Infilex GD Multipurpose Data Gathering Panel Model WY5310

Similar documents
Infilex GC Multipurpose Controller Model WY5311

Infilex AC AHU Controller Model WY5317C

Infilex GC Multipurpose Controller Model WY5111

SCS (System Core Server) Model BCY44100M

Intelligent Component Series Direct Coupled Damper Actuator Model MY8040A

Infilex AC. Air Handling Unit Controller for NC-bus Communication. Specifications/Instructions. General. Features AB-6438

I/O Modules, User Terminal Module, and SAnet Interface Module

PARAMATRIX -III Chiller Controller Model WY7400T

PARAMATRIX 4 Chiller Controller

BACnet Controller for General-purpose Building Applications

Infilex VC Variable Air Volume Controller with Actuator for SC-bus Communication

(Thermoplate (Auxiliary part))

Infilex FC. Fan Coil Unit Controller for SC-bus Communication. Specifications/Instructions. Overview. Features AB-6567

Infilex VC Variable Air Volume Controller with Actuator for BACnet MS/TP Communication

Advanced Remote I/O Module

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Operating instructions. Switching amplifier DN0210 DN / / 2015

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

MODEL: R2K-1 SEN TRONIC AG. R2K Series

LON Module for Variable Speed Drive

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

INTELLIGENT SERVER. Model: BMS-LSV6E

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

Product and functional description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

4170 POS System Installation Guide

Operating instructions. Speed monitor D / / 2014

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Infilex FC Fan Coil Unit Controller

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

PXR11 PXR12. System controllers DESIGO PX

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

Extension module for lighting control

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Modicon Premium PLCs TSX CSY 84 / 85 / 164

INSTALLATION INSTRUCTIONS

MC 11 EB-2 Power supply cabinet with external bus, AC version

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Type ME43. Quickstart

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

BACnet/IP Web Interface

F1000 User's Manual. (Version: V1.01)

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

INSTALLATION MANUAL. Gateway option box EKLONPG EKBNPG

Hard Disk Unit for PC CPU Module Compatible with MELSEC-Q Series PPC-HDD(MS)A User s Guide

User Manual. MS657208X Industrial Gigabit Ethernet Switch 8x 10/100/1000Base-T

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

PS/IO Circuit Board Retrofit

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Green Engineering Pty Ltd

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Content. Product Description

KIEN2204S Industrial Ethernet Switch Hardware Installation Manual

Conductive Level Controller

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

DC I/O Conversion Module

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

Package Contents. GP Options (Made by Digital)

Network Camera. Quick Guide DC-B1203X. Powered by

DC I/O Conversion Module FA-TB32XY

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

Preface. Copyright 1997, Digital Electronics Corporation MS-DOS and Windows 95 are registered trademarks of the Microsoft Corporation.

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

LOCAL DISPLAY UNIT (LDU)

Language of the manual

LTEC Heat Pump DDC Controller

PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10)

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

User's Guide. Model W 3-in-1 Switching DC Power Supply

HEC. General Operating, Maintenance and Installation Manual

FX2NC-ENET-ADP Ethernet adapter USER'S MANUAL

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

TOSLINE-S20 Active Star Coupler Instruction Manual

IQ21x Series Controllers

EX-RC1 Remote I/O Adapter

MultiVOIP SIP Gateways

TAC Xenta 301. Controller, Freely Programmable

ACCESS 9340/9360 Meter Input/Output Module

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

Transcription:

Specifications/Instructions Infilex GD Multipurpose Data Gathering Panel Model WY5310 General Infilex GD (Infilex: named for Infinity and Flexible ) Model WY5310 is a multipurpose terminal data transfer device designed to collect the data about various types of building equipment, to monitor the equipment status, and to control the equipment operation. Infilex GD can be operated with Operator Panel. Besides, Infilex GD can communicate with BMS (building management system) Yamatake s savic-net FX via LonTalk protocol. By sending the operation status to the center unit (client PC) and by controlling the operation based on the commands sent from the main control unit, the integrated control of the entire building can be executed. Infilex GD consists of a basic unit and connectable I/O modules (and a user interface module). The number and types of the modules can be flexibly changed corresponding to the control and management to fit in various applications. Features Compact design: Small size body allows free installation in a desired place. Various input/output (I/O) configurations: Input and output types can be selected, and the number of points to be mounted can be increased or decreased corresponding to the application. User interface module (Operator Panel): Operator Panel (panel mount type/integral type) connected to Infilex GD allows you, without changing the settings from the BMS center unit, to change the Infilex GD settings. Autonomous distributed control: Even if a trouble occurs in the BMS, the backup operation is performed individually to distribute potential risks caused by malfunction of the system. 2 types of installation: Infilex GD can be mounted on a DIN rail or directly with screws. Easy wiring: Modular connector is used for the wiring of communication to facilitate wiring. LONMARK certified product: Infilex GD is LONMARK certified and thus interoperable integrated in the LONWORKS system. CE Marking certified product: Infilex GD Model WY5310W (100-240 V AC power type) conforms to all the applicable standards of CE Marking. Yamatake s Infilex series controllers: Infilex is named for Infinity and Flexible. 1

