Freelink Remote Control

Similar documents
Vercise DBS Remote Control 3 Handbook

Bionic Navigator 2.04 Installer (DB )

Precision Spectra Remote Control Handbook, , Rev C

Vercise M8 Adapter. Directions for Use

Vercise DBS Programming Manual

Vercise M8 Adapter. Directions for Use REV B

BionicNavigator 1.2 Software Guide

Bionic Navigator 1.2 Software Guide

Patient Data Management

ProntoPro Intelligent Remote Control. User Guide

Table of Contents. Taking a First Look 2 Intelligent Remote Control 2 Before You Start 4

CF3000 Dealer Diagnostic Tool Instruction Manual

FHD Driving Recorder E272S/S272W. Quick Start Guide

6165 MONEY COUNTING SCALE

installation and operation guide LATITUDE Link data management system 6215 LATITUDE Link Viewer 6216 LATITUDE Link Import Utility

MAJORITY PETERSFIELD. Digital & FM Pocket Radio. Instructions Guide CB1A-DAB-BLK

Tablet PA752C. User Manual

Clinician Programmer Print Tool For use with Prometra Programmable Infusion Systems Software Version

CLOVER 10 Handheld Video Magnifier User Guide. Rev G

HE413002B INSTRUCTION MANUAL

DEUTSCH ENGLISH NEDERLANDS FRANÇAIS NORSK ITALANIO ČEŠTINA Hersteller DAB650SI

MEEM Memory Ltd. User Guide ios

Electronic data system application end user manual

Phone Quick Reference Guide. Rev2. M I T E L. EMEA CALA. Global Headquarters U.S. Asia Pacific

Table of Contents. Introduction 2 1. Intelligent Remote Control 2 2. Charging the Remote Control 3

ilook 25 Next Generation in Portable Ultrasound Delivering the Personal Imaging Tool

USER GUIDE. T52 two-way pager

IMPORTANT: READ THESE INSTRUCTIONS IN THEIR ENTIRETY BEFORE YOU BEGIN UPDATING THE NAVIGATION SYSTEM.

Network and Connectivity

Clinician Programmer Print Tool For use with Prometra Programmable Infusion Systems Software Version

For your safety and protection of the E-bot, please read and abide by the following important safety precautions.

Please read and retain these instructions for future reference v002: 14/03/17. Cradle, Charger, Instruction manual, Lithium-ion Battery 3.7 V d.c.

BlackBerry Wireless Handheld Getting Started Guide

GSM FWP ETS-6588 USER S MANUAL

Stratus 6 Zone Kit Installation and Operation Guide

mart atch B502 User Manual

HawkEye 45T Display User Manual

USERS MANUAL.

T E C H N O L O G I E S. User Guide. 1:1 HDD Duplicator PRO (HDUSI325)

MXHP-R500. Remote Control

Table of contents. Getting Started. Other Features. Unlocking. Lock ID & Maintenance. Finding & Sharing

615HD Digital Video Camera

User Guide. CG666 Page 2. Open the back cover and remove the battery. Insert the SIM card correctly in the card slot as shown below.

CARELINK NETWORK UPDATES SUMMARY OF ENHANCEMENTS May 2017

USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE.

User s Guide. Creative Desktop Wireless 9000 Pro

CLIP ON MIRROR MONITOR

INSTRUCTION MANUAL. Model 600C Radio Remote Control Handset

Please read and retain these instructions for future reference. Cradle, Charger, Instruction manual, 3.7V Lithium-ion battery included.

CareFusion. Overview of the CareFusion Device. Press Red button on top right-hand corner to turn device on and off

Unpacking... 3 Getting Started... 3 Tour of the Remote... 4 Hard keys...4 Interactive LCD screen...5

AZATOM Multiplex D1 Digital Radio. DAB+/DAB/FM Radio with Bluetooth. User Manual. This manual is available to download online at

DVR 505 Digital Camcorder

Operation Guide. NW-A1000 series / A3000 series Sony Corporation (1)

Label Printer QL-810W/820NWB. Quick Setup Guide (English)

Important Medical Device Advisory NM Implantable Pulse Generator Inaccurate Elective Replacement Indicator

Help Guide. Getting started. Use this manual if you encounter any problems, or have any questions. What you can do with the Bluetooth function

MINI BOX User s Manual

Updating the Nokia E71 software via Nokia Suite

ZONETOUCH DAMPER CONTROL SYSTEM Operation Manual

Breeze FB201 Phone User Guide

CLOVER 5 Handheld Video Magnifier User Guide. Rev E

Lenovo ideapad 110S. User Guide. ideapad 110S-11IBR. Read the safety notices and important tips in the included manuals before using your computer.

