Masterswitch 25kW 230V-125A Automatic AC transfer switch

Similar documents
MasterBus USB interface

MasterBus Combi Interface

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Operating instructions. Speed monitor D / / 2014

Operating instructions. Switching amplifier DN0210 DN / / 2015

MasterView Easy MkII

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Installation manual for for Schleifenbauer DPM3

Operating instructions. Standstill monitor A / / 2011

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Installation manual plugs and connectors with screw connection (16/32 A)

MDM 011-Z1 Regen Resistor

V E1B Snap-in I/O Module

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

C-POWER AC AUTOMATIC CONTROL

Installation instructions Inclination sensor EC2019 EC / / 2013

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

V E2B Snap-in I/O Module

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

EX-RC1 Remote I/O Adapter

Installation. MGE Galaxy 3500 and Smart-UPS VT. Maintenance Bypass, Distribution and Transformer Cabinet

MC 11 EB-2 Power supply cabinet with external bus, AC version

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

V E2B Snap-in I/O Module

PV Rapid Shutdown device

PanelView Plus/VersaView CE Terminals and Display Modules

The Martin Experience. Martin Audio CMX1A Cinema Controller MARTIN AUDIO. All material Martin Audio Ltd. Subject to change without notice.

Operating Instructions

PanelView 600 Terminals

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

CPCI-PS24 24V-Power Supply

Manual Control Unit GFC 32

CS2 DMX Distribution Splitter

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

MODEL 805 USER MANUAL

Operating Manual -ENGLISH- Page 1 KWG-ISO

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

VFI RTG PDU 6-10K. Installation and user manual. Service and support: Call your local service representative

Installation instructions Ethernet switch EC / / 2011

V E1B Snap-in I/O Module

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

Manual Simatek Control Unit GFC 32

Manual Control Unit GFC 16

Conductive Level Controller

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Control Unit KEH-P / Force-1.DIN

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

ALPHA Automated Transfer Switch Operating Manual. Rev 1.21 The original of this document is drawn up in English language

Crossfire. User Manual. Order code: EQLED061

CPCI System Subrack 1 U

Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

MANUAL. ENGLISH Showtec PSA-161 Ordercode: Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

EOS-6000 Series Optical A/B Switch User Manual DC Version

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Operating Instructions

User safety and equipment protection guidelines

Accessories for Sunny Central COMMUNICATION CABINET (COM-C)

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

User Manual HMI Linkbox HL01 DP/MPI

RTU500 series Data Sheet Power Supply CP-E 24/2.5

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

EPS Power Supply

GV204 Impulse Splitter for Incremental Encoders

FUE 10 FUE-M/S 85A FUE-M/S 86A

SMVector Additional I/O Module Installation and Operation Manual

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Operating Instructions

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Operating Instructions for Vibrating Level Switches. Model: NVI

Safegard V4 Panel. Installation Datasheet. Safegard V4 Panel Installation Instructions and Datasheet release 1.7 August 2016

Accessories for stand-alone gird inverter SMART LOAD 6000

EC Series. Safety Guide

w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

Flexoled FTP3HP RGB LED DMX Driver

7032 Digital-Analog Multimeter

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

UV Power Flood. User Manual. Order code: EQLED029

Assembly and Operating Instructions. NFC module for BDC-i440 control units

EX-RC1 Remote I/O Adapter

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

EX-RC1 Remote I/O Adapter

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Transcription:

INSTALLATION AND USERS MANUAL Masterswitch 25kW 230V-125A Automatic AC transfer switch MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com ENGLISH: NEDERLANDS: PAGE 1 PAGINA 13 DEUTSCH: SEITE 25 FRANÇAIS: PAGINA 37 v 1.0. September 2007

