Technical Datasheet clima RCM-FC 1. Product description

Similar documents
Technical Datasheet clima RCM-CC

Technical Datasheet clima BSK4-F / BSK4-F230 NK mêççìåí=çéëåêáéíáçå

252F 5WG FB_1 DELTA

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Room unit with PPS2 interface

User manual clima DL-110

TAC Xenta 121-FC Programmable Fan Coil Application

Room unit with PPS2 interface

584 5WG AB_1 DELTA

Room unit with PPS2 interface

User Manual LON MSeries. Moers, 22/01/2013. Version

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

Product and Function Description

DDC110-L1.. DDC110-L4 technolon Room Module

Product and Application Description

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

UCU Room Display. Operation Modes. Features. Applications DATASHEET

XPSMCMDI Input expansion module with screw term

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

Glass sensors 35. Supplementary products 39

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

KNX T-UP. Temperature Sensor. Technical specifications and installation instructions

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

VersaMax IP I/O Module

Product and functional description

Product and functional description

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

RCW11x-L Room Controller Technolon. Application. Product Description. RCW11x-L Room Controller Technolon

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Push button UP 287, 4 - fold

Power Supply HARTING pcon

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

QUINT-PS/ 1AC/24DC/ 5

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

PHOENIX CONTACT - 05/2007

IB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

XPSMCMDO Digital output pairs expansion modules with screw term

Power Supply HARTING pcon

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

TAC Xenta 121-HP Programmable Heat Pump Application

Installation Instructions

VersaMax IP Input Module

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Control Head for the integrated mounting on process valves

PHOENIX CONTACT - 10/2009

IB IL 24/48 DOR 2/W-XC-PAC

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

KNX/EIB Push button sensor 3 Plus F Safety instructions. 2 Device components. 3 Function

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

TRIO-DIODE/12-24DC/2X10/1X20

Operating and mounting instructions

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

XPSMCMMX inputs 2 output pairs expansion module with screw term

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

PHOENIX CONTACT Features

FL MC 2000E (SM40) LC

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

OTi DALI 75/ /700 D LT2 UF L

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Interface Relay CRINT-1x

Channel Switch CS. General Operating, Maintenance and Installation Manual

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

BMF400 Input/output module

DI572 Digital Input Module

IBS IL 24 BK RB-T-2MBD

RoHS. High shaft load capacity. Shock / vibration resistant

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

PHOENIX CONTACT - 07/2006

IB IL 24 DI 16 IB IL 24 DI 16-PAC

RCN122-L technolon Room Controller. Application. RCN122-L technolon Room Controller. Product Description

Blu2Light Light Management Installation in Luminaires

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

RCN132-L, RCN132-L-S1 technolon Room Controller

Product and Application Description

BA/BS4S Temperature Sensor Installation & Operating Instructions

DI561 Digital Input Module

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

IRMA MATRIX Release 2

BTL6-A_10-M -A1-S115. Data Sheet. english

Non-communicating room controllers

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

PLC Racks IC697CHS782/783

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Transcription:

Technical Datasheet 1. Product description The is a room control panel with an integrated temperature sensor for measuring the room temperature. The device is featured with a turn wheel to adjust the set point and up to two push buttons including LEDs for presence status and fan speed control. On the back of this unit there are 6 digital inputs for floating contacts available. There are also connections for communicating with up to two external Fan Coil Boxes. For more information consult our data sheets 410 302 clima FCB-24, 410 322 clima FCB-230, 410 342 clima FCB-10V Unit comes with jumper ring for mounting on cavity wall sockets or flush mounting sockets according to DIN VDE 0606. The front panel is designed for a standard 55 mm spacing and suits perfectly to the corresponding switch ranges from manufactures like Berker, Gira, Jung and Merten. For this reason the clima RCM offers the architect the complete freedom of choice in finding the suitable switch range design. An easy LNS-Plug-In for a comfortable configuration is available. with fan-speed- pushbutton with presence- and fanspeed- push-button with presence- and fanspeed- push-button (All Pictures show together with 55 mm frame. The frame is not included in the purchased parts package) Page 1 of 8

2. Mounting and connecting 2.1. Mounting Electrical devices must be assembled and installed by trained personnel only. Install the LON room temperature controller in a flush-mount switch socket with a recommended minimum depth of 47mm. Mounting must be done at representative locations for room temperature measurements in order to have an undisturbed measurement. Direct sunlight and air drafts are to be avoided. All 55mm spacing switch frames are suitable for this product. On units with set point dial, the screw to fasten the cover is beneath the dialing wheel. The dialing wheel can be pulled carefully from its axis. The LON service switch on units of the RCM-xx series can only be operated when the cover is removed. Before mounting the unit inside an flush-mount switch socket all cables have to connected. Afterwards the LON room temperature controller can be inserted into the socket and fixated with screws. The switch cover is put onto the metal ring and fixated by the room temperature cover. As a last step for units with the set point dial, the dial wheel is gently pushed onto the axis. 2.2. Dimensions 78 mm 40 mm 78 mm 49 mm Page 2 of 8