Streaming Smart Stick. Quick Start Guide

Please read and retain these instructions for future reference

User Guide. for Card Reader and Payment Application

RZCPG USER GUIDE 1 ON OFF 2 ON OFF 3 ON OFF 4 ON OFF

User Guide for 7950 V2. Amcom Software, Inc.

EO-MN910. User Manual. English (USA). 12/2014. Rev.1.0.

AZATOM Pocket Go. Portable DAB+ / DAB / FM Radio Alarm Clock. User Manual. This manual is available to download online at

DVR 548HD Digital Video Recorder

LDM M LASER DISTANCE MEASURER

MDLINK MANUAL PART NUMBER A Cardiac Science Corporation

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A

Cordless Internet Telephony Kit

Help Guide. Getting started. Use this manual if you encounter any problems, or have any questions. What you can do with the BLUETOOTH function

Power. Document Part Number: This guide explains how the computer uses power. December 2005

Getting Started... 1 Overview... 2 System Requirements... 2 Components... 3 Device Display... 5 Display Indicators... 5 Battery Management...

Bridgemate Pager. Messaging system for tournament directors. Manual Bridge Systems BV

BOOM DAB DAB/DAB+/FM RADIO + WIRELESS

DVR 528 Digital Video Camera

Universal Krell Touch Screen Remote

DVR 508NHD Digital Camcorder

CaDD -Solis Medication Safety Software Version 3.1 For use with the CADD -Solis Ambulatory Infusion Pump with Programmed intermittent Bolus (PiB)

Patient Services - Configuration User Guide

Digital 2.4GHz 3.5 LCD Monitor

USER MANUAL. AL20B Fingerprint Lock with Touch Keypad. Version: 1.0 Date: November, 2017

Saver EVO TM. User Manual USER MANUAL

2.4GHz Digital Wireless 7 LCD Surveillance Kit

TIP CARD MODEL TEMPORARY EXTERNAL PACEMAKER. Model Single Chamber Temporary Pacemaker

BT Q DECT Phone. 1 Display 2 Battery charge status 3 Display Keys 4 Control Key 5 Feature Keys 6 Dialpad 7 Microphone 8 Signal strength

Oracle Beehive. Before Using Oracle Beehive Client and Communicator. Using BlackBerry with Oracle Beehive Release 2 ( )

Breeze III FB201N User Manual

High Accuracy Gloss Meter Operation Manual. This manual is only suitable for our single angle and multi-angles gloss meters.

SAFARI Montage Endpoint

DVR 514 Digital Video Recorder

ZTE MOBILE HOTSPOT QUICK START GUIDE

Using memory cards (not supplied)

GETTING TO KNOW YOUR TELSTRA PRE-PAID 4GX WI-FI PLUS

Displaying Information on LCD screen... 6 Icon Instructions... 7

Transcription:

Freelink Remote Control Directions for Use CAUTION: Federal law restricts this device to sale, distribution and use by or on the order of a physician. 91171771-02 Content ID: 92089552 REV A

Guarantees Boston Scientific Corporation reserves the right to modify, without prior notice, information relating to its products in order to improve their reliability or operating capacity. Drawings are for illustration purposes only. Trademarks All trademarks are the property of their respective holders. Additional Information For Indications and related information, see the Indications DFU. For contraindications, warnings, precautions, adverse events summary, physician instructions, storage and handling, component disposal, and contact information for Boston Scientific, refer to the Information for Prescribers DFU for your spinal cord stimulator system. For other device-specific information not included in this manual, labeling symbols, and warranty information, refer to the appropriate DFU for your SCS System as listed on your Reference Guide. Product Model Numbers Model Number SC-5260 SC-5562-1 Description Freelink Remote Control Freelink Remote Control Kit 91171771-02 ii of iii