TABLE OF CONTENTS TABLE OF CONTENTS: v 1.0. September 2007 1 GENERAL INFORMATION... 3 1.1 Use of this manual... 3 1.2 Validity of this manual... 3 1.3 Use of pictograms... 3 1.4 Identification label... 3 1.5 Liability... 3 2 IMPORTANT SAFETY INSTRUCTIONS... 4 2.1 General... 4 2.2 Warning regarding life support applications... 4 2.3 Guarantee specifications... 4 3 HOW IT WORKS... 5 3.1 Source priority... 5 3.2 Input 1 (Generator)... 5 3.3 Input 2 (Shore or inverter)... 5 4 INSTALLATION... 6 4.1 General... 6 4.2 AC wiring... 6 4.3 External fuses... 6 4.4 Ground connections... 6 4.5 Inputs... 8 4.6 Outputs... 8 4.7 Settings... 8 4.8 Commissioning after installation... 8 4.9 Decommissioning... 8 4.10 Transportation... 8 4.11 Re-installation... 8 5 ADDITIONAL INFORMATION... 9 5.1 Specifications... 9 5.2 Outline drawings... 10 5.3 EC declaration of confirmity... 11 2 September 2007 / Masterswitch 25kW 230V-125A / EN

GENERAL INFORMATION 1 GENERAL INFORMATION 1.1 USE OF THIS MANUAL This manual contains important safety and operating instructions for the safe and effective operation, maintenance and possible correction of minor malfunctions of the Masterswitch 25kW, 230V-125A, further mentioned as Masterswitch. It is therefore obligatory that every person who works on or with the Masterswitch must be completely familiar with the contents of this manual, and that he/she carefully follows the instructions and important safety instructions contained herein. The English version of this manual has 12 pages. 1.2 VALIDITY OF THIS MANUAL All of the specifications, provisions and instructions contained in this manual apply solely to standard versions of the Masterswitch delivered by Mastervolt. This manual is valid for the following models: 1.4 IDENTIFICATION LABEL The identification label is located at the right-hand side of the Masterswitch. Important technical information required for service, maintenance & secondary delivery of parts can be derived from the identification label. CAUTION! Never remove the identification label. 1.5 LIABILITY Mastervolt can accept no liability for: consequential damage due to use of the Masterswitch; possible errors in the manuals and the results thereof. Part number Model 55003500 Masterswitch 25kW, 230V-125A For other models see other manuals available on our website: www.mastervolt.com 1.3 USE OF PICTOGRAMS Safety instructions and warnings are marked in this manual by the following pictograms: WARNING A WARNING refers to possible injury to the user or significant material damage to the Masterswitch if the user does not (carefully) follow the procedures. CAUTION! Special data, restrictions and rules with regard to preventing damage. EN / Masterswitch 25kW 230V-125A / September 2007 3

