Surge Protective Devices. STV100K Series. Instruction Manual

Similar documents
Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protective Devices. STV25K Series. Instruction Manual

Surge Protective Devices. Installation & Operation Manual. NEMA 12 (Steel) NEMA 1 (Non-Metallic) Model 350

300 Series 330/320 Surge Protective Device Installation, Operation and Maintenance Manual

400 Series 460 Surge Protective Device Installation, Operation and Maintenance Manual

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

R-LB R-LX Series Installation, Operation & Maintenance Manual

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

Specifications, Installation, and Operating Instructions

GE Digital Energy. Power Quality

INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs)

BSPD Surge Protective Devices

Eaton s SPD Series for integration into electrical distribution equipment

Installation and Operation Manual

Instruction Manual IM E Table of Contents

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

TDX Series. Transient Discriminating TM TVSS

THE SURGE PROTECTION SOLUTION

GENERAL UL th EDITION DESIGN-BUILD SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

Hubbell Surge Protective DeviceS

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

GE TR7000 Series Wall Mounted Surge Protective Device (SPD)

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Instruction Manual: IM E

File E Project 08NK November 24,2009 REPORT TRANSIENT VOLTAGE SURGE SUPPRESSORS (VZCA/VZCA7)

Installation and Operation Manual

File E Project 05NK Issued: Revised: REPORT CLASSIFIED FOR USE WITH SPECIFIED EQUIPMENT (XUPD)

File E Project 08NK October 2, 2009 REPORT SURGE PROTECTIVE DEVICES (VZCA) GE Zenith Controls Bonham, TX

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Total Protection Solutions Surge Protective Devices SurgeTrack Series: 080, 120, 160, 240, 300 and 400

Liebert LM Series Surge Protective Device Continuous Protection For Your Business. Surge Protection For Business-Critical Continuity

Instruction Bulletin Boletín de instrucciones Directives d'utilisation , Rev. 02, 03/2016

NEMA 1 / IP40 metal housing. Compact design

SOUTH CAROLINA ELECTRIC COOPERATIVES SECONDARY TYPE 1 SURGE PROTECTIVE DEVICE SPECIFICATIONS Updated/Revised: October 6, 2014

PHOENIX CONTACT Features

Internal Modular SPDs

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

Installation Instructions & User Manual

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

Installation Instructions & User Manual POWERWARE TVSS ZONESENTINEL. AC Panel Transient Voltage Surge Suppressors

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

SURGE PROTECTION USER MANUAL. Surge Protection Device PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) B

for the SPV Installation and Operation Manual Instruction Manual IM E Contents

Specifications 1 Installation Procedures 2 Wiring Diagrams 3 Installation Checklist 5 Maintenance 5 Warranty Information 6 Material Return Policy 6

Surge Protective Devices Installation, Operation and Maintenance Manual. ServiceTrack ST Series: 080, 120, 160, 200, 240, 300 and 400

Surgelogic Surge Protective Device I-Line Plug-On Unit Series

I-Line SPDs Square D TM Internally Mounted Surge Protective Devices

CPS block & CPS nano UL rd Ed. Surge protective devices (SPD)

Eaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289

Eaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.

ZoneMaster Series Surge Protection Devices

Liebert TVSS: The First Line of Defense - Product Overview. Jim Tiesi

White Paper Surge Protective Devices in Automatic Transfer Switches

LPI SST Surge Filters

PDI Modular Compact Remote Power Panel

Panelmount (Facility-Wide) Surge Protection

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

Eaton SPD Series. for Mounting External to Electrical Distribution Equipment. Instruction Manual IM E Effective March 2014 Rev.

Liebert LM Series. Continuous Protection For Your Business. Surge Protection For Business-Critical Continuity

Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions

TPS3 09. Surge Protective Device. User Manual - USA

Gas Discharge Tube. Indicator Light(2) UL Parallel 1600 V N N / PU-20KS10KTTN. UL Series 1600 V N N 15 A PU-20KD10KTTN

US Catalog March Surge protective devices (SPDs) UL range

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

Technical Data Sheet Medium Current Power Surge Filters

SECTION SURGE PROTECTIVE DEVICES

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

TransEnd Surge Suppression Filter Systems

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Clipper Power System Visor Series

Eaton SPD Series. Instruction Manual IM E Effective June 2014 Rev. 2

Always "On" UPS Systems Inc. USER MANUAL

Eaton Innovative TechnologyT XT50/100 surge protective device

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

TransGuard. Electrical Transient Suppression Filter Systems. Installation, Operation and Maintenance Manual PN ,

Liebert INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Interceptor and Interceptor Hybrid Advantage Series Transient Voltage Surge Suppressors

User Manual - Canada. TPS3 03 DC For DC Photovoltaic Applications. Surge Protective Device

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

SSMx24 Series 240 ka Per Phase Peak Surge Current ANSI/UL1449 UL Fourth Edition

PRO-1250D CT MID DIN rail three phase four wire energy meter.