Table of Contents Description...1 Cautions...1 Remote Control Features...1 Basic Operation...2 Unlocking the RC...2 Turning Therapy On/Off...2 Selecting Your Language/Screen Preference...2 The Home Screen...3 Adjusting Stimulation Amplitude from the Home Screen...4 The Main Menu...4 Accessing the Main Menu...4 Program Selection and Activation...5 Selecting Stimulation Areas to Modify Programs...6 Saving Modified Programs...8 Restoring Programs...9 Copying Programs...10 Deleting Programs...11 Managing Schedules...12 Entering a Therapy Rating...16 Accessing System Settings...17 Remote Settings...17 System Info...20 Accessing the Clinician Menu...22 Impedances...25 Reset Stimulator...25 Exit Clinician Mode...25 Lead Check (Precision Montage MRI Stimulator Only)...26 Recharging the RC...27 Troubleshooting...29 Telemetry Help...29 No Program to Run Screen...30 Invalid Program Screen...30 Unsupported Stimulator Screen...31 System Settings Reset Screen...31 Stimulator Error Screen...31 Remote Error Screen...32 End of Programmed Service...32 Non-rechargeable IPG Battery Status...33 Icon Description and Index...34 91171771-02 iii of iii

Description The Freelink Remote Control (RC) is a handheld device that allows you to communicate with and control the Stimulators. Cautions Keep the RC dry. It should not be exposed to moisture. Do not connect the RC USB port to any other device except to the RC charger provided with it. Keep the RC away from pets, pests and children to avoid damage to the device. Remote Control Features 1. Screen: displays all menus, icons, and messages 2. Lock/Unlock Button : unlocks the Remote Control from sleep mode. 3. Programs Button : displays the Programs menu. 4. Home Button : displays the Home screen. 5. Therapy Button : Turns Therapy ON or OFF 6. Minus Button : Decreases selected parameter 7. Plus Button : Increases selected parameter 8, 9. Navigation Buttons and : allows scrolling through a selected menu 10, 11. Navigation Buttons and : makes a selection 12. Navigation Button : returns to the previous screen 13. USB Port (not shown): allows recharging of the Remote Control with the USB power supply. 91171771-02 1 of 35

Basic Operation Basic Operation The RC communicates with the Stimulator through a radio frequency (RF) telemetry link. The RC has an effective communication range of up to 91.4 cm (36 inches) with the Boston Scientific rechargeable Stimulator, and a nominal effective communication range of 55.9 cm (22 inches) with the Boston Scientific non-rechargeable Stimulators. As an operator of this device, perform only the following service and maintenance tasks on the device: Recharging, see Recharging the RC on page 27 Cleaning Ensure that this device is not in use while performing service and maintenance tasks. Unlocking the RC The RC goes into idle (or sleep) mode when not in use. It can be reactivated by pressing the Lock/ Unlock button on the right side of the RC. Turning Therapy On/Off Press the Therapy ON/OFF button at any time to turn the Stimulator on or off. Selecting Your Language/Screen Preference The RC allows you to choose either an iconic screen or a text screen in one of the languages provided. Refer to Languages on page 19 for additional instructions. Note: Throughout this manual, the English text screen is shown paired with the corresponding iconic screen. Note: All features of the RC listed in this manual may not be available to you (for example, Schedules). The settings displayed are dependent on the stimulator and its configurations. 91171771-02 2 of 35

The Home Screen The Remote Control (RC) Home screen displays information for the specific stimulator and stimulation therapy programmed. If a program is running, the Home Screen will display the following information: Name of the Program Number of the Program Stimulation Amplitude (Level) selected, as both a graph and a percentage of the maximum available limit Example: Home Screens for Stimulators with Active Program Note: When the RC connects to a non-rechargeable Stimulator, the RC will not display the Stimulator battery icon in the upper right corner of the Home screen. If a Schedule is running, the Home Screen will display the following information about the Schedule and the Programs within the Schedule: Number of the Schedule Name of the Schedule Number of the active Program within the Schedule Name of the active Program within the Schedule Total Time that the active Program will run Time that elapsed for the active Program Example: Home Screens for Stimulators with Active Schedules Note: The Schedules feature is available only when connected to the Spectra WaveWriter Stimulator. 91171771-02 3 of 35

