB SATA 1 drive used for RAID parity 12 x 1.0 TB SATA 1 drive used for RAID parity 15 X 1.0 TB SATA 1 drive used for RAID parity NEX-6.1-DPVEXT-7.0TB NEX-6.1-DPVEXT-11.0TB NEX-6.1-DPVEXT-14.0TB 6.0 Dell PowerVault MD1000 SCSI external storage 8 x 750 GB SATA 1 drive used for RAID parity 12 x 750 GB SATA 1 drive used for RAID parity 15 X 750 GB SATA 1 drive used for RAID parity NEX-6.0-DPVEXT-5.25TB NEX-6.0-DPVEXT-8.25TB NEX-6.0-DPVEXT-10.5TB 5.1 Dell PowerVault MD1000 SCSI external storage 8 x 750 GB RAID 5 1 drive used for RAID parity 12 x 750 GB RAID 5 1 drive used for RAID parity 15 X 750 GB RAID 5 1 drive used for RAID parity NEX-5.1-DPVEXT-5.25TB NEX-5.1-DPVEXT-8.25TB NEX-5.1-DPVEXT-10.5TB Verint Video Intelligence Solutions 16

Nexsan SataBeast The Nexsan SataBeast is used as the Fibre Channel connection for external storage. It is certified for Nextiva with the following configuration: Nextiva Release Level Description Drive Specifications Verint Part Number 6.1 Nexsan SataBeast Fibre Channel connection 28 x 1.0 TB SATA 1 drive used for hot spare 2 drives used for RAID parity 42 x 1.0 TB SATA 2 drives used for hot spare 4 drives used for RAID parity NEX-6.1-EXSTR-25.0TB NEX-6.1-EXSTR-36.0TB 6.0 Nexsan SataBeast Fibre Channel connection 28 x 750 GB SATA 1 drive used for hot spare 2 drives used for RAID parity 42 x 750 GB SATA 2 drives used for hot spare 4 drives used for RAID parity NEX-6.0-EXSTR-18.75TB NEX-6.0-EXSTR-27TB 5.1 Nexsan SataBeast Fibre Channel connection 28 x 750 GB RAID 5 1 drive used for hot spare 2 drives used for RAID parity 42 x 750 GB RAID 5 2 drives used for hot spare 4 drives used for RAID parity 42 x 1.0 TB RAID 5 2 drives used for hot spare 4 drives used for RAID parity NEX-5.1-EXSTR-18.75TB NEX-5.1-EXSTR-27TB NEX-5.1-EXSTR-36.0TB Verint Video Intelligence Solutions 17

5 Ethernet Switches If multicast is required for your network, please note that most out-of-the-box Ethernet switches are not configured to properly support it. When choosing an Ethernet switch, it is important to ensure the switch can support IGMP (Internet Group Multicast Protocol) snooping version 2. It is also important to remember that an IGMP querier is needed in each virtual local area network (VLAN). IGMP Query is normally supported by routers or high-end layer-3 switches. IGMP is a session-layer (IP, layer-3) protocol used to establish membership in a multicast group. There are three versions of IGMP, with version 2 being the most widely used. Nextiva supports version 2. Using multicast in an improperly-configured network or over a network that does not support multicast will result in a multicast flood. Flooding can also occur if the IGMP querier loses power or drops its network connection. Multicast traffic is blocked by most firewalls, VPN, and Internet routers; therefore multicast is generally applicable only to private networks. Multicast can be routed across multiple subnets using multicast routers supporting PIM (Protocol Independent Multicast). Nextiva supports both. PIM is the recommended multicast routing protocol. Verint-Supplied Dell Ethernet Switches Nextiva supports the following Dell Ethernet switches: Description Dell PowerConnect 2808: 8 RJ-45 10/100 ports managed multicast switch Dell PowerConnect 3524: 24 RJ-45 10/100 ports managed multicast switch Dell PowerConnect 5424: 24 RJ-45 10/100/1000 ports managed multicast switch Dell PowerConnect 5448: 48 RJ-45 10/100/1000 ports managed multicast switch Dell PowerConnect 3524P: 24 PoE RJ-45 10/100 ports managed multicast switch Dell PowerConnect 3548P: 48 PoE RJ-45 10/100 ports managed multicast switch Verint Part Number NEX-8-DSW NEX-24-DSWM NEX-24-DSWM-1GE NEX-48-DSWM-1GE NEX-24-DSWM-PoE NEX-48-DSWM-PoE Verint Video Intelligence Solutions 18

Verint-Supplied QLogic Switch Kit Nextiva supports the following QLogic switch kit: Description QLogic SANbox SB1403: 8-port 2 Gb Fibre Channel switch kit, includes cables, SFPS, installation, and configuration Verint Part Number 70-406-1063 Note: This fibre switch is not approved for EMC SAN use. Please contact EMC for a list of their supported fibre switches. Verint Video Intelligence Solutions 19

AMERICAS EMEA APAC info@verint.com marketing.emea@verint.com marketing.apac@verint.com www.verint.com/videosolutions www.verint.com/videosolutions www.verint.com/videosolutions