Meeting updated ISO/IEC Your professional partner of structured cabling system

Similar documents
OM5 versus OM4 Solution concepts and potential applications WHITEPAPER

ISO/IEC SC25 WG3. Who are they & what can they do for 802.3cg? Alan Flatman. Principal Consultant LAN Technologies.

Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards

Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks

Standards Update. by Paul Kish NORDX/CDT

DC Center Copper Cabling up to 40Gbase-T. Halim Senjaya

History of Standards

Data center applications standards reference guide

PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY

Telegärtner Point of View

Standards Update. Mylaraiah J N, RCDD Member, BICSI India Steering Committee

ISO/IEC TR Guidance on 40GBASE-T T Cabling

Cabling to support ac and beyond. Nate Herring Sr. Product Manager Hubbell Premise Wiring

LAN Standards, News & Trends Update 2017 June 15, 2017

Leaders in the Advancement of Multimode Fiber. Fiber Future and Beyond

Atras Network Communications

Introduction to Key Principles of Telecommunications Cabling

Copper Cabling Standards

(Data Center Networks & Cloud Computing Security)

Wirewerks Datacenters Becoming More Common in Our Workplace, Next Step Solution

PANGEN SYSTEM WARRANTY. Warranty Guide

Optimization and Speed: Two Critical Standards Enabling Next Generation Networks. Stephanie Montgomery, TIA Brett Lane, Panduit

New standards that have led to higher speeds and new cable categories. Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks

The Impact of Internet of Things on Cable Certification

Trends in Data Centre

Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print"

ISO/IEC 11801: (E)

Open System Architecture Selecting the Right Cable and Connectivity for Your Application

1 of 5 12/31/2008 8:41 AM

Data sheet C6 A modul 1 port 180 M AP pure white

CERTIFICATION PLUS SM

Fiber backbone cabling in buildings

Cabling Infrastructure

Choosing MPO Connectors for the Data Center. Ken Hall, RCDD, NTS Data Center Architect CommScope

Migratable cabling in computer centres for all data rates from Mbit/s to 100Gbit/s (DClink)

Fiber Optic Cabling Systems for High Performance Applications

LANmark-7A H i g H - S p e e d C O p p e R S O l u t i O n F O R 4 0 g i g a b i t a p p l i C a t i O n S

High Speed Migration 100G & Beyond

Corrigendum 1 to Amendment 2 1 ISO/IEC ISO/IEC (second edition 2002) Information technology Generic cabling for customer premises

The Cabling Partnership

DATA CENTRE CABLING STANDARDS and NEW TECHNOLOGY OVERVIEW for 2005

Optical Fiber Networks: Industry. and New Options for Networks

THE INTERCONNECTED NETWORK

Highlights: ISO/IEC SC25/WG3 Meeting Madrid: 27 Feb - 01 Mar Customer Premises Cabling -

Physical Layer Part 3

25G System The RJ45 building cabling with future

Industry Standards Activity Overview

Structured Cabling. Campus Network Design & Operations Workshop

E-DAT C6A. The compact connection system of course with Cat.6A

ExtremeSwitching TM. 100Gb Ethernet QSFP28 Transceivers and Cables. Product Overview. Data Sheet. Highlights. 100Gb Ethernet QSFP28 SR4 MMF

Multiplexing (Recap)

9/27/04 cci Cablecom Inc. 1

Structured Cabling Technology and Market Assessment

Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation

Integrating Oracle SuperCluster Engineered Systems with a Data Center s 1 GbE and 10 GbE Networks Using Oracle Switch ES1-24

Cabling Infrastructure for Green Buildings. Dr. Paulo Marin, EE, MSc. Paulo Marin Consultoria Phone: (201)

A Fork in the Road OM5 vs. Single-Mode in the Data Center. Gary Bernstein, Sr. Director, Product Management, Network Solutions

3M Telecommunications. Solutions for Networks. Volition 10G Copper Solutions. Innovation

ncompass High Performance Cabling Systems connect. completely.

Highlights: ISO/IEC SC25/WG3 Meeting Geneva: Sep Customer Premises Cabling -

AMP NETCONNECT XG FIBER SYSTEM

The Impact of Internet of Things (IoT) on Cable Certification

Optical Fiber Premises Standards News & Trends

Classical Ethernet (10 Mbps)

IEEE Ethernet Working Group TIA TR-42 Liaison to IEEE 802.3

Overcoming the Testing Challenges of 40G and Beyond. Eric Farst Channel Sales Manager

Fiber Backbone Cabling in Buildings

Dr. Paulo Marin, EE/BSc, MSc, PhD. Electrical Engineer, ICT Consultant

Using Laser-Optimized Multimode Fiber for 1 and 10 Gigabit Campus Backbone Applications

PRODUCT CATALOG. Certification, qualification, verification & troubleshooting of network infrastructure from copper up to 2,500MHz to fiber.

FTT-ACP: Ready for the future in building cabling WHITEPAPER

Testing Considerations for Beyond 10Gigabit Ethernet. Erin Hallett

PreCONNECT DUODECIM PRODUCT INFORMATION

NGEAB-T Use Cases. Berlin, Germany February Chris DiMinico MC Communications/Panduit

Fiber Design for 1 Gigabit and 10 Gigabit Campus Backbone Applications

November 2013 IEEE 802.3

Addressing issues in the local area network

Appendix 1 to the R&Mfreenet Warranty Program

Industrial 10G/5G/2.5G/1G/100M Copper to 10GBASE-X SFP+ Media Converter

Optical Fiber for Today s Premises Applications

FTTE Revisited for New Technologies

NGBASE-T Cabling Requirements

Data sheet C6 A modul 90 jack

Active Optical Cable. Optical Interconnection Design Innovator 25G SFP28 AOC 10G SFP+ AOC. Shenzhen Gigalight Technology Co.,Ltd.