Adjusting Stimulation Amplitude from the Home Screen The Main Menu 1. Press the Home button on the left side of the RC to view the Home screen. Note: When the RC connects to a non-rechargeable Stimulator, the RC will not display the Stimulator battery icon in the upper right corner of the home screen. 2. Press the Minus button to decrease the level of stimulation. 3. Press the Plus button to increase the level of stimulation. The Main Menu The Main Menu provides access to the following options: P Programs Schedules Therapy Rating Stimulation Areas System Settings Accessing the Main Menu Note: Depending on stimulator configurations, some selection may be unavailable. 1. Press the button on the left side of the RC to display the Home screen: 2. From the Home screen, press the Right Arrow button to select the Main Menu. 91171771-02 4 of 35

Program Selection and Activation The Programs Menu allows patients to change to another program, save modifications to Programs, restore programs to clinic settings, and delete programs. 1. Press the button on the left side of the RC to display the Programs screen. Note: You can also navigate to the Programs menu from the Main Menu. Refer to Accessing the Main Menu for additional instructions. 2. Select Change Program by pressing the Selection button or pressing the Right Arrow button. 3. Press the Up or Down Arrow buttons to navigate to the desired Program. 4. Press the Right Arrow button to Select the Program. 91171771-02 5 of 35

The Main Menu Selecting Stimulation Areas to Modify Programs Each Program can include settings for up to four Stimulation Areas. Each Stimulation Area is identified by a letter and a name. These Stimulation Areas control Amplitude, Pulse Width, and Rate. From the Main Menu: 1. Select Stimulation Areas. The Stimulation Areas screen displays. Select the desired area. The Area screen displays with the following parameters options: 2. Select the parameter that you would like to modify. Amplitude From the Area screen: 1. Select Amplitude. 91171771-02 6 of 35

2. Press the Minus button to decrease the Amplitude (level) of stimulation. 3. Press the Plus button to increase the Amplitude (level) of stimulation. Pulse Width From the Area screen: 1. Select Pulse Width. 2. Press the Minus button to decrease the Pulse Width. 3. Press the Plus button to increase the Pulse Width. Rate From the Area screen: 1. Select Rate. 2. Press the Minus button to decrease the Rate. 3. Press the Plus button to increase the Rate. 91171771-02 7 of 35

The Main Menu Saving Modified Programs If the stimulation amplitude, pulse width, or rate have been changed, the new settings can be saved as the default stimulation for that Program. The new settings will remain until a new change is saved or the Program is restored to its Clinic Settings. Refer to Restoring Programs for additional information. 1. Press the button the left side of the RC. or From the Main Menu screen, select P Programs 2. Select Save. The Save? screen displays. 3. Select Yes to save. or Select No to discard. 91171771-02 8 of 35

Restoring Programs Restoring Programs removes saved changes to a Program and resets the Program to the original Clinic Settings. 1. Press the button on the left side of the RC. or From the Main Menu screen, select P Programs. 2. Select Restore to Clinic Settings. The Restore screen displays. 3. Select the Program you want to restore. The Restore confirmation screen displays. 4. Select Yes to restore the Program to the Clinic Settings. or Select No to cancel the action. 91171771-02 9 of 35

The Main Menu Copying Programs You can copy an existing Program to a new Program. 1. Press the button on the left side of the RC. or From the Main Menu screen, select P Programs. 2. Select Copy to.... 3. Select the Program that you want to copy the current Program to. 4. The Overwrite? screen displays if you are not copying to an empty slot. Copy to... Overwrite? 3 Program3 Yes No Back Select 5. Select Yes to Overwrite the Program. or Select No to cancel the action. The Copy to... confirmation screen displays. 91171771-02 10 of 35

Deleting Programs 1. Press the button on the left side of the RC. or From the Main Menu screen, select P Programs. 2. Select Delete. 3. Select the Program to delete. 4. Select Yes to Delete the selected program. or Select No to cancel the action. 91171771-02 11 of 35

The Main Menu Managing Schedules Schedules allows patients to select and change to a different schedule, exclude programs from a schedule, or advance to the next program in a schedule. Note: Depending on the stimulator configurations, some selections may be unavailable. From the Main Menu: 1. Press the Down Arrow to navigate to Schedules. 2. Once Schedules is highlighted, press the Selection button or the Right Arrow to access the Schedules Menu screen. Selecting or Changing to a Different Schedule From the Schedules Menu: 1. Select Change Schedule by pressing the Selection button or the Right Arrow button. 91171771-02 12 of 35

