Krontek KT2050 Network Clock Controller

Similar documents
Krontek KT2010 Dual Circuit Krontek Signal Controller

KRONTEK KT4000 NETWORK MASTER CLOCK

Krontek KT160 Digital Clock

Krontek World Clock. Operators Manual. Krontek World Clock Rev

SIMREX Corporation Your Trusted Wireless Solution Provider

Any offsets needing less or more than 1 hr will need special programming (call our tech support). Entering Mode Programming. Exiting Programming

WiFi Precision Clocks. Installation and Operation Manual * Legacy Edition *

PoE Digital Clock. PoE Digital Clock Installation and User Guide

SNMP Web Management. User s Manual

WiFi Digital Clock. * Installation and Operation Manual * * For Clocks with Serial Numbers beginning with 'B' *

Nortel Secure Router 2330/4134 Commissioning. Release: 10.2 Document Revision: NN

Model IMP-22G2,H Low Cost Slave Clock Impulser Converts your slave clock to a working timepiece without modifying its original mechanism.

DGS-1510 Series Gigabit Ethernet SmartPro Switch Web UI Reference Guide. Figure 3-1 Device Information window

5. System. Device Information

Industrial Serial Device Server

JNIOR Series 3 A Network I/O Resource Utilizing the JAVA Platform Getting Started Manual Release 3.3 NOTE: JNIOR OS 3.4 or greater required

Installation and User Guide. Version 0.6

2400 Series. Installation & Operations Manual. 42 Central Drive Farmingdale, NY

PoE DotMatrix Clock. * Installation and Operation Manual *

Atomic Time Manager 400 Product Documentation

Installation and User Guide. Version 1.1

Commissioning Avaya Secure Router 2330/4134

Technical specification Marine Master Clock

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2

PoE Digital Clock. * Installation and Operation Manual * * For Clocks with Serial Numbers beginning with 'B' *

RC001-NMS1 (REV.C) User Manual

GPS NTP Time Server for Intranet Networks DIN RAIL Version

QUICK START GUIDE. Your Power Solutions Partner

Ethernet Interface Module

IV-18 (ИВ-18) VFD Tube Clock. Instructions. Contents. v Energy Pillar

TOP Server V5 to MicroLogix Using DNP3 Ethernet Driver

GateKeeperXpress Standalone or Networked Proximity Card Controller

ETC II Network Communicator Installation and Operation Manual

ROCKETLINX ES8508 ES8508 ES8508F ES8508-XT ES8508F-XT QUICK INSTALLATION GUIDE

R ev D. Daylight Saving Time Configuration Guide for an RF Network

TIME SERVER NETSILON. Quick start.

Startup Guide. NetAXS-123. Version 5.2

EY-WS 500: Web server for moduweb Vision and moduweb500 BACnet networks

epowerswitch 1G R2 User guide Version

MINLEON NETWORK EFFECTS CONTROLLER SYSTEM (NEC) INSTRUCTION MANUAL

Installing the Cisco Unified Videoconferencing 3545 MCU

1 DIVAR 3000/5000 firmware version (date )

Using the Startup Wizard

AP41 / AP81 SERIES TIME SWITCHES

SC1000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

LiteKeeper 4. Stand Alone Lighting Control Panel Technical Specifications PART 1. GENERAL 1.01 INTRODUCTION 1.02 DESCRIPTION OF WORK

Managing System of Standalone EAP

JNIOR Series 4 A Network I/O Resource Utilizing the JAVA Platform Getting Started Manual Release 2.0 NOTE: JANOS OS 1.1 or greater required

Click Save to return to the main Setup screen.

MB40 & MB45 MODBUS TCP/IP Gateway Handbook

Turn Up a Node. Before You Begin CHAPTER

3 Administrative Tasks

MIU-1000 v. Revised: 4/20/2009. Copyright 2008, Traf-SYS, Inc.

Ethernet communicator E14 USER MANUAL July, 2018

TM1000A. GPS Based Network Time Server. Installation and Operation Manual

Contents. System Properties...5

Installation and Operation Manual. Power over Ethernet (PoE) Clocks

ETM350C & ETM450C User Manual

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

Interface Technology Group, Inc.

MODBUS/TCP TO SIEMENS G110/G120/MM440 APPLICATION

USB 2.0 Print Server. User s Manual. Rev. 01 (Jan, 2004) Made In Taiwan

Available Commands CHAPTER

2.4GHz Digital Wireless 7 LCD Surveillance Kit

VTC. 200/300 Series. VTC elock controller. VTC elock Instructions. Network VTC elock has three components:

SymSYNC TM User s Guide

U-FLASH Setup Guide U-FLASH.