SECTION TRANSIENT VOLTAGE SURGE SUPPRESSION

LPI SG + SST Spark Gap Surge Filter

DeltaV Bulk Power Supplies

Grid to Chip Surge Protection Product Catalog

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

LPI SG + SS480 Spark Gap Surge Filters

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

DeltaV Bulk Power Supplies

MIL STD 220a (50 Ohm) Model Ordering: 400LS - 277Y - DS - UFP - MX

BUSSMANN. North American UL Type 1, 2 and 4, and data signal surge protective devices SERIES. Application note 3193

Total Home Surge Protection for Point-of-Entry. FirstSurge TM. User Manual - Canada (English)

SEM3 - Embedded Micro Metering Module

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

White Paper October 2009

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

Transcription:

Surge Protective Devices STV100K Series Instruction Manual

Contents 1.0 Installation... 4 1.1 Environment... 4 1.2 Mounting... 4 1.3 Proper Connection of SPDs... 4 1.4 Mechanical Dimensions... 5 1.5 Voltage Protection Ratings (VPRs)... 5 1.6 Circuit Ampacity Limitations... 5 1.7 Wire Sizing/Routing... 5 1.8 Wiring Connections... 6 1.9 Applying Power... 6 2.0 Troubleshooting... 8 3.0 Registration & Warranty... 8 3.1 Product Registration... 8 3.2 Warranty Information... 8 4.0 Specifications... 9 While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. 2011 EGS Electrical Group, LLC. All rights reserved. Specifications are subject to change without notice.

1.0 Installation The SolaHD STV100K Series Surge Protective Device is a high-quality, highenergy surge current diversion system designed to protect sensitive equipment from damaging transient voltage surges resulting from load switching, lightning strikes, and other sources. The installer should perform the following steps to ensure a quality installation. Please read all instructions before starting the installation of this product. These instructions do not replace national or local electrical codes. Check applicable codes to ensure compliance.! DANGER! Only qualified personnel should install or service this system. Electrical safety precautions must be followed when installing or servicing this equipment. To prevent risk of electrical shock, turn off and lock out all power sources to the unit before making electrical connections or servicing. 1.1 Environment The unit is designed for operation indoors in an ambient temperature range of -40 C to +60 C (-40 F to +140 F), with a relative humidity of 0% to 95% noncondensing. The unit is provided in a metallic industrial enclosure. Do not install in areas with excessive dust, corrosive vapors, flammable materials, or explosive atmospheres. 1.2 Mounting Mount the unit as close as possible to the service panel. For best performance, the unit should be positioned so that the length of the wiring to the surge protective device (SPD) is minimized. 1.3 Proper Connection of SPDs Type 2 SPDs shall be installed as defined in the National Electric Code (NEC) 2011 Edition as follows: 285.24 Type 2 SPDs (TVSSs) Type 2 SPDs (TVSSs) shall be installed in accordance with 285.24 (A) through (C). (A) Service-Supplied Building or Structure. Type 2 SPDs (TVSSs) shall be connected anywhere on the load side of a service disconnect overcurrent device required in 230.91, unless installed in accordance with 230.82(8). (B) Feeder-Supplied Building or Structure. Type 2 SPDs (TVSSs) shall be connected at the building or structure anywhere on the load side of the first overcurrent device at the building or structure. (C) Separately Derived System. The SPD (TVSS) shall be connected on the load side of the first overcurrent device in a separately derived system. STV100K Series Instruction Manual 4

1.4 Mechanical Dimensions Figure 1: Mechanical Dimensions (in.) Unit shown is a three-phase wye 1.5 Voltage Protection Ratings (VPRs) To maintain the voltage protection ratings marked on these products, as obtained by Underwriters Laboratories, Inc. in accordance with ANSI/UL 1449, 3 rd edition, the Standard for Safety, Surge Protective Devices (SPDs), #12 AWG wire must be utilized to connect the STV100K Series to your facility s power grid. Connections made with conductors other that #12 AWG may result in different VPRs. 1.6 Circuit Ampacity Limitations This device has been investigated by Underwriters Laboratories, Inc. to withstand, without exposing live circuits or components on power sources, a voltage of two times (2x) the device s ratings, and fault currents of up to 65,000 AIC, as described in ANSI/UL 1449, 3 rd edition, the Standard for Safety, Surge Protective Devices (SPDs). 1.7 Wire Sizing/Routing Phase, N, and GND wires are #12 AWG. NO, NC, and COM wires are #18 AWG. To reduce the wiring impedance to surge currents, we recommend the phase, neutral (if required), and ground conductors to be twisted together and routed in the same raceway (conduit). Avoid any sharp bends in the conductors. All wiring must comply with the National Electrical Code (NEC) and applicable local codes. STV100K Series Instruction Manual 5