IMPORTANT SAFETY INSTRUCTIONS 2 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS WARNING This chapter describes important safety and operating instructions for use of a Masterswitch in residential, recreational vehicle (RV) and marine applications. 2.1 GENERAL 1 Before using the Masterswitch, read all instructions and cautionary markings on the Masterswitch and all appropriate sections of the manual. 2 To reduce the risk of electric shock Do not expose Masterswitch to rain, snow, spray, moisture, excessive pollution and condensing circumstances. 3 Use of an attachment or spare part not recommended or sold by Mastervolt may result in a risk of fire, electric shock, or injury to persons. 4 The Masterswitch is designed to be permanently connected to an AC electrical system. Installation of, and work on the Masterswitch, may be carried out only by a qualified, authorized and trained technician or electrician, consistent with the locally applicable standards and regulations 5 Make sure that all wiring is properly installed and in good electrical condition; and that wire size is large enough for ac ampere rating of the Masterswitch. Check the wiring on a regular base, at least once a year. Do not use the Masterswitch when the wiring is undersized or damaged. 6 Do not operate Masterswitch if it has received a sharp blow, been dropped, or otherwise damaged in any way; take it to a qualified serviceman. 7 Except during installation (see chapter 4), the Masterswitch may not be opened or disassembled. There are no serviceable parts inside the cabinet. Take it to a qualified, authorized and trained serviceman when service or repair is required. Incorrect reassembly may result in a risk of electric shock or fire. Only qualified, electrician installers are authorized to open the Masterswitch. 8 To reduce risk of electric shock, disconnect the Masterswitch from AC electrical system before attempting any maintenance or cleaning. 9 The Masterswitch must be provided with an equipment-grounding conductor to the AC-input ground terminal. Grounding and all other wiring must comply with local codes and ordinances. 10 Incorrect installation or reversing input and output wiring will lead to serious damage to the Masterswitch, wiring as well as accessories. Fuses can not prevent such damage and the warranty will be void. 11 In case of fire, you must use the fire extinguisher which is appropriate for electrical equipment. 12 If applied in a marine application in the United States, external connections to the Masterswitch shall comply with the United States Coast Guard Electrical Regulations (33CFR183, Sub part I) 2.2 WARNING REGARDING LIFE SUPPORT APPLICATIONS The Masterswitch is not sold for applications in any medical equipment intended for use as a component of any life support system unless a specific written agreement pertaining to such intended use is executed between the manufacturer and Mastervolt. Such agreement will require the equipment manufacturer either to contract additional reliability testing of the Masterswitch and/or to commit to undertake such testing as a part of the manufacturing process. In addition the manufacturer must agree to indemnify and not hold Mastervolt responsible for any claims arising from the use of the Masterswitch in the life support equipment. 2.3 GUARANTEE SPECIFICATIONS Mastervolt guarantees that this unit has been built according to the legally applicable standards and specifications. Should work take place, which is not in accordance with the guidelines, instructions and specifications contained in this users manual, then damage may occur and/or the unit may not fulfil its specifications. All of these matters may mean that the guarantee becomes invalid. The guarantee is limited to the costs of repair and/or replacement of the product. Costs for installation labor or shipping of the defective parts are not covered by this guarantee. 4 September 2007 / Masterswitch 25kW 230V-125A / EN

HOW IT WORKS 3 HOW IT WORKS 3.1 SOURCE PRIORITY The Masterswitch is the heart of the AC installation. It is designed to take over manual switching between two different AC power sources, indicated as INPUT 1 and INPUT 2. The Masterswitch automatically transfers the available AC power source to the OUTPUT. Therefore the Masterswitch is equipped with a source priority. If more than one AC power source is available, the source with the highest priority is switched to the OUTPUT. 3.2 INPUT 1 (GENERATOR) See figure 1. INPUT 1 has the highest priority, which means that AC power is transferred from INPUT 1 to the OUTPUT when AC power is available on INPUT 1. At the same time, INPUT 2 is denied, even when AC power is available. The generator or the shore power should be connected to INPUT 1. When power becomes available on INPUT 1, it is transferred to the OUTPUT after a delay of approximately 10 seconds. The 10 seconds delay time provides an easy start up for the generator. In normal situations the generator is stabilized after app. 3 sec. To make sure no voltage and frequency variations will occur the delay time is set to 10 sec. This increases the generator s lifetime If INPUT 1 is used to connect the shore, the delay time can be adjusted to 0 seconds. See chapter 4.7. 3.3 INPUT 2 (SHORE OR INVERTER) INPUT 2 has the lowest priority. If there is no AC power available on INPUT 1, AC power from INPUT 2 will be transferred to the OUTPUT. In this case, the Masterswitch is in a neutral state and consumes no energy it self. CAUTION! During transfer between one of the powersources, users are not supplied with power for a short time. Because of this, computers etc. connected to this group might loose data. INPUT 1 L1 N GND L1 N OUTPUT GND INPUT 2 L1 N GND Figure 1: Electrical diagram EN / Masterswitch 25kW 230V-125A / September 2007 5