ETC II Modbus Communications Protocol Reference Guide

Innovative Electronics for a Changing World INDEX

UPS COMMUNICATION Web Card

DSL-G624T. Wireless ADSL Router. If any of the above items is missing, please contact your reseller. This product can be set up using any

Installation and Operation Manual

ANSEL FXS / 1 PSTN. VoIP Telephone Adaptor. User Manual V1.10

Table of Contents. NBC User's Manual

EC-11 Ethernet Converter

USING THE XPERT2 / 9210B ON A TCP/IP NETWORK

Software Update Release Notes: NetClock ECN 2770 NetClock version Release Notes

SPRITE. Operations manual. VRM10 Digital Audio Variometer. Recorded alarm messages including undercarriage warning

Upgrading the Server Software

TR610 User's Manual GIGA-TMS Inc.

Luminato. Quick Start Manual. Teleste Corporation. Luminato First Time Installation. SW version 1.1.2

512 channels WIFI-DMX Interface

6-Channel Monitor. Installation and Operation Manual

Version 3.0 May 2007 CYCLONE TIMING MODULE USER GUIDE

NETWORK TIME PROTOCOL ANALOG CLOCK

TG Technical specifications

SCAN LEARN MORE. iw4 Start Guide Visit our website for additional help and how-to videos

Version 1.0c May 6, 2010 ATK3

Developing Networked Data Acquisition Systems with NI-DAQ

Auto Upgrade. Auto upgrade - Network Method

WISP Setup Guide for TP-Link TL-WR841N 300 Mbps Wireless N Router AARP Foundation Tax-Aide Colorado Technology Specialist

WebNet HandPunch User Guide for Attendance on Demand. (Download at

HWg-STE HWg-STE PoE MANUAL

ZyWALL 10W. Internet Security Gateway. Quick Start Guide Version 3.62 December 2003

Bose ControlSpace Designer Software. User Guide

PSL Power Standards Lab 2020 Challenger Drive Alameda, CA USA TEL FAX

CP30/G30/MC31 Firmware Version 3100 Known Issues

Power Switch Cabinet 4-Port New Generation

Please take serious note of the following warnings:

SIMATIC S7-400, CPU KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.

Transcription:

Krontek KT2050 Network Clock Controller Slave Clock Controller - 1 - Rev 1.2 24-Nov-2008

Table of contents INTRODUCTION... 3 TIME CORRECTION FORMATS... 4 Communicating with the Controller... 5 Main Menu... 6 1 - Set Time Server IP address:... 6 2 - Set Time Server poll period:... 7 3 - Set Time Zone Offset... 7 4 - Set Daylight Savings... 8 5 - Set Time and Date:... 8 6 - Set Slave Correction Format:... 9 7 - Set Controller IP address:... 9 Technical Specifications... 11 Slave Clock Controller - 2 - Rev 1.2 24-Nov-2008

INTRODUCTION The Krontek KT2050 Slave Clock Controller converts network (SNTP) time to the electrical protocols required by analog and digital slave clocks (supported clock protocols are listed on the following page). The Controller has an autosensing 10/100Mbit Ethernet Interface and can drive a clock load of up to 750mA at 24VDC. The Controller operates stand alone, that is, it does not require any external support for normal operation, such as a PC or other device that can be switched off inadvertently. During a network failure the Controller will continue to operate from its internal time base. The Controller derives its time from the network via an SNTP Server. SNTP time can be sourced externally from the Internet or from local timeservers such as the Krontek KT2000 GPS Timeserver. The Controller contains a battery backed Real Time Clock that will maintain the time for a period of 4 days in the event of a power failure. Lost time is accumulated and slave clocks are restored to the correct time when power is restored. The Controller can be programmed from any PC on the network via a telnet session. Passcode protection is provided to prevent unauthorized access. Daylight saving is fully automated and will adjust the slave clocks to the appropriate time as required. Slave Clock Controller - 3 - Rev 1.2 24-Nov-2008