2. Press the Up or Down Arrow buttons to navigate to the desired Schedule. 3. Press the Right Arrow button to Select the Schedule. Exclude Program from a Schedule From the Schedules Main Menu: 1. Press the Down Arrow button to navigate to Exclude Program. 2. Select Exclude Program by pressing the Right Arrow 3. Press the Up or Down Arrow buttons to select Yes or No at the prompt. 4. If Yes is selected, the Program Excluded screen displays. 91171771-02 13 of 35

The Main Menu 5. If No is selected, the program will not be excluded and you will be redirected to the Schedules Menu: Advance Program within a Schedule From the Schedules Menu: 1. Press the Down Arrow button to navigate to Next Program. 2. Select Next Program by pressing the Right Arrow 3. Press the Up or Down Arrow buttons to select Yes or No at the prompt. 91171771-02 14 of 35

4. If Yes is selected, the Program Advanced screen displays: 5. If No is selected, the program will not be advanced and you will be redirected to the Schedules Menu: 91171771-02 15 of 35

The Main Menu Entering a Therapy Rating The Therapy Rating is a way for the patient to communicate real time preferences to different therapy types. Their preferences are recorded on a five star rating scale. Note: Depending on stimulator configurations, some selections may be unavailable. From the Main Menu: 1. Press the Down Arrow to navigate to Therapy Rating. 2. Once Therapy Rating is highlighted, press the Selection button or the Right Arrow to access the Therapy Rating screen. 3. Press the Up or Down Arrow buttons to navigate to the rating of the therapy at that moment. 4. Press the Right Arrow button to make a selection. 91171771-02 16 of 35

Accessing System Settings From the Main Menu: 1. Select System Settings. The System Settings screen displays. When using the Precision Montage MRI Stimulator, the Lead Check icon will also appear on the System Settings screen: Remote Settings The Remote Settings option allows you to adjust the Alert Volume, Screen Brightness, and to select your language preference. From the System Settings menu: 1. Select Remote Settings to display the Remote Settings menu. 91171771-02 17 of 35

The Main Menu Alert Volume From the Remote Settings menu: 1. Select Alert Volume. 2. Press the Minus button to decrease the Alert Volume 3. Press the Plus button to increase the Alert Volume. Screen Brightness From the Remote Settings menu: 1. Select Screen Brightness. 2. Press the Minus button to decrease the brightness 3. Press the Plus button to increase the brightness. 91171771-02 18 of 35

Languages The RC allows you to configure your system to display one the following: Text screen in one of the languages provided Iconic screen From the Remote Settings menu: 1. Select Languages. 2. Select the desired language, such as English or iconic display. The Languages confirmation screen displays to confirm your selection. 91171771-02 19 of 35

The Main Menu System Info The System Info menu gives you the option of viewing information regarding the RC or the Stimulator. From the System Settings menu: 1. Select System Info. Remote Info 2. Select Remote Info to view the Remote Info screen. Serial Number Model Number Boot Version Firmware Version The Remote Info screen displays the following information: Serial Number Model Number Boot Version Firmware Version... 91171771-02 20 of 35

Select More to view additional Remote Info. LCD Boot Version LCD Firmware The Remote Info screen displays the following additional information: LCD Boot Version LCD Firmware Stimulator Info 1. Select Stimulator Info to view the Stimulator Info screen. Serial Number Model Number Boot Version Firmware Version The Stimulator Info screen displays the following information: Serial Number Model Number Boot Version Firmware Version Note: The Model number and Serial number for the Trial Stimulator can be found by removing the battery compartment cover on the Trial Stimulator. 91171771-02 21 of 35

