Universal otor Controller UC-FBP High-grade otor Protection and Control
The FieldBusPlug concept This new ABB product family is a communication device range with switching and automation components which can be combined easily with standard fieldbus systems. Process monitoring/controller Controller / PLC (any) All important fieldbus types, e. g.: PROFBUS-DP Field level FBP devices (fieldbus-neutral) AS-nterface DeviceNet CANopen* ODBUS * in preparation Connection with FieldBusPlugs One device for all fieldbus types Each complete device, and each function module within the product family, has a fieldbus-neutral interface. A specially prefabricated connection cable establishes the communications connection with its bus-specific plug interface. n this way, flexibility, transparency and reliability in the process are achieved. The connecting, operating and diagnostic elements are placed at the front of all devices providing increased ease of installation. The components Fieldbus-neutral device connection Bus-specific electronics Connection to fieldbus The fieldbus plug (FieldBusPlug) is the central communications element of the new product family. t connects devices and device combinations of different functions and characteristics as well as simple sensors with automation devices. A great variety of switching and automation modules belong to the product family separated into similar performance characteristics, e.g. devices for motor protection, motor control and standard sensors. Fieldbus connection () Different cable lenghts
Overview Features 7 ounting by four screws Current path Terminals for digital outputs 6 ntegrated motor control and protection Current range of. to 6 A within one device Connection of current transformers for higher currents 6 digital inputs ( DC) and relay outputs ( AC) FieldBusPlug interface (Fieldbus neutral) mountable on the front Different control functions selectable, e.g. direct starter, reversing starter, star-delta starter, Electronic overload protection Trip classes,,, Phase loss protection otor blocking protection Fault input for e.g. external thermistor, earth fault module or emergency stop Control - ia control system and fieldbus - anual via mountable - anual via digital inputs with switches/push buttons 6 7 FieldBusPlug interface (Fieldbus neutral) Terminals for digital inputs Terminals for external supply voltage (optional) Features (extract) S t a r t onitoring e.g. address Current fault incl. acknowledge /O-signals... Edit e.g. password check local control address adjust current Edit e.g. password change control function LOC RE FAULT mas khz% Cprm OUTPUT PAR SET ENU FWD RE trip class... fault input behaviour if bus fails... ENU LOC RE ENTER ENU ENTER Accessories (optional) ounting set for e.g. drawer unit, P 6 m cable between UC-FBP and
Construction Addressing This modular construction allows the easy replacement of parts. The address appears immediately on the - with power on ( mounted) - when mounting the. UC-FBP: current transformer set CPU UC-FBP: controller unit Coupler, bus master No address Address Replacement of the control unit only. n principle the address in the UC-FBP dominates to keep the relation to the motor. The address can be changed with the control panel. Label. f the UC-FBP does not contain any address but the FieldBusPlug does, the address in the plug is valid. ACS-PAN: (optional) Complete device. f no address is set, the UC-FBP will not start. Current transformer. f the address in the UC-FBP is different from the address in the plug, a fault will be indicated. anual setting will be necessary. FieldBusPlug Control unit out of order Replacement of the complete UC-FBP Remove FieldBusPlug and /O terminals Replace only the control unit The motor lines need not be removed nsert the FieldBusPlug and the /O terminals New control unit Example of Parameters N 69 / Fault CPU Coupler, bus master The parameters are uploaded from the current transformer during power on automatically SWTCH FieldBus Plug UC EXT NT 6 7 8 9 C C Direct Starter with all functions Parameter Options: D D D D 6 D 7 D 8 Control function check-back via auxiliary contact Thermistor switch When the device is removed the FieldBusPlug informs the automation system. The FieldBusPlug retains the slave address. When the new device is fitted the FieldBusPlug programs it with the former slave address. The automation system can now download the correct parameters and start the device. external (EXT) supply D D D Hand Local D On D Off Bus --------Supply ---------- Signale zum local control PTC of contacts Fault output, e.g. to lamp Fault signal input, e.g. for thermistor Local control via inputs
Construction Addressing This modular construction allows the easy replacement of parts. The address appears immediately on the - with power on ( mounted) - when mounting the. UC-FBP: current transformer set CPU UC-FBP: controller unit Coupler, bus master No address Address Replacement of the control unit only. n principle the address in the UC-FBP dominates to keep the relation to the motor. The address can be changed with the control panel. Label. f the UC-FBP does not contain any address but the FieldBusPlug does, the address in the plug is valid. ACS-PAN: (optional) Complete device. f no address is set, the UC-FBP will not start. Current transformer. f the address in the UC-FBP is different from the address in the plug, a fault will be indicated. anual setting will be necessary. FieldBusPlug Control unit out of order Replacement of the complete UC-FBP Remove FieldBusPlug and /O terminals Replace only the control unit The motor lines need not be removed nsert the FieldBusPlug and the /O terminals New control unit Example of Parameters N 69 / Fault CPU Coupler, bus master The parameters are uploaded from the current transformer during power on automatically SWTCH FieldBus Plug UC EXT NT 6 7 8 9 C C Direct Starter with all functions Parameter Options: D D D D 6 D 7 D 8 Control function check-back via auxiliary contact Thermistor switch When the device is removed the FieldBusPlug informs the automation system. The FieldBusPlug retains the slave address. When the new device is fitted the FieldBusPlug programs it with the former slave address. The automation system can now download the correct parameters and start the device. external (EXT) supply D D D Hand Local D On D Off Bus --------Supply ---------- Signale zum local control PTC of contacts Fault output, e.g. to lamp Fault signal input, e.g. for thermistor Local control via inputs