INSTALLATION 4 INSTALLATION 4.1 GENERAL WARNING Be sure that all AC power sources are switched off or disconnected during installation. During installation and commissioning of the Masterswitch the Important Safety Instructions are applicable at all times. See chapter 2 of this manual. After unpacking, check the Masterswitch for possible damage. Do not use the Masterswitch if the cabinet is damaged. Check from the type number plate whether the AC voltage of the power sources is equal to the input voltage of the Masterswitch. Do not change the internal wiring of the Masterswitch. 4.2 AC WIRING For a safe installation the correct wire cross section must be applied. The indicated values stated in the table below are considered as guiding values. In critical situation the locally applicable rules and recommendations should be followed. AC-Current Minimum cross section: in mm² AWG 0-32 Amp 4 mm² AWG 10 32-48 Amp 6 mm² AWG 8 48-80 Amp 10 mm² AWG 6 80-125 Amp 16 mm² AWG 4 WARNING Don t use a cross section that is smaller than indicated! Under-sized cables and/or loose connections can cause dangerous overheating of the cables and/or terminals. Therefore use the proper size and tighten all connections well, in order to limit transition resistance as far as possible. See chapter 5 for recommended torques. Recommended wire colours (refer to locally applicable rules and recommendations): Single phase 230V AC installations: Wire color Meaning Indication: Brown or Black Phase L1 Blue Neutral N Green/Yellow Earth PE 4.3 EXTERNAL FUSES WARNING External fuses and earth leakage switches (RCD s) must be integrated in the wiring of all inputs and the output of the Masterswitch. The wiring to the AC-inputs and output must be protected by fuses which are suitable for the applied wire cross section (see 4.2). Rating of these fuses should never be higher than the maximum allowed input and output current of the Masterswitch; see table below. Model Masterswitch Masterswitch 25kW, 230V-125A Maximum allowed input and output current 125 Amps 4.4 GROUND CONNECTIONS For safety reasons it is very important that all ground connections of the power sources and power consumers are connected to the central ground connection of the ship or vehicle. Improper ground connections might lead to life treating situations. A reliable ground connection is made by connecting the ground connections of the sources and the consumers to the ground terminal of the Masterswitch. This ground terminal must be connected to the central ground connection of the ship / vehicle, which is connected to the hull of the ship / chassis of the vehicle. When a ship lies in sea water (salt) while using shore power, corrosion can occur. This corrosion is caused by potential differences between shore ground and ships ground. Using an isolation transformer will solve this problem. Mastervolt can provide a suitable transformer. 6 September 2007 / Masterswitch 25kW 230V-125A / EN

INSTALLATION INPUT 1 INPUT 2 R1 1 3 R3 Setting time delay INPUT 1 R2 2 4 R4 PE L N PE L N PE L N OUTPUT Figure 2: Connection EN / Masterswitch 25kW 230V-125A / September 2007 7

INSTALLATION 4.5 INPUTS See figure 2 to connect the AC power sources. Wire INPUT 1 INPUT 2 L (phase) 1 R1 N (neutral) 3 R3 PE (ground) Connections to the AC sources 4.6 OUTPUTS Connect the load to the terminals as indicated in figure 2. Wire OUTPUT L (phase) 2 + R2 N (neutral) R4 + 4 PE (ground) Connections to the AC output 4.7 SETTINGS Under normal circumstances adjustment of the Masterswitch is not recommended: after installation the Masterswitch is immediately ready for use. However specific circumstances may require adjustment of the switch-on time delay of INPUT 1. For instance when a generator needs to supply high starting currents during a longer period. This may occur when a small generator is used to power air-conditioning. CAUTION! Wrong adjustment of the switch-on time delay may lead to damage to the generator and/or the connected load. For this reason adjustments may only be carried out by trained technical engineers! 4.8 COMMISSIONING AFTER INSTALLATION Follow the steps described below to switch on the Masterswitch. 1 Tighten all cable glands to ensure the pull relief 2 Check all wiring and connections. 3 Close the cabinet. 4 Switch on the AC power sources. 4.9 DECOMMISSIONING If it is necessary to put the Masterswitch out of operation, follow the instructions in order of succession as described below: 1 Switch off all loads 2 Switch off the AC power sources. These power sources should be secured against unexpected and unintended switching on. 3 Open the casing of the Masterswitch 4 Check with a suitable voltage meter whether the inputs of the Masterswitch are voltage free. 5 Disconnect all the wiring Now the Masterswitch can be demounted in a safe way. 4.10 TRANSPORTATION Always use the original packing for transportation. Contact your local Mastervolt Service Centre for further details if you want to return the apparatus for repair. 4.11 RE-INSTALLATION To reinstall the Masterswitch, follow the instructions as described in chapter 4 See figure 2. Use a small flat blade screw driver to adjust the switch-on time delay. 8 September 2007 / Masterswitch 25kW 230V-125A / EN