1.8 Wiring Connections Before making connections to the unit, verify that the unit model number and nameplate voltage rating are appropriate for connection to the intended power source. See Table 1 for voltage rating applications with typical power source configurations. 1. Connect the black phase wires to the corresponding phase on the service panel. For delta high leg units, ensure the high leg is connected to Phase B of the SPD. 2. Connect the white neutral wire of the SPD (if provided) to the neutral of the supply. Connect the green ground wire of the SPD to source ground. 3. If you are not using the relay contacts for remote sensing, cut and dress the orange COM wire, the blue NC wire, and the yellow NO wire in the conduit. For remote sensing, wires are connected to COM, NC, and NO respectively. (125 V ac, 5 A max.)! DANGER! For proper and safe operation, neutral and ground MUST be reliably connected. Failure to operate this unit from a solidly grounded power source of the proper configuration will reduce or impede operation and may result in unit failure. Figure 2: Wiring connections NOTES: Figure 2 is a three-phase wye. A three-phase delta will have no neutral wire. For a three-phase delta high leg, Phase B will be the high leg. A split phase unit will have no Phase C and can be labeled Line 1 and Line 2. A single-phase L-N unit will have one black phase wire, a white neutral wire, and a green ground wire. A single-phase L-L unit will have two black phase wires and the green ground wire. Summary alarm Form C (1 NO and 1 NC) relay contacts may be provided for remote indication of an SPD failure. This indication may also consist of a phase loss or undervoltage condition. Summary alarm Form C relay contacts are rated 5 A at 250 V ac maximum with a power factor of 1.0. For units with Summary Alarm Contacts, access to the contacts are provided via #18 AWG wires (yellow NO, orange COM, and blue NC). 1.9 Applying Power Apply power to the SPD and ensure status indications are normal. Under normal conditions, the green LEDs are illuminated and the red Service LED is extinguished. If normal status indication does not exist, see 2.0 Troubleshooting. STV100K Series Instruction Manual 6

Table 1: Voltage Ratings & Power Source Configurations Model: 10N Nominal Voltage: 120 V Single-phase, 2W + G Model: 24L Nominal Voltage: 240 V Single-phase, 2W + G Model: 10S Nominal Voltage: 120/208 240 V Single-phase, 3W + G Model: 10Y Nominal Voltage: 120/208 V Three-phase wye, 4W + G Model: 23Y Nominal Voltage: 230/400 V Model: 27Y Nominal Voltage: 277/480 V Model: 10X* Nominal Voltage: 120/208 V Three-phase wye, 3W + G Model: 23X* Nominal Voltage: 230/400 V Model: 27X* Nominal Voltage: 277/480 V *Not UL Listed. Contact SolaHD Technical Support for details. STV100K Series Instruction Manual 7

Table 1: Voltage Ratings & Power Source Configurations Model: 20D* Nominal Voltage: 208 V Three-phase delta, 3W + G Model: 24D Nominal Voltage: 240 V Model: STV 100K-48D Nominal Voltage: 480 V *Not UL Listed. Contact SolaHD Technical Support for details. Model: STV 100K-10D4 Nominal Voltage: 120/240 V Three-phase delta high leg, 4W + G Model: STV 100K-24D4 Nominal Voltage: 240/480 V 2.0 Troubleshooting If any of the diagnostic indicators indicate a problem (e.g. red Service LED on and/or green LEDs off), check all connections and voltages to the unit. If all connections are made and reliable, and proper voltages are supplied to the unit, contact SolaHD Technical Support at (800) 377-4384/(847) 268-6651 or by e-mail at solahd.technicalservices@emerson.com. 3.0 Registration & Warranty 3.1 Product Registration To register your product for updates and information on service and support, visit our Web site at: http://www.solahd.com/support/registration.htm. 3.2 Warranty Information Please see the Terms & Conditions of Sale. STV100K Series Instruction Manual 8