Safety Instructions Please read instructions carefully and use the product as specified in this manual. Be sure to keep this manual near by for ready reference. Usage Restrictions This product is targeted for general air conditioning. Do not use this product in a situation where human life may be affected. If this product is used in a clean room or a place where reliability or control accuracy is particularly required, please contact Yamatake s sales representative. Yamatake Corporation will not bear any responsibility for the results produced by the operators. WARNING DANGER: To prevent the risk of severe or fatal electrical shock, always disconnect power source and product power supply before performing any wiring. Do not disassemble the product. Electrical shock or equipment damage may result. Make sure all the wires are tightly connected. Burn injury due to heat generation or equipment malfunction may result. Be sure to ground. Improper grounding may cause electrical shock or fire due to equipment damages. CAUTION Installation must be performed by qualified personnel in accordance with all applicable safety standards. Installation must be carried out according to the operating conditions specified in this manual to prevent equipment damages. All wiring must comply with local codes of indoor wiring and electric installation rules. Do not plug in or out the I/O (input/output) module with the product power turned on to prevent equipment damages. Use crimp terminals with insulation for electric wires connected to the screw terminals. Connect cables to the power source with terminals or the like for permanent connection. Do not detach the terminal cover except when connecting or disconnecting wires. After connecting or disconnecting them, be sure to reattach the terminal cover. Make sure that the terminals and wires are not current-carrying when attaching or detaching the terminal cover. If more than the rated power supply voltage is applied, product replacement is required for safety. Do not peel off the label with marked on. Install this product in a location out of reach of unauthorized people. (e.g. Inside of the control panel cabinet) Lightning protection based on regional characteristics and building structure is needed in order to minimize lightning damages. Select the rated surge absorber appropriate for the voltage, current, and capacity of the circuit to be used. After completing the wiring, be sure to peel off the protective sheet. Do not block the vent holes of the product to prevent equipment damages. Wiring must be installed with cable ties so as not to hide the LED, battery holder, and the indication tag. Before replacing the product, make sure that the product power supply is disconnected. After mounting the product on DIN rail, make sure that the holding parts of all the modules are properly fixed with their whole parts lifted. The product may drop from the DIN rail and be damaged due to improper mounting. Dispose of the lithium battery in accordance with the local regulations. Do not incinerate this product for waste disposal (the housing produces toxic gas when incinerated). Do not recycle all or part of this product, either. 2

Trademark information: Infilex, Neopanel, PARAMATRIX and savic-net are trademarks or registered trademarks of Yamatake Corporation in Japan or in other countries. BACnet is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). CompactFlash is a U.S. registered trademark of SanDisk Corporation. LonTalk is a trademark of Echelon Corporation registered in the United States and other countries. System Configurations Infilex GD integrated into BMS: savic-net FX MIS SMS DSS Client PC (with Web browser) BACnet IP SCS LC-bus (LonTalk protocol) Infilex GD Model WY5310 Infilex GC Model WY5311 Operator Panel Model QY5100W/RY5001Q DSS: Data Storage Server LC-bus: LonTalk Protocol Controller Bus LS-bus: LonTalk Protocol Sub-controller Bus MIS: Management Integration Server PMX-III: PARAMATRIX -III SC-bus: Sub Controller bus SCS: System Core Server SMS: System Management Server Infilex AC Model WY5317C Infilex ZM Model WY5322 LS-bus (LonTalk protocol) PMX-III Model WY7400 Infilex SC Model WY5307 Infilex FC Model WY5305 Infilex VC Model WY5306 Neopanel (Digital user terminal) Neopanel (Digital user terminal) Temperature sensor Figure 1. System configuration example of BMS-integrated Infilex GD Notes: MIS may be used instead of SMS and DSS for your system. Note that MIS cannot be mixed with SMS or DSS in the same system. On 1 channel of LC-bus (2 lines for 1 channel), max. 50 remote units (also called controllers ) can be connected. For Infilex ZM, however, max. 10 units can be connected on LC-bus (5 units per 1 line, 2 lines for 1 channel). Max. wiring length of LC-bus (2 lines for 1 channel) is 900 m. On LS-bus, max. 50 remote units (also called sub-controllers ) can be connected. Max. wiring length of LS-bus is 900 m. Model Numbers Model number WY5310 C W Description Base model number 24 V AC power 100 V AC to 240 V AC power (CE Marking certified) 0000 Fixed Notes: For user I/O modules and user interface modules (UT module and integral type Operator Panel) to be combined with Infilex GD Model WY5310, separate order is required. Regarding I/O modules user interface modules to be combined with Model WY5310, refer to AB-6527 Specifications/Instructions of Model RY50XX. 3