ADDITIONAL INFORMATION 5 ADDITIONAL INFORMATION 5.1 SPECIFICATIONS GENERAL Masterswitch 25kW, 230V-125A Part number: 55003500 Product description: Manufacturer: ELECTRICAL Earth leakage breaker (RCD): Circuit breakers: Nominal voltage: Nominal current INPUT 1: Nominal current INPUT 2: Nominal current OUTPUT: Switching current (I eff, IEC947): AC Power consumption: Automatic two source selector switch with one output. Required in and output breakers and/or RCD s are not included. Mastervolt, Amsterdam, the Netherlands Not included Not included 230V, 50/60Hz 125 Amps 125 Amps 125 Amps 1100 Amps AC available on INPUT 1: 26 VA ± 10% Only AC available on INPUT 2: Transfer time by making Transfer time by braking 0 VA 20 35 msec 8 12 msec Delay time INPUT 1: Approximately 10 sec. (adjustable, see chapter 4.7) Recommended torque screw connections: 9 Nm (80 In-Lbs) Cross section single wire: 4 50 mm² (AWG 10-1/0) ENVIRONMENTAL Specified operation temperature Allowed operating temperature: None operating temperature: Relative humidity: -5 +60 C (23 140 F) (will meet specified tolerances) -40 +70 C (-40 158 F) (may not meet all specified tolerances) -60 +80 C (-76 176 F) (storage temperature) 95% max., non-condensing Protection degree: IP66 NEMA 4,4X Dimensions without cable glands: (H x W x D)= 291x241x168mm (11.5 x 9.5 x 6.6 inch) (see also section 5.2) Weight: Colour: Cable glands: 3.8kg (8.4Lbs) Gray RAL7035 All specifications are subject to change without prior notice 3 x PG29, maximum diameter: 17-27mm (0.67-1.06 inch) EN / Masterswitch 25kW 230V-125A / September 2007 9

ADDITIONAL INFORMATION 5.2 OUTLINE DRAWINGS All dimensions are in millimetres Figure 3: dimensions of the Masterswitch 10 September 2007 / Masterswitch 25kW 230V-125A / EN

ADDITIONAL INFORMATION 5.3 EC DECLARATION OF CONFIRMITY Manufacturer Address Mastervolt Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Herewith declares that: Product: 55003500 Masterswitch 25kW, 230V-125A Is in conformity with the provision of the EC, EMC directive 89/336/EEC and amendments 92/31/EEC, 93/68/EEC The following harmonized standards have been applied: Generic emission standard EN 50081-1:1992, Generic immunity standard EN 50082-1:1997, And the safety directive 73/23/EEC and amendment 93/68/EEC, with the following standard: Low voltage standard EN 60950:2000, Amsterdam, P.F. Kenninck, General Manager MASTERVOLT EN / Masterswitch 25kW 230V-125A / September 2007 11

Snijdersbergweg 93, 1105 AN Amsterdam, The Netherlands Tel : + 31-20-3422100 Fax : + 31-20-6971006 Email : info@mastervolt.com