The following pages contain a guide for the installation

1-Port 10G SFP+ Fiber Optic Network Card - PCIe - Intel Chip - MM

RapidNet. 6A Solutions

optical fiber The two tasks of the network-access-layer are divided into two different layers in the OSImodel.

The Quality Connection. LEONI QuickLine Class E Cabling Solution

Global Ethernet Standards

Uniprise Structured Cabling Solutions Guide

Key Items: - Customer Premises Cabling - 1 ISO/IEC SC25/WG3 Meeting Milan: Sep 2015

How to Decide on Optical Fibre Termination Options. Thomas Ko, RCDD Product Manager Tyco Electronics / AMP NetConnect

INFRASTRUCTURE STANDARDS - STABILITY AT LAST?

Optics Modules and Cables Data Sheet

Cisco 100GBASE QSFP-100G Modules

ISO/IEC Edition INFORMATION TECHNOLOGY GENERIC CABLING FOR CUSTOMER PREMISES. Part 1: General requirements CORRIGENDUM 1

Data sheet. 25Gmodul. Illustrations P/N 130B11-25-E EAN Product specification. Page 1/ Dimensional drawing

WHEN BIGGER IS BETTER

Transcription:

Meeting updated ISO/IEC11801

Premium Line Systems Group Premium Line Systems GmbH, Based in Germany, it is the worldwide headquarter 25 Years experience in Cabling and Networking products End-to-End comprehensive solution for the network infrastructure. 2

Standard Worldwide Overview

ISO/IEC 11801-х The standard has been revised and now ISO/IEC 11801 includes of the following six parts: ISO/IEC 11801-1 Part 1: General Requirements (copper and optical), in support of the other Parts in the series; ISO/IEC 11801-2 Part 2: Office premises (commercial building); ISO/IEC 11801-3 Part 3: Industrial premises (factory automation); ISO/IEC 11801-4 Part 4: Single Tenant Homes (residential building); ISO/IEC 11801-5 Part 5: Data Centers ; ISO/IEC 11801-6 Part 6: Distributed Building Services (intelligent building);

ISO/IEC 11801-х Standard's Part ISO/IEC 11801-1 Part 1: General Requirements ISO/IEC 11801-2 Part 2: Office premises ISO/IEC 11801-3 Part 3: Industrial premises ISO/IEC 11801-4 Part 4: Single Tenant Homes ISO/IEC 11801-5 Part 5: Data Centers ISO/IEC 11801-6 Part 6: Distributed Building Services Current Standard No. Prior Standard No. 11801-1 11801 11801-2 11801 11801-3 24702 11801-4 15018 11801-5 24764 11801-6 -

ISO/IEC 11801 «3 rd edition» The title will not include "3rd edition", because in fact, the standard has an updated numbering Accordingly this is the first edition for this number. Now the correct name will look like this ISO/IEC 11801-1:2017 (for the first part). or ISO/IEC 11801-1 Ed 1.0 2017 Old name ISO/IEC 11801 Ed 2.0 2011

ISO/IEC 11801 major updates. new cables and categories Class-I/Cat8.1, Class-II/Cat8.2 bandwidth 2000 MHz maximum channel length 30m. Channel Class Category Bandwidth Maximum channel length Class-D CAT5e 100 MHz 100 м Class-E CAT6 250 MHz 100 м Class-F CAT7 600 MHz 100 м Class-E A CAT6 A 500 MHz 100 м Class-F A CAT7 A 1 000 MHz 100 м Class-I CAT8.1 2 000 MHz 30 м Class-II CAT8.2 2 000 MHz 30 м

ISO/IEC 11801 major updates. Overview of the different «Cat.8» Cat. 8 Class Cat.8 link Bandwidth Standard 25G BASE- T 40G BASE- T RJ45 jacks 2 000 MHz ANSI/TIA yes yes yes 8.1 I 2 000 MHz ISO/IEC yes yes yes 8.2 II 2 000 MHz ISO/IEC yes yes no

ISO/IEC 11801 major updates. new categories for fiber optic are OM5 and OS1a OM5 multimode - full backward compatibility to OM4 OM5 multimode support Short Wave Division Multiplexing applications 25GBASE-SR with one pair ОМ5 fibers

ISO/IEC 11801 major updates.

ISO/IEC 11801 major updates. minimum requirement for horizontal cabling for different LAN: - Office Premises is now Class E (Cat 6), Class EA (Cat 6A) is recommended in support of applications above 1Gbit/s (Part 2); - Data Centers (Part 5) and Distributed Building Services (Part 6) is now Class E (Cat6); OM1, OM2 and OS1 cabled optical fiber categories are not supported for new installations; 12/24-fiber MPO are specified for the Equipment Outlet in Data Centers;

ISO/IEC 11801 major updates. Added Environmental Classification: 1 2 3 Mechanical rating M 1 M 2 M 3 Ingress rating I 1 I 2 I 3 Climatic rating C 1 C 2 C 3 Electromagnetic rating E 1 E 2 E 3 And new structural elements : o Consolidation point link; o Direct attached channel; o End to End link (E2E link).

ISO/IEC 11801 conclusions. Updated standard with 6 parts New cables and categories Class-I/Cat8.1, Class-II/Cat8.2 New categories for fiber optic are OM5 and OS1a Environmental Classification Office Premises is now Class E Data Centers and Distributed Building Services is now Class E Road map for the next 5 years!

Thanks!