TIME CORRECTION FORMATS This page is included to provide a brief description of the various time correction formats. The Controller supports all popular correction formats used by Simplex, Cincinnati, Bodet and many others. If you are unsure of the type of clocks on you have please contact Krontek or one of our distributors for further advice. Note that any correction format not described here can be incorporated into the controller as required. Sync Wired: This format consists of an 8 or 12 second control pulse indicating an hourly or twelve hourly correction. The Controller provides the option of a correction every hour or every twelve hours. SR2: This is a corrective minute impulse format. The Controller provides a pulse each minute, at the 50 th minute the polarity of the pulse is reversed and any clock that is less than 10 minutes ahead of time will stop operating. At the 59 th minute a series of rapid pulses are produced that will synchronize all clocks to the correct minute. Reverse Polarity: This format consists of an impulse each minute alternating in polarity. There is no time correction. Standard BCD: This format provides an hour, minute and second data stream and can be selected for 50 or 60 bits per second. Extended BCD: This format provides an hour, minute, second, day, month and year data stream at 128 bits per second. D1/D2: This format controls Bodet Tower Clock Movements. Syncroline: This format provides power and data for Krontek s Syncroline range of clocks. Alpha: This format provides the serial correction data for Adaptive Displays Alpha Clocks (requires 6VDC Power Pack). Slave Clock Controller - 4 - Rev 1.2 24-Nov-2008

Communicating with the Controller Before you can communicate with the Controller you must know its IP address. The Controller comes pre configured with an IP address of 192.168.0.128 and responds to a telnet session on default port 23. There are three options to enable communications with the Client: 1. Your network is already compatible, i.e. 192.168.0.xxx 2. Configure a PC to a compatible IP address, i.e. 192.168.0.50, and use a network crossover cable. 3. Use the DeviceDetector utility. In reference to point 3. Download the utility DeviceDetector.zip from our website.au/downloads/devicedetector.zip to your PC and unzip it. When you launch the program it will scan the network for Krontek Network Time devices (irrespective of their IP address) and list them. Click on the device you wish to configure. The IP and Subnet Mask address will be presented for editing. After you update the settings the Controller will reboot. You will need to run DeviceDetector again to find the Controller and ensure the new address is correct. Once you have set the address you can establish a telnet session using a telnet communications program such as HyperTerminal, HyperTerminal is usually included with your PC operating system. Use windows start -> help -> search and type in HyperTerminal to locate it on your machine. If it is not installed it is available from www.hilgraeve.com. When using HyperTerminal use the TCP/IP connect option, the Controllers IP address and port 23. An alternative to HyperTerminal is to open a DOS command window and type in telnet xxx.xxx.xxx.xxx (where x is the IP address you have assigned the Controller). The Controller uses the default telnet port 23 for the connection. Important: Ensure you disconnect from the telnet session either by closing the terminal window or exiting the Controller menu using 99. Failure to do this will inhibit another session from being opened as only one session can operate at one time. Slave Clock Controller - 5 - Rev 1.2 24-Nov-2008

Main Menu After making the telnet connection you will be presented with the following or similar menu: -- Main Menu -- 1 - Set Time Server IP address 2 - Set Time Server poll period 3 - Set Time Zone Offset 4 - Set Daylight Savings 5 - Set Time & Date 6 - Set Slave Correction Format 7 - Set Controller IP address 8 - Manually Advance Clocks 9 - Display Status 10 - Set/Change Passcode 99 - Exit Select 1 - Set Time Server IP address: Select this to set the IP address of your network Time Server. The Controller will display: Current Time Server address: 192.168.000.070 Change Y/N? If you opt to change you will be prompted with each 3 number field in brackets, you may change it or press enter to skip to the next field. (192)220.(168)150.(000)0.(070) 75 In the above example we changed the address to 220.150.000.075 The Controller will display the new address and ask for confirmation to save it. Slave Clock Controller - 6 - Rev 1.2 24-Nov-2008

2 - Set Time Server poll period: The Controller displays: Current Time Server poll period 1 hours Enter new period 0-48 hrs or <CR> to exit This is the time period between calls to the network Time Server. Select a period of 0 to 48 hours. Default is 0. Zero will disable the polls to the Time Server and allow the time and date to be set manually. This menu item has the additional feature of force polling the timeserver, you do not have to enter a time just press Enter <CR> to exit. This provides a facility to force an update to the Controller s time and test the network time server (see Display Status for poll results). The poll timer is restarted each time this menu item is executed. 3 - Set Time Zone Offset The Controller displays: Current Time Zone Offset: 10.0 hours Enter offset -13 to +13 or <CR> to exit? Time Servers provide time based on UTC (also referred to as GMT or Zulu), that is, the time at the Earths zero meridian. Therefore you must add or subtract the time of the time zone you are in to set the local time. Note: Use standard time - do not use daylight savings time. Enter your time zone offset from UTC. Then the Controller displays: Add half hour Y/N? This allows you to add a further 30 minute offset. For instance Adelaide, Australia is UTC +9.5 hours. Examples: London is 0, Paris is 1, New York is 5, Sydney is +10. The Controller will display the new offset and ask for confirmation to save it. Slave Clock Controller - 7 - Rev 1.2 24-Nov-2008