Parts for Installation For details regarding Infilex GD installation, refer to Installation manual of the Infilex series controllers Part number Description 83165861-001 Screw tab 83104567-001 DIN rail mounting bracket Note: For mounting Infilex GD, either the screw tab (for screw mounting) or the DIN rail mounting bracket (for DIN rail mounting) is required. Be sure to separately order depending on your mounting type. Specifications Basic specifications Power supply Environmental conditions LED indication Power failure backup Communications Item Rated operating conditions Transport/storage conditions Operation Specification Rated voltage 24 V AC, 50 Hz/60 Hz 100 V AC to 240 V AC, 50 Hz/60 Hz Allowable voltage 20.4 V AC to 27.6 V AC, range 50 Hz/60 Hz 85 V AC to 264 V AC, 50 Hz/60 Hz Power shutdown detection 19.2 V AC or less 80 V AC or less Power consumption 40 VA Ambient temperature 0 C to 50 C Ambient humidity 10 %RH to 90 %RH (non-condensing) Altitude 2000 m or lower Vibration Max. 3.2 m/s 2 (0.33 G) at 10 Hz to 150 Hz Ambient temperature -20 C to 60 C Ambient humidity 5 %RH to 95 %RH (non-condensing) Vibration for storage Max. 3.2 m/s 2 (0.33 G) at 10 Hz to 150 Hz Vibration for transportation Max. 9.8 m/s 2 (1 G) at 10 Hz to 150 Hz Power supply Green LED ON: Power ON (POWER) Green LED OFF: Power OFF Major failure (ERR1) Red LED ON: Major failure or system restart Red LED OFF: Normal operation Minor failure (ERR2) Red LED ON: Minor failure or system restart Red LED OFF: Normal operation Communication LC-bus TX: Transmit, RX: Receive, SERV: Service LC-bus Weight Material (housing), color Terminal block RAM, RTC* Data file Transmission system Transmission speed Transmission distance Remote units Power supply, ground LC-bus communication Lithium battery backup Non-volatile memory (flash memory) backup LonTalk protocol (TP/FT-10 transceiver) 78 kbps 900 m (for bus topology connection) Max. 50 remote units connectable 400 g Modified PPE, light gray M3 (7.62 mm pitch between terminals) Modular connector Note: Real Time Clock (RTC) is backed up by a lithium battery to ensure accurate clocking while the power is OFF. Wiring specifications Basic unit Item Wiring* 1 Wiring length Condition Power supply* 2 JIS* 3 IV2.0 mm 2 or JIS CVV 2.0 mm 2 or greater Ground* 2 JIS IV 2.0 mm 2 or JIS CVV 2.0 mm 2 or greater Ground resistance: 100 Ω or lower LC-bus EIA/TIA-568 category 5 or over (φ0.5 4 poles) 900 m For bus network topology Notes 1 Pin terminal is not applicable to wiring of Infilex GD. 2 M3 screw terminal block is provided for wiring of power supply and ground. Be sure to crimp the crimp terminals on the wire ends. 3 JIS: Japanese Industrial Standards 4