onitoring Signals, Commands and Diagnosis Signals Controller / PLC (any) Commands Run Forward Off Run Reverse* Auto ode Fault Reset Commands onitoring Signals Diagnosis onitoring Signals Run Forward Off Run Reverse* Local Control Fault Warning Reversing lock-out time Diagnosis Self test failed External fault Overload fault otor blocked** Communication fault Parameter out of range Current check-back fault** Relay - check-back fault** otor current high/low threshold** Cooling time running** Reversing Lock-out time running** Parameter number UC outputs UC outputs UC inputs /O odules Digital Output * Digital Output * Digital Output * UC inputs Digital nput D* Digital nput D* Digital nput D* Digital nput D* Digital nput D* Digital nput D* * used depending by appropriate Control function ** if activated by appropriate Control function
Technical Details and Dimensions ain Power Lines oltage (three-phase systems) max. 69 AC, Hz Conductor holes through the current transformers max. mm (max. diameter incl. insulation mm) Settable current range for overload protection. A...6 A Trip classes,,, Short-circuit protection seperate fuses on the power line side Protection for three-phase motors complete overload protection Control Unit Supply voltage mode Supply voltage Supply current (incl. inputs, relays) Total device power dissipation Reverse polarity protection Number of digital inputs Number of relay outputs Number of bus interfaces Number of interfaces nternal signal procesing of control function and other properties Parameter setting Bus address setting LEDs on front internal or external 9..... DC including ripple max. ma (at 8... DC) max.. W (at DC) yes 6 (D... D) (... ) (for connecting an ABB FieldBusPlug) (to mount ACS-PAN) selectable by parameters via fieldbus, via e.g. with LED, green: device ready for operation LED, yelow: motor current > % of s LED, red: fault (trip, device fault, ect.) FieldBusPlug connection ounting plug connection, fastening with integrated screw Suitable ABB FieldBusPlug types Order Code (cable length:. m /. m / m / m) PDP-FBP (PROFBUS-DP) SAJ R / R / R / R DNP-FBP (DeviceNet Plug) SAJ R / R / R / R RP-FBP (ODBUS) SAJ R / R / R / R in preparation: COP-FBP (CANopen) Digital inputs Number of digital inputs 6 (D... D) Supply for digital inputs internal or external Supply output current for inputs max. 7 ma (at terminal ) oltage when standard contacts are used min. 8 solation none nput signal bounce suppression typ. ms nput signal voltage -Signal (range including ripple) +... +. -Signal (range including ripple) -.... + nput current per channel ( DC) typ. 6. ma nput resistor to.9 kohm Line length unshielded max. 6 m Line length shielded max. m Digital outputs Number of digital outputs outputs (...) Type of digital outputs relay contacts Grouping of contacts contacts with common oltage range of contacts... AC/DC Switching capacity per relay contact AC (AC / EN 697--) max.. A (AC, electromagnetic load) AC (AC / EN 697--) max. A (AC, electromagnetic load) DC (DC / EN 697--) max.. A (DC, electromagnetic load) DC (DC / EN 697--) max.. A (DC, electromagnetic load) DC (DC / EN 697--) max.. A (DC, electromagnetic load) Total current all contacts (terminal or 6) max. A (thermal limit) Lowest switching power for correct signals W or A Switching of inductive power nductive loads need additional measures for spark suppression. Diodes for DC voltage and varistors / RC elements for AC voltage are suitable. Some DC coil contactors contain rectifiers which suppress sparks perfectly. Relay contact lifetime, mechanical switching cycles Lifetime AC /. A switching cycles Lifetime AC /. A switching cycles nternal clearance and creepage distances >. mm (safety insulation up to AC) relay contacts to circuit (EN 697-, Pollution degree ) Environmental and mechanical data ounting on DN rail (EN -) or with screws Dimensions (W x H x D) 7 x x mm (incl. FieldBusPlug and ) Net weight (current transf. + control unit).9 kg Terminal conductor cross section max.. mm or max. x. mm Current transformer bushing holes mm Ø ( mm ) Degree of protection P Storage temperature range -...+7 C Operating temperature range...+ C Approvals CE, UL, CSA, ATEX Approvals (pending) GL, B, LRS Ordering data 7 6. 87. Universal otor Controller UC-FBP ACS-PAN Extention Cable ACS-CAB Technical description CD-RO Order Code SAJ R Order Code SAJ R Order Code SAJ R Order Code CDC Dxx Order Code CDC 9 8 Exx 97. 9 ca. front view: FieldBusPlug and connected view from the left: FieldBusPlug and connected
Universal otor Controller UC-FBP High-grade otor Protection and otor Control in modern switchgear centres Brochure No. CDC D Printed in the Federal Republic of Germany (6.) subject to modification abb ABB STOTZ-KONTAKT GmbH P. O. Box 6 8 696 Heidelberg Germany Telephone:++9 6 / 7- Telefax: ++9 6 / 7-79 http://www.abb.de/stotz-kontakt Email: desst.info@de.abb.com ABB Global Contact Directory The ABB Contact Directory (http://www.abb.com/contacts/) helps you find local contacts for ABB products in your country. Please select the relevant product group from the dropdown menu to the right or from the page.