2.3. Connections 2.3.1 Layout of the connectors Digitaleingänge E 5,E6 & FC-BOX Kommunikation Spannungsversorgung & LON-BUS Digitaleingänge E 1 E4 figure 1 +2 4V GN AC D /DC /M AS SE LO N LO B N A 2.3.2 power supply and LON connections figure 2 Connection function type +~ power supply typ. +24V DC / AC power supply GND ground power supply A LON A LON bus connection B LON B LON bus connection Page 3 of 8

2.3.3 digital inputs E1 - E4 E1 E2 E3 E4 max. 6mm figure 3 connection function type E1 digital input 1 input E2 digital input 2 input E3 digital input 3 input E4 digital input 4 input 2.3.4 LON Service switch The LON service switch is only accessible when the cover is not mounted. Gently pull the dial wheel off. Beneath is a screw that holds the cover. After loosening of the screw the cover can be removed. Be careful not to damage the printed circuit boards found inside of the unit! The LON service switch is on the middle printed circuit board. You can operate it using a small screw driver. To the lower right the service LED can be seen. See the picture below: Page 4 of 8

LON ServiceTaster figure 4 figure 5: operate service switch with screw driver Page 5 of 8

2.4. Connection example figure 6: connection example for one Fan Coil Box Page 6 of 8

3. Technical data Power Supply Operating voltage Power consumption 24V DC +/-15% or 24V AC +/- 15% max. 1,44 W Network Network type Transceivertype TP/FT-10 (78kbps) FTT Connections Network Digital inputs (for connection to push-buttons or potential free-contacts) Fan Coil Box Control elements Service push-button Set point adjuster turn wheel Upper right push-button Lower left push-button Display elements LEDs 4-pin plug-in terminal connection for solid wires Ø 0,6-1,0mm four bus lines can be connected for each pin 6 x digital inputs, connection for solid or flexible wires Ø max. 0,8mm 2 x Fan Coil Box, connection for solid or flexible wires Ø max. 0,8mm Sends Neuron-ID when pressed Adjusts the temperature set point Range between+/- 1-5 K; range per software adjustable only order-no. 231x05: Presence control push-button,toggles presence status Fan speed control push-button, Controls fan speed mode: Automatic or manual mode [Levels: Low (1), Mid (2),High (3)] order-no. 231x04 and order-no. 231x05: Yellow: 4 LEDs for fan speed [A(utomatic), 1, 2, 3] order-no. 231x05: Red: Heating mode Blue: Cooling mode Yellow: Window contact Green: Presence Measurement range Measurement range +5 C to +50 C Measuring tolerance Measuring tolerance +/- 0,5 K (in the range of +5 C > T > +30 C) Housing Type of protection Dimensions Type / location of installation IP 20 (DIN 40050 / IEC 144) 70 x 70 x 41 [mm] (H x B x T) Mounting on cavity wall sockets or flush mounting sockets according to DIN VDE 0606 Ambient conditions Operating temperature Storage temperature Transportation temperature Rel. humidity Installation height -5 C... +45 C -25 C... +55 C -25 C... +70 C 5 %...93 % (without condensation) Up to 2000 m above sea level Safety Electrical isolation Class of protection SELV (EN 60 950) I (IEC 536 / VDE 106 Teil 1) Standards / guidelines Device safety Immunity Certification Acc. EN 50 090-2-2 Acc. EN 50 090-2-2 CE Page 7 of 8

4. Products 4.1. Order information Order number 231 334 W 231 334 B 231 334 A 231 335 W 231 335 B 231 335 A Description, with fan-speed-button, six digital inputs and FCB connector, pure white, with fan-speed-button, six digital inputs and FCB connector anthracite, with fan-speed-button, six digital inputs and FCB connector aluminium, with presence- and fanspeed-button, six digital inputs and FCB connector pure white, with presence- and fanspeed-button, six digital inputs and FCB connector anthracite, with presence- and fanspeed-button, six digital inputs and FCB connector aluminium 5. Support The information given in this manual has been carefully collated. Should you have any further questions relating to this product, please contact: spega - Spelsberg Gebäudeautomation GmbH Zechenstr. 70 D-47443 Moers Fon: +49 (2841) 88049-0 Fax: +49 (2841) 88049-49 Email: support@spega.de Page 8 of 8