4 - Set Daylight Savings Daylight Saving options: Select: 0 to Disable, 1 to Define your own Or choose from the following table: --------- Start --------- ---------- End ---------- ------ Region ----- 2 - Last Sun in Oct at 02:00 Last Sun in Mar at 03:00 AUSTRALIA EASTERN 3 - First Sun in Oct at 02:00 Last Sun in Mar at 03:00 AUSTRALIA TASMAINIA 4 - Last Sun in Mar at 02:00 Last Sun in Oct at 03:00 EUROPE 5 - First Sun in Oct at 02:00 3rd Sun in Mar at 03:00 NEW ZEALAND 6 - Last Sun in Mar at 02:00 Last Sun in Oct at 01:00 UK 7 - First Sun in Apr at 02:00 Last Sun in Oct at 02:00 USA 8-2nd Sun in Mar at 02:00 First Sun in Nov at 02:00 USA NEW Current Settings: Starts: Last Sun in Oct at 02:00 Ends : Last Sun in Mar at 03:00 Region: AUSTRALIA EASTERN Enter option or <CR> to exit If you require daylight saving then either choose an entry from the table, or enter 1 and The Controller will allow you to configure a unique daylight saving period not available from the table just follow the prompts. Selecting 0 will disable daylight saving. 5 - Set Time and Date: The time and date can only be set if the timeserver poll period is disabled (set to 0). Note: The ability to set the time and date is to enable the functional testing of the time and calendar schedules. It is not recommended that the Controller operate in this mode over an extended period as the internal clock relies on a timeserver for accuracy. The Controller displays: Enter time as HHMMSS in 24hr format or <cr> to skip Example: 2:43:35pm is entered as 144335 Enter date as DDMMYY or <cr> to skip Example: 2 nd Jan 2005 is entered as 020105 Press enter to return to the Setup Menu Slave Clock Controller - 8 - Rev 1.2 24-Nov-2008

6 - Set Slave Correction Format: This option allows you to select the clock correction format you require see page 4 for details. Setting the format to 0 will disable the output. 7 - Set Controller IP address: Select this to set the IP address of the Controller. This is an alternative to using the DeviceDetector utility. Be warned, if you change anything but the last 3 digits you will not be able to communicate with the Controller again unless your PC is set to the same host IP settings. The Controller will display: Current Time Server address: 192.168.000.128 Change Y/N? If you opt to change you will be prompted with each 3 number field in brackets, you may change it or press enter to skip to the next field. (192).(168).(000).(128) 220 In the above example we changed the last field to 220 The Controller will display the new address and ask for confirmation to save it. Note: If you change the IP address the Controller will reboot and you will need to re establish a connection using the new IP address. 8 Manually Advance Clocks: This option allows you to set the time of the slave clocks. The resolution or accuracy to which you can set them to depends on the correction format. Some formats will only allow manual correction to within the hour. Slave Clock Controller - 9 - Rev 1.2 24-Nov-2008

9 Display Status: This option displays the various settings selected. In the case of Syncroline clocks it will also display the clock load on the controller. This should be kept to 90% or less for long term operation. 10 Set/Change Passcode: This option allows you to set the passcode to restrict unauthorized access to the controller. Four characters are required. Alpha (A-Z) and numeric (0-9) characters are accepted. Lower case characters are internally converted to upper case. A code of four zeros (0000) will disable passcode checking. Slave Clock Controller - 10 - Rev 1.2 24-Nov-2008

Technical Specifications Accuracy: Dependant on timeserver (generally within 20ms of UTC) Ethernet: Auto-sensing 10/100Mbit, RJ45 Interface Ethernet Connection Indicators: Orange 10Mbit, Green 100Mbit SNTP Protocol: Compliant with RFC 2030 Telnet Port: 23 Power Led: On when power is applied Active Led: Flashes once per second when time base is operational Power Supply Requirements: 24 volts DC, 2A Output voltage: 24VDC @ 1.6A Internal Clock: 15 day battery backup, ±2 mins/year accuracy Dimensions: Length 87mm, Width 57mm, Height 27mm Slave Clock Controller - 11 - Rev 1.2 24-Nov-2008