Accessing the Clinician Menu Accessing the Clinician Menu The Clinician Menu allows you to link to a Stimulator, clear the link to a Stimulator, check impedances, and reset the Stimulator. It also allows you to use the Remote Control without any of the lockouts that may have been programmed by the Clinician Programmer (e.g., Main Menu, Programs, Pulse Width, Rate). To enter the Clinician Menu you must enter a password. From the System Settings menu: 1. Select the Clinician Menu. The Password screen displays. A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9 Enter Cancel 2. Use the Navigation buttons to Enter your password. Or Use the Navigation buttons to Cancel. If the password is incorrect, the Clinician Menu displays. Invalid Password screen displays. If the password is correct, the Note: If the remote is not linked to a Stimulator, the Stimulator Search option displays on the Clinician Menu instead of the Clear Link option. 91171771-02 22 of 35

Stimulator Search The Clinician Menu allows you to search for a Stimulator and link to it. From the Clinician Menu: 1. Select Stimulator Search. The Stimulator Search screen displays. 2. If the desired Stimulator has not been located, select Rescan. 3. Select the Stimulator that you wish to link to. The Link to Stimulator ######? screen displays. 4. Select Yes to link to the Stimulator. or Select No to cancel the action. 91171771-02 23 of 35

Accessing the Clinician Menu Clear Link If the RC is linked to a Stimulator, the Clear Link option displays on the Clinician Menu. From the Clinician Menu: 1. Select Clear Link. The Clear Link to Stimulator? screen displays. 2. Select Yes to clear the link to the Stimulator. or Select No to cancel the action. 91171771-02 24 of 35

Impedances You can use the RC to check impedances. From the Clinician Menu: 1. Select Impedances. The Impedances screen displays. A1 A2 A3 A4 A5 A6 A7 A8 1450 400 1450 1450 1450 1200 1450 1000 B1 B2 B3 B4 B5 B6 B7 B8 1450 1000 1450 1000 1450 1450 900 8000 2. Select Measure to check impedances. 3. Select Back to go back to the Clinician Menu. Reset Stimulator You can use the RC to reset the Stimulator. From the Clinician Menu: 1. Select Reset Stimulator. The Reset Stimulator? screen displays. 2. Select Yes to reset the Stimulator. or Select No to cancel the action. Exit Clinician Mode From the Clinician Menu: 1. Select Exit Clinician Mode. The System Settings screen displays. 91171771-02 25 of 35

Accessing the Clinician Menu Lead Check (Precision Montage MRI Stimulator Only) For the Precision Montage MRI Stimulator, you can use the Remote Control to test lead integrity. From the Systems Settings menu: 1. Select Lead Check 91171771-02 26 of 35

Recharging the RC The icon at the top left of the Home screen indicates the charge level of the RC battery. The RC will display messages reminding you to recharge the RC or the Stimulator if the battery power is low. Charge Remote Now Recharge the RC battery by connecting the RC to the USB-Power Supply provided with the RC. The RC battery has a typical service life of 400 charging cycles. 91171771-02 27 of 35

Recharging the RC External Trial Stimulator or Rechargeable Stimulator Only Note: The following is not applicable to the Precision Novi Stimulator. The icon at the top right of the Home screen indicates the charge level of the Stimulator battery. The RC will display messages reminding you to recharge the Stimulator if the battery power is low. Charge Stimulator Now Press to continue. Charge Stimulator Now Press to continue. 91171771-02 28 of 35

Troubleshooting Telemetry Help The RC has an effective communication range of up to 91.4 cm (36 inches) with the Boston Scientific rechargeable Stimulator, and a nominal effective communication range of 55.9 cm (22 inches) with the Boston Scientific non-rechargeable Stimulator. Common sources of interference, such as televisions and computer monitors, can affect wireless communication. You will continue to have access to the RC menus even if the RC is outside its effective communication range. If you enter a command to change your settings or programs while the remote control is outside of its effective communication range, you will have several seconds to move the RC within range of the Stimulator to send the command. After the command is received by the Stimulator, the remote control will make a double-beep then display the requested change on the screen. If the RC is unable to communicate with the Stimulator, the Telemetry Error message will appear: Telemetry Error Communication Failed Retry? Telemetry Help? Cancel Select To retry communication with the Stimulator this resends the last command select Retry. To cancel communication and return to the screen, press. The Telemetry Help tool is also available to assist you in improving communication between the RC and the Stimulator. To use the Telemetry Help tool, select Telemetry Help?. The following screen will be displayed: 91171771-02 29 of 35