4.0 Specifications Table 2: Technical Specifications Parameters 10N 24L Model 10S 10Y 23Y Nominal Input Voltage 120 V 240 V 120/208 240 V 120/208 V 230/400 V System Configuration 1-phase 2W + G 1-phase 2W + G 1-phase 3W + G 3-phase wye 4W + G 3-phase wye 4W + G Maximum Continuous Operating Voltage 125% of the nominal level for 120 V; 115% for all other voltages (MCOV) Line Frequency 47 63 Hz Response Time <0.5 ns A/C Rating 65 kaic Fusing Thermal and fault current Nominal Discharge Current Rating 3 ka Modes of Protection All Modes: L N, L L, L G, N G Operating Temperature -40 C to +60 C (-40 F to +140 F) Operating Humidity 0 to 95% non-condensing Noise Attenuation 40 dba maximum Dimensions, W x D x H 6.00 in. x 4.00 in. x 3.20 in. (152.4 mm x 101.6 mm x 81.28 mm) Net Weight 8.0 lb. (3.63 kg) Enclosure Metal, NEMA 12 enclosure Connection/Mounting Type Parallel/Flange Status Indication Red and green LED status indicators, audible alarm, Form C contacts Safety Approvals UL 1449 3 rd edition, culus Listed Warranty 10 years UL 1449 3 rd Edition, Type 2 Voltage Protection Ratings Line to Neutral 600 V N/A 600 V 600 V 1200 V Line to Line N/A 1000 V 1000 V 1000 V 2000 V Line to Ground 700 V 1200 V 700 V 700 V 1200 V Neutral to Ground 700 V N/A 700 V 700 V 1200 V High Leg to Neutral N/A N/A N/A N/A N/A High Leg to Line N/A N/A N/A N/A N/A High Leg to Ground N/A N/A N/A N/A N/A Peak Surge Current Capability Per Phase 100 ka 100 ka 100 ka 100 ka 100 ka Line to Neutral 50 ka N/A 50 ka 50 ka 50 ka Line to Line N/A 50 ka 50 ka 50 ka 50 ka Line to Ground 50 ka 50 ka 50 ka 50 ka 50 ka Neutral to Ground 50 ka N/A 50 ka 50 ka 50 ka STV100K Series Instruction Manual 9

Table 2: Technical Specifications Parameters 27Y 24D Model 48D 10D4 24D4 Nominal Input Voltage 277/480 V 240 V 480 V 120/240 V 240/480 V System Configuration 3-phase wye 4W + G 3-phase delta 3W + G 3-phase delta 3W + G 3-phase delta high leg 4W + G 3-phase delta high leg 4W + G Maximum Continuous Operating Voltage 125% of the nominal level for 120 V; 115% for all other voltages (MCOV) Line Frequency 47 63 Hz Response Time <0.5 ns A/C Rating 65 kaic Fusing Thermal and fault current Nominal Discharge Current Rating 3 ka Modes of Protection All Modes: L N, L L, L G, N G Operating Temperature -40 C to +60 C Operating Humidity 0 to 95% non-condensing Noise Attenuation 40 dba maximum Dimensions, W x D x H 6.00 in. x 4.00 in. x 3.20 in. (152.4 mm x 101.6 mm x 81.28 mm) Net Weight 8.0 lb. (3.63 kg) Enclosure Metal, NEMA 12 enclosure Connection/Mounting Type Parallel/Flange Status Indication Red and green LED status indicators, audible alarm, Form C contacts Safety Approvals UL 1449 3 rd edition, culus Listed Warranty 10 years UL 1449 3 rd Edition, Type 2 Voltage Protection Ratings Line to Neutral 1200 V N/A N/A 600 V 1200 V Line to Line 2000 V 2000 V 2000 V 1000 V 2000 V Line to Ground 1200 V 1200 V 2000 V 700 V 1200 V Neutral to Ground 1200 V N/A N/A 700 V 1200 V High Leg to Neutral N/A N/A N/A 1200 V 2000 V High Leg to Line N/A N/A N/A 1500 V 2500 V High Leg to Ground N/A N/A N/A 1200 V 2000 V Peak Surge Current Capability Per Phase 100 ka 100 ka 100 ka 100 ka 100 ka Line to Neutral 50 ka N/A N/A 50 ka 50 ka Line to Line 50 ka 50 ka 50 ka 50 ka 50 ka Line to Ground 50 ka 50 ka 50 ka 50 ka 50 ka Neutral to Ground 50 ka N/A N/A 50 ka 50 ka STV100K Series Instruction Manual 10

www.solahd.com (800) 377-4384 (847) 268-6651 solahd.technicalservices@emerson.com Part Number: 80927 Rev 2 January 2011