I/O module Since a quick-fit screwless terminal block is provided on I/O modules, the wires can be connected only by stripping the sheath. Sheath stripped length: 8 mm (Pin terminal cannot be used.) Item Wiring Wiring length Temperature input JIS IV, JIS CVV, KPEV* 100 m 1.25 mm 2 Voltage/Current input JIS IV, JIS CVV, KPEV 100 m 1.25 mm 2 Voltage/Current output JIS IV, JIS CVV, KPEV 100 m 0.9 mm 2, 1.25mm 2 Modutrol motor output JIS IV, JIS CVV, KPEV 100 m 1.25 mm 2 Digital input JIS IV, JIS CVV, KPEV 100 m 0.5 mm 2, 0.75 mm 2, 0.9 mm 2, 1.25 mm 2 Relay output JIS IV, JIS CVV, KPEV 100 m 1.25 mm 2 Remote control relay output JIS IV, JIS CVV, KPEV 1.25 mm 2 100 m Note: KPEV is a wiring standard provided by Furukawa Electric Co., Ltd. Specifications of I/O modules, user interface modules, and Operator Panel For the specifications of I/O modules and user interface modules, refer to Specifications/Instructions of Model RY50XX (AB-6527). For the specifications of Operator Panel (integral type / panel mount type), refer to Specifications/Instructions of Model RY5001Q/QY5100W (AB-6546). Input/Output Terminal Arrangement 24 V AC (Model WY5310C) OR 100-240 V AC (Model WY5310W) 1 2 3 4 CONF. IN OUT RJ-45 modular connector LC-bus Figure 2. Input/output terminal arrangement 5

Dimensions 60 90 140 Figure 3. Dimensions (mm) 6

Parts Identification LED for operating status Power switch S1 switch* Do not press the S1 switch. LED for power ON/OFF Battery holder DIN rail mounting hook Indication tag Figure 4. Parts identification LED indication Data transmitting Data receiving In SERVICE mode Major alarm / initializing Minor alarm / initializing Table 1. Indication and operation of operating status LED LED operation LC-bus TX LED: flashing LC-bus RX LED: flashing LC-bus SERV LED: ON ERR1: ON ERR2: ON Connection of Data Setter for LonTalk Communication Connect the CompactFlash memory type Data Setter (Model QY5111B) for LonTalk communication to LC-bus port or to CONF. port of Infilex GD with the Data Setter adaptor (Part No. DY5301S0000, with separate order required.). For details of the Data Setter adaptor, refer to its Specifications manual. LC-bus (LonTalk Data Setter (For setting Infilex GD and other remote units connected on both Data Setter protocol) adaptor LC-bus and LS-bus: Connect Data Setter with Data Setter adaptor to Model QY5111B Model DY5301S LC-bus port or CONF. port of Infilex GD.) Infilex GD Model WY5310 Infilex GC Model WY5311 Infilex AC Model WY5317 Infilex ZM Model WY5322 LS-bus (LonTalk protocol) IAC Model WY7307 Infilex FC Model WY5305 Infilex VC Model WY5306 Figure 5. Connection example of Data Setter with Data setter adaptor to LC-bus port/conf. port 7

Maintenance (Lithium Battery Replacement) Replace the lithium battery for backup (Part No. 83104934-001) for every 5 years. CAUTION Since the remaining battery capacity cannot be checked by measuring the terminal voltage, be sure to replace the battery every 5 years. Only authorized service personnel is allowed to replace the battery. Do not touch the power supply unit when replacing the battery. Replace the battery with the power ON. Replace the battery every 5 years if the product is always in use (in ON state). If the product has never or hardly been operated (in OFF state) for a year, replace the battery before the product operation. Battery replacement 1) Lithium battery for backup 2) Replace the lithium battery with Infilex GD in ON state. Figure 6. Battery replacement 5) 4) Battery holder 3) Infilex GD basic unit Battery connector 1) Pull out the battery holder using a slotted screwdriver. 2) Disconnect the battery connector and detach the lithium battery from the battery holder. 3) Place a new lithium battery in the battery holder and connect the battery connector to it. 4) Insert the battery holder into the main body. 5) Fill in the date for next replacement (5 years after the replacement) on the indication tag using an oil-based pen. 8

Precautions for Use Do not mount the product under the conditions of high temperature and humidity. Be sure not to drop the product. Be sure to shut down the power (disconnect the wiring between the power supply and the product power terminals) for the wire replacement. Before turning on the power, make sure that wires are correctly connected. Do not connect wires to vacant terminals. Several tens of seconds are required for the product normal operation after the power is turned on. During this time, the ERR1 LED (red) for major alarm lights up temporarily, but this does not indicate an error. Leave at least 35 mm clearance between the top/bottom surfaces of the product and other devices. Peel off the protective sheet on the top surface of the product before turning on the power. (See Fig. 7.) For LONMARK network variables, see AB-6824 LONMARK Functional Profile: Open-Loop Actuator. Protective sheet Battery label on the indication tag Figure 7. Battery label and protective sheet 9

10

11 AB-6581

Specifications are subject to change without notice. Building Systems Company http://www.yamatake.com Rev. 2.0 Apr. 2007 (J: AI-6581 Rev. 1.2) 12 AB-6581 H (W03) Printed in Japan.