Troubleshooting The telemetry bars indicate the strength of wireless communication. The number of bars will change depending on the distance and orientation of the RC from the Stimulator. This tool will continue to measure the strength of communication for 30 seconds or until is pressed. Test the Remote at Different Positions Test the Remote at Different Positions Press to Exit Press to continue. No Program to Run Screen This screen is displayed when the Stimulator has no Programs to run. P P No Program to Run 0 Press to continue Press to continue. Invalid Program Screen This screen is displayed when the Stimulator attempts to run an invalid Program. P P Invalid Program? Press to continue Press to continue. 91171771-02 30 of 35

Unsupported Stimulator Screen This screen is displayed when the RC detects an incompatible Stimulator. Press Unsupported Stimulator? to continue? Press to continue. System Settings Reset Screen This screen is displayed when the RC experiences an error and a reset of the RC is required. Press to continue. All RC settings will be restored to the default factory settings. System Settings Reset Press to continue Press to continue. Stimulator Error Screen This screen is displayed when there is a non-critical Stimulator error. Press message and continue. to acknowledge the Stimulator Error Press to continue Press to continue. 91171771-02 31 of 35

End of Programmed Service Remote Error Screen This screen is displayed when there is a critical error on the RC which causes the RC to be unusable. Advise the patient to contact Boston Scientific or their healthcare provider to order a replacement RC. Remote Error Press to continue Press to continue. End of Programmed Service The Stimulator software has been programmed to end service after a defined period. When the Stimulator is within approximately 180 days of the end of its programmed period, the RC will display the following on-screen message. Press to continue. Press to clear the message. The message will reappear approximately weekly until the end of the Stimulator s programmed period is reached. When the end of its programmed period is reached, the RC will display the following on-screen message. 91171771-02 32 of 35

Non-rechargeable IPG Battery Status ERI (Elective Replacement Indicator) Screen The implanted non-rechargeable Stimulator is nearing end of service. Changes made to the stimulation will not be saved, and stimulation will not be available soon. Advise the patient to contact their healthcare provider to report this message. Press the select key to clear this information screen. This screen will appear whenever the RC is activated. End of Battery Life Screen The implanted non-rechargeable Stimulator has reached its end of service. Stimulation is not available. Advise the patient to call their healthcare provider. 91171771-02 33 of 35

Icon Description and Index Icon Description and Index L A Alert Volume 17, 18 Amplitude 4, 6 A B... Areas 4 M Languages 2, 19 Lead Check 17, 26 C Change Program 5 Change Schedule 12 Clinician Menu 22, 24, 25 N P Main Menu 22 Navigation 1, 22 No 8, 9, 10, 11, 23, 24, 25 Copy to 10 P Program 4, 8, 9, 10, 11 D Pulse Width 6, 7, 22 Delete Program 11 R E Rate 6, 7 H Exclude Program 13 Home 4, 27 Remote 17, 18, 19, 32 Remote Battery 27 Remote Information 20 Restore to Clinic Settings 9 Retry 29 91171771-02 34 of 35

S Save Program 8 Schedules 3, 4, 12 Screen Brightness 17, 18 Stimulation Area 6 Stimulator 2, 23, 25, 27, 28, 31 Stimulator Battery 4, 28 Stimulator Information 21 System Info 20 T System Settings 4, 17, 22, 31 Therapy OFF 2 Therapy ON 2 Therapy Rating 4, 16 Y Yes 8, 9, 10, 11, 23, 24, 25 91171771-02 35 of 35

Legal Manufacturer Boston Scientific Neuromodulation Corporation 25155 Rye Canyon Loop Valencia, CA 91355 USA (866) 789-5899 in US and Canada (661) 949-4000, (661) 949-4022 Fax (866) 789-6364 TTY www.bostonscientific.com Email: neuro.info@bsci.com AUS Australian Sponsor Address Boston Scientific (Australia) Pty Ltd PO Box 332 BOTANY NSW 1455 Australia Free Phone 1800 676 133 Free Fax 1800 836 666 EU Authorised Representative Boston Scientific Limited Ballybrit Business Park Galway, Ireland T: +33 (0) 1 39 30 97 00 F: +33 (0) 1 39 30 97 99 2017 Boston Scientific Corporation or its affiliates. All rights reserved. 91171771-02 2017-08